• Title/Summary/Keyword: wearing effect wearing type

Search Result 83, Processing Time 0.032 seconds

The Effects of Neck Traction and Foot Type on Plantar Pressure Distribution during Walking (경추 견인기 부착 여부에 따른 발 형태별 보행 시 족저압에 미치는 영향)

  • Hong, Miran;Yi, Kyoungock
    • Korean Journal of Applied Biomechanics
    • /
    • v.30 no.4
    • /
    • pp.321-335
    • /
    • 2020
  • Objective: The purpose of this study was to investigate the effect of neck traction and foot type on plantar pressure distribution during walking. Method: Total of 24 data were collected from women working with a computer for more than 6 hours every day. Three groups by foot type were divided: Pes Planus, normal foot, and Pes Cavus. Depending on the foot type and cervical traction, plantar pressure variables were measured; CA, MF, PP, and CT. Each variable was divided into 12 masks. MANOVA was performed for the difference of plantar pressure variables by foot type, and a paired t-test was performed for the cervical traction within groups. Results: The total CA decreased in the Pes Planus (p<.001) and Pes Cavus (p<.05) groups. MF increased in the big toe (p<.01) and 2nd toe (p<.05) of the normal foot, and MF-3rd metatarsal decreased (p<.01). The MF-2nd toe (p<.01) and 3rd toe (p<.05) of Pes Cavus decreased. The PP decreased in 2nd toe (p<.05), 3rd toe (p<.01), and 4th toe (p<.05) of the Pes Cavus. In normal foot, the PP-3rd metatarsal (p<.05) and PP-4th metatarsal (p<.01) reduced. In Pes Planus, PP decreased in the hindfoot (p<.05). In Pes Cavus group wearing a neck-tractor, the CT-hindfoot increased (p<.05). Conclusion: There was a significant change in the plantar pressure change by foot type after neck traction. When walking with a neck-tractor, the heel impact was alleviated in the Pes Planus, and the Pes Cavus showed the smooth and effective propulsion in the push-off. Overall, weight acceptance was effectively performed when walking with neck-traction. It was also found that the neck-tractor corrects the alignment of the neck, thereby creating a more stable gait pattern.

Product Analysis and Development of Amblyopia Eye Patch for Children

  • Lim, Hosun;Sung, Juyoung
    • Fashion, Industry and Education
    • /
    • v.14 no.2
    • /
    • pp.1-10
    • /
    • 2016
  • In the present study, the materials, sizes, and designs of blind eye patch products of skin-adhesive type and glass-attachment type currently available in the market will be analyzed and ergonomically appropriate blind eye patches will be developed. Although these skin-adhesive type eye patches were easy to use, they had shortcomings such as skin troubles due to the adhesive used on the weak and sensitive skin of children and the fact that eyebrows are pulled out and the skin is irritated when the eye patches are detached after being attached. The non-adhesive type eye patches were blind patches to be worn by putting into glasses. These products were made using diverse materials such as neoprene, non-woven fabrics, and felt and showed differences in tactile impressions and irritation to the skin depending on material characteristics. In addition, most products were efficient in blocking light with three-dimensional oval designs comprising darts. In the present study, blind eye patches were designed to reduce skin troubles by using sweat-absorbing and quick-drying functional materials with soft tactile impressions. In addition, to increase the effect to block light and the degree of tight contact with the skin when the blind eye patches are worn compared to existing eye patch designs, the sides of the wings of the blind eye patches were widened, glass frame fixing plates were added, and the darts were made to be curved thereby making an ergonomic design reflecting the shape of the face. The non-adhesive type blind eye patches developed in the present study are considered to enhance the wearing sensation with the use of the material without skin irritation but with cushioning feelings and the ergonomic design reflecting the contour of the face.

Development of Men's suit Easy-Order Prototype using Cyber Fitting 3D Avatar (Cyber Fitting형 3D 아바타를 활용한 신사복 이지오더(Easy-Order) 프로토타입(Prototype) 개발)

  • Lim, Ji-Young
    • Fashion & Textile Research Journal
    • /
    • v.11 no.2
    • /
    • pp.308-314
    • /
    • 2009
  • In creating an avatar, consumers can find out for themselves their own sizes to be entered. Also, putting in a face creation main-page menu option enables clients to make up their faces and match them to their bodies. Through this process when purchasing clothes through the internet consumers can enter their own body sizes and create avatars that are identical to their body shape. The uniqueness of developed prototype is that it creates an avatar similar to one's body shape according to body size inputs and demonstrates visually to customers the on-line comfort test which was only available off-line traditionally. The avatar follows the movement of mouse from left to right which enables 3 dimensional visualization. Through maximizing the visual effect this research focuses on enabling consumers to feel subjective parts as if they are off-line. This study seeks to provide a type of prototype of an online shopping mall that meets the demand of the consumers using the 3D avatar.

