• Title/Summary/Keyword: white light imaging

Search Result 48, Processing Time 0.025 seconds

New Diagnostic Techniques in Cancer of the Pharynx and Esophagus (인두암과 식도암의 새로운 진단내시경)

  • Cho, Joo Young;Cho, Won Young
    • Korean Journal of Bronchoesophagology
    • /
    • v.17 no.1
    • /
    • pp.14-18
    • /
    • 2011
  • The diagnosis and treatment of early gastrointestinal cancers is the gastroenterologists' mission because of national cancer screening program in South Korea. The detection of early cancers is emphasized, because these were previously treated with surgical treatment can be currently cured with endoscopic treatment. Gastroenterologists who achieved at least on some level can make an exact diagnosis regardless of what type of endoscopy, but generally, there are some required conditions for an optimal diagnosis. First, clinically important lesions have to be detected easily. Second, the border and morphology of lesions have to be characterized easily. Third, lesions have to be diagnosed exactly. Precancers and early cancers are often subtle and can pose a challenge to gastroenterologists to visualize using standard white light endoscopy. The use of dye solutions aids the diagnosis of early gastrointestinal cancers, however, it is a quite cumbersome to use dye solutions all the time and the solution often bothers the exact observation by pooling into the depression or ulceration of the lesion. To overcome this weakness, newer endoscopes are now developed so called "image enhanced endoscopy" using optical and/or electronic methods such as narrow band imaging (NBI), autofluorescence imaging (AFI), i-scan, flexible spectral imaging color enhancement (FICE) and confocal endomicroscopy (CLE).

  • PDF

Identification and Correction of Microlens-array Error in an Integral-imaging-microscopy System

  • Imtiaz, Shariar Md;Kwon, Ki-Chul;Alam, Md. Shahinur;Hossain, Md. Biddut;Changsup, Nam;Kim, Nam
    • Current Optics and Photonics
    • /
    • v.5 no.5
    • /
    • pp.524-531
    • /
    • 2021
  • In an integral-imaging microscopy (IIM) system, a microlens array (MLA) is the primary optical element; however, surface errors impede the resolution of a raw image's details. Calibration is a major concern with regard to incorrect projection of the light rays. A ray-tracing-based calibration method for an IIM camera is proposed, to address four errors: MLA decentering, rotational, translational, and subimage-scaling errors. All of these parameters are evaluated using the reference image obtained from the ray-traced white image. The areas and center points of the microlens are estimated using an "8-connected" and a "center-of-gravity" method respectively. The proposed approach significantly improves the rectified-image quality and nonlinear image brightness for an IIM system. Numerical and optical experiments on multiple real objects demonstrate the robustness and effectiveness of our proposed method, which achieves on average a 35% improvement in brightness for an IIM raw image.

The Clinical Accuracy of Endoscopic Ultrasonography and White Light Imaging in Gastric Endoscopic Submucosal Dissection

  • Park, Soon-Hong;Sung, Sang-Hun;Lee, Seung-Jun;Jung, Min-Kyu;Kim, Sung-Kook;Jeon, Seong-Woo
    • Journal of Gastric Cancer
    • /
    • v.12 no.2
    • /
    • pp.99-107
    • /
    • 2012
  • Purpose: Gastric mucosal neoplastic lesions should have characteristic endoscopic features for successful endoscopic submucosal dissection. Materials and Methods: Out of the 1,010 endoscopic submucosal dissection, we enrolled 62 patients that had the procedure cancelled. Retrospectively, whether the reasons for cancelling the endoscopic submucosal dissection were consistent with the indications for an endoscopic submucosal dissection were assessed by analyzing the clinical outcomes of the patients that had the surgery. Results: The cases were divided into two groups; the under-diagnosed group (30 cases; unable to perform an endoscopic submucosal dissection) and the over-diagnosed group (32 cases; unnecessary to perform an endoscopic submucosal dissection), according to the second endoscopic findings, compared with the index conventional white light image. There were six cases in the under-diagnosed group with advanced gastric cancer on the second conventional white light image endoscopy, 17 cases with submucosal invasion on endoscopic ultrasonography findings, 5 cases with a size greater than 3 cm and ulcer, 1 case with diffuse infiltrative endoscopic features, and 1 case with lymph node involvement on computed tomography. A total of 25 patients underwent a gastrectomy to remove a gastric adenocarcinoma. The overall accuracy of the decision to cancel the endoscopic submucosal dissection was 40% (10/25) in the subgroup that had the surgery. Conclusions: The accuracy of the decision to cancel the endoscopic submucosal dissection, after conventional white light image and endoscopic ultrasonography, was low in this study. Other diagnostic options are needed to arrive at an accurate decision on whether to perform a gastric endoscopic submucosal dissection.

