• Title/Summary/Keyword: wban

Search Result 182, Processing Time 0.022 seconds

A Utility-Based and QoS-Aware Power Control Scheme for Wireless Body Area Networks

  • Li, Yanjun;Pan, Jian;Tian, Xianzhong
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.10 no.9
    • /
    • pp.4188-4206
    • /
    • 2016
  • Power control is widely used to reduce co-channel interference in wireless networks and guarantee the signal-to-interference plus noise ratio (SINR) of ongoing connections. This technique is also effective for wireless body area networks (WBANs). Although achieving satisfactory SINR is important for WBAN users, they may not be willing to achieve it at arbitrarily high power levels since power is a scarce resource in WBANs. Besides, for WBANs with different purposes, the QoS requirements and concern about the power consumption may be different. This motivates us to formulate the power control problem using the concepts from microeconomics and game theory. In this paper, the QoS objective is viewed as a utility function, which represents the degree of user satisfaction, while the power consumption is viewed as a cost function. The power control problem consequently becomes a non-cooperative multiplayer game, in which each player tries to maximize its net utility, i.e., the utility minus the cost. Within this framework, we investigate the Nash equilibrium existence and uniqueness in the game and derive the best response solution to reach the Nash equilibrium. To obtain the optimal transmission power in a distributed way, we further propose a utility-based and QoS-aware power control algorithm (UQoS-PCA). Tunable cost coefficient in UQoS-PCA enables this scheme to be flexible to satisfy diverse service requirements. Simulation results show the convergence and effectiveness of the proposed scheme as well as improvements over existing algorithm.

Bromide Concentration in Human Biological Samples Intoxicated by Methylbromide (Methylbromide에 중독된 인체시료 중 브롬이온의 함량)

  • You, Jae-Hoon;Lee, Sang-Ki;Jin, Kwang-Ho;In, Sang-Wban;Yoo, Young-Chan;Park, Sung-Woo
    • Analytical Science and Technology
    • /
    • v.11 no.2
    • /
    • pp.88-91
    • /
    • 1998
  • Bromide($Br^-$) was separated and quantified with $2.8mM-NaHCO_3/2.2mM-Na_2CO_3$ by Ion Chromatography. Bromide was eluted at 8.9 min. and the detectetion limit was 2.5 ng. We compared with bromide concentration in normal or methylbromide intoxicated bloods and tissues. Bromide concentrations were 2.0~5.8 ppm in normal bloods and 1.0~5.3 ppm in normal tissues. In fatal cases of methylbromide intoxication, blood bromide concentrations (4 cases) of 74.2~139 ppm and tissue bromide concentration (1 case) of 76 (heart)~201 (lung) ppm were detected. In fatal cases, blood bromide concentrations. were 12~22 times higher than those of normal bloods.

  • PDF

Smart Device based ECG Sensing IoT Applications (스마트 디바이스 기반 ECG 감지 IoT 응용 서비스에 관한 연구)

  • Mariappan, Vinayagam;Lee, Seungyoun;Lee, Junghoon;Lee, Juyoung;Cha, Jaesang
    • Journal of Satellite, Information and Communications
    • /
    • v.11 no.3
    • /
    • pp.18-23
    • /
    • 2016
  • Internet of things (IoT) is revolutionizing in the patient-Centered medical monitoring and management by authorizing the Smartphone application and data analysis with medical centers. The network connectivity is basic requirement to collect the observed human beings' health information from Smartphone to monitor the health from IoT medical devices in personal healthcare. The IoT environment built in Smartphone is very effective and does not demand infrastructure. This paper presents the smart phone deployed personal IoT architecture for Non-Invasive ECG Capturing. The adaptable IoT medical device cum Gateway is used for personal healthcare with big data storage on cloud configuration. In this approach, the Smartphone camera based imaging technique used to extract the personal ECG waveform and forward it to the cloud based big data storage connectivity using IoT architecture. Elaborated algorithm allows for efficient ECG registration directly from face image captured from Smartphone or Tablet camera. The profound technique may have an exceptional value in monitoring personal healthcare after adequate enhancements are introduced.

On the QoS Support in Medium Access Control for Medical Sensor Networks (의료용 센서 네트워크에서 QoS 지원의 매체접속제어)

  • Ashrafuzzaman, Kazi;Kwak, Kyung-Sup
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.9 no.6
    • /
    • pp.151-158
    • /
    • 2010
  • In line with the requirement of appropriate protocol support for such mission-critical wireless sensor network (WSN) applications as patient monitoring, we investigate the framework for designing medium access control (MAC) schemes. The data traffic in medical systems comes with inherent traffic heterogeneity as well as strict requirement of reliability according to the varied extents of devise-wise criticality in separate cases. This implies that the quality-of-Service (QoS) issues are very distinctly delicate requiring specialized consideration. Besides, there are features in such systems that can be exploited during the design of a MAC scheme. In a monitoring or routine surveillance application, there are degrees of regularity or predictability in traffic as coordinated from a node of central control. The coordinator thus takes on the role of marshaling the resources in a neighborhood of nodes deployed mostly for upstream traffic; in a collision-free scheme, it schedules the time slots for each superframe based on the QoS specifications. In this preliminary study, we identify the key artifacts of such a MAC scheme. We also present basic performance issues like the impact of superframe length on delay incurred, energy efficiency achieved in the network operation as obtained in a typical simulation setup based on this framework.

