• Title/Summary/Keyword: water-treatment

Search Result 12,111, Processing Time 0.037 seconds

Evaluation of Pressurized Water Mixing of Big Pipe with CFD at Water Treatment Process (CFD를 활용한 수처리공정 대형관에서 압력수 혼합공정 평가)

  • Cho, Young-Man;Yu, Hyun-chul;Jang, Gyeong-Hyuk;Jung, Yong-Jun
    • Journal of Korean Society on Water Environment
    • /
    • v.37 no.3
    • /
    • pp.168-174
    • /
    • 2021
  • Mixing is a very important unit in water treatment process. A mechanical stirring method is generally used for mixing, but recently, the use of pressurized water mixing method (pump diffusion flash mixer) has gained interest because it is more advantageous in terms of mixing time, noise, energy consumption, and maintenance. The following conclusions were obtained from the study of pressurized water mixing method by Computational Fluid Dynamics. Firstly, the mixing degree in the pipe increased as the density of water increased. Secondly, even if the relative velocity between flow rate in the pipe and the pressurized water was constant, the mixing degree decreased as the flow velocity in the pipe increased. Thirdly, the stronger the injection energy the higher the mixing degree. It was also found that the mixing degree was greatly affected by the injection velocity as compared to the injection flow amount. Finally, the required energy to achieve 95% mixing degree at the distance of 10 times diameter in big pipes of 500 mm to 3000 mm was 0.3 to 4.5 kJ. The result of this study could be used in the process design of injection with water purification chemicals, such as, ozone, chlorine, and coagulant.

Impact Analysis of Construction of Small Wastewater Treatment Plant Under Climate Change (기후변화를 고려한 소규모 하수처리장 건설에 대한 영향 분석)

  • Park, Kyungshin;Chung, Eun-Sung;Kim, Sang-Ug;Lee, Kil Seong
    • Journal of Korean Society on Water Environment
    • /
    • v.26 no.2
    • /
    • pp.268-278
    • /
    • 2010
  • This study derived the effectiveness analysis results of construction of wastewater treatment plant under climate change scenarios. Canadian Global Coupled Model (CGCM3) was used and A1B and A2 of Special Report on Emission Scenario (SRES) were selected. Regional climate change data for this application were downscaled by using Statistical Downscaling Model (SDSM) and the flow and BOD concentration durations were obtained by using Hydrological Simulation Program - Fortran (HSPF). The criteria for low flow and water quality were chosen as $Q_{99}$, $Q_{95}$, $Q_{90}$ and $C_{30}$, $C_{10}$, $C_1$. The numbers of days to satisfy the instreamflow requirements and target BOD concentration were also added to the criteria for comparison. As a results, small wastewater treatment plant improved the water cycle due to the increase of low flow and the decrease of BOD concentration. But climate change affected the reduction of effectiveness significantly. Especially in case of construction of small waste water treatment plant in the upstream region, it is necessary to take climate change impact into consideration since it is usually related to the low flow and the water quality of the stream.

Hwa-Byung Treated by Using Ascending Kidney Water and Descending Heart Fire Pharmacopuncture: Three Case Studies

  • Jo, NaYoung;Roh, JeongDu
    • Journal of Pharmacopuncture
    • /
    • v.20 no.2
    • /
    • pp.132-138
    • /
    • 2017
  • Objectives: We report the results of three case studies on the clinical efect of ascending kidney water and descending heart fre (AKDH) pharmacopuncture on patients with Hwa-Byung. Methods: Tis study involved three patients, all female, who had been admitted to a hospital of traditional Korean medicine and had been diagnosed as having Hwa-Byung by using the Hwa-Byung Structure Clinical Interview for DSM-IV. AKDH pharmacopuncture is administered by injecting pharmacopuncture at a specifc acupoint to change from a state of water-fre disharmony to one of water-fre harmony. For our three patients, Hwangyeonhaedoktang (黃連解毒湯) pharmacopuncture was injected at GB21 and GB20 on both sides; a total of 0.4 cc was injected, with 0.1 cc being injected at each point. Fel ursi, Bezora bovis and moschus (BUM) pharmacopuncture was injected at CV17, CV12, and CV6; a total of 0.15 cc was injected, with 0.05 cc being injected at each point. Treatment was done daily. Progress was evaluated using the Hwa-Byung diagnostic interview (HBDIS), beck depression inventory (BDI), and numeric rating scale (NRS) scores. Results: For the frst patient (case 1), after treatment, the HBDIS score was reduced from 44 to 30 points, the BDI score from 37 to 14, and the NRS score from 10 to 7. For the second patient (case 2), after treatment, the HBDIS score was reduced from 41 to 27 points, the BDI score from 13 to 7, and the NRS score from 10 to 5. For the third patient (case 3), after treatment, the HBDIS score was reduced from 42 to 28 points, the BDI score from 12 to 9, and the NRS score from 10 to 4. Conclusion: Ascending kidney water and descending heart fre pharmacopuncture treatment can be efective for improving ascending kidney water and descending heart fre energy and can be used to alleviate Hwa-Byung.