Effects of Shield Materials on the Growth and Yield Characteristics of Melon Grown inside a Plastic Greenhouse in Summer Season (고온기 멜론 시설재배 시 자재별 차광 효과)

  • Lee, Jae Han;Lee, Jung Sup;Kwon, Joon Kook;Yeo, Kyung Hwan;Bang, Ji Woong;Kim, Jin Hyun;Lee, Choung Keun;Park, Kyoung Sub;Myung, Dong Ju
    • Journal of Bio-Environment Control
    • /
    • v.30 no.4
    • /
    • pp.304-311
    • /
    • 2021
  • This Experiment was conducted to determine the effects of light shield materials when melon grown inside a plastic greenhouse in summer season. The average temperatures were 36.6℃, 34.5℃ and 34.0℃ respectively for the control(non-shield), coating agent, and the white net. The light transmittances were 69% and 75%, respectively inside the greenhouse treated with the coating agent and white net immediately after applicants, compared with that inside the control greenhouse. At the 40 and 80 days after treatment, the light transmittances for the coating agent were 92% and 98%, respectively, indicating it was slowly decomposed and removed, but there was no change in the transmittance for the white net. While the leaf number did not differ among the treatments, the plant height was higher in the white net and shading agent than in control. The weight of the leaves, fresh-weight and dry-weight were no different from that of shading, but it became heavier in the later stages. The marketable fruit yield was increased by 6% for white nets and 5% for the coating agent compared to control, there was no statistical significance. Therefore, coating agent is considered as an effective method to lower temperature during high temperature period, but it is preferable to use it in consideration of cultivation period, because the coating agent is gradually removed.

The Role of the Narrow Band Imaging for Lung Cancer (폐암에서의 협대역 내시경의 역할)

  • Park, Jinkyeong;Choi, Chang Min
    • Korean Journal of Bronchoesophagology
    • /
    • v.17 no.1
    • /
    • pp.5-8
    • /
    • 2011
  • The proliferation of new technologies has significantly enhanced the diagnostic capabilities of flexible bronchoscopy compared with traditional methods. Narrow band imaging (NBI), an optical technique in which filtered light enhances superficial neoplasms based on their neoangiogenic patterns, was developed to screen for central intraepithelial moderate or severe dysplasia, carcinoma in situ (CIS), and microinvasive neoplasia in patients at risk for lung cancer. Because angiogenesis occurs preferentially in dysplastic and neoplastic lesions, NBI may identify early dysplastic lesions better than white light bronchoscopy (WLB) currently in use. NBI bronchoscopy can be used not only to detect precancerous lesions, but also to screen for cancerous lesions. We prospectively evaluated 101 patients with suspected lung cancer between July 2009 and June 2010. All were previously scheduled for flexible bronchoscopy CT scans. Abnormal NBI was defined by Shibuya's descriptors (tortuous, dotted, or spiral and screw patterns). Biopsies of 132 lesions in 92 patients showed that 78 lesions (59.1%) were malignant and 54 (40.9%) were benign. The diagnostic sensitivity of bronchoscopy in detecting malignancy was 96.2% (75/78). When assorted by lesion pattern, the sensitivity and specificity of NBI bronchoscopy in detecting malignancies were 69.2% (54/78) and 96.3% (52/54), respectively, for the spiral and screw pattern and 14.1% (11/78) and 96.3% (52/54), respectively, for the dotted pattern. Unexpectedly, additional cancerous lesions were detected in five patients (2 dotted and 3 spiral and screw). As a screening tool for malignant lesions, NBI bronchoscopy should assess combinations of all three lesion. The dotted and spiral and screw patterns may be helpful in determining which lesions should be biopsied. NBI bronchoscopy may be useful not only for the diagnosis of early-stage lung cancer but also for more accurate local staging of lung cancer.

