• 제목/요약/키워드: water sources

검색결과 2,201건 처리시간 0.028초

OECD 인 수지 산정법의 지역단위 적용 연구: 유출입 자료 출처 비교 (Regional Application of the OECD Phosphorus Budget: Comparison of the Input-Output Data Sources)

  • 임도영;류홍덕;정유진;김용석
    • 한국환경과학회지
    • /
    • 제26권11호
    • /
    • pp.1255-1266
    • /
    • 2017
  • Phosphorus (P) is an essential and major nutrient for both plants and animals. However, anthropogenic P in the environment may cause severe problems such as the deterioration of water quality. Therefore, it is essential for the Korean government to manage P in the agricultural sector. The annual P budget for Korea was 46 kg P ha-1 in 2013, placing Korea in second among Organisation for Economic Co-operation and Development (OECD) countries. P surplus and deficiency in agricultural lands can be estimated according to the P budget, which is one of the OECD agri-environment indicators. In the P budget, it is important to ensure consistency in the input-output data sources, in order to apply national and regional policies for the environmentally sound management of agricultural P. This study examines the impacts on the input-output data sources in the regional P budget in Korea. P budgets were between 99-145 kg-P/ha, depending on different data sources. We suggest two recommended data combinations (DC 1 and DC 2) for reliability of the data. P budgets calculated using DC 1 and DC 2 were 128 kg-P/ha and 97 kg-P/ha, respectively. According to the results, one of the core factors affecting P budgets was crop production. In this study, DC 2 was recommended rather than DC 1 in order to consider the cultivated areas for various crops. It is also necessary to analyze the sensitivity of the coefficients used in P budget in the future.

유역모형을 이용한 낙동강 유역에서의 비점오염원 정량화 (Non-point Source Quantification Analysis Using SWAT in Nakdong River Watershed)

  • 황보현;김동일;윤영삼;한건연
    • 한국수자원학회논문집
    • /
    • 제43권4호
    • /
    • pp.367-381
    • /
    • 2010
  • 최근 들어 도시화와 이상기후의 영향으로 유역에서의 유출특성과 오염물질 발생특성도 변화하고 있고 이에 따라 정교한 유역 수질분석이 요구되고 있다. 유역의 비점오염원 관리를 위하여 충분조건을 갖추어야 할 정량분석이 선행되어야 하나 점오염원 관리와 달리 자연 내의 복잡한 현상을 반영하여야 하기 때문에 비점오염원의 정량화 해석에 어려움을 겪어왔다. 강우 및 유출량 관계와 덧붙여 오염물질이 하천수질에 영향을 미치기까지 도달시간 해석 및 점오염원과 비점 오염원의 분리가 용이하지 않기 때문이다. 본 연구의 목적은 토양도, 토지이용도 자료 등을 이용하여 유역의 비점오염원을 정량화하고, 비점오염원 관리를 위한 기반자료로 활용하기 위함에 있다. 이를 위하여 유역모형 SWAT (Soil and Water Assessment Tools) 모형을 이용하여 비점오염원 정량화를 수행하였다. 유역의 비점오염원 비율은 국립환경과학원에서 조사된 비점오염원 비율인 22~37%정도와 비교적 잘 일치하는 것으로 나타나고 있다.

한강수계 굴포천과 안양천에서 안정동위원소와 수질 특성을 이용한 입자성 물질의 기원 추적 (Source Tracking of Particular Matters using Stable Isotope Analysis and Water Quality Characteristics in Gulpo and Anyang Stream, Han-River)

  • 홍정기;임종권;손주연;노혜란;유순주;이보미
    • 한국물환경학회지
    • /
    • 제36권2호
    • /
    • pp.116-124
    • /
    • 2020
  • This study aims to identify the characteristics of organic matter and pollutant sources using water quality and stable isotope ratios (δ15N, δ13C) of the two inflow tributaries (Gulpo (GP) and Anyang (AY) streams). Water samples were analyzed in June and September 2018, and the results showed that the concentrations of nutrients, such as TN and NO3-N, were increased at GP4, which is located at the downstream of sewage treatment facilities(STFs). TOC and TN ratios showed a strong positive correlation (R2 = 0.77, p<0.01) at all points except for GP4. The results of GP's stable isotope ratio analysis do not appear to be a constant cluster compared to AY because GPs with large amounts of pollutants from the industry (metal processing companies, etc.) have less tributary, shorter waterway and significantly different external sources. This could be attributed to different sources of external inflow despite its smaller number of tributaries and shorter waterways than AY. In the first half of the year, the δ155N of GP4 was affected by discharge of STFs, while AY3 seemed to have an influence of tributary than the discharge of STFs. Consequently, using water quality, stable isotope ratio and C/N, the sources of contamination in two streams with different contaminants were identified and origin was estimated.

