• Title/Summary/Keyword: wet-out

Search Result 739, Processing Time 0.036 seconds

Alginic acid-silica hydrogel coatings for the protection of ssmotic distillation membranes against wet-out by surface-active agents

  • Xu, J.B.;Spittler, D.A.;Bartley, J.P.;Johnson, R.A.
    • Proceedings of the Polymer Society of Korea Conference
    • /
    • 2006.10a
    • /
    • pp.354-354
    • /
    • 2006
  • Alginic acid-silica hydrogel films was prepared for testing as protective coating materials for PTFE OD membranes. Unprotected hydrophobic membranes are subject to wet-out when contacted by surface-active agents. Films were characterised using SEM, XRD, DSC, mechanical strength measurements, and water-swelling measurements. In OD trials using coated membranes, no wet-out occurred over the 15 h duration of three consecutive 5 h OD trials using orange oil-water mixtures. In the case of detergent solutions, the coating afforded protection to the membrane for 4-5 h. In a separate trial, no wet-out occurred when the coated side of the membrane was placed in contact with 1.2 wt % orange oil for 72 hours.

  • PDF

The Properties of High Speed AlGaAs/GaAs Infrared LED by using Metal wet etch process (습식식각공정에 의한 High Speed용 AlGaAs/GaAs 적외선 LED 소자의 특성)

  • Lee, Cheol-Jin;Ra, Yong-Choon;Sung, Man-Young;Lee, Eun-Chul
    • Proceedings of the KIEE Conference
    • /
    • 1995.11a
    • /
    • pp.352-354
    • /
    • 1995
  • The optical and electrical properties of High Speed AlGaAs infrared LED by using metal wet etch process instead of metal lift-off process are investigated. The power out increases when metal contact is patterned by wet etch process. Forward voltage and Reverse voltage for metal wet etch process represent higher value than the metal lift-off process. The aging effect of power out also indicates good results with wet etch process. The wet etch process for metal contact reveals reliable LED device properties.

  • PDF

Pull-out Strengths of GFRP-Concrete Bond Exposed to Applied Environmental Conditions

  • Kabir, Muhammad Ikramul;Samali, Bijan;Shrestha, Rijun
    • International Journal of Concrete Structures and Materials
    • /
    • v.11 no.1
    • /
    • pp.69-84
    • /
    • 2017
  • This paper presents results of an experimental investigation on the behaviour of bond between external glass fibre reinforced polymer reinforcement and concrete exposed to three different environmental conditions, namely, temperature cycles, wet-dry cycles and outdoor environment separately for extended durations. Single shear tests (pull-out test) were conducted to investigate bond strengths (pull-out strengths) of control (unexposed) and exposed specimens. Effect of the exposure conditions on the compressive strength of concrete were also investigated separately to understand the effect of changing concrete compressive strength on the pull-out strength. Based on the comparison of experimental results of exposed specimens to control specimens in terms of bond strengths, failure modes and strain profiles, the most significant degradation of pull-out strength was observed in specimens exposed to outdoor environment, whereas temperature cycles did not cause any deterioration of strength.

Development of Direct-Wet-Rice-Seedling Machines in Korea

  • Rhee, Joong-Young;Lee, Chong-Ho-
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1993.10a
    • /
    • pp.256-266
    • /
    • 1993
  • History , achievement and future of direct-wet-rice-seeding technique in Korea and problems encountered in on-farming research were introduced. Some farmers are very eager to lower production cost and save labor. Their effort results in several direct-wet-seeding methods and seeding machines. The design problems and improvement points related to the direct -wet-rice-seeding machines were drawn out of field test.

  • PDF

Study on Cooling Characteristic Improvement in Underwater Wet Arc Welding of TMCP Steelplate (TMCP강의 습식수중 아크용접부의 냉각특성 개선에 관한 연구)

  • 김민남
    • Journal of Ocean Engineering and Technology
    • /
    • v.6 no.2
    • /
    • pp.113-124
    • /
    • 1992
  • The offshore industry created a need for quality wet weld repairs. Wet welding is a fast method of repair providing sound, structural quality welds. It requires less support equipment than a similar underwater dry weld repair or the alternative mechanical connections. Compared to welds made in air, underwater wet welds are plagued by increased hardness due to rapid quenching by the surrounding water. In this paper is described the experimntal study of improving the cooling rates of wet welds of TMCP steel plate by shielding around weld arc surroundings. The principal results of this experimental investigation can be summarized as follows : By shielding around weld arc surrounding, the cooling rates resulting from wet welds on TMCP steel plate could be lower than that of nonshielded wet welds and the fesibility on high quality of mecanical properties of wet weld on TMCP steel plate was carried out with shielded weld arc surrounding.

  • PDF

Prediction of Tropospheric Amplitude Scintillation on Earth-Space Paths with High-Elevation Angle

  • Potilar, W.;Nakasuwan, J.;Griwan, J.;Sangaroon, O.;Janchitrapongvej, K.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.2078-2081
    • /
    • 2003
  • This paper presents the studies on prediction models of tropospheric scintillation. The prediction scintillation models are Karasawa and ITU-R , which can be improved for different locations and circumstances. In this paper, the investigation of average time between variance ${\sigma}_n\;^2$ and the wet part of refractivity $N_{wet}$ under various conditions of meteorological parameters have been carried out at King Mongkut’s Institute of Technology Lankrabang , Bangkok , Thailand , in the range of Ku-band (12.260 GHz) on high elevation angle from Thaicom2 satellite. From the studies results shows that average period of time of 30 days are best suitable for find out the relation between average time variance ${\sigma}_n\;^2$ and the wet part of refractivity $N_{wet}$ according to Karasawa model, the average time variance is express as ${\sigma}_n\;^2=(0.003N_{wet}-0.1313)^2$ , the appropriation model for occurrence of scintillation has been analyzed and experimental results are carried out.

