• Title/Summary/Keyword: water purifier

Search Result 89, Processing Time 0.023 seconds

An Accelerated Life Test of Booster Pump for Water Purifier (정수기용 부스터펌프의 가속수명시험)

  • Moon, Ji-Seob;Jeong, Seon-Yong;Kim, Myung-Soo
    • Journal of Applied Reliability
    • /
    • v.11 no.3
    • /
    • pp.281-291
    • /
    • 2011
  • This paper presents an accelerated life test of booster pump for home water purifier. The failure analysis shows that decreased flux due to the plastic deformation of bypass spring adjusting pressure is the predominant failure mechanism. An accelerated life test is designed and implemented to estimate the lifetime of the booster pump. Temperature, water pressure and voltage are selected as accelerating variables through the technical review about failure mechanism. It is assumed that the lifetimes of booster pumps follow lognormal distribution and the combination model of temperature and non-thermal stresses holds. The life-stress relationship, acceleration factor, and $B_{10}$ life at design condition are estimated by analyzing the accelerated life test data.

A Study on the Treatment Performance of Coalescer to Treat Exhaust Gas Cleaning Water (콜레이서를 이용한 배기가스 세정수 처리 성능에 관한 연구)

  • Ha, Shin-Young;Kim, In-Soo
    • Journal of Navigation and Port Research
    • /
    • v.40 no.1
    • /
    • pp.1-6
    • /
    • 2016
  • This study was conducted on a circulation system which can recycle waste water from EGCS(Exhaust Gas Cleaning System) using a wet scrubber that is used to treat air pollutants from ships. Though we developed a water treatment system that could remove effectively particulate matters and dispersed oil included in cleaning water for Ship Exhaust Gas Recycle System(DePM & DeSOx), we found that it is difficult to treat minutely dispersed oil only by means of centrifugal-typed purifier. Therefore, to this system, we applied a coalescer that coalesces emulsified minute oil particles in the 2nd phase of dispersion state after being filtered through the centrifugal-typed purifier. After we treated cleaning water drained out of Ship Exhaust Gas Recycle System(DePM & DeSOx) by using both purifier and coalescer, we found that particulate matters and dispersed oil were removed more than 55% and 99%, respectively, in comparison with those contained in cleaning water influent. Putting the results together, we conclude that the treated cleaning water can be recycled as normal cleaning water if this cleaning water treatment system is employed by the wet cleaning tower system for the reduction of air pollutants from ships.

An Accelerated Life Test of Thermoelectric Module for Water Purifier (정수기 적용 열전모듈의 가속수명시험)

  • Moon, Ji Seob;Lee, Sung Min;Jeong, Seon Yong;Kim, Myung Soo
    • Journal of Applied Reliability
    • /
    • v.14 no.1
    • /
    • pp.21-28
    • /
    • 2014
  • This paper presents an accelerated life test to estimate the lifetime of thermoelectric module for home water purifier. Clamping force and thermal cycle are selected as accelerating variables through the technical review about failure mechanism. It is assumed that its lifetime follows weibull distribution. The relationship, acceleration factor, and BP life at design condition are estimated by analyzing the accelerated life test data.

Development of Remote Monitoring System for groundwater purifier apparatus for community wells (마을 공동 우물용 지하수 정수 장치의 원격 모니터링 시스템 개발)

  • Kim, Dong-Jin;park, Sang-heup;Lee, Hong-Sup
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.11
    • /
    • pp.224-231
    • /
    • 2019
  • Recently, the pollution of groundwater has become serious. In particular, the contamination of groundwater near livestock farms is becoming increasingly severe and it is difficult to drink with drinking water. In this paper, a groundwater purifier apparatus that can be installed in a community well was designed. The designed groundwater purifier apparatus enables a RO membrane filter and UV sterilization to remove pollutants, such as heavy metals, bacteria, and organic compounds. In addition, electrical conductivity, pressure, and flow sensors were added for remote monitoring. Remote monitoring of the system can determine the level of fouling and contamination of RO membrane filters through pressure and flow sensor data, and can record changes in the contamination and condition of groundwater through the electrical conductivity of the feed water. The designed groundwater purifier apparatus was installed at a farmhouse and remote monitoring. The result after 15 days of operating a groundwater purifier apparatus and analyzing the monitoring data revealed an average permeate water flow rate of 2.67L/min and an average water pressure of 7.09kgf/㎠, indicating that the RO Membrane filtered without fouling and clogging. The average electrical conductivity was 796.6 S/㎠ of the feed water and 55.6 S/㎠ of permeate water, which is similar to that of general tap water. Through this, it was confirmed that no pollutant occurred in the surroundings. Therefore, the designed groundwater purifier apparatus can confirm the replacement time of the RO membrane filter in advance through remote monitoring, and check the pollution state of the groundwater.

