• Title/Summary/Keyword: wave duration

Search Result 269, Processing Time 0.028 seconds

Effects of 6 Week Kinesiotaping and Extracorporeal Shock Wave Therapy on the Joint Range of Motion in Patients with Frozen Shoulder

  • Choi, Jung Hyun;Kim, Soon Hee;An, Ho Jung;Koo, Ja Pung;Kim, Nyeon Jun
    • Journal of International Academy of Physical Therapy Research
    • /
    • v.8 no.1
    • /
    • pp.1095-1099
    • /
    • 2017
  • This study used both kinesiotaping and extracorporeal shock wave therapy on patients diagnosed with frozen shoulder - a common musculoskeletal disorder in adults - in order to observe the effects on the joint range of motion. 21 adult(male 12, female 9) were selected and distributed into randomized groups. One group received kinesiotaping (n=10) and the other group received kinesiotaping together with extracorporeal shockwave therapy (n=11). After a 6 week duration of receiving kinesiotaping and extracorporeal shockwave therapy, changes in the joint range of motion in the patients were observed. Post-treatment of frozen shoulder, the changes in abduction within the shoulder joint were as follows: in both groups there was a noticeable increase in the joint range of motion (p<.05). Post-treatment of frozen shoulder, the changes in external rotation within the shoulder joint were as follows: both groups showed a significant increase in the joint range of motion (p<.05). The result of suggest that, it can be inferred that both the extracorporeal shockwave therapy and kinesiotaping are effective in increasing the joint range of motion in patients with frozen shoulder.

Electrofusion of Tobacco and Pea Protoplasts (전기장하에서의 담배 및 완두 원형질체 융합)

  • 서정우
    • Journal of Plant Biology
    • /
    • v.29 no.1
    • /
    • pp.1-10
    • /
    • 1986
  • Intra- and inter-specific protoplast fusion of tobacco (Nicotiana tabacum cv. Virginia 115) and pea (Pisum sativum cv. Sparkle) were carried out in highly inhomogeneous alternating electric fields. Under the electric field of alternating current (AC, sine wave), 600 V/cm and 800 kHz for tobacco protoplast, and 600 V/cm and 700 kHz for pea protoplasts, the protoplasts were aggregated in pearl chains. Intra-specific protoplast fusions were most effectively induced within the aggregates of tobacco and pea, respectively, by the additional application of a single high field pulse of direct current (DC, square wave) at 1 kV/cm for 50 $mutextrm{s}$. Inter-specific fusions between protoplasts of the two plants were most effectively induced in the electric field of 600 V/cm and 700 kHz, and square wave pulse at 1 kV/cm for 50 $mutextrm{s}$. The duration of the pulse over the electrical breakdown voltages was simulated from 1 to 100 $mutextrm{s}$ in both tobacco and pea protoplast. The yield of the electrofusion products was significantly high (above 60%), compared with that (20%) of the standard fusion method by polyethylene glycol (PEG) 4,000, and the viability of electrofused protoplasts was above 70%, but that of PEG-fused protoplasts 8~16%, when determined by Evan's blue staining method.

  • PDF

High-power Quasi-continuous Wave Operation of Incoherently Combined Yb-doped Fiber Lasers

  • Jeon, Minjee;Jung, Yeji;Park, Jongseon;Jeong, Hoon;Kim, Ji Won;Seo, Hongseok
    • Current Optics and Photonics
    • /
    • v.1 no.5
    • /
    • pp.525-528
    • /
    • 2017
  • High-energy, high-power, quasi-continuous wave (QCW) operation of double-clad Yb fiber lasers incorporating an incoherent signal combiner is reported. We constructed four efficient, high-power Yb fiber lasers, each of which produced rectangular pulses at 1080 nm with a pulse energy greater than 15 J, and a pulse duration of 10 ms at a repetition rate of 10 Hz, corresponding to an average power of over 150 W and a peak power of over 1.5 kW for ~200 W of incident pump power at 915 nm. These laser outputs were combined by a homemade incoherent fiber signal combiner with low loss, yielding a maximum peak power of ~6.0 kW in a beam with $M^2{\approx}12.5$. The detailed laser characteristics and prospects for further power scaling in QCW operation are discussed.

Thrust Measurement in a Impulse Facility (충격파 시험장치를 이용한 추력 측정)

  • Jin, Sangwook;Hwang, Kiyoung;Park, Dongchang;Min, Seongki
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.310-319
    • /
    • 2017
  • This paper introduces the method how to measure the thrust in impulse facility. In a Facility having such a short duration time of steady flow, there's no time to reach a steady state of the forces acting on model so that the test model vibrates until the end of the flow. The forces exerted on an engine exist with vibration so that the usual force balance can not be used. SWFB(Stress Wave Force Balance) technique is utilized in a shock tunnel to get the thrust. As an example, a model force balance has been calculated its strain against impulse force by using FEM(Finite Element Method). A transfer function between the impulse force and strain has been obtained by the way of de-convolution.

