• Title/Summary/Keyword: water-quality monitoring

Search Result 1,052, Processing Time 0.027 seconds

Temporal and spatial variation analysis on nutritive salt of Hongze Lake

  • Zhang, Min;Chu, Enguo;Xu, Ming;Guo, Jun;Zhang, Yong
    • Environmental Engineering Research
    • /
    • v.20 no.1
    • /
    • pp.19-24
    • /
    • 2015
  • This paper mainly focuses on the research of the monitoring data about the total nitrogen (TN), total phosphorus (TP) of ten monitoring points of Hongze Lake in 28 years. Our study adopts the technical methods such as difference comparison, correlation analysis, Mann-Kendall, etc. to analyze the statistical characteristics, regional differences, and temporal and spatial variation condition of ten monitoring points of Hongze Lake in 1986-2013 as well as the reason for the time and space variation of TN and TP. The results show that the TN and TP of Hongze Lake change dramatically during the period of 1994-2004. In all the monitoring periods, TN and TP of the HZ5, HZ6, HZ7, HZ8 monitoring points in the estuary surrounding the Huaihe River are the highest, which suggests that TN and TP of Hongze Lake should not be ignored for the pollution along the Huaihe River. The TN concentration in the core area is the highest, but that in the development control area is the lowest. In most of the years, TN concentration is higher than 2 mg/L, and the water quality is V class and poor V class water quality in China's Environmental Quality Standards for Surface Water (GB3838-2002). TP concentration of the three areas is basically close, that is lower than 2 mg/L in most of the years, and the water quality is within the V class. The TN and TP concentration of Hongze Lake decreased and intensifying trend of eutrophication is controlled after 2004.

A Non-parametric Analysis of the Tam-Jin River : Data Homogeneity between Monitoring Stations (탐진강 수질측정 지점 간 동질성 검정을 위한 비모수적 자료 분석)

  • Kim, Mi-Ah;Lee, Su-Woong;Lee, Jae-Kwan;Lee, Jung-Sub
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.6
    • /
    • pp.651-658
    • /
    • 2005
  • The Non-parametric Analysis is powerful in data test especially for the non- normality water quality data. The data at three monitoring stations of the Tam-Jin River were evaluated for their normality using Skewness, Q-Q plot and Shapiro-Willks tests. Various constituent of water quality data including temperature, pH, DO, SS, BOD, COD, TN and TP in the period of January 1994 to December 2004 were used as dataset. Shapiro-Willks normality test was carried out for a test 5% significance level. Most water quality data except DO at monitoring stations 1 and 2 showed that data does not normally distributed. It is indicating that non-parametric method must be used for a water quality data. Therefore, a homogeneity was conducted by Mann-Whitney U test (p<0.05). Two stations were paired in three pairs of such stations. Differences between stations 1, 2 and stations 1, 3 for pH, BOD, COD, TN and TP were meaningful, but Tam-Jin 2 and 3 stations did not meaningful. In addition, a narrow gap of the water quality ranges is not a difference. Categories in which all three pairs of stations (1 and 2, 2 and 3, 1 and 3) in the Tam-Jin River showed difference in water quality were analyzed on TN and TP. The results of in this research suggest a right analysis in the homogeneity test of water quality data and a reasonable management of pollutant sources.

Ecological Risk Assessment of Chemicals of Concern for Initiation of Ecorisk-based Water Quality Standards in Korea (생태수질기준설정을 위한 대상물질의 생태위해성 평가)

  • An, Youn-Joo;Nam, Sun-Hwa;Kim, Yong-Hwa
    • Journal of Korean Society on Water Environment
    • /
    • v.24 no.5
    • /
    • pp.592-597
    • /
    • 2008
  • Current water quality standard (WQS) in Korea is based on the protection of human health, not considering the protection of aquatic organisms. Most of chemicals can be toxic to ecological biota as well as human. Health of aquatic biota is closely related to the human health via food chain, therefore ecological risk based-WQS needs to be developed to protect the aquatic ecosystem. In this study, we selected the 31 chemicals in the Project entitled 'Development of integrated methodology for evaluation of water environment'. The methodology for calculating water quality criteria was derived from the Australian and New Zealand processes for deriving guideline trigger value for aquatic ecosystem. The available ecotoxicity data were collected from US EPA's ECOTOXicology Database (ECOTOX), TOX-2000 Database, European Chemicals Bureau (ECB)'s International Uniform Chemical Information Database (IUCLID) and Environmental Protection Agency (US EPA)'s report 'Ambient Water Quality Criteria (AWQC)'. The aquatic toxicity data for the Korean species were selected for risk assessment to reflect the Korean water environment. The monitoring values were calculated from the water quality monitoring data four main Korean rivers. We suggested the order of priorities of chemicals based on ecological risk assessment. We expect that these results can be useful information for establishing the WQS for the protection of aquatic ecosystem.

