• 제목/요약/키워드: wearable electronics

검색결과 226건 처리시간 0.028초

Reconfigurable Beam-Steering Antenna Using Dipole and Loop Combined Structure for Wearable Applications

  • Ha, Sang-Jun;Jung, Young-Bae;Kim, Yong-Jin;Jung, Chang-Won
    • ETRI Journal
    • /
    • 제34권1호
    • /
    • pp.1-8
    • /
    • 2012
  • This paper proposes a reconfigurable beam-steering antenna using a bended dipole and a loop. The radiation patterns of the two antennas are cancelled or compensated, and headed towards a specific direction when the dipole and loop antenna are combined at a reasonable ratio. The proposed antenna can steer the beam directions by controlling the operation of two artificial switches. The proposed antenna was manufactured on a PCB (FR-4) and a flexible PCB (polyimide). In the case of the antenna that was fabricated on a PCB, the maximum beam directions were $+50^{\circ}$, $0^{\circ}$, and $-50^{\circ}$ in the azimuth direction using the two artificial switches, and the antenna gain was 1.96 dBi to 2.48 dBi in the operation bandwidth of 2.47 GHz to 2.53 GHz. Also, the antenna was fabricated on a flexible PCB and measured under various bending conditions for wearable applications.

A Wrist Watch-type Cardiovascular Monitoring System using Concurrent ECG and APW Measurement

  • Lee, Kwonjoon;Song, Kiseok;Roh, Taehwan;Yoo, Hoi-jun
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제16권5호
    • /
    • pp.702-712
    • /
    • 2016
  • A wrist watch type wearable cardiovascular monitoring device is proposed for continuous and convenient monitoring of the patient's cardiovascular system. For comprehensive monitoring of the patient's cardiovascular system, the concurrent electrocardiogram (ECG) and arterial pulse wave (APW) sensor front-end are fabricated in $0.18{\mu}m$ CMOS technology. The ECG sensor frontend achieves 84.6-dB CMRR and $2.3-{\mu}Vrms$-input referred noise with $30-{\mu}W$ power consumption. The APW sensor front-end achieves $3.2-V/{\Omega}$ sensitivity with accurate bio-impedance measurement lesser than 1% error, consuming only $984-{\mu}W$. The ECG and APW sensor front-end is combined with power management unit, micro controller unit (MCU), display and Bluetooth transceiver so that concurrently measured ECG and APW can be transmitted into smartphone, showing patient's cardiovascular state in real time. In order to verify operation of the cardiovascular monitoring system, cardiovascular indicator is extracted from the healthy volunteer. As a result, 5.74 m/second-pulse wave velocity (PWV), 79.1 beats/minute-heart rate (HR) and positive slope of b-d peak-accelerated arterial pulse wave (AAPW) are achieved, showing the volunteer's healthy cardiovascular state.

종이접기 방식을 사용한 방사패턴 가변형 종이 안테나 설계 (Design of a reconfigurable paper antenna using the origami method)

  • 박동국
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제40권7호
    • /
    • pp.642-646
    • /
    • 2016
  • 본 논문에서는 종이에 전도성 테이프를 이용하여 만든 웨어러블 안테나를 소개한다. 제안하는 안테나는 A4 복사 용지에 반파장 도체 다이폴 스트립과 기생 도체 스트립으로 구성이 되며, SMA 커넥터를 통해 다이폴의 중앙에 급전되는 구조이다. 제안하는 안테나의 모양은 종이 접기에 따라 모양이 달라지며, 따라서 종이를 접었을 때와 펼쳤을 때 안테나의 방사패턴이 가변된다. 이것은 안테나 방사패턴의 영점(null)에 의해 신호의 수신율이 낮아지는 문제점을 해결할 수 있다. 제안하는 안테나의 반사계수와 방사패턴을 900 MHz에서 시뮬레이션과 실험을 통해 제시하였고, 제안하는 종이 안테나가 900 MHz에서 종이접기 방식에 따라 재구성(reconfigurable) 특성이 있음을 보였다.

