• 제목/요약/키워드: wet-out

검색결과 739건 처리시간 0.032초

Population structure and habitat use of gelada baboon (Theropithecus gelada) in Wof-Washa Forest (Gosh-Meda Area), Central Ethiopia

  • Goshme, Birhanu;Yihune, Mesele
    • Journal of Ecology and Environment
    • /
    • 제42권4호
    • /
    • pp.292-297
    • /
    • 2018
  • Background: Gelada baboon is one of the endemic mammals of Ethiopia residing in different highlands. The population structure and habitat use of gelada baboon in Wof-Washa particularly Gosh Meda area was investigated from September 2016 to August 2017. Total counting method was used to collect data on the population status by dividing the study area in to four blocks, namely, Kundi, Arbgebeya, Goshber, and Goshmeda. Data were analyzed using SPSS software. The age-sex category and the numbers of geladas found within the different blocks were analyzed using one-way ANOVA, and paired t test was also used to analyze the pair wise comparison of the different age and sex categories during both dry and wet seasons. Results: A total of 435 and 471 gelada baboons were counted during the wet and dry seasons, respectively. The maximum group size consisted of 178 individuals whereas the minimum group size contained 53 individuals. Out of the total population adult females accounted for 54.7% in the wet and 54.56% in the dry seasons. There was a significant difference among the age-sex categories in both the wet ($F_{2432}=630$, P < 0.05) and dry ($F_{2468}=696.6$, P < 0.05) seasons. The male to female ratio was 1:5.7 during wet season and 1:5.8 during dry season. So that the population will have a better chance to increase in the study area. Conclusion: Wof-Washa Forest could be a good site for eco-tourism activities due to the presence of endemic animals and its scenic beauty. However, the quality of the habitat is decreasing due to livestock grazing, agricultural expansion, and invasion of exotic plants species. Therefore, appropriate conservation measures should be implemented to conserve gelada baboon in particular and other wildlife resources in general.

고문헌 보존처리의 클리닝 방법에 따른 인공열화지 물성 변화 - 침적 습식클리닝을 중심으로 - (The Change of Physical Properties of Artificial aging Paper in the Cleaning Process for the Conservation Treatment of Historical Paper Documents - Focusing on Immersion Wet Cleaning -)

  • 정선화;조안나
    • 헤리티지:역사와 과학
    • /
    • 제46권1호
    • /
    • pp.228-237
    • /
    • 2013
  • 지류문화재는 유기질이라는 재질의 특성상 시간이 지나면서 여러 가지 복합적인 손상인자(물리적 화학적 생물학적 인위적 원인)에 의해 유물의 보존성에 영향을 받고 있다. 그리하여 그 손상 정도에 따라 적절한 보존처리를 실시하게 되는데 그중 유물의 오염원을 제거하는 습식클리닝 처리가 지류문화재를 구성하는 주 원료인 한지의 재질에 미치는 영향을 분석해 보고자 본 연구를 실시하였다. 분석방법은 공시재료로 인공열화지를 사용하였고 습식클리닝(침적식)을 적용하여 처리 전 후의 색차와, 내절강도를 분석하였다. 분석결과 습식클리닝(침적식)에 의한 색도의 변화와 내절강도는 30분 침적을 2회 반복 처리하였을 때 가장 높은 수치를 나타냈다. 따라서 이때가 클리닝의 효율과 재질의 안정성이 가장 양호함을 알 수 있었다.

우리나라 토착근류균(土着根瘤菌)의 제(諸) 특성(特性) 연구(硏究) -I. 영남지역(嶺南地域) 토착(土着) 대두근류균(大豆根瘤菌)의 접종효과(接種效果)와 취락형태적(聚落形態的) 분포특성(分布特性) (Characteristics of Indigenous Rhizobium to Korean Soils -I. Symbiotic Potentials of Bradyrhizobium japonicum Populations and Their Colony Morphological Characteristics in Yeongnam Soils)

