• Title/Summary/Keyword: wedge

Search Result 1,451, Processing Time 0.113 seconds

The Effect of the Wedge Insole Angle of Supinated Group on Foot Contact Time, Foot Contact Area and Foot Pressure (회외족의 Wedge Insole 각에 따른 보행 시 접지 시간, 접지면적 및 족저압력의 비교)

  • Lee, Hyo-Taek;Kim, Yong-Jae
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.22 no.4
    • /
    • pp.508-515
    • /
    • 2010
  • This study was conducted on male college students with supinated foot to measure the foot pressure by having them wear three kinds of wedge insoles ($0^{\circ}$, $3.5^{\circ}$, $7^{\circ}$). Foot contact time, foot contact area, peak pressure and mean pressure were measured using a foot pressure distribution measuring instrument. And the surface of the foot sole was divided into 10 areas. Regarding foot contact time, there was no statistically significant difference by showing $0.69{\pm}0.004$ seconds at $3.5^{\circ}$ and $0.68{\pm}0.006$ seconds at $0^{\circ}$ and $7^{\circ}$. Regarding the foot contact area, it appeared broad in the inside area of the foot according to wedge insole, and there was statistically significant difference in the area 1 of the rear foot(p< .01) and the area 3 of the middle foot(p< .05). The peak pressure by foot area decreased in the outside of the foot according to wedge insole, while increasing in the inside of the foot. Among the areas, there was statistically significant in the area 2 of the rear foot (p< .01) and the area 3 of the middle foot (p< .05). Regarding the mean pressure by foot area, the pressure roughly increased in the inside area of the foot according to wedge insole, while decreasing in the outside of the foot.

Relationship between the Initial Clamping Force and the Proper Position of Supporter in the Wedge Type Rail Clamp (쐐기형 레일클램프에서 초기압착력과 지지대의 적정위치사이의 관계)

  • Han, Dong-Seop;Lee, Seong-Wook;Han, Geun-Jo;Lee, Kwon-Soon
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • v.1
    • /
    • pp.357-362
    • /
    • 2006
  • The wedge type rail clamp compresses with small clamping force at first, and with large clamping force when the wind speed increases because of the wedge working. At this time in order to display the wedge working, the rail clamp slips along a rail. If the supporter is not installed in the rail clamp when the wind speed increases more and more, the structure will occur overload which leads the structure to fracture. So the supporter has to be installed in the rail clamp. The proper position of this supporter is determined by the initial clamping force and the wege angle. Therefore in this study we adopted 5-kinds of wedge angle as the design parameters, and carried out the finite element analysis, in order to analyze the relationship between the initial clamping force and the proper position of supporter in the wedge type rail clamp.

  • PDF

Relationship between the Initial Clamping Force and the Position of Supporter in the Wedge Type Rail Clamp (쐐기형 레일클램프에서 초기압착력과 지지대의 위치사이의 관계)

  • Lee, Seong-Wook;Han, Geun-Jo;Lee, Kwon-Soon;Han, Dong-Seop
    • Journal of Navigation and Port Research
    • /
    • v.31 no.1 s.117
    • /
    • pp.65-70
    • /
    • 2007
  • The wedge type rail clamp compresses with small clamping force at first, and with large clamping force when the wind speed increases bemuse of the wedge working. At this time in order to display the wedge working, the rail clamp slips along a rail. If the supporter is not installed in the rail clamp when the wind speed increases more and more, the structure will occur overload which leads the structure to fracture. So the supporter has to be installed in the rail clamp. The proper position of this supporter is determined by the initial clamping force and the wege angle. Therefore in this study we adopted 5-kinds of wedge angle as the design parameters, and carried out the finite element analysis, in order to analyze the relationship between the initial clamping force and the position of supporter in the wedge type rail clamp.

A Study on the Variation of Transmission Factors, Output Factors and Percent Depth Doses by Wedge Filters for 4~10 MV X-Ray Beams (4~10 MV X-선의 쐐기 (wedge) 필터의 투과율과 출력계수, 선축상 선량분포의 변화에 관한 연구)