A Study on a Healthcare System Using Smart Clothes

  • Lim, Chae Young;Kim, Kyungho
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권1호
    • /
    • pp.372-377
    • /
    • 2014
  • Being able to monitor the heart will allow the diagnosis of heart diseases for patients during daily activities, and the detection of burden on the heart during strenuous exercise. Furthermore, with the help of U-health technology, immediate medical action can be taken, in the case of abnormal symptoms of the heart in daily life. Therefore, it appears to be necessary to develop the corresponding technology to monitor the condition of the heart daily. In this study, a novel wearable smart system was proposed, to monitor the activity of the heart in daily life, and to further evaluate the rhythm of arrhythmia. The wearable system includes three modified bipolar conductive fiber electrodes in the chest part, which can resolve the reduction problem of the magnitude of the signal, by magnifying the signal and removing the noise, to obtain high affinity and validity for medical-type usage (<0.903%). The biological signal acquisition and data lines, and the signal processing engine and communication consist of a conductive ink, and the pic18 and ANT protocol nRF24AP2, respectively. The proposed algorithm was able to detect a strong ECG, signal and r-point passing over the noise. The confidence intervals were 96 %, which could satisfy the requirement to detect arrhythmia under the unconstrained conditions.

금-은 코어쉘 나노 와이어 제조 및 투명, 유연 슈퍼캐패시터 전극으로의 활용에 관한 연구 (Au-Ag Core Shell Nanowire Network for Highly Stretchable and Transparent Supercapacitor Applications)

  • 이하범;권진형;조현민;엄현진;고승환
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2016년도 추계학술대회 논문집
    • /
    • pp.183.1-183.1
    • /
    • 2016
  • Due to the latest research trend toward wearable energy devices, transparent and stretchable supercapacitors which can sustain their performance even under physical deformation have steadily attracted huge attention. Despite the Ag NW is the most promising candidate for fabrication of transparent and stretchable electronics, the electrochemical instability interrupts its application to development of the energy device. Here, we introduce a transparent and highly stretchable supercapacitor made by Au-Ag core shell NW network percolation electrode. The Au-Ag core shell NW synthesized by a simple solution process not only shows excellent electrical conductivity but also greatly enhanced chemical and electrochemical stability compare to pristine Ag NW. These outstanding properties of the Au-Ag core shell NW are attributed both to the core Ag NW and the Au protecting sheath layer. The proposed Au-Ag core shell NW based supercapacitor exhibits optical transmittance with outstanding mechanical stability withstanding 60% strain without any decrease of the performance. The supercapacitors connected in series are charged and discharged stable in 30% strain turning on a red LED. These notable results demonstrate the potential of the Au-Ag core shell NW as a strong candidate for development of wearable energy devices.

  • PDF

구현방식이 용이한 텍스타일 터치센서 개발 및 구조적 설계 (Development and Structural Design of Textile Touch Sensor Easily Implemented)

  • 김지선;박진희;김주용
    • 한국의류학회지
    • /
    • 제45권1호
    • /
    • pp.168-179
    • /
    • 2021
  • This study presents and develops a textile type touch sensor structural design that is easy to implement. First, the design of the touch sensor circuit finds the size of the switch with the easiest finger contact and selects a structure with a long circuit with the lowest resistance value. An experiment is performed on a change in an electrostatic capacitance value that accompanies the distance on the electrode and the magnitude of the electrode area of the structure; however, the structure having the distance on the electrode and the large electrode area shows the best resistance change. The laundry assessment was conducted three times at a time and ten times at a time with an average standard deviation less than one ohm, with little change in resistance. Consequently, there were no problems with durability and performance for laundry. Finally, in the bending evaluation, the difference in resistance can be seen between 1-2 ohms and was developed as a smart wearable in the future; in addition, there was no problem as a difference in resistance can be seen between 1 and 2 ohms.

