• Title/Summary/Keyword: water potential

Search Result 5,615, Processing Time 0.035 seconds

N Uptake and Assimilation of Barley Seedlings as Affected by N Availability, Temperature and Water Potential (질소량, 온도, 수분포텐셜 조절에 따른 보리유묘의 질소흡수 및 체내동화)

  • Kim, Sok-Dong;Kwon, Yong-Woong;Soh, Chang-Ho
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.38 no.5
    • /
    • pp.458-465
    • /
    • 1993
  • Water culture experiments were carried out to elucidate the effects of N availability, temperature and water potential of culture solution on the uptake and assimilation of N and dry matter accumulation by barley seedlings. N assimilation and dry matter accumulation at 3 to 4 leaves stage in barley plants were maximized at about 3.4 % of N concentration in leaf. N assimilation by barley plants increased with increase of nitrate concentration up to 80ppm in the solution. Over this level nitrate began to accumulated in the leaves and stems proportionally to the N availability in culture solution. Nitrate reductase activity increased in parallel with the increase in the concentration of reduced N in leaves. N uptake by barley plants decreased markedly when water potential reduced below -2 bar or when temperature dropped below 5$^{\circ}C$. These results suggest that the basal application rate of N, 60kg per hectare, for the barley crop needs to be re-examined under the concept of N use efficiency with taking into consideration of temperature and soil N availability because about a half of N accumulated in the leaves of barley plant before wintering is known to be lost by winter killing of above-ground part of the plant.

  • PDF

Estimation of Potential Evapotranspiration using LAI (LAI를 고려한 잠재증발산량 추정)

  • Kim, Joo-Hun;Kim, Kyung-Tak
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.8 no.4
    • /
    • pp.1-13
    • /
    • 2005
  • In the process of a hydrology circulation, evapotranspiration is considered a very important factor to build a plan for the development of water resources and to operate water resources system. This study purposes to estimate daily potential evapotranspiration quantity in consideration of energy factors of the surface by using spatial information such as Landsat TM (ETM+) data, DEM and Landcover. Kyounan-cheon, Han River is selected as a target area, and landcover is divided by vegetation and non-vegetation covered area. Penman-Monteith equation which considers leaf-area index is used to estimate potential evapotranspiration quantity of vegetation covered area. The combination method (energy burget and aerodynamic method) is used in non-vegetation covered area. Among the input data for estimating potential evapotranspiration, NDVI, SR and Albedo is formed by Landsat, TM and ETM+ from 1986 through 2002. ground heat flux is estimated by using NDVI distribution map, LAI distribution map is drawn by using SR distribution map. The result of estimation shows that the average potential evapotranspiration in the whole basin is about 1.8-3.2mm/day per each cell. THe results of estimating potential evapotranspiration quantity by each landcover are as follows; water surface 3.6-4.9mm/day, city 1.4-3.1mm/day, bareland 1.4-3.5mm/day, grassland 1.7-3.7mm/day, forest 1.7-3.0mm/day and farmland 1.8-3.6mm/day. The potential evapotranspiration quantity is underestimated in comparison with observed evaporation data by evaporation pan, but it is considered that it has physical propriety.

  • PDF

Characterization of Water-Filled Ag/AgCl Reference Electrode

  • Bahn Chi Bum;Oh Sihyoung;Hwang Il Soon;Chung Hahn Sup;Jegarl Sung
    • Journal of the Korean Electrochemical Society
    • /
    • v.4 no.3
    • /
    • pp.87-93
    • /
    • 2001
  • Pressure-balanced external Ag/AgCl electrode has been extensively used for both Pressurized Water Reactor (PWR) and Boiling Water Reactor (PWR) environments. The use of KCI-based buffer solution often becomes the source of electrode potential drift due to slow leakage through its porous plug, typically made of zirconia. It is reported that results of our effort to improve the stability of electrode potential by using high purity water as the filling solution in which $Cl^-$ ion activity can be established and maintained at the solubility of AgCl even with the sustained leakage for a long period. Stability tests have been made in boron and lithium mixture solution at $288^{\circ}C$. The electrode potential remained stable within 10 mV over one week period. And after a thermal cycle between 288 to $240^{\circ}C$ the potential shift of Ag/AgCl electrodes did not exceed 15 mV By using the limiting equivalent ionic conductances and Agar's hydrodynamic theory, the thermal liquid junction potential (TLJP) of the electrode has been predicted. The calculated values for the water-fiued Ag/AgCl electrode potential, in which the chlorine concentration in the filling solution was derived from the measured data at ambient temperature, had a good agreement with the experimental values.

