• Title/Summary/Keyword: well pumping

Search Result 362, Processing Time 0.026 seconds

Study of the Nitrogen-Beam Irradiation Effects on ALD-ZnO Films (ALD로 성장된 ZnO박막에 대한 질소이온 조사효과)

  • Kim, H.S.
    • Journal of the Korean Vacuum Society
    • /
    • v.18 no.5
    • /
    • pp.384-389
    • /
    • 2009
  • ZnO, a wurtzite lattice structure, has attracted much attention as a promising material for light-emitting diodes (LEDs) due to highly efficient UV emission resulting from its large band gap of 3.37 eV, large exciton binding energy of 60 meV, and low power threshold for optical pumping at room temperature. For the realization of LEDs, both n-type ZnO and p-type ZnO are required. Now, n-type ZnO for practical applications is available; however, p-type ZnO still has many drawbacks. In this study, ZnO films were grown on glass substrates by using atomic layer deposition (ALD) and the ZnO films were irradiated by nitrogen ion beams (20 keV, $10^{13}{\sim}10^{15}ions/cm^2$). The effects of nitrogen-beam irradiation on the ZnO structure as well as the electrical property were investigated by using fieldemission scanning electron microscopy (FESEM) and Hall-effect measurement.

Effects of Site-scale Anisotropy of an Aquifer on Groundwater Remediation (지하수 오염복원에서 현장규모 이방성의 효과)

  • Lee, Jae-Min;Lee, Byung-Sun;Woo, Nam-Chil
    • Journal of Soil and Groundwater Environment
    • /
    • v.15 no.6
    • /
    • pp.17-28
    • /
    • 2010
  • As a preliminary survey to improve efficiency of well-based permeable reactive barrier system for groundwater remediation, this site-scale study was carried to identify the flowpaths and controlling factors of plume at a remediation site in Suwon City, Korea. A total of 22 monitoring wells were installed as a grid system in the $4m{\times}4m$ square area by 1-m interval. For the groundwater characterization, various tests were performed including water-level monitoring, water sampling & analysis, pumping and slug tests, and tracer tests. The aquifer appeared to be unconfined with hydraulic conductivities (K) ranging from $2.6{\times}10^{-4}cm/s$ to $9.5{\times}10^{-3}cm/s$. The average linear velocity of groundwater was estimated to be $2.94{\times}10^{-6}m/s$, and the longitudinal dispersivity of a conservative tracer to be $5.94{\times}10^{-7}m^2/s$. Groundwater plume moves preferentially through the high-K zones, and the relatively high ion concentrations along the low-K zones implying deterred groundwater flow. Consequently, the spatial variation of hydraulic conductivity caused by aquifer heterogeneity and anisotropy appears to be the most important factor to maximize the effect of plume treatment system for application of in-situ groundwater remediation techniques.

Estimating Exploitable Groundwater Amount in Musimcheon Watershed by Using an Integrated Surface Water-Groundwater Model (지표수지하수 통합모형을 이용한 무심천 유역의 지하수 개발가능량 산정)

  • Chung, Il-Moon;Lee, Jeong-Woo;Kim, Nam-Won
    • Economic and Environmental Geology
    • /
    • v.44 no.5
    • /
    • pp.433-442
    • /
    • 2011
  • In Korea, groundwater management has been conducted based on the estimation of annual average of groundwater recharge. Since groundwater recharge and surface water-groundwater interactions show spatiotemporal variation, continuous monitoring and dynamic analysis must be carried out to evaluate the sustainability of groundwater resources. In this study, SWAT-MODFLOW, an integrated surface water-groundwater model was used to analyze surface-groundwater interactions for various groundwater pumping scenarios in Musimcheon watershed. When current usage is applied, the baseflow reduction is about 16%, and annual averaged storage reduction is about 27 mm for whole watershed. As a holistic approach to groundwater sustainability considers the hydrological, ecological, socioeconomic, technological aspects of groundwater utilization, the exploitable groundwater should be determined by physical analysis as well as social compromise in a community.

Characteristics of the Nd:YAG laser with stimulated brillouin scattering phase conjugate mirror (유도 브릴루앙 산란 위상공액 거울을 이용한 Nd:YAG 레이저 발진기의 출력특성)

  • 이동원;이성구;박승현;공홍진
    • Korean Journal of Optics and Photonics
    • /
    • v.13 no.6
    • /
    • pp.548-553
    • /
    • 2002
  • We have investigated the output characteristics of a Nd:YAG oscillator with a Stimulated Brillouin Scattering phase conjugation mirror (SBS-PCM). FC-75 is used as an SBS gain medium and Cr:YAG (T=50%) as a Q-switcher. The SBS-PCM consists of an SBS-cell and a simple plano-convex focusing lens system. For the case of not using a Q-switcher, an SBS-cell doesn't work as a phase conjugation mirror. For the case of using a Q-switcher, the energy characteristics remains nearly the same whether using the SBS-cell or not using it. The pulse width is reduced from 50 ns to 40 ns by an SBS-PCM. When the SBS-cell is used with a Q- switcher, the SBS-cell works very well as a phase conjugation mirror and its beam-profile is improved dramatically. And in order to explain the progression of beam-profile, we propose a simple model based on the nonlinear reflectivity of the SBS-PCM, whose reflectivity is dependent on the pumping intensity at the focal plane.

