• Title/Summary/Keyword: wedge-type aquifer

Search Result 1, Processing Time 0.013 seconds

Hydrogeologic Property of Bedrock Aquifer of Mockcheon Area Applying Several Pumping Test Analyses (여러 가지 양수시험분석방법 적용을 통한 목천지역 암반대수층의 수리지질학적 특성)

  • 강래수;함세영;최성자;이병대
    • The Journal of Engineering Geology
    • /
    • v.13 no.1
    • /
    • pp.67-82
    • /
    • 2003
  • Pumping test data obtained from five natural mineral-water producing companies (Siwon Saemmul, Daejeong Eumryo, Jain Guanguang, Cheongsu Eumryo and Hanju Sikpum) that are located within 1 km radius around Mockcheon area were analyzed. Theis(1935), Papadopulos-Cooper(1967), Hantush(1960, 1962), Hantush-Jacob(1955), Moench(1985), Neuman-Witherspoon(1969), Gringarten-Witherspoon(1969) and Gringarten-Ramey(1974) equations were applied to the pumping test analysis. The result of the pumping test analysis shows that wedge-typed confined aquifer model (Hantush, 1962) and leaky confined aquifer Case-1 model (Moench, 1985) were suitable for the study area. The models match well with geologic structure in the study area which controls aquifer by means of two major thrust faults having Nl8E and NS strikes, respectively.