• Title/Summary/Keyword: wearing surface

Search Result 195, Processing Time 0.023 seconds

A Study on the Fatigue Phenomena of Woven Fabrics -On the Changes of Mechanical Properties and Handle of Woven Fabrics Caused by the Wearing- (직물의 피노에 관한 연구 -착용에 의한 역학적 성질과 태의 변화-)

  • Suh Young Sook
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.10 no.1
    • /
    • pp.47-57
    • /
    • 1986
  • The purpose of this study is to investigate fatigue phenomema of woven fabric. In order to obtain the basic data which is available for predicting the fabric fatigue phenomena, the change of mechanical properties of woven fabrics caused by the wearing and the changes of mechanical properties of woven fabrics which were subjected to repeated tensile-shearing deformation using fabric testing machine has been investigated and compared. The fatigue of woven fabrics was examined with the value of basic mechanical properties of specimens measured by the KES-F fabric testing system and their hand value and wearing ability. The results were as follows. 1) The fatigue phenomena of woven fabrics by the wearing for 800 hours are different on the position of the body: On the portion of hip, the change of surface property was the greatest, bending hysterisis was greatly increased, thickness weight, stiffness, fullness shearing hysterisis were more increased than original fabric and T.H.V. was decreased. On the portion of knee, decreasing of tensile resilience and increasing of bending, shearing hysterisis were observed greater than any other part, and increasing of stiffness, crispness was more than original fabric. On the bottom area, the changes of mechanical property was comparatively small, H.V. and T.H.V. showed near the value of the original fabric. 2) By drycleaning most of mechanical properties showed the tendency to recover the value of the original fabric, but bending hysterisis and thickess were increased, tensile and com-pression resilience were decreased more than original fabric in all parts. 3) The fatigue phenomena caused by fabric fatigue testing machine were as follows. The decreasing of hystersis in the repeated deformation such as bending, shearing was appeared at the $10^2$ deformation, but with the increasing cycle, the tendency was slightly regained. Handle value was also appeared the lowest value at the $10^2$ deformation.

  • PDF

AN ELECTROMYOGRAPHIC STUDY ON THE TREATMENT OF BRUXISM AND TEMPOROMANDIBULAR JOINT DYSFUNCTION PATIENTS (Bruxism과 악관절(顎關節) 기능장애자(機能障碍者)의 치료(治療)에 관(關)한 근전도학적(筋電圖學的) 연구(硏究))

  • Ro, Chang-Sup;Choi, Boo-Byung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.22 no.1
    • /
    • pp.85-94
    • /
    • 1984
  • The purpose of this study was to investigate treatment effectiveness of TENS and bite plane for bruxism and TMJ dysfunction patients. The electromyograms were made on males aged 23 to 25 with sound stomatognathic system, 5 males bruxism aged 24 to 27, and 1 male and 4 females TMJ dysfunction patients (right TMJ pain) aged 14 to 33. The electromyographic study was limited to the middle of masseter muscle and anterior temporal muscle. The electromyographic study was carried out with 8-channel EM2 (Myotronics Research Inc.) and was taken 5 mandibular positions of clinical rest position, clench intercuspal position, clench protruded, cluch right, clench left. The 2 pairs of surface electrodes were used exactly, with the ear lobe as reference point. The recording were subjected to determine the mean voltage. The results were as follows; 1. In the clinical rest position, the muscle activities of bruxism and TMJ dysfunction patients were higher than those of normal at the before treatment, but that were lower or similar to those of normal at the TENS after and after bite plane wearing. 2. In the clench I.C.P., the muscle activities of TMJ dysfunction patients were decreased as the order of the before treatment, after TENS, after occlusal bite plane wearing, but those of bruxism were irregular. 3. In the clench right and the clench left, the muscle activities of the middle of masseter muscle of the non-working side of bruxism were higher than those of the working side at the before treatment and after TENS, but the muscle activities of after occlusal bite plane wearing were similar to those of the normal. 4. In the clench right and the clench left, the muscle activities of the middle of masseter muscle and anterior temporal muscle of the working side of TMJ dysfunction patients were higher than those of non-working side as like the normal at the before treatment, after TENS, and after occlusal bite plane wearing.