Groundwater Flow Analysis Using Finite Difference Method in Volcanic Island (화산도서에서 유한차분법을 이용한 지하수 유동해석)

  • Choe, Yun-Yeong;Lee, Sun-Tak
    • Journal of Korea Water Resources Association
    • /
    • v.33 no.5
    • /
    • pp.611-622
    • /
    • 2000
  • In this study, MODFLOW model is used to analyze the groundwater flow system of Seoguipo area in Cheju island, The final parameters of permeability coefficient and storage coefficient of target area can be obtained by trial and error method using the measured data of pumping rate as initial values. And it is found that the applicability for groundwater flow system is reflected well from the simulation result of the model. Seoguipo area spring water is thought to appear by relatively stable groundwater recharge below EL. 400m according to head distribution through the analysis of observed data considering topographic and geological characteristics, Lee's study(996), and the simulation result. Also it is known that point II, III, and VI show relatively large velocity vectors, and groundwater flows through the movement path which is distributed in various directions of I, II, III, IV, V, VI, and VIl form the result of velocity vector analysis using head distribution result values to analyze the groundwater flow path under unsteady flow condition.dition.

  • PDF

Suitability Assessment and Maintenance Planning of the Guided Drainage Method on Underpass Structure (유도배수공법을 적용한 지하차도 설계 및 유지관리방안)

  • Jin, Kyu-Nam;Lee, Jung-Min;Kim, Young-Jin;Park, Jae-Hyeon;Cho, Gye-Chun
    • Land and Housing Review
    • /
    • v.3 no.1
    • /
    • pp.97-109
    • /
    • 2012
  • For the design of underpass structures, -1.0m(G.L) ground water level guideline for the design of railway, subway, utility tunnel etc, is still being used in Korea. As a result, the underpass structure can be forced by buoyancy, and therefore the in-situ buoyancy anchor method is usually being applied to prevent the uplifting force. For the Yeongjongdo sky city project, the drainage method was applied to remove the buoyancy force. In this study we estimate the efficiency and safety of the applied design and propose the detailed guidelines for standard design and maintenance of the guided drainage technique. Especially, the auxiliary pumping well was operated to maintain the ground water level around the underpass. In the study site, the applied guided drainage method has advantages in both engineering and economic aspects.

Stress field interference of hydraulic fractures in layered formation

  • Zhu, Haiyan;Zhang, Xudong;Guo, Jianchun;Xu, Yaqin;Chen, Li;Yuan, Shuhang;Wang, Yonghui;Huang, Jingya
    • Geomechanics and Engineering
    • /
    • v.9 no.5
    • /
    • pp.645-667
    • /
    • 2015
  • Single treatment and staged treatments in vertical wells are widely applied in sandstone and mudstone thin interbedded (SMTI) reservoir to stimulate the reservoir. The keys and difficulties of stimulating this category of formations are to avoid hydraulic fracture propagating through the interface between shale and sand as well as control the fracture height. In this paper, the cohesive zone method was utilized to build the 3-dimensional fracture dynamic propagation model in shale and sand interbedded formation based on the cohesive damage element. Staged treatments and single treatment were simulated by single fracture propagation model and double fractures propagation model respectively. Study on the changes of fracture vicinity stress field during propagation is to compare and analyze the parameters which influence the interfacial induced stresses between two different fracturing methods. As a result, we can prejudge how difficult it is that the fracture propagates along its height direction. The induced stress increases as the pumping rate increasing and it changes as a parabolic function of the fluid viscosity. The optimized pump rate is $4.8m^3/min$ and fluid viscosity is $0.1Pa{\cdot}s$ to avoid the over extending of hydraulic fracture in height direction. The simulation outcomes were applied in the field to optimize the treatment parameters and the staged treatments was suggested to get a better production than single treatment.