EMG Activities of Vastus Muscles are Related to the Shoe-heel Heights in Female Patients with Patellofemoral Pain

  • Chon, Seung-Chul;Lee, Byung-Ki;Yoon, Tae-Hyung
    • International Journal of Contents
    • /
    • v.6 no.1
    • /
    • pp.41-46
    • /
    • 2010
  • The aim of this study was to investigate the effect of different shoe-heel heights on the surface electromyographic (EMG) activity of vastus medialis (VM) and vastus lateralis (VL) during treadmill walking in female patients with patellofemoral pain (PFP). Nineteen women with PFP participated in this research. EMG signals were recorded from the VM and VL of both sides and were compared during the treadmill walking. The subjects walked on a treadmill wearing shoes of three different heel heights: 1 cm, 3 cm and 7 cm. Each subject walked on a treadmill for five minutes at a speed of 2 km/hour with three minutes resting intervals between consecutive trials. The data were analyzed by one-way repeated-measures analysis of variance. The results of the present study indicate that EMG data of the VM and VL of female patients with PFP did improve with an increase in the height of the shoe heel, which were statistically significant. Additionally, the EMG activity of VM increased more dramatically than that of VL associated with the task of walking with high-heeled shoes on the treadmill. This study suggests that the type of high-heeled shoes is related to the VM and VL muscle activation patterns contributing to knee joint pathologies in female patients with PFP.

A Study on a Visual Image of Products-IIConcentrated on a type in purchasing behavior of consumer (제품의 시각이미지에 관한 고찰-II-생활자의 구매행동의 유형을 중심으로-)

  • 지해천
    • Archives of design research
    • /
    • v.2 no.1
    • /
    • pp.107-115
    • /
    • 1989
  • In my previous research (1986), I considered a general characteristics of a visual image of products. There were really many difficulties in designing all kinds of needs in compliance with the all of their requests in order to satisfy consumers. In addition, under the characteristics of goods, the consumers seem to choose an opti$$\mu$ com\ulcornerbinations after considering the combinations of trade-off. Therefore, this study that selected a watch as an object on this study was analyzed a Design Assessment Structure under the trade-off. As a result of this research: First, an effect of a negative superiority appeared under the trade-off condition among ifems when consumers purchased products. Second, these four items were extracted from the eight items which were suggested in this study through an analysis of factors. Third, the three courses were conformed when a consumer purchased a watch. Fourth, in the all kinds of goods, the price which was considered as an important point was not important item ina relation to a purchasing behavior. According to the concomitant effects, we figured out these four items, that is, form, thickness, readability and wearing and its have to be considered a lot when designing a watch.

  • PDF

Do Wearable Devices Change Behavior? A Study of Smart Fitness Trackers

  • Wan, Lili;Zhang, Chao
    • The Journal of Information Systems
    • /
    • v.29 no.1
    • /
    • pp.201-224
    • /
    • 2020
  • Purpose The study focuses on the physical activity behavior change effect of smart wristband, which is the most popular type of fitness tracker nowadays. The purpose of the research is to investigate how people's workout behavior may change after wearing a smart band and examine what kind of role persuasive design plays in behavior change. Design/Methodology/Approach This research employed an experimental study to examine whether the user's workout behaviors changed after using wristband from the "Behavior Wizard" perspective. A representative smart wristband from a major vendor was selected as the objects of experimental study. In the experiment, by comparing users' workout behavior before and after using the wristband, behavior changes of all the experiment participants were classified into one of the 15 behavior change types. Users perceived persuasive design characteristics were measured and group differences were tested among different behavior change groups. Findings This research found that nearly half of the participants changed their workout behavior while half retained their workout status or no exercise status. Half of the participants who did not do exercise in their spare time started walking in the experiment. Results also showed that participants who started working out perceived higher levels of persuasive design devised into the smart band than participants who preserved no exercise status, except for facilitation and reward strategies. Participants who retained workout and those who increased workout frequency perceived no difference in smart band persuasive design.

A Study of Product Analysis for Incontinence Products for the Development of Urinary Incontinence Panties for Senior Male (남성 시니어 요실금팬티 설계를 위한 제품 분석 연구)

  • Koo, Mi-Ran
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.19 no.3
    • /
    • pp.63-74
    • /
    • 2017
  • This study aims to contribute to the development of male incontinence underwear with an anti-aging effect that meets customer requirements by examining the types, sorts, sizes and specifications of male incontinence underwear currently sold on the market. The results of an analysis of a total of eight commercial products are as follows. 1) Among the samples, six types of incontinence underwear were of a pull-on style like regular underwear; two types were of a pad insertion style. With respect to the underwear design, four (50%) types of incontinence underwear were brief style. The rest were drawers (3, 37.5%). Only one was of a trunk (12.5%) style. 2) With respect to size, the percentage of Size 3 was 50%, followed by Size 4 (50%). Most of the size of the underwear uses hip measurement whereas Japanese products (3, 37.5 %) use waist circumference. 3) With respect to the materials of the incontinence underwear, natural fibers such as cotton were mostly used and a polyurethane or polyester was mixed to enhance the wearing sensation and stretchability of the underwear. Finally, for the structure of the pad area, a napping finish was the largest (3, 37.5%), single knit 2(25%), twill weave 2(25%), and rib weave 1.

