• Title/Summary/Keyword: watertable

Search Result 5, Processing Time 0.02 seconds

Analysis of Ground Watertable Fluctuation at the Sandy Barrier Island on Jinu-do in Nakdong River Estuary (낙동강 하구역 진우도 자연해빈의 지하수위 변동해석)

  • Park, Jung-Hyun;Yoon, Han-Sam;Lee, In-Cheol
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.20 no.4
    • /
    • pp.382-388
    • /
    • 2014
  • This study selected five observational stations in the normal direction of Jinu-do(island) shoreline and observed water temperature, electrical conductivity and pressure from March, 2012 to January, 2013(about 11 months) and attempted to see the variation characteristics of ground watertable. This study wants to know : 1) External environment force factors(tide, climate, wave etc.) affecting ground watertable variation through time series and correlation analysis. 2) Spatial variations of ground watertable and electrical conductivity change by storm event. First, we found that the station at the intertidal zone was strongly affected by wave and tide level and the stations at sand dune and vegetation zone was affected by precipitation and tide level through time series data and correlation analysis. Second, during the storm event, we found that ground watertable and electrical conductivity are stabilized at the start line of sand dune and vegetation zone and transition zone between freshwater layer and seawater layer exists in the experiment area and is about 50~70 m from coastline of the south side of Jinu-do(island).

Characteristics of pH, Electric Conductivity and Water Temperature of Groundwater in Yongnup, Daeam-san (대암산 용늪 지하수의 pH, 전기전도도, 수온 분포 특성)

  • 박종관
    • Journal of the Korean Geographical Society
    • /
    • v.38 no.1
    • /
    • pp.1-15
    • /
    • 2003
  • The basic data of groundwater quality such as water temperature, pH and electric conductivity were collected for 6 months from July to December 2000 in Yongnup. The results are as follows; the values of groundwater quality at the unsaturated points were beyond the distribution range when compared with those at fully saturated points. Temperature of groundwater in Yongnup increased with the rising of watertable. The values of pH were usually measured between 5.0 and 6.0, but sometimes those of lower than 4.0 were indicated. The value measured at unvegetated ground was higher than that at covered area. Also, the electric conductivity increased with the rising of watertable. The values of water quality between groundwater and surface water were quite different from each other and varied with seasonal change. The measured values of pH and electric conductivity had a proportional relationship.

Stability Analysis and Reinforcement of Large Excavated Slope considering Precipitation Infiltration in Rainy Season (강우침투로 인한 대절취사면의 붕괴안정성검토 및 대책)

  • Chun, Byung-Sik;Choi, Hyun-Seok
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.4 no.1
    • /
    • pp.101-110
    • /
    • 2000
  • In case heavy rainfall is a key factor of slope failure, the failure zone is usually developed within the depth of 3~5m from the ground surface regardless of the location of the watertable. If rainfall is taken into consideration, it is general that the slope stability analysis is carried out under the assumption that the cut slope is saturated to the slope surface or the watertable elevates to a certain height so that ${\gamma}_{sat}$, the unit weight of saturated soil, is used. However, the analysis method mentioned above can't exactly simulate the variation of pore water pressure in the slope and yields different failure shape. The applicability of slope stability analysis method considering the distribution of pore water pressure within the slope with heavy rainfalls, was checked out after the stability analysis of a lage-scale cut slope in a highway construction site, where surface failure occurred with heavy rainfalls. An appropriate slope stabilization method is proposed on the base of the outcome of the analysis.

  • PDF

Application of Geophysical Methods to Detection of a Preferred Groundwater Flow Channel at a Pyrite Tailings Dam (황철석 광산 광미댐에서의 지하수흐름 경로탐지를 위한 물리탐사 적용)

  • Hwang, Hak Soo
    • Economic and Environmental Geology
    • /
    • v.30 no.2
    • /
    • pp.137-142
    • /
    • 1997
  • At the tailings dam of the disused Brukunga pyrite mine in South Australia, reaction of groundwater with the tailings causes the formation and discharge of sulphuric acid. There is a need to improve remediation efforts by decreasing groundwater flow through the tailings dam. Geophysical methods have been investigated to determine whether they can be used to characterise variations in depth to watertable and map preferred groundwater flow paths. Three methods were used: transient electromagnetic (TEM) soundings, direct current (DC) soundings and profiling, and self potential (SP) profiling. The profiling methods were used to map the areal extent of a given response, while soundings was used to determine the variation in response with depth. The results of the geophysical surveys show that the voltages measured with SP profiling are small and it is hard to determine any preferred channels of groundwater flow from SP data alone. Results obtained from TEM and DC soundings, show that the DC method is useful for determining layer boundaries at shallow depths (less than about 10 m), while the TEM method can resolve deeper structures. Joint use of TEM and DC data gives a more complete and accurate geoelectric section. The TEM and DC measurements have enabled accurate determination of depth to groundwater. For soundings centred at piezometers, this depth is consistent with the measured watertable level in the corresponding piezometer. A map of the watertable level produced from all the TEM and DC soundings at the site shows that the shallowest level is at a depth of about 1 m, and occurs at the southeast of the site, while the deepest watertable level (about 17 m) occurs at the northwest part of the site. The results indicate that a possible source of groundwater occurs at the southeast area of the dam, and the aquifer thickness varies between 6 and 13 m. A map of the variation of resistivity of the aquifer has also been produced from the TEM and DC data. This map shows that the least resistive (i.e., most conductive) section of the aquifer occurs in the northeast of the site, while the most resistive part of the aquifer occurs in the southeast. These results are interpreted to indicate a source of fresh (resistive) groundwater in the southeast of the site, with a possible further source of conductive groundwater in the northeast.

  • PDF

Groundwater and Small Stream Water Quality Changes of Rural Watersheds in Kangwon-do (강원도 농업소유역의 지하수 및 지표수 수질의 계절적 변화에 관한 연구)

  • 최중대;이찬만;김도환
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 1998.10a
    • /
    • pp.558-564
    • /
    • 1998
  • Flow rate, watertable and selected water quality of 2 small rural streams and 6 observation well located in Kangwon-do, Korea, were monitored land use of the watersheds was investigated to describe the trend of stream water quality for 2 years and groundwater quality for 1 year. Water qualities were analyzed with respect to BOD, SS, T-N, Nitrate, T-P and E-coli. Stream water quality and gorundwater quality directly concerned with the amount of rainfall and paddy fields. but water quality of watersheds is existed with other factor. Therefore, We have to continued monitoring and developing the best management practice.

  • PDF