  • 강위생
    • Progress in Medical Physics
    • /
    • v.8 no.2
    • /
    • pp.3-17
    • /
    • 1997
  • Because a wedged beam consists of attenuated primary photons and scattered radiations from wedge, the spectrum of the wedged beam does not coincide with that of an open beam with same geometry. The aims of current report are to get exact information about whether effects of 15-60$^{\circ}$ wedge for 4 -10 MV photon beams should be considered for dose calculation or not, and to suggest a reference condition for measurement of wedge transmission factor. Percent depth dose of both open and wedged fields with angles of 15, 30, 45, 60$^{\circ}$ for beams of 4 MV(Clinac 4/100, Varian), two 6 MV(Clinac 6/100 and Clinac 2100C, Varian), 10 MV(Clinac 2100C, Varian) X-rays were measured to 30cm deep in water using ionization chambers. Hardening factors of photon beams were calculated with measured PDDs. Both field size factors and transmission factors of wedge filters were measured at d$_{max}$ in water. Beam hardening factors of wedged fields of 4 and 6 MV X-ray were larger than 1 for all wedge angles, field sizes and depths deeper than d$_{max}$ Beam hardening factors for wedge angles 15, 30, 45, 60$^{\circ}$ for 10$\times$10cm were respectively 1.010, 1.014, 1.023 and 1.034 for 4MV X-ray, 1.005, 1.008, 1.019, and 1.024 for 6MV X-ray of Clinac 6/100, 1.011, 1.021, 1.032, 1.036 for 6MV X-ray of Clinac 2100C, and 1.008, 1.012, 1.012 and 1.012 for 10MV X-ray. Beam hardening factors of 10MV X-ray were 1 within 1.2% difference for all wedge angles, depths and field sizes. It was made clear that for 6MV X-rays, the beam hardening factor depends on treatment machine. The relationship of the factor and depth was linear. Field size factor at d$_{max}$ was independent of wedge angle except for the field of 15$\times$15cm. and maximum difference of the field size factors for the field size was 1.4% for 4MV X-ray. When the wedge factor is determined, dependence of the factor on field size is negligible at d$_{max}$ but should be considered at deeper depth. Calculating dose distribution or MU, the beam hardening factor should be applied for 4~6MV X-ray beams, but might not be considered for 10MV beam. When wedge transmission factor was determined at d$_{max}$ or in air, field size factors for open field are also applicable to wedged fields, but otherwise, field size factor for each wedge or wedge factor depending on field size should be applied.

  • PDF

Dose Distribution of Wedge filter by Dose Rate in LINAC (선형가속기의 선량율에 따른 쐐기필터의 선량분포)

  • Gwon, Taehyeong;Kim, Seunguk;Yoon, Yonghak;Won, Doyeon;Jeong, Kyeonghwan;Jung, Jaeeun;Cho, Juneho
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.5
    • /
    • pp.323-329
    • /
    • 2015
  • This study is aimed at assessing whether dynamic wedge filters are appropriate to be used instead of physical wedge filters. The X-ray energy generated from linear accelerator is commercialize 6 MV and 10 MV. $15^{\circ}$, $30^{\circ}$, $45^{\circ}$, and $60^{\circ}$ of physical wedge filter was irradiated by dose rate 100, 200, 300, 400, 500, and 600 MU/min for each angle and for comparison with a dynamic wedge filter, irradiate 96 times under the same conditions. The measurement conditions are as 100 cm source-film distance and $10{\times}10cm$ irradiated surface. A developed film was scanned and analyzed after a calibration through a dose analysis program and the dose rate was compared after calculating the standard deviation. Dynamic wedge filters make dose, scattered rays and treatment time reduced and very useful due to less irradiated doses to patients. The errors at each dose rate under the same conditions were irrelevant. Thus, treatment based on a high dose rate depending on the patient is expected to be feasible.

The Effect of Control-Ownership Wedge on Stock Price Crash Risk (소유지배 괴리도가 주가급락위험에 미치는 영향)

  • Chae, Soo-Joon;Ryu, Hae-Young
    • The Journal of Industrial Distribution & Business
    • /
    • v.9 no.7
    • /
    • pp.53-59
    • /
    • 2018
  • Purpose - This study examines the effect of control-ownership wedge on stock crash risk. In Korea, controlling shareholders have exclusive control rights compared to their cash flow rights. With increasing disparity, controlling shareholders abuse their power and extract private benefits at the expense of the minority shareholders. Managers who are controlling shareholders of the companies tend not to disclose critical information that would prevent them from pursuing private interests. They accumulate negative information in the firm. When the accumulated bad news crosses a tipping point, it will be suddenly released to the market at once, resulting in an abrupt decline in stock prices. We predict that stock price crash likelihood due to information opaqueness increases as the wedge increases. Research design, data, and methodology - 831 KOSPI-listed firm-year observations are from KisValue database from 2005 to 2011. Control-ownership wedge is measured as the ratio (UCO -UCF)/UCO where UCF(UCO) is the ultimate cash-flow(control) rights of the largest controlling shareholder. Dependent variable CRASH is a dummy variable that equals one if the firm has at least 1 crash week during a year, and zero otherwise. Logistic regression is used to examine the relationship between control-ownership wedge and stock price crash risk. Results - Using a sample of KOSPI-listed firms in KisValue database for the period 2005-2011, we find that stock price crash risk increases as the disparity increases. Specifically, we find that the coefficient of WEDGE is significantly positive, supporting our prediction. The result implies that as controlling shareholders' ownership increases, controlling shareholders tend to withhold bad news. Conclusions - Our results show that agency problems arising from the divergence between control rights and cash flow rights increase the opaqueness of accounting information. Eventually, the accumulated bad news is released all at once, leading to stock price crashes. It could be seen that companies with high control-ownership wedge are likely to experience future stock price crashes. Our study is related to a broader literature that examined the effect of the control-ownership wedge on stock markets. Our findings suggest that the disparity is a meaningful predictor for future stock price crash risk. The results are expected to provide useful implications for firms, regulators, and investors.