Development and Performance of Water Purifier with the Auto-Disinfected on a simple Drinking Water (간이상수도 자동소독 정수기의 개발 및 성능에 관한 연구)

  • Cho, Byeung-Rak;Lee, Bae-Bok;Choi, Myeung-Bu
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.16 no.2
    • /
    • pp.41-46
    • /
    • 2013
  • On the purpose of helping the inhabitants living in farming, fishing villages, and islands for more safe and hygienic water from simple waterworks, experimental investigations were performed concerning the development of a water purifier with silver nanomaterial packed, having a function of the auto-disinfection. The results show as follows through such filteration and auto-disinfection processes. It is possible to get hygienic and safe water, for example, more than 95% of general bacteria, total coliforms, and fecal coliforms were removed. It is also possible to get good-quality water, for 49.4% of spent potassium permanganate and 85% and 63% of turbidity and conductivity were removed respectively. It is a very effective equipment, for 100% cost reduction of used chemicals was achieved by no-chemical disinfection process and THM was not generated.

Current Condition and Prospect of On-Site Domestic Wastewater Treatment Technologies (합병정화조 기술현황 및 전망)

  • 임연택
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1998.06a
    • /
    • pp.95-112
    • /
    • 1998
  • Water quality in the public water course has been polluted more seriously than ever before due to the increase of the number and aremount of pollution sources such as domestic and industrial wastewater. For water quality conservation, the Korean government has been trying to construct sewage treatment facilities continually, of which treatment capacity reached to 11,452,400m$^{3}$/day in 1996. Night soil treatment facilites of m nationwide have the treatment capacity of 24,038m$^{3}$/day. But water quality has not been improved because the sewer systems were insufficient and the treatment efficiencies of sewage were not high, enough. For renovation of water quality, miscellaneous domestic wastewater must be treated because 27g BOD/day out of total 40g BOD/person-day come from miscellaneous wastewater, comparing to 13g BOD/day from night soil. However, sole treatment purifier treat only night soil from the flushing toilet. Therefore, it may be desirable to treat the miscellaneous domestic wastewater and the night soil from flushing toilet together by joint treatment purifier system as on-site domestic wastewater treatment technology. In Korea, the joint treatment purifier system, introduced in 1997, have the benefit as follows; i) good water poiluion control effect, ii ) good effect on river water flow, iii) water pollution control with sewage treatment facility, and iv) rapid pollution control effect, etc. In order to achieve a good effect as stated before, i ) strengthening effluent guideline including BOD, nitrogen and phosphorus, ii ) specializing operation to maintain high performance, and iii) supporting its construction and maintenance costs by the governmental level may be necessary: In addition, automation system of joint treatment purifier, technology for its package and compactness, and a new bio-media bio-filter with higher capacity should be further developed in agreement with a more stringent effluent guideline.

  • PDF

On decrease program of Radioactive Wastewater and Sewages in High Dose Radioiodine Therapy Ward (고용량 방사성옥소 치료병실의 오.폐수 저감화를 위한 연구)

  • Ryu, Jae-Kwang;Jung, Woo-Young;Shin, Sang-Ki;Cho, Shee-Man
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.1
    • /
    • pp.19-26
    • /
    • 2008
  • Purpose: In general, We discharged radioactive wastewater and sewages less than $8.1{\times}10^{-13}$ Ci/ml in a exclusive water-purifier tank. Our hospital operating three exclusive water-purifier tank for radioactive wastewater and sewages of 60 tons capacity respectively. In order to meet the criteria it need a enough decay more than 125 days per each exclusive tank. However, recently we fell into the serious situation that decay period was decreased remarkably, owing to the wastewater amount increased rapidly by enlarge the therapy ward. For that reason, in this article, I'd like to say the way that reducing of radioactive wastewater and sewages rationally. Materials and Methods: From January, 2006 to October, four hundred and two cases were analyzed. They were all hospitalized during 3 days and 2 nights. We calculated the average amount of water used (include toilet water used, shower water used, washstand water used, $\cdots$), each exclusive water-purifier tank's decay period, as well as try to search the increased factors about water-purifier tank inflow flux by re-analysis of the procedure of radioisotope therapy step by step. Results: We could increase each exclusive water-purifier tank's decay period from 84 days to 130 days through the improvement about following cause: (1) Improvement of conventional toilet stool for excessive water waste $\rightarrow$ Replacement of water saving style toilet stool (2) Prevention of unnecessary shower and wash (3) Stop the diuretics taking during hospitalization (4) Analysis of relationship between water intakes and residual dose of body (5) Education about outside toilet utilization before the administration (6) Changed each water-purifier tank's maximum level from85% to 90% Conclusion: The originality of our efforts are not only software but hardware performance improvements. Incidentally the side of software's are change of therapy procedures and protocols, the side of hardware's are replacement of water saving style toilet stool and change of each water-purifier tank's maximum level. Thus even if a long lapse of time, problem such as return to the former conditions may not happen. Besides, We expect that our trials become a new reasonable model in similar situation.