Candidates for the young stellar outflows: Water and Methanol masers from young stellar objects

  • 임왕기;여아란;김기태;변도영
    • 천문학회보
    • /
    • 제37권2호
    • /
    • pp.236.1-236.1
    • /
    • 2012
  • We conducted simultaneous 22GHz water maser and 44GHz class I methanol maser surveys of newly-identified 282 H2 emission features from the $2.122{\mu}m$ H2 narrowband image survey in the Galactic plane (UWISH2 project) using Korea VLBI Network (KVN) 21-m radio telescopes. We detected 16 and 13 new water and methanol maser sources, respectively. This result indicates that at least ~5% of the H2 emission features originate from young stellar objects (YSOs) that are in the right physical condition to produce the water and methanol masers. The masers are closely related to the current outflow activities in the Galactic plane. The power sources of these 23 diffused/collimated H2 emission features (six sources are detected for both masers) are likely to be intermediate-to high-mass YSOs, based on a comparison with the maser luminosities of other well-studied YSOs. Both maser velocities are mostly close to their own systemic velocities within 5 km/s, even though water masers generally show larger variabilities in the line intensities, velocities, and shapes than methanol masers. We also discovered three new water maser sources with high-velocity components: ~25 km/s red-shifted CMHO019, ~50 km/s blue-shifted CMHO132, and ~120 km/s blue-shifted CMHO182. In particular, we propose that the dominant blue-shifted water maser of CHMO182 could become a unique laboratory for the study of high-mass stellar jet and their accelerations.

  • PDF

Processes of Outflow of the Boiling Steam-Water Mixture in the Widening Part of Hydro-Steam Turbine Nozzles

  • Leonid, Serejkin;Boris, Shifrin;Victor, Perov;Alexandr, Goldin
    • International Journal of Computer Science & Network Security
    • /
    • 제22권12호
    • /
    • pp.178-184
    • /
    • 2022
  • Renewable energy sources based on solar radiation, wind energy, geothermal energy, and biomass energy have now reached the level of industrial application. A new way to generate electricity using low-potential heat is to install a hydro-steam turbine. In hydro-steam turbines, hot water is supplied directly to turbine rotor nozzles without prior separation into steam and water in separators, which significantly increases the efficiency of hot water energy use. Such turbines are suggested to be used as autonomous energy sources in geothermal heating systems, heating water boilers and cooling systems of chemical reactors, metallurgical furnaces, etc. The authors conclude that the installation of hydro-steam turbines in heating plants and process boiler plants can also be effective if the used exhaust steam-water mixture at the turbine outlet is used to heat the network water or as return water.

안양천 유역의 강우시 비점오염원에 따른 유출부하특성에 관한 연구 (Study on Runoff Characteristics of Nonpoint Sources during Rainfall in Anyangchun Watershed)

  • 황병기;유세진;차영기
    • 환경영향평가
    • /
    • 제10권3호
    • /
    • pp.223-234
    • /
    • 2001
  • In this study, we conducted a survey to examine the runoff characteristics of nonpoint sources, which wash off pollutants from the surface of basin during rainfall and affect water pollution of streams. An Anyangchun basin in the region Ewiwang City was selected as a study site. The basin divided into several subbasins such as Wanggokchun, Ojeonchun, and Anyangchun based on the tributaries, which confluence to the main stream of Anyangchun. Four times of field examination had been carried out between July and August of 2000, and water quality data collected from the surveys had been analysed. The survey includes in-situ flow, DO and PH measurements in the outlet of catchment. Laboratory analysis includes BOD, TN, TP. From the result, pollutant by runoff of nonpoint sources were washed out along with stormwater in the beginning of rainfall, and flowed into streams resulted in stream pollution. In case of BOD, the load from Ojeonchun catchment, most of which included urban areas, took up 50% of the total load from the entire watershed. Thus, by the results, it is clear that runoff load by urban nonpoint sources plays an important role in the control and management of nonpoint sources for the watershed.

  • PDF

전북 지역 일부 수원지의 물에서 불소, 칼슘 및 마그네슘 함량에 관한 조사 연구 (A Survey on the Contents of Fluoride, Calcium, and Magnesium of Reservoir Water on a Stream in the Jeon-buk Area of Korea)