  • PDF

Commercially Available High-Speed Cameras Connected with a Laryngoscope for Capturing the Laryngeal Images (상용화 된 고속카메라와 후두내시경을 이용한 성대촬영 방법의 소개)

  • Nam, Do-Hyun;Choi, Hong-Shik
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.21 no.2
    • /
    • pp.133-138
    • /
    • 2010
  • Background and Objectives : High-speed imaging can be useful in studies of linguistic and artistic singing styles, and laryngeal examination of patients with voice disorders, particularly in irregular vocal fold vibrations. In this study, we introduce new laryngeal imaging systems which are commercially available high speed cameras connected with a laryngoscope. Materials and Method : The laryngeal images were captured from three different types of cameras. First, the adapter was made to connect with laryngoscope and Casio EX-F1 to capture the images using $2{\times}150$ Watt Halogen light source (EndoSTROB) at speeds of 1,200 tps (frame per second)($336{\times}96$). Second, Phantom Miro ex4 was used to capture the digital laryngeal images using Xenon Nova light source 175 Watt (STORZ) at speeds of 1,920 fps ($512{\times}384$). Finally, laryngeal images were captured using MotionXtra N-4 with 250 Watt halogen lamp (Olympus CLH-250) light source at speeds of 2,000tps ($384{\times}400$) by connecting with laryngoscope. All images were transformed into the Kymograph using KIPS (Kay's image processing Software) of Kay Pentex Inc. Results: Casio EX-F1 was too small to adjust the focus and screen size was diminished once the images were captured despite of high resolution images. High quality of color images could be obtained with Phantom Miro ex4 whereas good black and white images from Motion Xtra N-4 Despite of some limitations of illumination problems, limited recording time capacity, and time consuming procedures in Phantom Miro ex4 and Motion Xtra N-4, those portable devices provided high resolution images. Conclusion : All those high speed cameras could capture the laryngeal images by connecting with laryngoscope. High resolution images were able to be captured at the fixed position under the good lightness. Accordingly, these techniques could be applicable to observe the vocal fold vibration properties in the clinical practice.

  • PDF

Low Cost Omnidirectional 2D Distance Sensor for Indoor Floor Mapping Applications

  • Kim, Joon Ha;Lee, Jun Ho
    • Current Optics and Photonics
    • /
    • v.5 no.3
    • /
    • pp.298-305
    • /
    • 2021
  • Modern distance sensing methods employ various measurement principles, including triangulation, time-of-flight, confocal, interferometric and frequency comb. Among them, the triangulation method, with a laser light source and an image sensor, is widely used in low-cost applications. We developed an omnidirectional two-dimensional (2D) distance sensor based on the triangulation principle for indoor floor mapping applications. The sensor has a range of 150-1500 mm with a relative resolution better than 4% over the range and 1% at 1 meter distance. It rotationally scans a compact one-dimensional (1D) distance sensor, composed of a near infrared (NIR) laser diode, a folding mirror, an imaging lens, and an image detector. We designed the sensor layout and configuration to satisfy the required measurement range and resolution, selecting easily available components in a special effort to reduce cost. We built a prototype and tested it with seven representative indoor wall specimens (white wallpaper, gray wallpaper, black wallpaper, furniture wood, black leather, brown leather, and white plastic) in a typical indoor illuminated condition, 200 lux, on a floor under ceiling mounted fluorescent lamps. We confirmed the proposed sensor provided reliable distance reading of all the specimens over the required measurement range (150-1500 mm) with a measurement resolution of 4% overall and 1% at 1 meter, regardless of illumination conditions.