Dose Calculation of Photon Beam with Wedge Filter for Radiation Therapy Planning System

  • Cheong, Kwang-Ho;Suh, Tae-Suk;Lee, Hyoung-Koo;Choe, Bo-Young
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2003.09a
    • /
    • pp.41-41
    • /
    • 2003
  • Purpose: Even if the wedge filter is widely used for the radiation therapy to modify the photon beam intensity, the wedged photon beam dose calculation is not so easy. Radiation therapy planning systems (RTPS) have been used the empirical or semi-analytical methods such as attenuation method using wedge filter parameters or wedge filter factor obtained from measurement. However, these methods can cause serious error in penumbra region as well as in edge region. In this study, we propose the dose calculation algorithm for wedged field to minimize the error especially in the outer beam region. Materials and Method: Modified intensity by wedge filter was calculated using tissue-maximum ratio (TMR) and scatter-maximum ratio (SMR) of wedged field. Profiles of wedged and non-wedged direction was also used. The result of new dose calculation was compared with measurement and the result from attenuation method. Results: Proposed algorithm showed the good agreement with measurement in the high dose-gradient region as well as in the inner beam region. The error was decreased comparing to attenuation method. Conclusion: Although necessary beam data for the RTPS commissioning was increased, new algorithm would guarantee the improved dose calculation accuracy for wedged field. In future, this algorithm could be adopted in RTPS.

  • PDF

Design of the Various Capacity Wedge-type Rail Clamp for a Quay crane According to the Design Wind Speed Criteria Change (설계 풍속 상향 조정에 따른 Quay crane용 제용량 쐐기형 레일 클램프 설계)

  • Lee J.M.;Han G.J.;Shim J.J.;Han D.S.;Lee S.W.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1626-1629
    • /
    • 2005
  • Recently many countries have concentrated their effort on the port automation, in order to be the Hub-port, that the Ultra Large Container Ship could come alongside the Quay, in their region. As the magnitude of the container ship increase, that of the Quay crane increases from 50ton-class to 61ton-class more and more. The wind speed criteria to design the structures used in the port was upgraded from 20m/s to 40m/s due to change of the weather condition. Our laboratory could have the ability to design the wedge type rail clamp for 50ton-class Quay crane in 30m/s wind speed. Accordingly we analyzed the load condition of the Quay crane about 40m/s wind speed upgraded from 20m/s and designed the wedge type rail clamp for 50ton and 61ton-class Quay crane.

  • PDF

Behaviors of Anisotropic Fluids in the Vicinity of a Wedge

  • Kim, Youn-J.
    • Journal of Mechanical Science and Technology
    • /
    • v.14 no.6
    • /
    • pp.690-698
    • /
    • 2000
  • The laminar boundary layer flow and heat transfer of anisotropic fluids in the vicinity of a wedge have been examined with constant surface temperature. The similarity variables found by Falkner and Skan are employed to reduce the stream wise-dependence in the coupled nonlinear boundary layer equations. The numerical solutions are presented using the fourth-order Runge - Kutta method and the distribution of velocity, micro-rotation, shear and couple stresses and temperature across the boundary layer are plotted. These results are also compared with the corresponding flow problems for Newtonian fluid over wedges. It is found that for a constant wedge angle, the skin friction coefficient is lower for micropolar fluid, as compared to Newtonian fluid. For the case of the constant material parameter K, however, the magnitude of velocity for anisotropic fluid is greater than that of Newtonian fluid. The numerical results also show that for a constant wedge angle with a given Prandtl number, Pr = I, the effect of increasing values of K results in increasing thermal boundary layer thickness for anisotropic fluid, as compared with Newtonian fluid. For the case of the constant material parameter K, however, the heat transfer rate for anisotropic fluid is lower than that of Newtonian fluid.

  • PDF