• Title/Summary/Keyword: water regulations

Search Result 396, Processing Time 0.035 seconds

Performance evaluation of nitrate removal in high TDS wet scrubber wastewater by ion exchange resin with dissolved air flotation (DAF) process

  • Kim, Bongchul;Yeo, Inseol;Park, Chan-gyu
    • Membrane and Water Treatment
    • /
    • v.13 no.1
    • /
    • pp.1-6
    • /
    • 2022
  • The regulations of the International Maritime Organization (IMO) have been steadily strengthened in ship emissions. Accordingly, there is a growing need for development of related technologies for the removal of contaminants that may occur during the treatment of SOx and NOx using a wet scrubber. However, this system also leads to wastewater production when the exhaust gas is scrubbed. In this research, we evaluated the performance of an ion selective resin process in accordance with scrubber wastewater discharge regulations, specifically nitrate discharge, by the IMO. Accelerated real and synthetic wastewater of wet scrubbers, contained high amounts of TDS with high nitrate, is used as feed water in lab scale systems. Furthermore, a pilot scale dissolved air flotation (DAF) using microbubble generator with ion exchange resin process was combined and developed in order to apply for the treatment of wet scrubber wastewater. The results of the present study revealed that operating conditions, such as resin property, bed volume (BV), and inlet wastewater flow rate, significantly affect the removal performance. Finally, through a pilot test, DAF with ion exchange resin process showed a noticeable improvement of the nitrate removal rate compared to the single DAF process.

Development Strategy of Clean Hydrogen Production by Renewable Energy-based Water Electrolysis in Korea (국내 재생에너지 연계 수전해 청정수소 생산 발전 전략: 국내외 관련 연구의 비교, 분석을 중심으로)

  • YOUNG YIEL CHOI;IN SUNG JUNG;TAE JIN KIM
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.34 no.5
    • /
    • pp.389-397
    • /
    • 2023
  • This study compares domestic and foreign research on renewable energy-based water electrolysis clean hydrogen. Domestic studies from 2010 to 2023 focused on technological efficiency, energy efficiency, and system efficiency, with few analyzing infrastructure and technology trends. Overseas research initially focused on technological efficiency and stability, but has since shifted to economic and environmental impact, policy effectiveness, industry-university-research cooperation, and sustainability. To improve water electrolysis technology production, this study suggests prioritizing technology stability over efficiency, resolving government regulations and resident acceptance issues, promoting industry-university-institute cooperation for rapid commercialization of research results, and developing a strategy for sustainable development of renewable energy-based water electrolysis technology.

Analysis on the actual condition of consciousness for related regulations with revised Water Leisure Safety Regulation (수상레저안전법의 개정에 따른 관련규제에 관한 의식실태분석)

  • Kim Jun-Hoon;Gug Seung-Gi
    • Journal of Navigation and Port Research
    • /
    • v.29 no.10 s.106
    • /
    • pp.891-896
    • /
    • 2005
  • Changes such as expanding nationwide road networks, 5-day work system and income increases triggered high interest in water leisure and an increase in water sports population. And safety regulations have been under discussion as a possible way to prevent the water leisure related accidents. Water Leisure Safety Regulation was enacted in 1999 and fully revised in 2005. Therefore, it is necessary to examine the current state cf water leisure activities and how the water leisure safety regulations are perceived. For this purpose, a survey of water leisure people was conducted on the revised safety regulation and relevance and correlation between variables were examined using Frequency analysis and Crosstabs. The results showed that more than $60\%$ of the people surveyed acknowledge the necessity of registration, safety instruction, insurance, and safety inspection. It was also found that the people who are highly dissatisfied with the safety of water leisure apparatus and acknowledge the necessity of insurance showed strong opinion of the necessity of legal controls on water leisure activities.

Treatment of Highly Organic, Brackish Surface Water by Integrated Membrane Systems

  • Lee, Jin-Woo;James Taylor;Seungkwan Hong
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 2004.05a
    • /
    • pp.25-28
    • /
    • 2004
  • In recent years, membranes have become fully or partially integrated into all facilities that produce drinking water since membrane processes can resolve technically complex and, at times, conflicting requirements related to compliance with multi-contaminant regulations. However, NF or RO technologies are hydraulically limited by the feed water quality that causes the fouling in a membrane system. In particular, NF or RO systems involved in surface water treatment generally require extensive pretreatment for controlling membrane fouling.(omitted)

  • PDF

Priority for the Improvement on Natural Conservation Zone system (자연보전권역 관련 제도개선 우선순위에 관한 연구)

