• Title/Summary/Keyword: water-treatment

Search Result 12,111, Processing Time 0.047 seconds

Cause of Filtrate Deterioration and Its Improvement in Rapid Filtration (급속여과공정에서 여과수질 저하원인 및 개선방안)

  • Kim, Jin-Keun;Lee, Song-Hee;Kim, Jae-Won
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.24 no.3
    • /
    • pp.333-339
    • /
    • 2010
  • Particle removal is an important step taken at water treatment plants (WTPs) for the safety of tap water due to its proportionality to the pathogen inactivation. Government promulgated a treatment technique for the optimization of filtration including continuous turbidity monitoring using on-line turbidimeters. Based on the turbidity measurements of 460 filters at 31 WTPs operated by K-water, the evaluation of filtration performance and the investigation of major causes related to particle breakthrough were explored. 98.1 % of the filters had an effluent turbidity measurement which was less than 0.1 NTU, but turbidity breakthrough of more than 0.3 NTU was noticed occasionally which is in violation of AWWA 5-Star guidelines. It was shown that the optimization of coagulation, filter-to-waste, the observance of optimal filtration velocity and backwashing process based on filtrate turbidity were crucial for the improvement of filtrate.

Analyses Water Balance for Ponding depth Treatment (논 담수심처리에 따른 물수지 분석)

  • Sohn, Seung-Ho;Park, Ki-Jung;Chung, Sang-Ok
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2003.10a
    • /
    • pp.263-266
    • /
    • 2003
  • The purpose of this study is to investigate the effects of ponding depth treatment on water balance in paddy fields. The ponding depth treatments were very shallow, shallow and deep. Daily values of rainfall amount, ponding depth, irrigation water, drainage water, evapotranspiration, and infiltration were measured in the field. The medium ponded plots saved irrigation water about 16% to 53.4% without any statistical difference in rice growth and yields. Hence, the medium ponded depth treatment is better than the traditional deep ponded depth to save water in the transplanted rice culture.

  • PDF

Research of Sludge Quantity and Evaluation of Sludge Handling Facilities in Water Treatment Plants (정수 슬러지 발생량 조사 및 슬러지 처리시설의 공정평가)

  • Moon, Seong-Yong;Kim, Seung-Hyun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.3
    • /
    • pp.279-290
    • /
    • 2004
  • Sludge quantity has increased at "A"water treatment plant due to deterioration of raw water quality and GAC installation. Increased sludge resulted in overloading on sludge handling facilities. The object of this study is to survey sludge quantity and capacity of sludge handling facilities at "A"water treatment plant. Measured quantity of sedimentation sludge considerably exceeded the design capacity of sludge holding basin. Sludge holding basin was properly designed, but low concentration of sludge discharged from sedimentation basin caused production of large volume of the sludge. Timer operated control system for sludge withdrawal unit and leakage through a control valve were suspected to cause the low concentration. Augmentation of the control system by a turbidity meter and addition of a new control valve successfully reduced the sludge volume enough to satisfy the design capacity of sludge holding basin. Unlike sedimentation sludge, measured quantity of washwater was considerably less than the design capacity of washwater basin because it was over-designed.

Membrane Filtration Technology for Drinking Water Treatment & Night Soil Treatment

  • Kato, Yasuhiko
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1998.06a
    • /
    • pp.155-170
    • /
    • 1998
  • 1. The flux for hydrophilic CA membrane is higher than that for hydrophobic PES membrane at any operating conditions. The difference in bpth fluxes becomes greater as the water recovery is lower. 2. Backwash pressure should be more than twice as high as filtration pressure in order to maintain the higher flux. Backwash frequency is independent of the flux when the UF is operated under the same water recovery. 3. The relatively lower crossflow velocity of around 0.1 m/s would be appropriate because of the lower energy consumption per treated water. 4. The membrane fouling occurring at high turbidity and high concentration of organic compounds in raw water can reduce the flux and increase the removal of the organic compounds. 5. It is confirmed by the pilot plant testing that the UF by using the CA membrane module was well applicable to the drinking water treatment.

  • PDF

A Study on the Correct injection method for low dissolution liquid in the Water Treatment Plant (상수도의 저용해성 액체 정량투입 방안 연구)

  • Kim, Jin-Hoon;Park, Jong-Ho
    • 유체기계공업학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.273-277
    • /
    • 2005
  • The large particles of suspended matter in raw water can be removed by allowing them to settle out in a presedimentation basin. But there are smaller particles in almost all surface water and some groundwater that will not settle out within a reasonable time without some help to accelerate the process, In the coagulation and flocculation processes, nonsettleable solids are converted into large and heavier settleable solids by physical-chemical changes broght about by adding and mixing coagulant chemicals into the raw water. The object of this research was to improve corrective injection method for low dissolution liquid in the water treatment plant. A sort of chemical feed equipment are diaphram pump, flow control in combined magnetic flowmeter md control valve, roto dipper wheel system and tube pump. Particularly low dissolution liquid (Calcium Hydroxide) put in a bit by feed equipment, tube pump is very useful method for corrective injection method in the water treatment plant.