  • 강위금;;정연태
    • 한국토양비료학회지
    • /
    • 제23권1호
    • /
    • pp.60-66
    • /
    • 1990
  • 영남지역(嶺南地域)의 수종(數種) 토양통(土壤統)에서 경작여부(耕作與否)에 따른 토착(土着) 대두근류균(大豆根瘤菌)의 분포특성(分布特性)을 구명(究明)하였다. 이를 위하여, 토양통(土壤統)이 서로 다른 5개(個) 지점(地點)의 경작지(耕作地)와 미경작지(未耕作地) 토양(土壤)의 대두(大豆) 접종효과(接種效果)(Soil inoculum potential)와 토착근류균(土着根瘤菌)의 취락형태적(聚落形態的) 분포특성(分布特性)을 조사(調査)하였는데 그 결과(結果)는 다음과 같았다. 1. 영남지역(嶺南地域)에 분포(分布)한 토착(土着) 대두근류균(大豆根瘤菌)의 밀도(密度)는 경작지(耕作地)의 경우 $10^4Cells/g$. soil 이상(以上)이었으나 미경작지(未耕作地)에서는 경미(輕微)하였다. 2. 경작지(耕作地) 토양(土壤)의 대두(大豆) 접종효과(接種效果)(Soil inoculum potential)는 NifTAL의 우수근류근(優秀根瘤菌) 접종제(接種劑) TAL 보다 좋았고, 대두근류균(大豆根瘤菌)의 질소고정(窒素固定) 특성면(特性面)에서 근류(根瘤) 무게가 근류수(根瘤數)를 보상(報償)하였다. 3. 토착(土着) 대두근류균(大豆根瘤菌)의 취락형태별(聚落形態別) 분포(分布)는 경작여부(耕作與否)에 따라 상이(相異)하였는데, "Dry"형(形) 기경지(旣耕地)에서, "Wet"형(形)은 미경작지(未耕作地)에서 각각(各各) 우점경향(優占傾向)을 보였다. 4. 토착(土着) 대두근류균(大豆根瘤菌)의 취락형태별(聚落形態別) 공생효과(共生效果)는 "Dry"형(形)이 "Wet"형(形)보다 좋았다. 따라서 숙전(熟田)에서의 대두생육(大豆生育)은 "Dry"형(形) 토착(土着) 대두근류균(大豆根瘤菌)의 밀도(密度)에 크게 영향(影響)을 받을 것으로 판단(判斷)되었다.

  • PDF

상용급 석탄가스화플랜트 최적설계에 관한 연구 (A study on the engineering optimization for the commercial scale coal gasification plant)

  • 김병현;민종선;김재환
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 추계학술대회 초록집
    • /
    • pp.131.1-131.1
    • /
    • 2010
  • This study was conducted for engineering optimization for the gasification process which is the key factor for success of Taean IGCC gasification plant which has been driven forward under the government support in order to expand to supply new and renewable energy and diminish the burden of the responsibility for the reduction of the green house gas emission. The gasification process consists of coal milling and drying, pressurization and feeding, gasification, quenching and HP syngas cooling, slag removal system, dry flyash removal system, wet scrubbing system, and primary water treatment system. The configuration optimization is essential for the high efficiency and the cost saving. For this purpose, it was designed to have syngas cooler to recover the sensible heat as much as possible from the hot syngas produced from the gasifier which is the dry-feeding and entrained bed slagging type and also applied with the oxygen combustion and the first stage cylindrical upward gas flow. The pressure condition inside of the gasifier is around 40~45Mpg and the temperature condition is up to $1500{\sim}1700^{\circ}C$. It was designed for about 70% out of fly ash to be drained out throughout the quenching water in the bottom part of the gasifier as a type of molten slag flowing down on the membrane wall and finally become a byproduct over the slag removal system. The flyash removal system to capture solid particulates is applied with HPHT ceramic candle filter to stand up against the high pressure and temperature. When it comes to the residual tiny particles after the flyash removal system, wet scurbbing system is applied to finally clean up the solids. The washed-up syngas through the wet scrubber will keep around $130{\sim}135^{\circ}C$, 40~42Mpg and 250 ppmv of hydrochloric acid(HCl) and hydrofluoric acid(HF) at maximum and it is turned over to the gas treatment system for removing toxic gases out of the syngas to comply with the conditions requested from the gas turbine. The result of this study will be utilized to the detailed engineering, procurement and manufacturing of equipments, and construction for the Taean IGCC plant and furthermore it is the baseline technology applicable for the poly-generation such as coal gasification(SNG) and liquefaction(CTL) to reinforce national energy security and create new business models.