  • PDF

Studies on Garment Restraint (IV) -Effect of Slacks Restraint on Lower Extremity- (의복의 구속성에 관한 연구 (IV) -슬랙스 착용시의 하지부 압박을 중심으로-)

  • 심부자;최선희
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.18 no.3
    • /
    • pp.387-394
    • /
    • 1994
  • Journal of the Korean Society of Clothing and Textiles Vol. 18, No. 3 (1994) p. 387∼394 In this study, the restriction of slacks (blue jean) versus box pleats skirt was investigated, from the view point of peripheral blood flow at the toe according to motion variation and E.M.G. analysis of leg muscles after walking on the flat or going up and down stairways. Besides, the pressure of slacks on the lower extrimity was measured statically and dynamically. The main results were summerized as follows; 1. The clothing pressure applied by slacks was; each one of thigh and lower leg was 18.2 g/ cm2 and 22.1 g/cm2 in upright, 63.4 g/cm2 and 26.6 g/cm2 in sitting on the chair, on both sides of thigh and lower leg 272.0 g/cm2 over in squatting. 2. When the motion starts from upright, the dynamic clothing pressure reach their peak before the motions end. When the motion ends and the body comes to a still condition, the clothing pressure grow lower and indicate a constant value. but when the body starts moving again to return to upright, the pressures once grow higher and go to zero value after reaching the peak. The pressure on the knee show much greater than those on the hip. This can be because these pressures depend on the degree of skin stretching motion and of its curvature. 3. The surface E.M.G. in leg muscles M. rectus femoris and M. gastrocnemius were recoreded. In the case of wearing slacks, two muscles were activated much more than wearing skirt. 4. The peripheral blood flow at the toe by wearing slacks was lower than wearing skirt. Also the case when squatting, the peripheral blood flow at the toe was low.

  • PDF

Physiological Responses of Wearing Industrial Gaiters in a Hot Environment (더운 환경에서 산업용 각반 착용 시 인체생리반응)

  • Choi, Jeong-Wha;Park, Joon-Hee
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.32 no.7
    • /
    • pp.1129-1136
    • /
    • 2008
  • The gaiter is one of the personal protective equipments worn in various industrial sites. This study was performed on humans to investigate the physiological strain of wearing gaiters and to compare control gaiters that are currently on the market and new gaiters that are developed for alleviating heat stress. Experiments were conducted in a climatic chamber of WBGT $30.0\pm0.7^{\circ}C$ under five differed experimental conditions: None, Control A, Control B, New A, New B. The results were as follows. The temperature inside gaiters was significantly lower in both New A and New B than in both Control A and Control B and the difference between news and controls was 1$^{\circ}C$ (p<.01). The humidity inside gaiters in both New A and New B were higher than that in Control A, and lower than that in Control B (p<.01). The outermost surface temperature of the gaiter was the lowest in None and it increased in the following order: New B < New A < Control A < Control B. Mean skin temperature was higher by 0.14$^{\circ}C$ in wearing gaiters than in no gaiters. Skin temperatures in lower body were lower in Control than in New and skin temperature in upper body were higher in Control than in New (p<.01). Local sweat rate, total weight loss and subjective sensations did not show a significant difference according to the gaiters. It was concluded that wearing gaiters affected distribution of skin temperature and local sweat rate.