  • Lee, Yun Sang;Ahn, Hyeon;Lee, Mi Hong
    • Land and Housing Review
    • /
    • v.10 no.2
    • /
    • pp.1-13
    • /
    • 2019
  • This study suggests that the system improvement priority of the Natural Conservation Zone of the Metropolitan Area Maintenance Planning Law, which was enacted for about 37 years. First of all, through the precedent research and the consultation meeting, the improvement plan was divided into the short term and the mid(or long) term. Important findings and implications are as follows. The short-term priority results were 'Improve water quality regulation', 'Strengthen individual location regulations of factories and induce multi-use plan position', and 'Improvement of waterfront area regulation', which were both critical and urgent. The mid-term(or Long-term) priority results were 'To integrate development and environmental duplication regulations', 'Abolition and unification of environmental laws', and 'Adjustment and resetting of natural conservation areas', which were both critical and urgent. On the other hand, 76.4% of the residents and 64.5% of the experts are concerned about the necessity of improvement of the Natural Conservation Zone system. Both residents and experts seem to be aware of the necessity. Opinions about Improvement and mitigation of regulations on Natural Conservation Zone that were constantly raised. In the past, there was a temporary and fragmented institutional mitigation of the government. However, with the rapid development of eco-friendly technologies since 2010, Our Country Conditions is in a transition period. This study has significant implications for the improvement and mitigation of metropolitan area regulations.

Evaluation for Contents of Contaminants and Leaching Characteristics of Bottom Ash (바텀애쉬의 유해물질 함량 측정 및 용출특성 평가연구)

  • Koh, Taehoon;Lee, Sungjin;Shin, Minho;Kim, Byongsuk;Lee, Jeakeun;Lee, Taeyoon
    • Journal of the Korean GEO-environmental Society
    • /
    • v.11 no.6
    • /
    • pp.77-83
    • /
    • 2010
  • In this study, we tried to determine any detrimental effects on water quality when bottom ash obtained from a coal-fired power plant intended to be used as a fill material in construction sites. Physical-chemical properties of bottom ash were determined using proximate analysis, elemental analysis, XRD, and XRF. Classification of bottom ash as a waste material and soil contamination due to the use of bottom ash were performed by Korea waste standard leaching test and soil toxicity test, respectively. Results of leaching tests were compared to the regulations for water quality and groundwater quality and no harmful effects on water quality were found. Most of heavy metals in leachate were below detection limits but trace amount of $Cr^{6+}$ was found. However, concentration of $Cr^{6+}$ was below the regulation criteria. Column leaching tests indicated that concentrations of Pb and Zn were slightly higher than regulations but below regulations within 1 PVE, but concentrations of sulfate were 10 times higher than regulation and thus, the required time to reach regulation was almost 8 PVE.

A Study on Reliability Improvement of Domestic Ground Source Heat Pump Units by Analyzing the Certification System (국내 지열원 히트펌프 유닛의 인증제도 분석을 통한 신뢰성 향상 방안 연구)

  • Chan Woo Yang;Hee Jeong Kang;Sewang Oh;Ubin Do;Kwang Ho Lee;Jong Woong Choi;Yong Cho;Jong Min Choi
    • New & Renewable Energy
    • /
    • v.19 no.4
    • /
    • pp.72-83
    • /
    • 2023
  • Only ground source heat pump units certified according to the regulations in Korea can be adopted in ground source heat pump systems. In this study, domestic and international standards and regulations for ground source heat pump units were investigated. Unlike ISO 13256-1~2, which is the international standard, KS B 8292~8294 for ground source heat pump unit only included rated test conditions. Therefore, it is necessary to supplement various test conditions to the KS B series, because its performance data, which is required to calculate the system's design capacity, is dependent on the change in entering water temperature. The difference between the coefficient of performance of the certified ground source heat pump units and the certified criteria changed significantly according to the operating mode, heat source, and load type, because the criteria increased by about 5% for all. Thus, it is highly suggested that the certification standards be revised while considering the product performance level and various conditions.

A Survey of Sanitation of the Water Supply System in Schools (학교 급수위생에 관한 연구)

  • 권은미
    • Hwankyungkyoyuk
    • /
    • v.3 no.1
    • /
    • pp.125-129
    • /
    • 1992
  • The purpose of this study was to investigate the condition of school water supply systems and to provide a way to supply safe and sanitary water in schools. In 1991 present, 56.9% of schools in the whole nation are provided with water supply system. And in urban schools, the percentage of small water supply system was larger than that in city. In the survey on water quality of supply water in Seoul city, the items violating the water quality standard were total bacteria, Zinc and Manganse. For supply the safe drinking water changing the old water mains and executing periodical water quality surveys are needed in addition regulations on school supply water and sanitation are also necessary to the drinking water management in schools.

  • PDF

Reconstruction of North Korean Water Infrastructure: Present Status and Future Challenge (북한 상하수도 인프라 재구축: 현황과 전망)

  • Yun, Zuwhan
    • Journal of Korean Society on Water Environment
    • /
    • v.24 no.6
    • /
    • pp.641-650
    • /
    • 2008
  • This paper reviews the infrastructure of the water supply and sewerage system in North Korea. North Korean has similar legal protection to preserve water environment that can be seen in Republic of Korea, but North Korean regulations seemed lack of detailed measures. The critical pollution problems of rivers and lakes in the northern part of peninsula is mainly due to the lack of sewage collection system and poor treatment works. It has been estimated that less than 20% of sewers are connected to the wastewater treatment plants. Although the availability of water resources seemed sufficient, North Koreans suffer the lack of the drinking water supply which needs an urgent attention. Based on the analysis, it has been suggested that the reconstruction of North Korean water and sewage infrastructure needs at least 17.5 trillion Korean Won.