Energy-Aware Configuration Management with Guaranteed Lifetime of Network in Multi-hop WBAN (무선 신체 망에서 망의 생존시간을 보장하는 에너지 인지 망 구성 관리 기법)

  • Seo, Su-Ho;Nah, Jae-Wook;Park, Jong-Tae
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.34 no.10B
    • /
    • pp.981-987
    • /
    • 2009
  • Recently, the study on wireless body area network for providing ubiquitous healthcare services has been actively done, including the standardization of the IEEE and others. Wireless body area network is usually configured in tree format using multi-hop communication mode due to the power limitation and the characteristics of human body. In this case, differently from existing sensor network, the wireless body area network tends to be disconnected due to the frequent movement of human body. The number of connections which can be supported at each node has some limitations due to the constraint imposed on power consumption. In this paper, we have proposed a heuristic algorithm for optimal selection of parent node with guaranteed QoS for a disconnected node, which considers the priority on packet transmission. Simulation has been performed to evaluate the performance of the proposed algorithm.

Design of a Modified Alford Loop Antenna for On-Body Devices (인체 부착형 기기를 고려한 변형된 Alford 루프 안테나 설계)

  • Park, Joongki;Lee, Juneseok;Choi, Jaehoon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.1
    • /
    • pp.25-31
    • /
    • 2014
  • In this paper, a modified Alford loop antenna for on-body communication system is proposed. The proposed antenna operating in the ISM band is designed with consideration of human body effect. One of advantages of the Alford loop antenna structure is low-profile, however the Alford loop antenna is not suitable for on-body devices since it does not have a ground plane for other electronic part of on-body system and requires balanced feeding structure. To be embedded on on-body devices, the proposed antenna is design with the unbalanced feed structure and ground. The performance of the proposed antenna is simulated and measured when it is placed on the human body phantom to consider the effect of the human body. The proposed antenna a 10 dB return loss bandwidth over the ISM band and monopole-like radiation pattern with low-profile. The antenna has the surface of appropriate for on-body communication environment.

Design of UWB MIMO Antenna for On-Body Application (인체 부착형 UWB MIMO 안테나 설계)

  • Joo, Eunman;Kwon, Kyeol;Jeon, Jaesung;Kim, Sunwoo;Choi, Jaehoon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.2
    • /
    • pp.137-148
    • /
    • 2014
  • In this paper, design of a UWB MIMO antenna for an on-body application is proposed and antenna performance with body effect and the impact on the human body are investigated. The proposed MIMO antenna is composed of UWB antenna above ground plane and an additional plunger shaped isolator located between the two monopole antennas to enhance the isolation characteristic. The simulation and measurement are performed to analyze the effect of the human body on antenna performance when the human body is located in the near field of the antenna. According to the measurement results, the measured SAR values for antennas 1 and 2 are 0.132 W/kg and 0.08 W/kg, respectively when 0.5 mW input power is delivered. These values satisfy the FCC guideline which ragulates that the 1-g average SAR should be lower than 1.6 W/kg.

Design of a Planar Antenna with Monopole-like Radiation Pattern for On-Body Communications (수직 모노폴 방사패턴을 갖는 인체표면 통신용 평면형 안테나 설계)

  • Kwon, Jaekwang;Woo, Seungmin;Tak, Jinpil;Choi, Jaehoon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.26 no.4
    • /
    • pp.365-373
    • /
    • 2015
  • In this paper, a planar antenna with monopole-like radiation pattern for on-body communications is proposed. The proposed antenna consists of three split-rings(SR) to generate a monopole-like radiation characteristic. To account for the on-body application, the proposed antenna is designed to have a low-profile. The antenna has an overall dimensions of $0.29{\lambda}_0{\times}0.29{\lambda}_0{\times}0.008{\lambda}_0$ at 5.8 GHz industrial, scientific, and medical(ISM) band(5.725~5.875 GHz). To verify the body effect, a two-thirds muscle equivalent semi solid phantom is fabricated and used to measure the antenna performance. The 10-dB return loss bandwidth is 280 MHz(5.68~5.96 GHz) and the measured peak gain is 1.91 dBi.

PSPM System for Low Power Communication and Performance Analysis in Multipath Channel (저전력 통신을 위한 PSPM(Phase Shift Position Modulation) 방식과 다중 경로 채널에서 성능 분석)

  • Choi, Jae-Hoon;Ryu, Heung-Gyoon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.12
    • /
    • pp.1394-1400
    • /
    • 2010
  • In this paper, we analyze performance of PSPM(Phase Shift Position Modulation) modulation scheme in multi-path channel. A PSPM modulation method transmits the information data by both PSK symbol data and symbol position data, so that we can significantly improve the power efficiency. The bandwidth efficiency of PSPM is quarter than PSK but improve BER performance, because increasing symbol hamming distance. In this results, a PSPM scheme is bandwidth efficiency better than FSK and power efficiency better than PSK. This characteristic can be useful in WBAN and wireless sensor networks also PSPM modulation method can be expected high throughput than existing FSK. In this paper, we compare PSPM, PSSK and PSK regard to BER performance and throughput in multi-path channel.

Adaptive Situation of the wireless communication technology for the Medical Science Environment (무선정보통신기술의 의료과학 환경 적용현황 분석)

  • Hwang, Jin-Ok;Lee, Do-Yeon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.9
    • /
    • pp.2100-2106
    • /
    • 2015
  • Recently, we are increasing an interest of the health care from the developing elderly society. The need for the safety standardization is the High-tech industry that the technology of Medical science based on advanced nations with the wireless communication technology. It is urgent matter the chronic disease that is growing the total costs is everyday increased. We consider the standardization of the monitoring the medical examination based on the medical science environment with wireless communication technology. In addition, we make the environment of the powerful nation based on medical / patient care technology for the supporting of the high quality service. In this paper, we focus on description of the relationship that convergence of the medical / patient care science is need the component based on wireless communication technology.