  • PDF

Integrated Wet Oxidation and Aerobic Biological Treatment of the Quinoline Wastewater (퀴놀린 폐수의 습식산화와 호기성 생물학적 통합처리)

  • Kwon, S.S.;Moon, H.M.;Lee, Y.H.;Yu, Yong-Ho;Yoon, Wang-Lai;Suh, Il-Soon
    • KSBB Journal
    • /
    • v.23 no.3
    • /
    • pp.245-250
    • /
    • 2008
  • The treatment of a model wastewater containing quinoline in an integrated wet oxidation-aerobic biological treatment was investigated. Partial wet oxidation under mild operating conditions was capable of converting the original quinoline to biodegradable organic acids such as nicotinic, formic and acetic acid, the solution of which was subjected to the subsequent aerobic biological treatment. The wet oxidation was carried out at 250$^{\circ}C$ and the initial pH of 7.0, and led to effluents of which nicotinic acid was oxidized through 6-hydroxynicotinic acid by a Bacillus species in the subsequent aerobic biological treatment. Either homogeneous catalyst of $CuSO_4$ or phenol, which is more degradable in the wet oxidation compared to quinoline, was also used for increasing the oxidation rate in the wet oxidation of quinoline at 200$^{\circ}C$. The oxidation of quinoline in the catalytic wet oxidation and the wet co-oxidation with phenol resulted in effluents of which nicotinic acid was biodegradable earlier in the aerobic biological treatment compared to those out of the non-catalytic wet oxidation at 250$^{\circ}C$. However, the lag phase in the biodegradation of nicotinic acid formed out of the wet oxidation at 250$^{\circ}C$ was considerably shortened after the adaptation of Bacillus species used in the aerobic biological treatment with the effluents of the quinoline wet oxidation.

Integrated Wet Oxidation and Aerobic Biological Treatment of the Wastewater Containing High Concentration of Phenol (고농도 페놀 폐수의 습식산화와 호기성 생물학적 통합처리)

  • Choi, Ho-Jun;Lee, Seung-Ho;Yu, Yong-Ho;Yoon, Wang-Lai;Suh, II-Soon
    • KSBB Journal
    • /
    • v.22 no.4
    • /
    • pp.244-248
    • /
    • 2007
  • The treatment of a model wastewater containing high concentration, 10 $g/{\ell}$, of phenol in an integrated wet oxidation-aerobic biological treatment was investigated. Partial wet oxidation under mild operating conditions was capable of converting the original phenol to biodegradable organic acids such as maleic acid, formic acid and acetic acid, the solution of which was subjected to the subsequent aerobic biological treatment. The wet oxidation was carried out at 150$^{\circ}C$ and 200$^{\circ}C$ and the initial pH of 1 to 12. The high temperature of 200$^{\circ}C$ and the acidic initial condition in the wet oxidation led to effluents of which biodegradability was higher in the subsequent biological oxidation process, as assessed by chemical oxygen demand (COD) removal. Homogeneous catalyst of $CuSO_4$ was also used for increasing the oxidation rate in the wet oxidation at 150$^{\circ}C$ and initial pH of 3.0. However, the pretreatment with the catalytic wet oxidation resulted in effluents which were less biodegradable in the aerobic biological process compared to those out of the non-catalytic wet oxidation at the same operating conditions.

The Influence of Diamond Abrasive Size on the Life of Tungsten Carbide Wet Drawing Dies (다이아몬드 연마재 입도가 초경 습식신선 다이스 수명에 미치는 영향)

  • Lee, S.K.;Kim, M.A.;Ko, D.C.;Kim, B.M.
    • Transactions of Materials Processing
    • /
    • v.15 no.7 s.88
    • /
    • pp.518-523
    • /
    • 2006
  • Wet wire drawing of brass coated steel wire, used for tire reinforcement, is realized with Tungsten Carbide(WC) dies sintered with a cobalt(Co) binder. Dies wear represents an important limitation to the production process and cost savings. Several parameters, such as Co content, WC grain size of tungsten carbide, sintering conditions, and so on, affect on the wear of the drawing die. In this study, the effect of the diamond abrasive particle size on the life of the WC centered dies of the wet wire drawing was investigated. Wet wire drawing experiments were carried out on a wet wire drawing machine. From the experiments, the dies life, dies fracture, wire surface roughness, and wire breaks were investigated. From the results, it was found that the wear of the WC dies increased with the increase in the diamond abrasive particle size.

A Numerical Study on the Performance Analysis of the Plume Abatement NWD Cooling Tower (백연 방지를 위한 NWD냉각탑의 성능해석에 관한 수치해석적 연구)

  • 최창혁;최영기;소헌영
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.11
    • /
    • pp.1049-1058
    • /
    • 2001
  • The performance and design analysis for a NWD cooling tower using a combined wet and dry type fill are numerically investigated and compared with the experimental results. The Stoecker's method is applied to the wet section and LMTD or NTU-Effectiveness method to the wet and dry sections. The efficiency ratio of the NWD cooling tower to a wet type crossflow cooling tower is 59.34%. The predicted result shows a good agreement with the experimental data within 1.4% error. Plume abatement is far better with a NWD cooling tower than a counterflow cooling tower. It costs less than a conventional wet/dry tower because the finned exchanger is eliminated. This method also leaves out complexity in structure and Intricacy in operation.

  • PDF