• Title/Summary/Keyword: water supply safety

Search Result 245, Processing Time 0.026 seconds

Comparison of Water Quality Between Private and Simple-Piped Drinking Water Supply in Rural Community (농촌지역 개인소유 음용수와 간이상수도의 수질에 대한 비교 연구)

  • 이진헌;이인숙
    • Journal of Environmental Health Sciences
    • /
    • v.20 no.1
    • /
    • pp.54-61
    • /
    • 1994
  • This study was carried out to investigate the degree of contamination in private-drinking water supply (PDWS) and simple-piped water supply (SPWS), and to compare of water quality between them for 3 years from 1990 to 1992. The results of the study were as follows: 1. Private-drinking water supply (PDWS) (1) Field-Site (ㄱ) The items which were very significantly over the criteria (p<0.01), were temp., pH, NO-N, standard plate count (S.P.C.) and Coliform. (ㄴ) No. of households which were over the criteria, were 11.2~51.7% in temp., pH, NH$_3$-N and NO$_2$-N, and 83.1~93.3% in NO-N, S.P.C. and Coliform. (2) Moutain-Site (ㄱ) The items which were over the criteria, were NO$_2$-N (p<0.05), S.P.C. (p<0.01) and Coliform (p<0.01). (ㄴ) No. of households which were over the criteria, were 33.6 ~ 75.6% in NO$_2$-N, S.P.C. and Coliform. (3) No. of households which were fit to the criteria of all items, were 9.0% in field-site and 14.1% in mountain-site. 2. Simple-piped water supply (SPWS) (1) The items which were very significantly over the critera (p<0.01), were standard plate count (S.P.C.) and Coliform. (2) The water qualities of adjacent and remote samples were better than those of source samples. (3) Residual chloride was not detected in any sample. In conclusion, rural community requires to be continually performed the policy of safety drinking water supply, and to be devised an epoch-making counterplan for the level-up of simple-piped water supply (SPWS), espically on the method of disinfection.

  • PDF

A study on pollutants removal characteristics of domestic riverbed filtration and riverbank filtration intake facilities (국내 복류수 및 강변여과수 취수시설의 오염물질 제거특성에 관한 연구)

  • Chan-woo Jeong;Sun-ick Lee;Sung-woo Shin;Chang-hyun Song;Bu-geun Jo;Jae-won Choi
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.37 no.5
    • /
    • pp.281-288
    • /
    • 2023
  • This study was performed to evaluate the pollutants removal characteristics of two types of RBFs(Riverbank filtration, Riverbed filtration) intake facilities installed in Nakdong River and in Hwang River respectively. The capacity of each RBF is 45,000 m3/d for riverbank filtration intake facility and 3,500 m3/d for riverbed filtration intake facility. According to data collected in the riverbank filtration site, removal rate of each pollutant was about BOD(Biochemical Oxygen Demand) 52%, TOC(Total Organic Carbon) 57%, SS(Suspended Solids) 44%, Total coliforms 99% correspondingly. Furthermore, Microcystins(-LR,-YR,-RR) were not found in riverbank filtered water compared to surface water in Nakdong River. DOC(Dissolved Organic Carbon) and Humics which are precursors of disinfection byproduct were also reported to be removed about 59% for DOC, 65% for Humics. Based on data analysis in riverbed filtration site in Hwang River, removal rate of each contaminant reaches to BOD 33.3%, TOC 38.5%, SS 38.9%, DOC 22.2%, UV254 21.2%, Total coliforms 73.8% respectively. Additionally, microplastics were also inspected that there was no obvious removal rate in riverbed filtered water compared to surface water in Hwang River.

A study of how Supply Chain companies correspond to water risk resulted from climate change (기후변화에 따른 기업 공급체인의 물 리스크 대응 실태 조사)

  • Park, Jiyoung;Park, Seogha;Lim, Byungsun;Kim, Chesoong
    • Journal of the Korea Safety Management & Science
    • /
    • v.17 no.1
    • /
    • pp.149-168
    • /
    • 2015
  • It is expected that the temperature in Pyeongyang will be similar to that ($16.6^{\circ}C$) in Seogwipo in the late 21st century, and most of South Korea will enter the subtropical climate due to climate change. Change in the precipitation pattern like the range of fluctuation caused by climate change will lead to expanded uncertainty in securing reliable water supply, along with a serious impact on demands for living and industrial water due to change in the volume and period of river outflow. As industrial water for production activities is estimated based on the contract quantity, it is difficult to apply rationalization of water usage and incentives in water recycling. Therefore many companies are making efforts in complying with the effluent standard while spending few resources on such rationalization and recycling. This study researched water risk management over 115 Korean companies by 28 questions in 4 categories. Through the research, this study aims to understand water risk management levels and seek response plans.