A Study on the Sterilization Effect of Ballast Water according to the Combination of Types of Treatment Apparatus (선박평형수 처리장치의 조합에 따른 살균효과에 관한 연구)

  • Kang, Ah-Young;Kim, Sang-Pil;Song, Ju-Yeong
    • Journal of the Korean Applied Science and Technology
    • /
    • v.32 no.3
    • /
    • pp.412-417
    • /
    • 2015
  • The purpose of this study is to treat the ballast water by shear stress without an environmental pollution and to find out the optimal treatment conditions. The ballast water problem is issued up as the trade activated and the cargos mobilized. To improve this problem, International Marine Organization(IMO) make the rule about the ballast water treatment with specific restrictions. Although many countries have been studying about the ballast water treatment technology, there is almost no technology that can treat the microorganisms under $50{\mu}m$ without any secondary pollution. In this study, we tried to treat ballast water by applying shear stress as the physical treatment for the sterilization and tried to find out the optimal conditions including the 100% sterilizing rate and the best economic condition.

Effects of Electrolyzed Water and Chlorinated Water on Sensory and Microbiological Characteristics of Lettuce (양상추의 관능적 및 미생물학적 특성에 전해수 및 염소수가 미치는 영향)

  • Lee Seung-Hyun;Jang Myung-Sook
    • Korean journal of food and cookery science
    • /
    • v.20 no.6 s.84
    • /
    • pp.589-597
    • /
    • 2004
  • This study was conducted to investigate the effects of various kinds of electrolyzed and chlorinated waters on the sensory and microbiological qualities of fresh-cut lettuce and to determine the most suitable electrolyzed water for the vegetable dishes, without heat treatment, at institutional foodservices. The sensory evaluation resulted in higher scores on the 1st-day of storage for the EW-1 (diaphragm type 1) and EW-3 (non-diaphragm type) compared to that for EW-2 (diaphragm type 2), with regard to their appearance, discoloration, texture, taste and overall acceptability characteristics. However, over time, EW-3 ranked highest, with a score of 8.00 (very like), on the 4th-day of storage, which maintained the highest level up to the 7th-day of storage, at which time the score was 7.00 (fairly like). The CW (chlorinated Water) had a significantly lower score, due to the smell of chlorine, although there was no concern with relation to chlorine residue from the electrolyzed waters. Microbial examinations of the total plate count revealed that immersing lettuce into EW-3 brought about l/3,000 to 1/30,000 reductions in the microbial counts of the TW treatment or untreated samples for up to seven days of storage. The CW treatment gave a 1/10 reduction in the microbial counts compared with the TW (tap water) treatment. The coliform bacterial counts also showed similar trends to those of the total plate count values. With regards to the psychotropic bacterial count, EW-3 was able to result in as much as a 1/30,000 reduction in the initial counts. As vegetable dishes, such as salad, can not be heat-sterilized, the utilization of EW-3 for the preparation of vegetable dishes without heat treatment will be an excellent choice to improve the critical control point in production state as a new effective means for sanitizing management.