  • PDF

활성탄 사용에 따른 습식세정시설에서의 대기오염물질 제거효율 평가 (Removal Efficiencies Estimation of Air Pollutants at Wet Scrubber Using Activated Carbon)

  • 신찬기;권명희;전종주;신대윤
    • 환경위생공학
    • /
    • 제18권2호
    • /
    • pp.87-93
    • /
    • 2003
  • This study carried out to recommend adaptable technologies and countermeasures for performance improvement of Wet Scrubber(WS) in industrial waste incinerator. When not using the Activated Carbon(AC), the removal efficiency of dust and HCl is 73%, 92%. And particulate phase and gaseous phase dioxins removal efficiency was evaluated up to 31% and 12%. In this case, dioxins enrichment was not revealed in WS. When using the AC mixing with scrubbing water, the case of 1,000ppm, removal efficiency of particulate phase dioxins was about 51%, and gaseous phase dioxins was about 96%. The case of 2,000ppm, removal efficiency of particulate phase dioxins was about 55%, and gaseous phase dioxins was about 97%. And the case of 3,500ppm, the removal efficiency of particulate phase dioxins was about 35%, and gaseous phase dioxins was about 96% respectively. By this study, using the AC was more useful to remove the gaseous phase dioxins, and needed to use proper concentration of the AC, that in case of 3,500ppm, the particulate phase dioxins removal efficiency was more lower than other cases.

완충재 적용에 따른 습식온돌의 구조안전성 평가를 위한 실험연구 (An Experimental Study on Structural Safety Assesment of Wet Type Floor Heating System with Insulation)

  • 안재원;전명훈;이범식;이도헌
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 춘계학술대회논문집
    • /
    • pp.287-290
    • /
    • 2005
  • Housing is demanded to convert simple dwelling space into delightful one by improving of standard of living by economic development It is interested in the impact noise of the apartment housing that is revised to housing construction criteria at 29 March 2005 and then regulated the level of floor impact noise by the rule. The plan, which is actively investigated by counterplan for the reduction of impact noise, is application of sound insulation. In generally, first target by using insulation is the reduction of floor thermal transmittance in floor heating system of apartment housing. It is recently proposed soft materials that reduce the impact noise. However, it is a fact that the application of soft sound insulation includes some problem about structural performance. In this study, we made wet-heating specimen with various sound insulations, and carried out structralexperiment for evaluating the structural safety of it.

  • PDF

탄소와 목재섬유 혼합물을 이용한 전자기파 차폐용 시트의 제조 (The Manufacturing of Electromagnetic Shielding Sheet Using the Carbon and Wood Fiber Mixture)

  • 김형진;엄기증
    • 펄프종이기술
    • /
    • 제38권4호
    • /
    • pp.68-75
    • /
    • 2006
  • Electromagnetic shielding sheet using the carbon and wood fiber mixture was manufactured in an effort to develop an electromagnetic shielding packaging material. Carbon fibers were cut into 5, 10, and 15 mm using the automatic cutting device and blown and dispersed using compression air passed through the fine nozzle. Then carbon fibers were slurried with water (0.1% consistency), and softwood kraft pulp along with cone starch were added. The wet mats were manufactured by dewatering in modified hand-sheet machine. The wet mats were pressed upto $4kgf/cm^2$ in the carbon and wood fiber mixture mat press. The wet mats were dried in the automatic controlled plate dryer. Investigation on the formation and surface structure of the newly developed carbon and wood fiber mixture electromagnetic shielding sheet were carried out using the scanning electron microscopy and the image analyzer. Finally electromagnetic shielding characteristics of the newly developed carbon and wood mixture sheet were measured using net-work analyser. The result was promising in the light of the fact that this method could open a new way to substitute the expensive imported electromagnetic shielding sheet.