  • PDF

Adsorption Characteristics of Granular Activated Carbon Filter Used for Drinking Water Purifier (정수기용 입상활성탄소 필터의 흡착특성에 관한 고찰)

  • Baek, Young-Man;Park, Je-Chul;Kim, Hyung-Jin
    • Journal of Environmental Science International
    • /
    • v.17 no.8
    • /
    • pp.899-905
    • /
    • 2008
  • Quality test for activated carbon(AC) filter used for drinking water purifier is now an obligatory test and the standard material for valid purifying amount in water purifier performance test has been changed from residual chlorine to chloroform according to the notice of Ministry of Environment in 2006. Therefore, this study aimed to compare the ingredients of AC filters by confirming chloroform removal rate of AC filter and conducting 4 adsorption tests (Iodine, methylene blue decolorization, phenol value, ADS value) for AC filters provided by manufacturers. With water pressure of $1kgf/cm^2$, 1,500 liters of prepared inflow went through to check chloroform removal rate. As a result, product with removal rate of below 60% from all products. On the other hand, 4 adsorption tests were conducted for filters in the market and filters from manufacturers. None of the products satisfied all 4 tests. In particular, they showed great shortage to the standard in phenol value and ADS value test. However, manufacturers' filter showed much better performance than filters in the market. Also, the result of valid purifying amount test for each of five products of appropriate product and inappropriate product based on filter quality test showed average 4,440 liters for appropriate product and average 2,620 liters for inappropriate product. According to the result, it is shown that the filter with good adsorption also had good chloroform removal efficiency and adsorption efficiency. Therefore, it is expected that customers can screen good quality product through obligatory conduct of filter quality test. However, it is considered that complementation in system is required for future inspection.

A Case Study on the Customer Circulation of Food Court Restaurants in Department Stores (백화점 푸드코트 식당의 고객 동선에 관한 사례 연구)

  • Lee, Jong-Ran
    • Journal of The Korean Digital Architecture Interior Association
    • /
    • v.12 no.1
    • /
    • pp.53-59
    • /
    • 2012
  • This research studied the characteristics of the customer circulation in four department store food court restaurants located in Seoul. The characteristics of the customer circulation are the following: Before customers leave the dining space where they eat food, they come and go to spaces such as the water purifier space, the napkin storage, and the cup storage. On the other hand, they do not come and go from the dining space to the waste area or the area where used cups are returned. Therefore the spaces, that need to be located very near the dining space, are the water purifier space, the cup storage, and the napkin storage. The waste area does not have to be placed very near the dining area and the area where used cups are returned is not needed. A minority of customers drink water and use napkins after going to the waste area and the area where dirty dishes are kept. To prevent these customers from going against the circulation of the majority of customers, a water purifier space, a cup storage, and a napkin storage should be placed additionally connecting to the waste area and the area where dirty dishes are kept. For effective circulation plan and spatial composition of food court restaurants, these characteristics of customer circulation should be considered. It is not recommended to place the water purifier space, the napkin storage, and the cup storage, the waste area or the area where used cups are returned, and the hand cleansing facility in the same location just for the convenience of workers.

Analytical Study on the Performance Characteristics of an Instant Cooling Type Water Purifier with the Design Parameters of the Cooling Tank (순간냉각식 정수기 냉수조의 설계변수에 따른 성능 특성에 관한 해석적 연구)

  • Jeon, Yong-Seok;Park, Hong-Hee;Lee, Joo-Seoung;Kim, Yong-Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.7
    • /
    • pp.545-552
    • /
    • 2012
  • The objective of this study is to analyze the effect on the energy consumption of an instant cooling type water purifier by the design parameters of the cooling tank. Initially, the simulation program was developed and verified. The simulation results showed that the energy consumption was reduced by replacing the shape of the cooling tank from a rectangular to a cube, increasing the evaporator length, decreasing the volume of the cooling tank, and increasing the performance of the insulator. The order of the effect magnitude on the energy consumption was as follows; volume of the cooling tank, conductivity and thickness of the insulator, shape of the cooling tank, length of the evaporator, and length of the water tube.