• 제목/요약/키워드: weakness zone

검색결과 34건 처리시간 0.02초

와이어 본더에서의 초저 루프 기술 (The Low Height Looping Technology for Multi-chip Package in Wire Bonder)

  • 곽병길;박영민;국성준
    • 반도체디스플레이기술학회지
    • /
    • 제6권1호
    • /
    • pp.17-22
    • /
    • 2007
  • Recent new packages such as MCP(Multi-Chip Package), QDP(Quadratic Die Package) and DDP(Dual Die Package) have stack type configuration. This kind of multi-layer package is thicker than single layer package. So there is need for the low height looping technology in wirebonder to make these packages thinner. There is stiff zone above ball in wirebonder wire which is called HAZ(Heat Affect Zone). When making low height loop (below $80\;{\mu}m$) with traditional forward loop, stiff wire in HAZ(Heat Affected Zone) above ball is bended and weakened. So the traditional forward looping method cannot be applied to low height loop. SSB(stand-off stitch) wire bonding method was applied to many packages which require very low loops. The drawback of SSB method is making frequent errors at making ball, neck damage above ball on lead and the weakness of ball bonding on lead. The alternative looping method is BNL(ball neckless) looping technology which is already applied to some package(DDP, QDP). The advantage of this method is faster in bonding process and making little errors in wire bonding compared with SSB method. This paper presents the result of BNL looping technology applied in assembly house and several issues related to low loop height consistence and BNL zone weakness.

  • PDF

A Case of Hemifacial Spasm Caused by an Artery Passing Through the Facial Nerve

  • Oh, Chang Hyun;Shim, Yu Shik;Park, Hyeonseon;Kim, Eun-Young
    • Journal of Korean Neurosurgical Society
    • /
    • 제57권3호
    • /
    • pp.221-224
    • /
    • 2015
  • Hemifacial spasm (HFS) is a clinical syndrome characterized by unilateral facial nerve dysfunction. The usual cause involves vascular compression of the seventh cranial nerve, but compression by an artery passing through the facial nerve is very unusual. A 20-year-old man presented with left facial spasm that had persisted for 4 years. Compression of the left facial nerve root exit zone by the anterior inferior cerebellar artery (AICA) was revealed on magnetic resonance angiography. During microvascular decompression surgery, penetration of the distal portion of the facial nerve root exit zone by the AICA was observed. At the penetrating site, the artery was found to have compressed the facial nerve and to be immobilized. The penetrated seventh cranial nerve was longitudinally split about 2 mm. The compressing artery was moved away from the penetrating site and the decompression was secured by inserting Teflon at the operative site. Although the facial spasm disappeared in the immediate postoperative period, the patient continued to show moderate facial weakness. At postoperative 12 months, the facial weakness had improved to a mild degree. Prior to performing microvascular decompression of HFS, surgeons should be aware of a possibility for rare complex anatomy, such as compression by an artery passing through the facial nerve, which cannot be observed by modern imaging techniques.

방어산 마애여래입상의 안전진단을 위한 지구물리탐사 (Geophysical Explorations for Safety Analysis of Bangeosan-Maaebul(Stone Relief Bhaisajyaguru triad at Mt. Bangeosan))

  • 오선환;서만철
    • 지구물리
    • /
    • 제4권1호
    • /
    • pp.11-20
    • /
    • 2001
  • 석조문화재에 대한 지구물리학적 진단방법을 제시하기 위해, 경남 함안군 군북면에 있는 방어산 마애불에 대한 굴절법 탄성파탐사와 전기비저항탐사를 수행하였다. 굴절법 탄성파탐사결과 본 마애불 지역의 상부층은 탄성파속도 308~366m/s의 풍화토층, 1906~2090m/s의 연암층과 그 하부의 5061~5650m/s의 극경암층에 해당하는 기반암이 분포하고 있으며, 마애불 주변부의 풍화토층 및 연암층에 대한 지반보강대책이 설계되어야 할 것으로 판단된다. 전기비저항 탐사결과 마애불 우측부에 남북~북북동 방향의 131~226 Ohm-m의 낮은 비저항대가 발견되며, 이 부분은 강우시에 지하수의 유동통로 역할을 하여 대상 부지 중에서 가장 취약한 연약구간이다.