저변형률시험법에 의한 섬유강화 복합재료의 응력부식균열에 관한 연구 (A Study on Stress Corrosion Cracking of Fiber Reinforced Composite by Slow Strain Rate Test)

  • 임재규;최태수
    • 대한기계학회논문집A
    • /
    • 제20권11호
    • /
    • pp.3433-3440
    • /
    • 1996
  • This paper was investigation of the stres corrosion cracking(SCC) mechanism and the properties of corrosion fracture surface of glass fiber reinforced plastics(GFRP) produced by hand lay up(HLU) method in synthetic sea water. Test material is GFRP, that was used vinylester type epoxy acrylate resin and an unsaturated polyester as the matrix and the chopped strand mat(CSM) type E-glss fiber as the reinforcement. The slow strain rate test(SSRT) was performed on dry, wet and saturated wet specimens in sea water. Here the pH concentration of synthetic sea water was 8.2 and the strain rate is 1 x $10^{-6}$($sec^{-1}$) and test temperature ranges varied from $-60^{\circ}C$ to $80^{\circ}C$. It could be confirmed the fact that wet specimens tested at a particular test temperature ranges were appeared the eviences of SCC such as con-planar, mirror and hackle zone. Moreover, SCC of GFRP in sea water was characterised by falt fracture surfaces with only small amounts of fiber pull-out, in partial.

실차 실험을 통한 제동순시간에 의한 타이어-노면마찰계수에 관한 연구 (An Experimental Study of Tire-Road Friction Coefficient by Transient Brake Time)

  • 한창평;박경석;최명진;이종상;신운규
    • 한국정밀공학회지
    • /
    • 제24권7호
    • /
    • pp.106-111
    • /
    • 2007
  • In this paper, the transient brake time was studied on the van type vehicle with accelerometer. Experiments were carried out on the asphalt(new and polished), unpacked road(earth and gravel) and on wet or dry road conditions. The transient brake time is not effected bzy the vehicle speed. The transient brake time is about 0.41$\sim$0.43second on the asphalt road surface and the error range is within 0.1$\sim$0.16second. For the asphalt road condition, the transient brake time is not effected by both new asphalt road surface and the polished asphalt road surface. With compared by dry and wet road surface condition, the transient brake time of wet condition is longer than dry road condition and compared with unpacked road condition and packed road condition, unpacked road condition is shorter than packed road condition. It is considered that the transient brake time is effected by the road surface fraction coefficient. In other words, the transients brake time increases as friction coefficient decreases.

형광물질을 이용한 대기 중 오존 Passive Sampler의 개발 (Development of a Passive Sampler using a Fluorescence Material for the Ambient Ozone)

  • 임봉빈;정의석;김선태
    • 한국대기환경학회지
    • /
    • 제20권4호
    • /
    • pp.483-491
    • /
    • 2004
  • The purpose of this study is to develop an ozone passive sampler and to evaluate its performance p-Acetamidophenol using as the reagent for ozone reacts specifically with the ambient ozone to produce a fluorescence material (p-acetamidopheonl dimer). The volume of absorbent solution and the extraction time determined at suitable conditions for measuring ozone were 100$\mu$L and 60 min, respectively. The changes of fluorescence were observed with incresing the storage period of passive samplers in ambient air. but the cool storage in a refrigerator did not remarkably influence the increase of fluorescence. The measurement for the precision oi the passive sampling was carried out with duplicate measurement of passive samplers. The intra-class correlation coefficients of passive samplers using dry and wet filters were 0.992 and 0.962, respectively The results from field validation tests indicated practical agreement (dry filter: r=0.963, wet filter: r=0.995) between the passive sampler and an UV photometric $O_3$ analyzer. The limit of quantification of ozone passive samplers with sampling time of 8 hr (wet filter) and 24 hr (dry filter) were 8.0 ppb and 2.7 ppb, respectively.