A study on the strategy of concerned parties with regard to the performance standards and implementation schedule of ballast water treatment systems (평형수처리장치 성능기준 및 시행시기 차이에 의한 관련 당사자들의 대응전략 연구)

  • Kim, Kyong-Min;Kim, Hoi-Jun;Ha, Weon-Jae
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.3
    • /
    • pp.325-332
    • /
    • 2014
  • In installing ballast water treatment system, the cost of the system is high and many technical aspects are to be considered and also it takes significant time to retro-fitting on the existing ships. In addition, in the current circumstance which the Ballast Water Management Convention has not been entered into force, the 28th IMO Assembly adopted a resolution to mediate the implementation schedule of the treatment systems. In the mean time, California State and New York State have declared more stringent discharge requirements of ballast water and are planning to implement them earlier than the schedule of the Convention. In these circumstances, the implication in the difference between ballast water treatment system manufacturers and ship owners need to be considered. In this study, through the review on the considerations when installing the system onboard, stringent requirements of United States of America, and determent or mediated implementation schedules of Convention and California and New York States, the author would like to suggest the strategy of concerned parties for anticipated entrry into force of the Convention and implementation of the stringent requirements of United States of America.

Impact of Pig Slurry from WangGoong Farm Cluster on Water Quality of the Iksan Stream

  • Choi, Hong-Lim;Suresh, A.;Babu, T.;Mansyur, Mansyur
    • Journal of Animal Science and Technology
    • /
    • v.53 no.6
    • /
    • pp.549-561
    • /
    • 2011
  • Livestock wastewater is being discharged without treatment from Hasen's pig farm cluster in WangGoong (WG) area into the Iksan Stream, eventually flowing into the ManGyung (MG) at the upstream junction. Although it is well known that before discharge, wastewater must satisfy the pig slurry discharge standards; because of ongoing remodeling, proper treatment is not being performed. According to public records, wastewater from the WG pig farm cluster is responsible for 3.6% of MG River pollution and 2.0% of the SaeManGuem (SMG) Reservoir pollution. As a result, upstream water treatment quality has become primary concern for development of the SMG project. All physicochemical constituents and pathogenic microbes, such as chemical oxygen demand ($COD_{Cr}$), biochemical oxygen demand ($BOD_5$), total suspended solids (TSS), total nitrogen (TN), total phosphorous (TP), fecal coliforms, Escherichia coli and Salmonella at the effluent of WG Plant (S-1) exceed the effluent standards. This is mainly due to insufficient wastewater treatment: the WG Plant is under renovation to increase water purification efficiency. By comparing the water quality at the S-7 junction, where the the Iksan Stream (pig farms) and the Wanggoong Stream (no pig farms) merge, it is clear that farming facilities and improper treatment can critically affect surrounding water quality. While it is clear throughout this study that the level of all physicochemical parameters and pathogenic microbes along the Stream decreased due to sedimentation, biodegradation and/or dilution. An alarming problem was discovered: the existence of pathogenic microbe count(E coli, Salmonella) in the lagoon wastewater and the stream water. Not only were high concentrations of these pathogens themselves found, but the potential existence of more serious pathogens could rise to more dangerous conditions.

Development of Biological Filtration Process for Effective Nitrogen Removal in Tertiary Treatment of Sewage (생물막 여과반응기를 이용한 고도질소 제거법의 개발)

  • Jeong, Jin-Woo;Kim, Sung-Won;Tsuno, Hiroshi
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.2
    • /
    • pp.222-229
    • /
    • 2006
  • The treatment performance and operational parameters of a tertiary wastewater treatment process a biological filtration system were investigated. The biological filtration system consisted of a nitrification filter (Fiter 1) and a polishing filter with anoxic and aerobic parts (Filter 2). SS, T-C-BOD, and T-N in effluent were kept stable at less than 3, 5 mg/L, and 5 mgN/L, respectively, under a HRT in Filter (filter-bed) of 0.37~2.3 h. T-N at the outlet of Filter 2 were about 1~5 mgN/L under the condition of LV of 50~202 m/d. In Filter 2, denitrification was accomplished under LV of 50~168 m/d in a 1 m filter-bed. However, the denitrification capacity reached the maximum when the linear velocity was increased to 202 m/d. Relationship between increase in microorganism and headloss was clearer in Filter 2. As a result, the denitrification rate increased from 1.0~2.3 kgN/($m^3-filter-bed{\cdot}d$) as the headloss increased. The COD removal rate was 6.0~9.6 kgCOD/($m^3-filter-bed{\cdot}d$) when operated with Filters 1 and 2. These results mean that captured bacteria contributed a part of COD consumption and denitrification. The maximum nitrification and denitrification rate was 0.5 and 4 kgN/($m^3-filter-bed{\cdot}d$) in Filter 1 and 2.The ratio of backwashing water to the treated water was about 5~10 %. In Filter 1, wasted sludge in backwashing was only 0.7~5.3 gSS/($m^3$-treated water). In Filter 2, added methanol was converted into sludge and its value was 8.0~24 gSS/($m^3$-treated water). These results proved that this process is both convenient to install as tertiary treatment and cost effective to build and operate.