  • PDF

Artificial Generation of Seismic Wave Reflecting Information (위상특성을 반영한 인공지진파 작성)

  • 연관희
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2000.10a
    • /
    • pp.91-97
    • /
    • 2000
  • Once a response spectrum is estimated for the site, if there is a need of generating realistic earthquakes time histories considering seismic sources and path effects, one alternative is to use statistical phase characteristics based on real earthquake records other than assuming arbitrary duration and envelope curves. In this study, statistics of group delay times derived from Japanese strong earthquake data were used for phase generation to fully capture the stochastic property of earthquakes. The result shows that simulated earthquake time histories can be generated according to earthquake magnitude and distances with target response spectrum.

  • PDF

Clinical and Electromyographic Study of the Effects of Ultrasonic Wave and Microwave Diathermy Treatment on the Craniomandibular Disorder Patients (두개하악장애 환자에 대한 초음파와 극초단파 심부투열치료 효과의 임상 및 근전도학적 연구)

  • Hye-Jin Lee;Myung-Yun Ko
    • Journal of Oral Medicine and Pain
    • /
    • v.16 no.1
    • /
    • pp.103-111
    • /
    • 1991
  • This study was performed to observe the effect of micro-wave diathermy and ultrasonic-wave diathermy on the craniomandibular disorder patients. 19 patients were classified into 12 acute and 7 chronic groups according to the duration of 6 months. They were treated with micro-wave diathermy and ultrasonic-wave diathermy for 2 weeks and pain, maximum comfortable opening, active range of motion were checked before and after therapy. Electromyographic activities of temporal and masseter muscles were also measured at physiologic rest position, clenching and mastication before and after therapy. The obtained results were as follows : 1. After treatment, pain were reduced and active range of motion and maximum comfortable opening were increased. 2. Temporoal and masseter muscle activities of post-treatment in rest position, clenching and mastication were lower than those of pre-treatment. 3. In rest position, temporal and masseter muscle activities of pre-treatment on affected sides were higher than those on unaffected sides, but there were no differences in muscle activities between affected ad unaffected sides on clenching and mastication in pre and post-treatment respectively. 4. There were no significant differences in active range of motion, pain and maximum comfortable opening between acute and chronic groups in pre and post-treatment but there were significant differences between pre-treatment and post-treatment in acute and chronic groups respectively. 5. Muscle activities of masseter and temporal muscles in acute and chronic patients were reduced in rest position after treatment.

  • PDF

P wave dispersion on 12-lead electrocardiography in adolescents with neurocardiogenic syncope

  • Lee, Dong-Hyuk;Lee, Kyung-Min;Yoon, Jung-Min;Lim, Jae-Woo;Kho, Kyung-Ok;Kil, Hong-Ryang;Cheon, Eun-Jung
    • Clinical and Experimental Pediatrics
    • /
    • v.59 no.11
    • /
    • pp.451-455
    • /
    • 2016
  • Purpose: Neurocardiogenic syncope (NCS) is the most frequent cause of fainting during adolescence. Inappropriate cardiovascular autonomic control may be responsible for this clinical event. The head-up tilt test has been considered a diagnostic standard, but it is cumbersome and has a high false-positive rate. We performed a study to evaluate whether P-wave dispersion (PWD) could be a useful electrocardiographic parameter of cardiac autonomic dysfunction in children with NCS. Methods: Fifty-four patients with NCS (28 boys and 26 girls; mean age, $12.3{\pm}1.4$ years) and 55 age- and sex-matched healthy controls were enrolled. PWD was obtained as the difference between maximum and minimum durations of the P wave on standard 12-lead electrocardiography in all patients and controls Results: The value of PWD was significantly higher in the syncope group than in the control group ($69.7{\pm}19.6$ msec vs. $45.5{\pm}17.1$ msec, respectively; P<0.001). The minimum duration of P wave was shorter in the syncope group than in the control group ($43.8{\pm}16.8$ msec vs. $53.5{\pm}10.7$ msec, respectively; P<0.001). Left atrial volume was not different between the groups on transthoracic echocardiography. Conclusion: PWD on echocardiography could be used as a clinical parameter in patients with NCS.

The Effects of Blood Circulation and Skin Temperature by Ultrasound (초음파가 혈류량 및 피부온도에 미치는 영향)

  • Oh Min-Young;Jang Chel;Kim Hyun-jung
    • The Journal of Korean Physical Therapy
    • /
    • v.16 no.4
    • /
    • pp.179-201
    • /
    • 2004
  • The purpose of this study was to determine the effect of application methods in ultrasound on skin temperature and muscle blood flow. Thirty healthy volunteers without known vascular problems participated and randomly divided into three groups such as continuous wave group (CWG) which received a ultrasound treatment of continuous-wave, intermittent wave group (IWG) which received a ultrasound treatment of intermittent-wave at a dosage of $1.5\;W/cm^2$ for a duration of 5 minutes, and placebo group (PG) which received a ultrasound treatment of no-wave and no-dosage ultrasound to the anterior forearm. Blood flow and skin temperature was measured using MP 150 before and after ultrasound administration. The results were as follows : 1. Administration of ultrasound in all groups had increased effect on skeletal muscle blood flow immediately after treatment and for up to 10 minutes posttreatment. 2. CWG and IWG showed increased skin temperature immediately after a ultrasound administration and maintained to 10 minutes posttreatment. PG showed increased skin temperature immediately after a ultrasound administration but returned to initial state to 10 minutes posttreatment. 3. The great change on skeletal muscle blood flow among three groups showed in CWG ($6.27{\pm}1.72$) and then displayed in PG ($5.12{\pm}1.66$) and IWG ($4.61{\pm}2.19$) in order. 4. The vast change on skin temperature among three groups showed in CWG and then IWG and PG in order.