막 기반 마찰전기 나노 발전기: 총설 (Membrane Based Triboelectric Nanogenerator: A Review)

  • 라비아 카갛니;라즈쿠마 파텔
    • 멤브레인
    • /
    • 제33권2호
    • /
    • pp.53-60
    • /
    • 2023
  • 기계적 에너지는 생물학 및 환경 시스템에서 트라이보 전기 나노제너레이터(TENG)로 얻을 수 있다. 웨어러블 전자제품에서 TENG는 진동 센서에 적용된 인간의 움직임에서 생체역학적 에너지를 수확할 수 있다는 점에서 많은 의미를 지닌다. 웨어러블 TENG은 습기에 취약하며, 폴리테트라플루오로에틸렌(PTFE)은 이러한 용도에 사용되는 우수한 소수성 물질이다. 높은 전기 음성 불소 원자의 존재는 매우 낮은 표면 에너지로 이어진다. 동시에 미세다공막 표면에 전자를 효율적으로 포획함으로써 소자의 성능이 증가한다. PTFE에 비해 상대적으로 적은 플루오라이드 원자의 존재로 인해 폴리비닐리덴 플루오라이드(PVDF)에서도 유사한 거동을 보인다.

이중 루프 Digital LDO Regulator 용 ADC 설계 (Design of ADC for Dual-loop Digital LDO Regulator)

  • 박상순;전정희;이재형;최중호
    • 전기전자학회논문지
    • /
    • 제27권3호
    • /
    • pp.333-339
    • /
    • 2023
  • 세계적으로 웨어러블 디바이스의 시장이 확장하고 있으며, 이를 위한 효율적인 PMIC의 수요 또한 늘어나고 있다. 웨어러블 디바이스용 PMIC 특성상 높은 에너지 효율과 작은 면적이 필요하다. 프로세스 기술의 발전으로 저전력 설계가 가능하지만, 기존의 아날로그 LDO 레귤레이터는 전원 전압이 낮아짐에 따라 설계의 어려움이 있다. 본 논문에서는 이중 루프 디지털 LDO용 coarse-fine ADC를 제안한다, ADC의 설계는 55 nm CMOS 공정으로 진행하였고 34.78 dB와 5.39 bits의 SNR과 ENOB를 갖는다.

Gaze Detection by Wearable Eye-Tracking and NIR LED-Based Head-Tracking Device Based on SVR

  • Cho, Chul Woo;Lee, Ji Woo;Shin, Kwang Yong;Lee, Eui Chul;Park, Kang Ryoung;Lee, Heekyung;Cha, Jihun
    • ETRI Journal
    • /
    • 제34권4호
    • /
    • pp.542-552
    • /
    • 2012
  • In this paper, a gaze estimation method is proposed for use with a large-sized display at a distance. Our research has the following four novelties: this is the first study on gaze-tracking for large-sized displays and large Z (viewing) distances; our gaze-tracking accuracy is not affected by head movements since the proposed method tracks the head by using a near infrared camera and an infrared light-emitting diode; the threshold for local binarization of the pupil area is adaptively determined by using a p-tile method based on circular edge detection irrespective of the eyelid or eyelash shadows; and accurate gaze position is calculated by using two support vector regressions without complicated calibrations for the camera, display, and user's eyes, in which the gaze positions and head movements are used as feature values. The root mean square error of gaze detection is calculated as $0.79^{\circ}$ for a 30-inch screen.

Factor Graph-based Multipath-assisted Indoor Passive Localization with Inaccurate Receiver

  • Hao, Ganlin;Wu, Nan;Xiong, Yifeng;Wang, Hua;Kuang, Jingming
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제10권2호
    • /
    • pp.703-722
    • /
    • 2016
  • Passive wireless devices have increasing civilian and military applications, especially in the scenario with wearable devices and Internet of Things. In this paper, we study indoor localization of a target equipped with radio-frequency identification (RFID) device in ultra-wideband (UWB) wireless networks. With known room layout, deterministic multipath components, including the line-of-sight (LOS) signal and the reflected signals via multipath propagation, are employed to locate the target with one transmitter and a single inaccurate receiver. A factor graph corresponding to the joint posterior position distribution of target and receiver is constructed. However, due to the mixed distribution in the factor node of likelihood function, the expressions of messages are intractable by directly applying belief propagation on factor graph. To this end, we approximate the messages by Gaussian distribution via minimizing the Kullback-Leibler divergence (KLD) between them. Accordingly, a parametric message passing algorithm for indoor passive localization is derived, in which only the means and variances of Gaussian distributions have to be updated. Performance of the proposed algorithm and the impact of critical parameters are evaluated by Monte Carlo simulations, which demonstrate the superior performance in localization accuracy and the robustness to the statistics of multipath channels.