  • 이인규;김종규
    • 한국환경보건학회지
    • /
    • 제29권2호
    • /
    • pp.38-44
    • /
    • 2003
  • This study was performed to investigate the levels of fluoride (F), calcium (Ca), and magnesium (Mg) in water samples taken from five reservoirs or direct sources on a stream used for agricultural or domestic water in the Iksan and Wanjoo areas, Jeon-buk, Korea, and to find a possible link between Ca or Mg and fluoride in water sources in theses areas. The samples were collected by the recommendation methods of the World Health Organization and analyzed by the recommendations of the Japanese Standard Methods. Statistical analyses were performed by the analysis of variance and correlation analysis. The F levels in water samples wire 0.80~2.53 ppm. In four sampling sites the water fluoride levels exceeded 1 ppm. which if the recommended level for fluorosis/caries control. The Ca levels in water samples were 6.82~12.98 ppm, and the Mg levels were 0.30~1.97 ppm, which are lower compared with the natural levels of water sources previously reported by other investigators. This study showed a positive correlation between Ca and Mg (r= 0.8779. p<0.01) and a negative correlation between F and Ca (r=-0.6974, p<0.05) and also between F and Mg (r=-0.5581) in the water samples. However, the study did not find remarkable relationships in fluoride levels between sampling sites. These results support the fact that there were epidemics of dental fluorosis in this area. The lack of significant positive correlations in fluoride levels between sampling sites suggests that there may be some pathways for the transfer of the metal to the water through other environmental media besides the water course. Long-term epidemiological studies are needed on the relationship between high F together with low Ca and Mg levels in the water, and total human health in this community. There should alto be a long-term monitoring of the water quality in this area.

SWMM을 이용한 비점오염원 관리 저류지의 오리피스 설계기법 연구 (Detention Orifice Design for Non-point Source Management Using SWMM)

  • 조선주;김상단
    • 한국물환경학회지
    • /
    • 제28권5호
    • /
    • pp.686-692
    • /
    • 2012
  • This study illustrates how to design and evaluate a non-point sources management detention pond using SWMM. In particular, special attention is given to the orifice design. In SWMM, orifice properties that need to be defined include its height above the bottom of the storage unit, its type, its geometry and its hydraulic properties. Among the various characteristics of orifice, the orifice hole size which is closely related to hydraulic retention time is focused in this study. Sensitivity analysis of orifice size in annual non-point sources reduction efficiency is carried out. In addition, a methodology which can be used to design a virtual junction in SWMM has been proposed to quantify water quality improvement triggered by the detention pond installation. As a result, it is recommended that a detention outlet should be designed to be about 2 to 3 days of hydraulic retention time.

식이 단백질의 종류와 수준이 연령이 다른 흰쥐에서 뇨 Ca 배설 및 뼈에 미치는 영향 (The Effect of Dietary Protein on Bone Metabolism in the Rats of Different Ages)

  • 김혜영
    • Journal of Nutrition and Health
    • /
    • 제19권1호
    • /
    • pp.66-73
    • /
    • 1986
  • This study was undertaken to investigate the effects of age and of the dietary protein sources & levels on urinary calcium excretion and bone metabolism in the rats. Two experiments were conducted . In experiment U, 6& 20 weeks old rats were fed 8 & 36%, casein & ffish protein diet for 5 weeks . In experiment II, 16& 52 weeks old rats were fed 40 % protein diets, protein sources were casein, fish and gluten. High-protein diet group excreted more caldium in urine than low-protein group. Urinary calcium excretion was affected by the sources of protein ; gluten group excreted more Ca, followed by fish & casein group. Total bone Ca & Ca proportion in ash were higher in 20 weeks old rats than 6 weeks old rats, but 16 & 52 weeks old rats showed no differences. bone composition showed that water proportion was high and ash proportion was low in 6 weeks old rats than in 20 weeks old rats. However, these tendencies were not observed between 16 weeks and 52 weeks old rats. And bone composition was affected by protein sources ; higher ash proportions were noted in one order of casein, fish, and gluten water proportion were lower in one same order.

  • PDF

A Study on the Microbiological Quality of Drinking Water and Changes During Storage

  • Kim, Jong-Gyu
    • 한국환경보건학회지
    • /
    • 제33권6호
    • /
    • pp.517-521
    • /
    • 2007
  • To assess possible risks from the consumption of drinking water from various sources, a survey of the microbiological quality of tap water, commercial bottled drinking water which is exploited from natural mineral water, and natural spring water was conducted. A total of 4 different brands of commercial bottled drinking water, and 4 types of spring water from different sources, and tap water from 4 private houses were tested for four index microorganisms, and the microbial quality changes of the water during the storage at room temperature or refrigerated temperature for 7 days. Aerobic plate counts of all of the initial water samples were still within 100 CFU/ml (drinking water standard of Korea). Total coliforms, fecal coliforms, and E. coli were not detected in all of the water samples at initial. However, aerobic plate counts of three types of spring water and three types of bottled drinking water stored at room temperature showed higher levels than the standards in 5 days. Total coliforms were detected in three types of spring water after one day's storage at room temperature, and in one type of bottled drinking water after 5 days' storage. These results indicate that some of the spring water surveyed are not safe to drink, and the spring water and bottled drinking water after opening the lid should not be stored at room temperature, if they are used for drinking.