Water Vapor Supply Study for Air and Carbon dioxide (공기와 이산화탄소 가스에 수분공급을 위한 연구)

  • Lee, Taeck Hong;Park, Tae Seong;Kim, Tae Wan;Noh, Jae Hyun;Kang, Young Jin;Lee, Seung Yong
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.25 no.1
    • /
    • pp.72-78
    • /
    • 2014
  • The study has been designed to develop water vapor supply for semiconductor industry, industrial gas manufacturing, impurities analysis, and fuel cell. Water concentration in air reached $1019{\mu}mol/mol$ at dew temp ($-20^{\circ}C$) and water concentration in CO2 reached $127{\mu}mol/mol$ at dew temp ($-40^{\circ}C$. Carbon dioxide needs more wet gas than air because interaction potential of carbon dioxide shows more strong attraction than air.

Analysis of Bacterial Diversity in Water from the Han River Water Source Protection Area via a Pyrosequencing Assay (파이로시퀀싱을 이용한 한강상수원보호구역 수계 중의 세균 다양성)

  • Kim, Heejung;Kaown, Dugin;Kim, Changsoo;Lee, Siwon
    • Journal of Environmental Health Sciences
    • /
    • v.42 no.4
    • /
    • pp.274-279
    • /
    • 2016
  • Objectives: We investigated bacterial diversity in the Han River water resource protection area in order to provide basic microbiological information on the drinking water safety of the Seoul metropolitan region. Methods: Samples were collected in the spring and winter, but not during the rainy season. Pyrosequencing, gene amplification, and extraction of nucleic acids were employed in this study. Results: In total, 57 and 48 operational taxonomic units were respectively analyzed in samples collected during spring and winter. Proteobacteria were predominant in all samples. The samples contained phylogenetically diverse bacterial communities, with eleven major phyla and 36 genera. Cyanobacteria were predominant in the spring samples, but not in the winter samples. The predominant species in the samples collected during both seasons belonged to the genus Aquamicrobium and Bradyrhizobium. Moreover, no pathogenic bacteria were detected in the samples. Conclusion: Proteobacteria were predominant in the samples from the Han River water source protection area. Cyanobacteria were more predominant in the spring samples than in the winter samples, but Aquamicrobium and Bradyrhizobium were predominant in both sampling seasons.

A Study on the Safety Assessment and Damage Pattern of Water Purifier Compressors (정수기용 압축기의 안전성 평가 및 소손 패턴 분석에 관한 연구)

  • Choi, Chung-Seog
    • Journal of the Korean Society of Safety
    • /
    • v.28 no.2
    • /
    • pp.21-25
    • /
    • 2013
  • The purpose of this study is to provide basic data for the safety assessment of a water purifier when water leaks due to inappropriate maintenance and the examination of the cause of accidents related to the leak. Due to its inspection and management by non-specialists, if a leak occurs in a water purifier with the water level controller being inclined, it may result in the failure of the compressor, power supply line, PCB, etc. The analysis of the thermal diffusion pattern of water purifier compressors using a thermal image camera shows that its maximum temperature was approximately $80^{\circ}C$. In addition, its operating current was a maximum of 13 A and the system's operating current was approximately 1.7 A after the compressor was charged. It was found that the housing type power cable cover of the compressor had the effect of preventing electric shock but has poor flame resistance. Furthermore, the performance of the overload protector, PTC relays, etc., was excellent but they have potential for problems as metallic terminals were exposed, resulting in the potential of a safety related accident. The terminals and their surface damaged by the tracking showed a trace of carbonization and the resistance between terminals was measured to be approximately $8{\Omega}$. In addition, while the tracking was proceeding, the fuse and circuit breaker installed for system protection did not operate.

Estimate Analysis on the Fluoride Work Management of Water Supply Conveyance (상수도수 불화사업 운영에 관한 평가분석)

  • Kim, Kap-Jin;Lee, Yang-Kyoo
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.17 no.4
    • /
    • pp.510-518
    • /
    • 2003
  • The fluoride work management of water supply conveyance has been recommending by the WHO to prevent of tooth decay. Fluoridation of public water supplies has been practiced since 1945. The present approximately 67 countries reported community water fluoridation benefiting many cities. At our country, Fluoridation began in 1981 in Chongiu and Jinhea. In 2002, approximately 40 cities have large populations consuming fluoridated water. But Chongiu stopped fluoridation water works. Few public health measures have been accorded greater clinical and laboratory research, epidemiological study, clinical trials, and public attention than has water fluoridation. In this study, chemical analysis of Sodium Silicofluoride and Fluoride Feed Equipment analyzed. And this study proposed to Fluoride concentration experimental (lab. and field exp.), economics analysis, prevention effect. This study can be decided on the concentration of fluoride injection in Water Fluoridation. Hereafter, this study will be useful in safety and economics of Water Fluoridation in the future.