  • PDF

EXPERIMENTAL STUDY OF LARYNGEAL BRAIN STEM EVOKED RESPONSE IN CAT (고양이에서 상후두신경자극에 의한 후두뇌간유발반응에 대한 실험적 연구)

  • 김광문;김기령;윤주헌;김창규;박용재
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1991.06a
    • /
    • pp.14-14
    • /
    • 1991
  • 후두의 생리적 기능은 하기도를 보호하는 방어기능과 호흡기능 그리고 발성기능으로 대별할 수 있는데 이 가운데 계통발생적으로 가장 원시적이지만 중요한 기능은 하기도 방어기능으로 이는 다른 기능과 달리 전적으로 불수의적이고 반사적으로 이루어진다. 이 기능은 후두내 점막에 존재하는 촉각 수용체(tactile receptor)가 자극되면서 후두근육이 수축 반사를 일으켜 성문이 닫히는 성문폐쇄반사(glottic closure reflex)로서 다접합뇌간반사(polysynaptic brain stem response)이다. 현재까지 후두의 신경장애에서 그 부위나 정도 또는 신경재생 상태 등을 검사하는 방법으로 근전도검사가 주로 쓰여져 왔으나 그것이 주는 정보가 극히 제한되어 있다. 그러나 최근 청각뇌간유발반응과 같이 후두뇌간유발반응 이라 명명된 wave가 존재한다는 사실이 밝혀져 이에 대한 연구가 이루어지고 있어 이것이 임상에 쓰여질 수 있다면 현재 성문폐쇄반사의 소실이나 이상이 원인으로 사료되는 idiopathic laryngospasm, gastroesophageal reflux, spastic dysphonia, stuttering, sudden infant death syndrome과 같은 질환의 진단과 치료에 커다란 진전이 있을 것이다. 이에 저자들은 고양이 6마리를 이용하여 상후두신경을 전기적으로 자극하여 유발되는 반응을 far field recording을 이용 평균 가산법으로 그 wave를 측정하여 다음과 같은 결과를 얻었다. 1. 상후두신경자극(2㎃, stimuli frequency 3/s, Band filter 320-1000, 0.2 ㎳ duration)에 의한 반회신경에의 유발 반응을 기록하였고 그 잠복시간은 평균 8.2 ㎳ 였다. 2. 상후두신경을 자극하여 후두뇌간유발반응을 기록하였고 후두뇌간유발반응은 4개의 양 wave와 4개의 음 wave로 구성되었다. 3. 각 wave의 평균 잠복시간은 P1은 0.8㎳, P2는 2.3㎳, P3는 3.6㎳, P4는 4.3㎳였고 N1은 1.5㎳, N2 은 2.7㎳, N3는 3.9㎳, N4는 5.5㎳ 였다.

  • PDF

Suggestions for Setting on Period of Epidemic Waves in COVID-19 Epidemic of South Korea (한국 코로나19 유행기에 대한 제안)

  • Lee, Moo-Sik
    • Journal of agricultural medicine and community health
    • /
    • v.47 no.2
    • /
    • pp.61-66
    • /
    • 2022
  • Objectives: In the epidemiology of communicable diseases, the term epidemic period, also referred to as "wave" is often used in the general and academic milieu. A wave refers to a natural pattern of increase in the number of sick individuals, a defined peak, and then a decline in the number of cases. It implies a pattern of peaks and valleys after a particular peak is taken. The idea of epidemic waves is a useful tool for predicting the course as well as helping to accurately describe an epidemic. However, in many domestic and foreign news as well as in various research results in Korea, most of the reports either had no standard, were inaccurate, had a questionable classification of the period of the epidemic, or the basis for classification of a given wave was not presented. Methods: The author reviewed and organized related literature with epidemic wave. The author made several suggestions of an epidemic wave as follows. Results: To start with, it should be based on the number of incident cases in consideration of the size of the outbreak, then the period from the bottom to the peak and then reaching the next bottom; also, the period over a certain scale based on the number of incident cases; and the period according to the change in the major infection type (mutation-dominant species). In addition, according to the period of change in the vaccination rate (formation of herd immunity), as well as the content and duration of the intervention, that is, classification according to the applied quarantine stage. Furthermore, the classification of epidemic periods by the time-dependent reproduction number or time-varying reproduction number (Rt), and lastly the application of mathematical methodology. Conclusions: Therefore, classifying the epidemic period into generally known and accepted time frames is considered to be a very important task for future research analysis and development of intervention strategies.