Effects of Scintillation Crystal Surface Treatments on Gamma Camera Imaging (섬광체 옆표면처리가 감마카메라 영상에 미치는 효과)

  • Kim, J.H.;Choi, Y.;Oh, C.H.;Kim, J.Y.;Lee, M.Y.;Kim, S.E.;Choe, Y.S.;Joo, K.S.;Kim, B.T.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.303-304
    • /
    • 1998
  • We investigated the effects of scintillation crystal surface treatment on gamma camera imaging. The NaI(Tl) and CsI(Tl) (20 mm (dia.) $\times10mm$ (thick) plate) scintillators were chosen for this study. Two different surface treatments, white and black reflectors, were applied to NaI(Tl) and CsI(Tl). The optical properties of generated scintillation light were evaluated using Monte Carlo simulation and postion sensitive photo multiplier tube (PSPMT). We measured sensitivity, energy resolution and spatial resolution of a gamma camera system with the scintillators coupled to a PSPMT. Based on the results, we concluded that the careful consideration of surface treatments of the scintillator was necessary in order to develop the gamma camera having good sensitivity and spatial resolution.

  • PDF

Advanced endoscopic imaging for detection of Barrett's esophagus

  • Netanel Zilberstein;Michelle Godbee;Neal A. Mehta;Irving Waxman
    • Clinical Endoscopy
    • /
    • v.57 no.1
    • /
    • pp.1-10
    • /
    • 2024
  • Barrett's esophagus (BE) is the precursor to esophageal adenocarcinoma (EAC), and is caused by chronic gastroesophageal reflux. BE can progress over time from metaplasia to dysplasia, and eventually to EAC. EAC is associated with a poor prognosis, often due to advanced disease at the time of diagnosis. However, if BE is diagnosed early, pharmacologic and endoscopic treatments can prevent progression to EAC. The current standard of care for BE surveillance utilizes the Seattle protocol. Unfortunately, a sizable proportion of early EAC and BE-related high-grade dysplasia (HGD) are missed due to poor adherence to the Seattle protocol and sampling errors. New modalities using artificial intelligence (AI) have been proposed to improve the detection of early EAC and BE-related HGD. This review will focus on AI technology and its application to various endoscopic modalities such as high-definition white light endoscopy, narrow-band imaging, and volumetric laser endomicroscopy.

Utility of narrow-band imaging with or without dual focus magnification in neoplastic prediction of small colorectal polyps: a Vietnamese experience

  • Tien Manh Huynh;Quang Dinh Le;Nhan Quang Le;Huy Minh Le;Duc Trong Quach
    • Clinical Endoscopy
    • /
    • v.56 no.4
    • /
    • pp.479-489
    • /
    • 2023
  • Background/Aims: Accurate neoplastic prediction can significantly decrease costs associated with pathology and unnecessary colorectal polypectomies. Narrow-band imaging (NBI) and dual-focus (DF) mode are promising emerging optical technologies for recognizing neoplastic features of colorectal polyps digitally. This study aimed to clarify the clinical usefulness of NBI with and without DF assistance in the neoplastic prediction of small colorectal polyps (<10 mm). Methods: This cross-sectional study included 530 small colorectal polyps from 343 consecutive patients who underwent colonoscopy at the University Medical Center from September 2020 to May 2021. Each polyp was endoscopically diagnosed in three successive steps using white-light endoscopy (WLE), NBI, and NBI-DF and retrieved for histopathological assessment. The diagnostic accuracy of each modality was evaluated with reference to histopathology. Results: There were 295 neoplastic polyps and 235 non-neoplastic polyps. The overall accuracies of WLE, WLE+NBI, and WLE+NBI+NBI-DF in the neoplastic prediction of colorectal polyps were 70.8%, 87.4%, and 90.8%, respectively (p<0.001). The accuracy of WLE+NBI+NBI-DF was significantly higher than that of WLE+NBI in the polyp size ≤5 mm subgroup (87.3% vs. 90.1%, p<0.001). Conclusions: NBI improved the real-time neoplastic prediction of small colorectal polyps. The DF mode was especially useful in polyps ≤5 mm in size.