A study on seasonal characteristics through long-term water quality monitoring in the Nakdong River Watershed (낙동강유역 장기 수질모니터링을 통한 계절적 특성분석 연구)

  • Kal, Byungseok;Park, Jaebeom;Kim, Seongmin;Shin, Sangmin;Jang, Soonja;Jeon, Minjae
    • Journal of Wetlands Research
    • /
    • v.24 no.4
    • /
    • pp.301-311
    • /
    • 2022
  • The purpose of this study is to analyze the seasonal characteristics of water quality using long-term water quality monitoring data. Seasonal characteristics of water quality were analyzed using monitoring data from 34 tributaries where long-term monitoring was performed in the Nakdong River system, and average data analysis of water quality, coefficient of variation analysis, and trend analysis were performed for seasonal analysis. For seasonal analysis, average data analysis of water quality, coefficient of variation analysis, and trend analysis were performed. As a result of the evaluation of the coefficient of variation, tributaries were larger than main streams, and BOD, T-P, and TOC were larger in autumn and T-N were larger in spring. Trend analysis was analyzed using Mann-Kendall and Sen's Slope. BOD, T-N, and T-P tended to decrease, but TOC had a lot to increase. Through this study, it was possible to evaluate the availability of long-term water quality monitoring data and analyze seasonal characteristics, and to analyze the stabilization period of water quality and changes in pollutant sources for watershed management.

The Comparative Analysis of Water Quality Environment Data of Wando Onshore Seawater Farm and Tidal Observatory (완도 육상 해수 양식장과 조위관측소의 수질 환경 데이터 비교 분석)

  • Ye, Seoung-Bin;Kwon, In-Yeong;Kim, Tae-Ho;Park, Jeong-Seon;Han, Soon-Hee;Ceong, Hee-Taek
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.16 no.5
    • /
    • pp.957-968
    • /
    • 2021
  • To improve the data on reliability of the onshore fish farm water quality monitoring system and operate the system efficiently, the water quality data of the onshore seawater fish farms which are progressing test operation, and the marine environmental information network(Wando tidal station) were compared and analyzed. Furthermore, data validation, data range filters, and data displacement checks were applied to analyze the data in a way that eliminates the data errors in water quality monitoring systems and increases the reliability of measurement data.

Establishment of Non-drinking Groundwater Quality Standards: General Contamination Substances (비음용 지하수 오염물질 기준설정체계 구축 연구: (2) 일반오염물질)

  • An, Youn-Joo;Nam, Sun-Hwa;Jeong, Seung-Woo
    • Journal of Soil and Groundwater Environment
    • /
    • v.19 no.6
    • /
    • pp.24-29
    • /
    • 2014
  • To data, there was no systematic basis for establishing the content and allowed levels of general contamination substances in the Korean groundwater quality standards for non-drinking water. Recently, use of specific procedures for deriving valid groundwater quality standards have become mandatory. This study first investigated the methodology for deriving groundwater quality standards in the European Commission (EC), considering background groundwater quality and domestic and international standards related to water quality. Furthermore, this study investigated the existing specified procedure of standards related to water quality (e.g. surface water, drinking water, and wastewater). Our findings showed that EC and Member States presented the methods for deriving groundwater threshold values for general chemicals. Finally, we have proposed the following procedures of deriving Korean groundwater quality: (1) Selection of groundwater pollutant population, (2) selection and monitoring of priority substances, (3) monitoring, (4) selection of groundwater quality standard candidates, (5) selection of new substances and values for groundwater quality standards.

Water Quality Monitoring and Risk Assessment for Groundwater at Hoengseong, Gangwon-do Province (강원도 횡성지역의 지하수 수질 모니터링 및 인체 위해성 평가)