A Study on a Men's Dress Shirt Pattern by Somatotype for Mass Customization System (대량맞춤 생산체계를 위한 체형별 남성 드레스셔츠 패턴연구)

  • Jang, Sung-Eun;Chang, Jee-Hae
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.32 no.2
    • /
    • pp.294-306
    • /
    • 2008
  • The purpose of this study is a men's dress shirt pattern by somatotype for mass customization system that is rising to the surface as a new production system. Subjects were 65 men aged from 25 to 44 for making research pattern and 9 men for wearing test. The dress shirt went through the secondary wearing test and sensory evaluation to verify the propriety of the research pattern. The results were as follows: For making research dress shirts pattern used the body parts size that were height, the circumference of the neck, the chest circumference, the length between biacromion, the arms length, and the waist circumference. The waist back length, the waist to hip length and the pattern length of were set by the calculation formula based on the height. The ease of 16cm for the chest circumference and A type had the ease of 10cm for the waist circumference, Y type had the ease of 8cm and B type had 12cm. Through the wearing test, the research pattern showed significant difference from the comparative patterns so additional two items of the length between biacromion and waist circumference were added to the items used in the comparative patterns through which satisfactory results were obtained. In the secondary wearing test for the dress shirt, all the items, except for the front centerline, were evaluated excellent. As a result of evaluating by the figure type, the normal type was evaluated best in all the items.

Effects of Heel-insole on Static Balance and Postural Strategy during External Perturbation in Healthy Young Men

  • Kang, Cheol-Jin;Oh, Duck-won;Son, Sung Min
    • The Journal of Korean Physical Therapy
    • /
    • v.33 no.1
    • /
    • pp.1-6
    • /
    • 2021
  • Purpose: This study examined the effects of heel insoles on the static balance and leg muscle activity and posture control strategy during external perturbation. Methods: Thirty healthy young men participated in the study. The subjects underwent two experimental conditions: 1) no heel insole condition (0cm) and 2) wearing heel insole condition (5cm). The static balance was measured using an I-Balance device, which measured the change in the center of gravity (COG). The onset time of muscle activation and muscle activation of the erector spinae (ES), hamstring (HAM), gastrocnemius (GCM) were measured using surface EMG electrodes to determine the change in posture control strategy during external perturbation. Results: The speed and distance of COG were significantly higher in the wearing heel insoles condition than the no heel insole condition (p<0.05). In addition, significant differences in the onset time of the GCM, HAM, and ES muscle activation were observed when there was no heel insole condition during external perturbation (p<0.017). On the other hand, no significant differences in the onset time of muscle activation were observed between GCM and HAM when wearing the heel insole condition during external perturbation (p<0.017). Moreover, muscle activation of the GCM was significantly higher in the wearing heel insoles condition than the no heel insole condition during external perturbation (p<0.05). Conclusion: These findings suggest that heel insoles may have disadvantages, and increased efforts are needed to maintain balance and change the posture control strategy during external perturbation.

Adaptive Postural Control for Trans-Femoral Prostheses Based on Neural Networks and EMG Signals

  • Lee Ju-Won;Lee Gun-Ki
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.6 no.3
    • /
    • pp.37-44
    • /
    • 2005
  • Gait control capacity for most trans-femoral prostheses is significantly different from that of a normal person, and training is required for a long period of time in order for a patient to walk properly. People become easily tired when wearing a prosthesis or orthosis for a long period typically because the gait angle cannot be smoothly adjusted during wearing. Therefore, to improve the gait control problems of a trans-femoral prosthesis, the proper gait angle is estimated through surface EMG(electromyogram) signals on a normal leg, then the gait posture which the trans-femoral prosthesis should take is calculated in the neural network, which learns the gait kinetics on the basis of the normal leg's gait angle. Based on this predicted angle, a postural control method is proposed and tested adaptively following the patient's gait habit based on the predicted angle. In this study, the gait angle prediction showed accuracy of over $97\%$, and the posture control capacity of over $90\%$.