  • PDF

비활성 그리고 활성 단층지역 내부와 주변에서의 응력장에 대한 수치적 분석 (Numerical Analysis of Stress Regimes in and around Inactive and Active Fault Zones)

  • 정우창;송재우
    • 한국방재학회 논문집
    • /
    • 제1권1호
    • /
    • pp.117-125
    • /
    • 2001
  • 비활성 그리고 황성 단층지역의 내부와 주변에서 발생하는 응력장의 변화에 대한 수치적 분석이 수행되었다. 존재하는 비활성 단층지역 근처에서의 응력장은 단층의 방향과 단층화된 암반과 주위의 비단층화된 암반의 탄성적 특성 사이의 대조에 따라 변화한다. 활성 단층지역 주위의 응력장에 대한 분석에서, 만약 단층지역의 항복응력이 초과된다면, 단층지역 내에서의 국부화된 전단응력은 주위의 비단층화된 암반에서의 평균응력 보다 작게 되는 단층 내에서의 평균응력의 감소를 유발시킨다. 따라서 이러한 응력경사는 단층지역내로 유체의 흐름을 기대할 수 있다.

  • PDF

서울일대 암반을 대상으로 한 Geotechnical Information System (GTIS)의 개발 및 활용 (2) (A Development and utilization of Geotechnical Information System(GTIS) of the Rock Mass in Seoul Metropolitan Area(2))

  • 김정엽;박형동
    • 터널과지하공간
    • /
    • 제6권3호
    • /
    • pp.223-233
    • /
    • 1996
  • Geotechnical Information System (GTIS) for efficient management of three dimensional borehole data has been developed. Geotechnical maps in the vicinity of Bulkwangdong, Seoul station, Itaewon, Han river near Yuido, and Jungrangchon were constructed by Kriging method. In Bulkwangdong and Jungrangchon area where boundary between granite and gneiss is present, gneiss has been more weathered than granite, but in Seoul station and Itaewon area where the boundary is also present, granite has been more weathered than gneiss. It has been inferred that when Seoul granite intruded, the strength of gneiss in Bulkwangdong and Jungrangchon area was lowered by the attitude of foliation plane than in Seoul station and Itaewon area, so the gneiss has been easily fractured and weathered in Bulkwangdong and Jungrangchon area. Geotechnical map in the vicinity of Yuido showed that there is an NW-SE trend weakness zone that might be affected by major faults under Han river and it is expected that the fault zone may be present in construction area of Kyoungbu Highspeed Railway that lies below the Han river like the Subway Line No.5.

  • PDF

Effects of deficiency location on CFRP strengthening of steel CHS short columns

  • Shahabi, Razieh;Narmashiri, Kambiz
    • Steel and Composite Structures
    • /
    • 제28권3호
    • /
    • pp.267-278
    • /
    • 2018
  • Structures may need retrofitting as a result of design and calculation errors, lack of proper implementation, post-construction change in use, damages due to accidental loads, corrosion and changes introduced in new editions of construction codes. Retrofitting helps to compensate weakness and increase the service life. Fiber Reinforced Polymer (FRP) is a modern material for retrofitting steel elements. This study aims to investigate the effect of deficiency location on the axial behavior of compressive elements of Circular Hollow Section (CHS) steel short columns. The deficiencies located vertically or horizontally at the middle or bottom of the element. A total of 43 control column and those with deficiencies were investigated in the ABAQUS software. Only 9 of them tested in the laboratory. The results indicated that the deficiencies had a significant effect on the increase in axial deformation, rupture in deficiency zone (local buckling), and decrease in ductility and bearing capacity. The damages of steel columns were responsible for resistance and stiffness drop at deficiency zone. Horizontal deficiency at the middle and vertical deficiency at the bottom of the steel columns were found to be the most critical. Using Carbon Fiber Reinforced Polymer (CFRP) as the most effective material in retrofitting the damaged columns, significantly helped the increase in resistance and rupture control around the deficiency zone.

국내외 연안구역관리 지표체계의 특성 (The Characteristics of Foreign and Domestic Coastal Zone Management Indicator System)

  • 남광우;오지훈
    • 한국산학기술학회논문지
    • /
    • 제13권2호
    • /
    • pp.885-892
    • /
    • 2012
  • 연안구역 관리지표는 연안통합관리의 정책수립 이행과정에 중요한 의사결정수단으로 활용되며, 통합적 관점에서 평가하고 부문별 상호작용을 이해하고 분석할 수 있는 유용한 도구이다. 이에 대부분의 국제사회기구와 선진 연안국들은 현 연안환경과 사회 경제적 상태를 정기적으로 점검하고 연안구역관리정책의 효과성을 파악하기 위하여 연안구역관리 지표체계를 개발하고 있는 추세이다. 따라서 본 연구는 국내외 연안구역관리 지표체계를 크게 자연 환경적측면, 사회 경제적 측면, 네트워크 측면으로 구분해 각 차원별 연안구역관리 지표체계의 장 단점을 파악하고 비교 분석해 연안구역관리 지표체계의 특성을 도출하였다. 이를 통해 이 연구는 지속가능한 연안구역관리의 실현을 위한 관리수단, 다양한 이해관계자들의 과학적 의사결정수단, 연안통합관리의 실효성 평가수단, 연안구역관리 지표체계의 이원화 등을 선진사례의 공통된 특성으로 도출하였다. 마지막으로 본 연구는 국내외 연안구역관리 지표체계에서 나타난 공통의 가치를 바탕으로, 지역차원에서 국내 연안구역관리 지표의 올바른 설정을 위한 시사점을 제시하였다.