Water-hammer in the Pump Pipeline System with and without an Air-Chamber (에어챔버 설치에 따른 펌프관로계의 수격현상)

  • Lee, Sun-Kon;Yang, Cheol-Soo
    • Journal of the Korean Society of Safety
    • /
    • v.26 no.1
    • /
    • pp.1-7
    • /
    • 2011
  • When the pumps stopped in the operation by the power failure, the hydraulic transients take place in the sudden change of a velocity of pipe line. Each and every water hammer problem shows the critical stage to be greatly affected the facts of safety and reliability in case of power failure. The field tests of the water hammer executed at Cheong-Yang booster pump station having an air chamber. The effects were studied by both the practical experiments and the CFD(Computational Fluid Dynamics : Surge 2008). The result states that the system with water hammering protection equipment was much safer when power failure happens. The following data by a computational fluid dynamic analysis are to be shown below, securing the system stability and integrity. (1) With water hammering protection equipment. (1) Change of pressure : Up to $15.5\;kg/cm^2$ in contrary to estimating $16.88\;kg/cm^2$. (2) Change rate of water level : 52~33% in contrary to estimating 55~27%. (3) Note that the operational pressure of pump runs approx. 145 m, lowering 155 m of the regularity head of pump. (4) Note that the cycle of water hammering delays from 80 second to 100 second, together with easing the function of air value at the pneumatic lines. (2) Change of pressure without water hammering protection equipment : Approximate $22.86\;kg/cm^2$. The comprehensive result says that the computational fluid dynamics analysis would match well with the practical field-test. It was able to predict Max. or Min. water hammering time in a piping system. This study aims effectively to alleviate water hammering in a pipe line to be installed with air chamber at the pumping station and results in making the stability of pump system in the end.

Surface properties and interception behaviors of GO-TiO2 modified PVDF hollow fiber membrane

  • Li, Dongmei;Liang, Jinling;Huang, Mingzhu;Huang, Jun;Feng, Li;Li, Shaoxiu;Zhan, Yongshi
    • Membrane and Water Treatment
    • /
    • v.10 no.2
    • /
    • pp.113-120
    • /
    • 2019
  • To investigate surface properties and interception performances of the new modified PVDF membrane coated with Graphene Oxide (GO) and nano-$TiO_2$ (for short the modified membrane) via the interface polymerization method combined with the pumping suction filtration way, filtration experiments of the modified membrane on Humic Acid (HA) were conducted. Results showed that the contact angle (characterizing the hydrophilicity) of the modified membrane decreased from $80.6{\pm}1.8^{\circ}$ to $38.6{\pm}1.2^{\circ}$. The F element of PVDF membrane surface decreased from 60.91% to 17.79% after covered with GO and $TiO_2$. O/C element mass ratio has a fivefold increase, the percentage of O element on the modified membrane surface increased from 3.83 wt% to 20.87%. The modified membrane surface was packed with hydrophilic polar groups (like -COOH, -OH, C-O, C=O, N-H) and a functional hydrophilic GO-polyamide-$TiO_2$ composite configuration. This configuration provided a rigid network structure for the firm attachment of GO and $TiO_2$ on the surface of the membrane and for a higher flux as well. The total flux attenuation rate of the modified membrane decreased to 35.6% while 51.2% for the original one. The irreversible attenuation rate has dropped 71%. The static interception amount of HA on the modified membrane was $158.6mg/m^2$, a half of that of the original one ($295.0mg/m^2$). The flux recovery rate was increased by 50%. The interception rate of the modified membrane on HA increased by 12% approximately and its filtration cycle was 2-3 times of that of the original membrane.

A Note on Estimating and Managing Groundwater Reserves (지하수 부존량 평가와 관리에 대한 소고)

  • Lee, Byung Sun;Park, Jong Hwan;Myoung, Wooho;Son, Joohyeong;Lee, Sanghaw;Shim, Gyuseong;Song, Sung-Ho
    • Journal of Soil and Groundwater Environment
    • /
    • v.23 no.6
    • /
    • pp.28-36
    • /
    • 2018
  • This study was conducted to estimate groundwater reserves within a designated depth. Three methods were applied to one representative county in southern Gyeongsang province, South Korea, to estimate the groundwater reserves in the aquifers. Estimated amounts of groundwater reserves in the region ranged from $20.2{\times}10^9m^3$ to $68.7{\times}10^9m^3$ (average $37.9{\times}10^9m^3$). Groundwater recharge obtained with a recharge ratio of 16.6% was $1.1{\times}10^9m^3/year$. Exploitable groundwater with an assumption of decadal-cycle minimal rainfall of 977.0 mm/year was approximated as 72% ($0.8{\times}10^9m^3/year$) of the total replenished water by recharge. The volume of recharge and exploitable water accounted for only 1.1% and 0.8% of groundwater reserves, respectively, which indicates substantial capacity of the reservoir to supply groundwater in an event of unexpected droughts. Nonetheless, each groundwater well should strictly comply with its allocated pumping rate to avoid alluvial groundwater depletion.