The Effect of Circle Contact Lens on the Stability of Tear Film (써클콘택트렌즈가 눈물막 안정성에 미치는 영향)

  • Lee, Sehee;Hyung, Sung Min;Koh, Seung Hwan;Park, Mijung;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.2
    • /
    • pp.125-131
    • /
    • 2015
  • Purpose: The effect of pigmentation in circle contact lens on lens wearers' tear film stability was investigated in this study. Methods: Non-invasive tear film break-up times of 54 normal eyes before and after lens wearing in twenties and the portion of first tear breakup were measured. The frontal and back surface roughness of circle contact lens was further observed with a scanning electron microscope. The clear lens which was made of hilafilcon B and circle contact lenses which were made of hilafilcon B, polymacon and copolymer of HEMA NVP were tested. Results: Non-invasive tear film breakup time was significantly reduced compared with it before lens wearing. In some case, statistically significant difference in tear film breakup time was also observed between circle contact lenses. The tear file break-up was usually early started in lower than upper portion, and in temporal than nasal portion although there was variation in the lens material. The tear film break-up of circle contact lenses made of hilafilcon B was more commonly observed in peripheral portion(pigmented area) compared with clear contact lens made of same material. Conclusions: The present study revealed that the stability of tear film was affected by wearing circle contact lens and the result seems to be used as the basis for the problem solving that can occur due to the pigmentation when wearing circle contact lens.

Changes in Subjective/Objective Symptoms and the Light Transmissibility of Lens Associated with Overusage of Daily Disposable Circle Contact Lenses in Normal Eyes (일회용 써클소프트렌즈의 초과 착용에 의한 정상안의 자·타각적 증상 및 렌즈 광투과율의 변화)

  • Park, Mijung;Kwon, Hae Lim;Choi, Sae Ah;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.4
    • /
    • pp.429-439
    • /
    • 2013
  • Purpose: This study was assessed to investigate the change of subjective and/or objective symptoms and the light transmissibility of lens caused by over-usage of daily disposable circle contact lenses (circle lens). Methods: Three daily disposable circle lenses made of etafilcon A, hilafilcon B, and nelfilcon A were applied on 20 normal eyes free from any eye diseases by when subjects complained any kind of discomfort. On the first and the last days of lens wearing, subjective discomfort, blinking rate, non-invasive break-up time, lens centration on corneal surface and visible light transmissibility of lens were recorded at every case and compared. Results: The circle lens wearers complained discomfort when they wore the circle lens more than 15 hours, in excess of 8 hours being the recommended wearing time and the most circle lens wearers quit the lens wearing when they wore more than 30 hours. On the last day of lens wearing, the representative subjective discomforts were stiffness, dryness and tiredness. When the subjects wore circle lens more than the recommended time, a tendency of increased blinking rate and decreased NIBUT was observed when it compared with the values right after lens wearing. On the last day of lens wearing, the lens centration was shown to be decentrated from the pupil center compared with the centration right after the wearing. These changes in lens centration and blinking rate were consistently shown in all cases of lens wearing however, the difference in the degree of subjective and/or objective change was present depending on lens materials and subjects. The visible light transmissibility of circle lens has largely been changed. Conclusions: From these results, it was thought that the decreased NIBUT induced dryness and stiffness and decreased visible light transmissibility caused more blinking when daily disposable circle lens was exceedingly used, which provoked lens decentration and subjective discomfort. However, the difference of subjective and/or objective change was largely varied in accordance with the lens material types and individuality and thus it may occur some unexpected problems by the individual base. Therefore, the education about the necessity to comply with the recommended wearing time and the problem will be essential.

Wearing Quality Promotion underwear which application of Aroma capsule (Aroma microcapsule 특수가공을 이용한 underwear의 착용성 증진 방안)

  • 이의정
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.3 no.2
    • /
    • pp.63-73
    • /
    • 2001
  • Underwears treated by aroma capsule(UTA) have been known to have many advantages than normal underwears, for example, UTA has antimicrobial and deodorant properties. In this experiment, we examined antimicrobial and deodorant effect of UTA treated by rose and lemon fragrance, Mechanical properties of UTA including surface property, bending property and shear property were also tested. The results are as follows,1. The effects of antibacterial is estimated as 33% and the efficiency of deodouration is about 95 % in UTA. 2. The fragrance of UTA maintained even after 25 times washout. 3. Bending and shear properties were not changed in UTA However it decreased the coefficient of friction of the textures and the smooth surface was detected when the human skin was contacted.

  • PDF