  • PDF

eWOM Information Search Behavior of Cycle Wear (사이클웨어에 대한 전자 구전 정보 탐색 행동)

  • Choi, Jin Woo;Lee, Yuri
    • Journal of the Korean Society of Costume
    • /
    • v.63 no.8
    • /
    • pp.156-170
    • /
    • 2013
  • The purpose of this research is to scrutinize the cyclist's consumer behavior by analyzing the eWOM information search behavior of cycle-wear according to benefits sought and involvement. The research was conducted through an online survey and the respondents were 291 men who wore cycle-wear and searched information via online. The results of this research are as following. First, the benefits sought from wearing cycle apparel are composed of five sub-factors such as, ideal body figure, brand ostentation, comfort ease, personality, and economic feasibility. In addition, the cycle-wear involvement consisted of two sub-factors: cycling involvement and fashion involvement. Second, the eWOM information search behavior of cyclists was different depending on the benefits sought by the cyclists. When the cyclists pursued ideal body figure they searched more information of design and color, while cyclists put more weight on the information of design, color, and brand when they sought brand ostentation. Moreover, the valence and the type of the information were dissimilar depending on the benefits sought. Third, the sub-factors of eWOM information search behavior affected the eWOM effect distinctively. The price information was the only factor that influenced the eWOM effect among the contents of the information. The valence of the information influenced the eWOM effect, and the effect of positive information was stronger than negative information. Additionally, the subjective information also affected the eWOM effect. Lastly, the effect of the benefits sought influencing the eWOM information search behavior varied by the difference of the cycle-wear involvement. For example, when they are both high in the involvement there were various benefits sought affecting the eWOM information search behavior. However, when only the cycling involvement was high, and they pursued personality, the price information was not important to them.

Influences of Mobile Phone Electromagnetic Wave on Human Body According to Holding Method by the Hand and Wearing Accessories (손과 액세서리에 의한 휴대폰 전자파의 인체 노출 특성)

  • Choi Myung-Sun;Jang Young-Ho;Gimm Youn-Myoung;Park Han-Kyu
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.6 s.97
    • /
    • pp.652-660
    • /
    • 2005
  • In this paper, we compared the spatial peak SAR values measured with and without holding the hand-held phones to check the present recommended spatial peak SAR. To better understand the analysis of the SAR effect values, SAR is measured with hand phantoms, made and recommended for the use of Bar-type and Folder-type hand-held phones. The measured results have shown that use of the hand considerably reduces the spatial peak SAR value in a head phantom. We compared the spatial peak SAR values measured with and without accessories. To better understand the analysis of the effects of SAR values with accessories, SAR is measured with accessories composed of three kinds of earrings and glasses. The measured results proved in study that the spatial peak SAR value in a head phantom is not affected by the earrings but by the glasses. The glasses considerably increases the spatial peak SAR value in a head phantom while using Bar-type phones, although the effects are modest with Folder-type phones.

Effects of Hallux Valgus Orthoses on Ground Reaction Force Using 3D Motion Analysis in Individuals With Hallux Valgus Deformity

  • Kim, Yong-wook
    • Physical Therapy Korea
    • /
    • v.27 no.4
    • /
    • pp.227-232
    • /
    • 2020
  • Background: Hallux valgus (HV) is a foot deformity developed by mediolateral deviation of the first metatarsophalangeal joint. Although various foot-toe orthoses were used to correct the HV angle, verification of the effects of kinetics variables such as ground reaction force (GRF) through three-dimensional (3D) gait analysis according to the various type of orthoses for HV is insufficient. Objects: This study aimed to investigate the effect of soft and hard types of foot and toe orthoses to correct HV deformity on the GRF in individuals with HV using 3D motion analysis system during walking. Methods: Twenty-six subjects participated in the experiment. Participants had HV angle of more than 15° in both feet. Two force platforms were used to obtain 3D GRF data for both feet and a 3D motion capture system with six infrared cameras was used to measure exact stance phase point such as heel strike or toe off period. Total walk trials of each participant were 8 to 10, the walkway length was 6 m. Two-way repeated measures ANOVA was used to determine the effects of each orthosis condition on the various GRF values. Results: The late anteroposterior maximal force and a first vertical peak force of the GRF showed that the hard type orthosis condition significantly increased GRF compared to the other orthosis conditions (p < 0.05). Conclusion: There were significant effects in GRF values when wearing the hard type foot orthosis. However, the hard type foot orthosis was uncomfortable to wear during walking. Therefore, it is necessary to develop a new foot-toe orthosis that can compensate for these disadvantages.