Monitoring of Changes in Molecular Weight Distribution and Fluorescence Properties of Dissolved Matter (DOM) in Water Treatment Processes (정수처리공정 중 자연유기물질의 분자량 분포 및 형광특성 변화 모니터링)

  • Park, Min-Hye;Hur, Jin
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.6
    • /
    • pp.843-849
    • /
    • 2007
  • Monitoring of NOM characteristics is important for improving removal efficiency of natural organic matter (NOM) in water treatment processes. In this study, several NOM characteristics, which include specific UV absorbance (SUVA), total carbonate content, molecular weight distribution, and fluorescence properties, were measured using samples collected from a pilot-scale water treatment plant consisting of coagulation/flocculation (C/F), filtration, ozonation and granular activated carbon (GAC) processes. The highest removal of NOM was observed in C/F and filtration processes as demonstrated by the reduction of dissolved organic carbon (DOC) by 25% and 21%, respectively. Despite nearly no change in DOC, however, the lowest SUVA value and the highest total carbohydrate content were observed in the sample from ozonation process. This indicates that non-degradable aromatic compounds become depleted and biodegradable organic compounds are enriched during the process. Comparison of synchronous fluorescence spectra of the samples showed that ozoation process increased protein-like fluorescence while it decreased fulvic-like and terrestrial humic-like fluorescence. Consistently, a slight peak of protein-like fluorescence was observed in the sample from ozonation process. The greatest change in molecular weight distributions of the samples was observed in C/F process. Comparison of size exclusion chromatogram of the samples revealed that NOM fractions with the molecular weight greater than 2000 Da were reduced by over 90% after C/F process. SUVA values and total carbohydrate content of the samples were well correlated with a ratio of protein-like fluorescence and terrestrial humic-like fluorescence intensities with the correlation coefficients of 0.99 and 0.91, respectively. This suggests that synchronous fluorescence properties of NOM could be used as useful tolls for monitoring changes of some NOM characteristics during water treatment processes.

Status of Membrane Filtration in Japan : Application for Water Supply

  • Minami, Katsuyoshi
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1997.04a
    • /
    • pp.55-62
    • /
    • 1997
  • In Japan, the membrane filtration is becoming a common technology for municipal water supply system especially for small plant. 6 years before (1991), the national research project of membrane filtration for small plant has started. The project was named as "MAC 21", MEMBRANE AQUA CENTURY 21. In the project the Ministry of Health and Welfare, 8 universities and 18 water treatment plant companies have been involved. This was the first attempt to research a common theme in joint with government, universities and private companies. After three years, the guide line for membrane filtration application for small plant has been established. This has promoted to install some actual plant. And also, another joint research for "RESEARCH OF MEMBRANE FILTRATION FOR ADVANCED WATER TREATMENT" has started in 1994 and completed in March, 1997. The project was named as MAC21. In the former project the main objectives were removal of turbidity and bacteria from water. However, in new project the objective was establishment of the further advanced membrane filtration technology which would be applicable for trace chemical components removal such as tri-halo-methane pre-courser, agricultural chemicals removal, offensive smell and taste removal and virus removal. For the objectives, application of nanofiltration and hybrid-system, a combination of micro-filtration ultra-filtration with biological, ozone and activated carbon treatment process have been studied. In addition, application of membrane filtration for treatment of back-wash waste water originated from membrane filters and conventional sand filters has.been studied. At the end of March of this year, about 30 membrane filtration plants are actually supplying the water, the total treatment capacity is about 6,000 m$^{3}$/day and another 20 will be installed within one year.led within one year.

  • PDF