  • PDF

A Study on the matter of Disinfection in UV/TiO2 Water Treatment process (UV/TiO2 수처리 공정에서의 살균에 관한 연구)

  • Lee, Gyu-Hwan;Lee, Sang-Jin;Lee, Yong-Jae;Rhee, Dong-Seok
    • Journal of Industrial Technology
    • /
    • v.27 no.A
    • /
    • pp.15-18
    • /
    • 2007
  • This study investigated disinfection effect by general water purifier and water purifier with UV light disinfection. The results are as follows : (i) The general bacteria existed plentifully in a storage tank before treatment (ii) Water treated in water purifier did not meet the water treatment regulation standard since the presence of bacteria, whereas with UV light application the regulation standard is totally satisfied. (iii) Photocatalytic disinfection process with UV light in the presence of $TiO_2$ more effectively killed general bacteria than UV light only.

  • PDF

Development of a robust bench-scale testing unit for low-pressure membranes used in water treatment

  • Huang, Haiou;Schwab, Kellogg;Jacangelo, Joseph G.
    • Membrane and Water Treatment
    • /
    • v.2 no.2
    • /
    • pp.121-136
    • /
    • 2011
  • A bench-scale test has recently been proposed as a predictive tool to minimize the scope of pilot-scale testing or to optimize the operation of full-scale membrane filtration systems. Consequently, a bench-scale testing unit was developed for this purpose and systematically evaluated in this study. This unit was capable of accommodating commercially available, low pressure, hollow fiber (LPHF) membranes with various configurations for testing under conditions comparable to real-world applications. Reproducibility of this unit in assessing membrane fouling and microbial removal efficiency of LPHF membranes was tested and statistically comparable results were obtained. This unit serves as a useful apparatus for academic researchers and utilities to evaluate the performance of LPHF membranes used for water treatment.

Effects of sodium hydroxide cleaning on polyvinylidene fluoride fouled with humic water

  • Jang, Yoon-sung;Kweon, JiHyang;Kang, Min-goo;Park, Jungsu;Jung, Jae Hyun;Ryu, JunHee
    • Membrane and Water Treatment
    • /
    • v.8 no.2
    • /
    • pp.149-160
    • /
    • 2017
  • This study investigated effects of NaOH cleaning on the intrinsic permeability of polyvinylidene fluoride (PVDF) membranes and flux recoveries and membrane resistances under various conditions encountered during ultrafiltration in water treatment plants. The NaOH cleaning using 10,000 mg/L NaOH led to discoloration of PVDF membranes and had little effect on water flux. The NaOH cleaning was efficient in removing the fouling layer caused by humic water. However, long filtration induced a fouling layer that was not removed easily by NaOH cleaning. The lower temperature during filtration yielded rapid increases in transmembrane pressure and decreases in NaOH cleaning efficiency. The alkaline cleaning of PVDF changed the membrane properties such as the hydrophobicity and morphology. Foulant properties, operational conditions such as temperature, and chemical agents should be considered for cleaning strategies for PVDF applied in water treatment.

Corrosivity Characteristics of Raw Water in Korea (국내 상수원수의 부식성 특성)

  • Kim, Jin-Keun;Kim, Jae-Won
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.6
    • /
    • pp.839-846
    • /
    • 2011
  • To investigate corrosivity characteristics of raw water in Korea, Langelier index (LI) of 30 multi-regional water treatment plants (WTPs) were evaluated. Annual average values of LI at 30 WTPs were all negative, which means raw water in Korea is very corrosive. LI results for 4 major rivers showed that raw water from Han and Nakdong had relatively high values compared to those of Sumjin and Keum. On the other hand, LI values of raw water from the tributaries of four major rivers were relatively low presumably due to geological characteristics, and in some cases the values were less than -4.0 which means increase of LI is urgently needed to minimize red water problem. Based on the correlation results among LI and water quality parameters, pH, water temperature, calcium concentration were confirmed as major components for LI. Therefore, pH and calcium concentration control is an effective method for the improvement of LI in water treatment processes.

Introduction of Water Quality Certification System for Confidence Improvement of Tap Water (수돗물 신뢰도 향상을 위한 품질 인증 제도 도입)

  • Kim, Jinkeun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.29 no.2
    • /
    • pp.155-163
    • /
    • 2015
  • Many advanced treatment processes have been introduced to WTPs, however, the consumer confidence on tap water is still low and the percentage of drinking water directly from the tap is less than 2 %. One of the methods to improve the credibility of tap water is to introduce a drinking water certification system. By introducing the system, water treatment processes can be optimized, which in turn, can significantly improve drinking water quality. In this paper, 6 water quality parameters(i.e., turbidity, CT, residual chlorine, geosmin, 2-MIB, Mn) which have significant influences on tap water quality and consumer confidence were identified, and their recommended guidelines were proposed. 3-Star or 5-Star certification can be awarded to the WTPs which have met the certification criteria. The drinking water certification system can be carried out as a voluntary program among drinking water suppliers.