Tracer Experiment and Computational Fluid Dynamics Analysis for the Drainage Efficiency of a Reservoir (배수지의 배수효율분석을 위한 추적자실험 및 전산유체해석)

  • Cho, Jung-Yeon;Go, Sun-Ho;Kwac, Lee-Ku
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.16 no.2
    • /
    • pp.22-27
    • /
    • 2017
  • During the water treatment process for household water supply, a reservoir is the last place the water is stored before being supplied to users, and the duration of the water's stay is an important factor that affects its safety. This may cause the concentration of the residual chlorine disinfectant to increase and thus lower the water's quality. The concentration and discharge efficiency of residual chlorine must be verified and managed, because these are key factors that affect the reservoir's performance. Because the actual verification test for analyzing the efficiency of a reservoir and the disinfectant's dilution capacity is difficult, simulations are generally conducted using the computational fluid analysis method. However, the simulation results require validation with experiments. The error and drainage efficiency were analyzed in this study by comparing and analyzing the actual tracer test and simulation so that the actual test for a hexagonal drainage can be replaced by the computational fluid analysis method. Based on the results of the efficiency analysis, the hexagonal reservoir was found to be appropriate, and the simulation's reliability was verified with a tracer test.

Demonstration study on Desalination System using Solar energy (태양에너지 해수담수화시스템 실증)

  • Kim, Jeong-Bae;Joo, Hong-Jin;Yoon, Eung-Sang;Joo, Moon-Chang;Kwak, Hee-Youl
    • Journal of the Korean Solar Energy Society
    • /
    • v.27 no.4
    • /
    • pp.27-33
    • /
    • 2007
  • In this research, to develop the practical application system of fresh water generation system with plate-type fresh water generator using low pressure evaporation method is the main object, and to do that, this study used the evacuated solar collector with operating range of about $50-85^{\circ}C$ as thermal energy source and solar photovoltaic as electric energy source. To achieve that object, this study set up the demo-plant, then estimated and analyzed the usefulness, the safety, and the reliability through pre-tests during short time ahead of the long-time operation. This study showed that the pumps, which are including sea water supply, ejector, hot water supply, and fresh water pumps, were operated one after another. And, the fresh water yield was closely related with the solar irradiance and lower supply temperature of hot water was revealed more reasonable for the solar energy desalination system. That is due to the insufficient area than the solar collector area being required that was estimated through the performance tests of the fresh water generator.

Recent instrumentation system safety instrumentation and man-machine interface

  • Satake, Noboru
    • 전기의세계
    • /
    • v.25 no.6
    • /
    • pp.8-13
    • /
    • 1976
  • The industrial processes have become complicated on a large scale bacause of improvement of productivity, research of efficiency, and shortage of locations to be suited for foundation of factories. Consequently, the instrumentation and control systems for operating these industrial processes have also been highly improved with the development of mass information means. In order to operate these large-sized and complicated industrial processes safely, the man-machine interface for correspondence between man and machines and the instrumentation system regarding process fault processing are playing an important role increasingly. This paper describes recent instrumentation system in the water purifying plant as an example of these industrial processes, and covers both man-machine interface and process fault processing. The annual water supply quantity and diffusion were 2, 000, 000, 000m$^{3}$ and 25.0% in 1950 inJapan, but they amounted to 12, 000, 000, 000m$^{3}$ and 86.7% in 1974, respectively. The demands of water will increase incessantly, while it becomes gradually difficult to secure water sources. Accordingly, local self-governing bodies such as municipal cooperation, towns, and villages often construct a large-scale water purifying plant at one place in common, as required, without constructing respective plants independently. It is an absolute requirement for the water purifying plant to avoid stopping water supply to fullfil its social responsibility from the viewpoints of its public utility enterprise, and also it has gradually become difficult to secure skilled operators enough to cover such water purifying plants that are additionally provided in various districts. Thus, the importance of the man-machine interface for assuring safety operation of the water purifying plant irrespective of unskillfulness of operators as well as the instrumentation system regarding process fault processing, or, safety instrumentation, is more and more increasing as the water purifying plants are on a large scale.

  • PDF