Cone beam형 전산화단층촬영장치를 이용한 하악 제1대구치 근심 치근의 danger zone에 관한 연구 (Evaluation of danger zone in mesial root of mandibular first molar by cone beam computed tomography (CBCT))

  • 장유리;최용석;최기운;박상혁
    • Imaging Science in Dentistry
    • /
    • 제37권2호
    • /
    • pp.103-110
    • /
    • 2007
  • Purpose: To examine the danger zone of mesial root of mandibular first molar of patient without extraction using CBCT (cone-beam computed tomography) to avoid the risk of root perforation. Materials and Methods: 20 mandibular first molars without caries and restorations were collected, CT images were obtained by CBCT ($PSR9000N^{TM}$, Asahi Roentgen Co., Japan), reformed and analyzed by V-work 5.0 (CyberMed Inc., Korea), Distance between canal orifice and furcation was measured. In cross sectional images at 3, 4 and 5 mm below the canal orifice, distal wall thickness of mesiobuccal canal (MB-D), distal wall thickness of mesiolingual canal (ML-D), distal wall thickness of central part (C-D), mesial wall thickness of mesiobuccal canal (MB-M) and mesial wall thickness of mesiolingual canal (ML-M) were measured, Results: The mean distance between the canal orifice and the furcation of the roots is 2.40 mm, Distal wall is found to be thinner than mesial wall. Mean dentinal wall thickness of distal wall is about 1 mm, The wall thickness is thinner as the distance from the canal orifice is farther. But significant differences are not noted between 4 mm and 5 mm in MB-D and C-D, MB-D is thinner than ML-D although the differences is not significant. Conclusion: The present study confirmed the anatomical weakness of distal surface of the coronal part of the mesial roots of mandibular first molar by CBCT and provided an anatomical guide line of wall thickness during endodontic treatment.

  • PDF

T-Joint 용접부의 Groove형상별 크리프 특성에 관한 연구 (A Study on the Creep Characteristics according to Groove Shape of T-Welded Joint)

  • 방한서;김종명
    • 한국해양공학회지
    • /
    • 제13권3호통권33호
    • /
    • pp.68-76
    • /
    • 1999
  • The welding residual stresses produced by the welding frequently caused a crack and promote stress corrosion etc. in HAZ(heat affected zone) contained with external load and weakness of material. Therefore, PWHT(post welding heat treatment) is widely used to reduce wekdubg residuss, to relax hardening of heat affected zone and to get rid of impurity. In this study, in order to define the effect on shappes of T-welded joint, during the post welding heat treatment, we have carried out numerical analyses on the several test pieces by using computer program which was based on thermal-elasto-plato-plasto-creep theories for the study. The main results obtained form this study is as follows: 1) The mechanical difference for change the thickness of plate and groove angle did not appear. 2) The distribution modes of welding residual stresses are same on the all test specimens during the post welding heat treatment. 3) In a mecharical point of view, minimum groove groove angle($40^{circ}$) is more suitable than maximum groove angle($60^{circ}$). 4) Therefore, it is appropriate to minimize the size of groove shape in strength and safety.

  • PDF

Moving Mesh Technique을 이용한 2차원 염해 침투 예측 모델의 개발 (Development of Two Dimensional Chloride Ion Penetration Model Using Moving Mesh Technique)

  • 최원;김한중
    • 한국농공학회논문집
    • /
    • 제57권6호
    • /
    • pp.1-7
    • /
    • 2015
  • Most of chloride diffusion models based on finite difference method (FDM) could not express the diffusion in horizontal direction at each elevation. To overcome these weakness, two dimensional chloride ion penetration model based on finite element method (FEM) to be able to combine various multi-physics simultaneously was suggested by introducing moving mesh technique. To avoid the generation of mesh being able to be distorted depending on the relative movement of water level to static concrete, a rectangular type of mesh was intentionally adopted and the total number of meshes was empirically selected. The simulated results showed that the contents of surface chloride decreased following to the increase of elevation in the top part of low sea level, whereas there were no changes in the bottom part of low level. In the DuraCrete model, the diffusion coefficient of splashed zone is generally smaller than submerged zone, whereas the trend of Life365 model is reverse. Therefore, it could be understood that the developed model using moving mesh technique effectively reflects $DuraCrete^{TM}$ model rather than $Life365^{TM}$ model. In the future, the model will be easily expanded to be combined with various multi-physics models considering water evaporation, heat of hydration, irradiation effect of sun and so on because it is based on FEM.