  • Gang, Seung-Hye;Kim, Ki-Tae
    • Journal of Environmental Health Sciences
    • /
    • v.47 no.4
    • /
    • pp.356-365
    • /
    • 2021
  • Background: Concerns have been raised regarding the criteria of groundwater, in particular in Gwangwon-do Province where many residents drink groundwater due to the poor supply of tap water and a high nonconformity rate with water quality criteria nationwide. Objectives: Water quality monitoring and risk assessment were conducted for groundwater in Hoengseong, Gangwon-do Province. Methods: A total of 46 items required for meeting drinking water criteria were analyzed from 258 samples collected from March 2017 through August 2018 (152 sites in 2017 and 106 sites in 2018). Risk assessment was conducted for two non-carcinogens (F- and NO3-N), and one carcinogen (i.e., arsenic) based on their high nonconformity to water quality criteria. Results: Water quality analysis revealed that the total proportion of nonconformities was determined to be 27.9%. The nonconformity rate for each content item is as follows: total colony counts (1.6%), total coliform (6.2%), Escherichia coli (1.2%), F- (8.1%), arsenic (4.7%), NO3-N (8.1%), pH (1.2%), manganese (0.4%), and turbidity (5.8%). Risk assessment indicated that fluoride induced a hazard quotient greater than 1 with the 95% UCL (Upper Confidence Limit) concentration of the total 258 sites and average, median, and 95% UCL concentrations of nonconformity sites. For NO3-N, there was no human health risk. For arsenic, the excess cancer risk exceeded the acceptable cancer risk of 1×10-6 with the average and 95% UCL concentrations of total 258 sites and average, median, and 95% UCL concentrations of nonconformity sites. Conclusions: This study suggests that it is necessary to expand water quality monitoring of groundwater and conduct a more detailed risk assessment in order to establish a health care plan for the residents of Hoengseong, Gangwon-do Province.

Effect of corrosive water quality control and corrosion index monitoring in pilot scale pipeline simulator (파일럿 규모 모의관로에서 부식성 수질제어 효과와 부식지수 모니터링)

  • Kim, Do-Hwan;Kim, Yung-Jin;Son, Hee-Jong;Ryou, Dong-Choon;Ahn, Jun-Young;Kim, Cheolyong;Hwang, In-Seong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.32 no.2
    • /
    • pp.183-192
    • /
    • 2018
  • Applicability of corrosion inhibitor was evaluated using pilot scale water distribution pipe simulator. Calcium hydroxide was used as corrosion inhibitor and the corrosion indices of the water were investigated. Corrosion indices, Langelier saturation index (LI) increased by 0.8 and calcium carbonate precipitation potential (CCPP) increased by 9.8 mg/L. This indicated that corrosivity of water decreased by corrosion inhibitor and the effects lasted for 18 days. Optimum calcium hydroxide dose was found to be 3~5 mg/L for corrosion inhibition. We suggest that monitoring of CCPP as well as LI need to be conducted to control corrosivity of water.

Monitoring on Water Quality Changes of Rural Watersheds in the North Han River Basin (북한강수계 농업 소유역의 수질변화 모니터링)

  • Choi, Joong-Dae;Yang, Jae E.;Kim, Do-Hwan;Choi, Byung-Yong;Choi, Kyoung-JIn;Park, Ji-Sung
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 1999.10c
    • /
    • pp.695-700
    • /
    • 1999
  • Stream and groundwater qualities of two rural watershes in the upper North Han river basin were monitored for 14months. Six to eight stream sampling sites and two to there groundwater monitoring wells were chosen and water samples were regularyl collected and analyzed with respect to total nitrogen(T-N), total phosphorus(T-P) and total suspended solids(TSS). Monitoring data were graphically analyzed with respect to time.Rainfall amout and intensity seemed to have an impact on stream T-N and T-P concentration changes. TSS concentrations were generally lower than the first class stream water quality standared, Both stream and groundwater qualities near livesstock feetlot areas were degraded indicating the feedlots have an impact on water quality.

  • PDF

Groundwater Quality in Gyeongnam Region Using Groundwater Quality Monitoring Data: Characteristics According to Depth and Geological Features by Background Water Quality Exclusive Monitoring Network (지하수수질측정망 자료를 활용한 경남지역 지하수 수질: 배경수질전용측정망에 의한 심도·지질별 특성)

  • Cha, Suyeon;Seo, Yang Gon
    • Clean Technology
    • /
    • v.26 no.1
    • /
    • pp.39-54
    • /
    • 2020
  • This study analyzed the groundwater quality according to the depth and geological features in Gyeongsangnam-do area using groundwater quality monitoring network data to grasp the groundwater quality characteristics and to provide basic data for policy making on efficient groundwater management. Five hundred and three data sets were acquired from background water quality exclusive monitoring network in soil groundwater information system for five years (2013 ~ 2017). Except for the total coliforms and tracer items such as mercury, phenol, and others, the parameters of water quality were significant or very significant, depending on depth and geological features. As the depth got deeper, the average value of pH and electrical conductivity increased; water temperature, dissolved oxygen, oxide reduction potential, arsenic, total coliforms, and turbidity decreased; and total unfit rate for drinking water standards was lower. It was found that the sum of the positive and negative ions was the highest in the clastic sedimentary rock and the lowest in metamorphic rock. The total unfit rate for drinking water standards was the highest for metamorphic rocks, followed by clastic sedimentary rock and unconsolidated sediments and, finally, intrusive igneous rock with the lowest penetration. The Na-Cl water type, which indicated the possibility of contamination by external pollutants, appeared only at some points in shallow depths and in clastic sedimentary rocks.