The Study on the Corrosion Behavior of Al-alloy Radiator for Automobile in Fresh Water (청수 중에서 자동차용 Al합금 방열기의 부식거동에 관한 연구)

  • 임우조;이상열;윤대영
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.38 no.4
    • /
    • pp.265-270
    • /
    • 2002
  • Most of all the mechanical devices are becoming more high-speed and high-power as well as their used condition being more pollution with rapid development in industrial part. So, it is necessary for these devices to equip cooling system to overcome that kind of severe using condition. Industrial development and income increase causes rapid increase in using fossilenergy and it results in accelerating environmental pollution owing to the increasement in emission of air pollution substance. Specially, fresh water like stream and river water is acidified. Therefore, corrosion damage is accelerated in radiator for automobile that is using acidified water. So, in this study, corrosion test was carried out in distilled and tap water for the investigation on the corrosion behavior of Al-alloy that is using as material for radiator of automobile The main results obtained are as follows According to increase of temperature, open circuit potential is decreased in fresh water. And open circuit potential after deaeration is lower than that before deaeration. Corrosion current density in distilled water is less drained than that of tap water. And Corrosion current density after deaeration is less drained than that before deaeration.

A Study on Electrostatic Discharging in Ultrapure and Electrolyzed Waters Using Kelvin's Thunderstorm Effect (캘빈방전 효과를 이용한 초순수 및 전해이온수의 정전기 방전 연구)

  • Kim, Hyung-won;Jung, Youn-won;Choi, In-sik;Choi, Byung-sun;Choi, Donghyeon;Ryoo, Kun-kul
    • Journal of the Semiconductor & Display Technology
    • /
    • v.21 no.1
    • /
    • pp.5-11
    • /
    • 2022
  • Despite the increasing importance of manufacturing and application R&D for ultrapure deionized water and electrolyzed ion water, various and systematic studies have not been conducted until now. In this study, the electrostatic discharge (ESD) behavior of electrolyzed ion water using a proton exchange membrane(PEM) was evaluated according to the type, flow rate, and bubble of electrolyzed ion water. In addition, by observing that Oxidation Reduction Potential (ORP) value returns to the unique value of electrolyzed ion water after electrostatic discharge, the possibility of two types of ions participating in electrostatic discharge ((H2O)n+ (assumed)) and ions for maintaining the characteristics of electrolyzed water could be inferred. In order to confirm the chemical structure and characteristics of the cations, in-depth research related to water molecular orbital energy or band gap should be followed.

Voltammetric Studies of Anion Transfer Reactions Across a Microhole Array-Water/PVC-NPOE Gel Interface

  • Hossain, Md. Mokarrom;Girault, Hubert H.;Lee, Hye-Jin
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.5
    • /
    • pp.1734-1740
    • /
    • 2012
  • Voltammetric characterization of hydrophilic anion transfer processes across a 66 microhole array interface between the water and polyvinylchloride-2-nitrophenyloctylether gel layer is demonstrated. Since the transfer of hydrophilic anions including $Br^-$, $NO_3{^-}$, $I^-$, $SCN^-$ and $ClO_4{^-}$ across the liquid/gel interface usually sets the potential window within a negative potential region, a highly hydrophobic organic electrolyte, tetraoctylammonium tetrakis(pentafluorophenyl)borate, providing a wider potential window was incorporated into the gel phase. The transfer reaction of perchlorate anions across the microhole-water/gel interface was first studied using cyclic voltammetry and differential pulse voltammetry. The full voltammetric response of perchlorate anion transfer was then used as a reference for evaluating the half-wave transfer potentials, the formal transfer potentials and the formal Gibbs transfer energies of more hydrophilic anions such as $Br^-$, $NO_3{^-}$, $I^-$, and $SCN^-$. The current response associated with the perchlorate anion transfer across the micro-water/gel interface versus the perchlorate concentration was also demonstrated for sensing applications.

Investigation on Flocculi-floc Interaction and Flocculation in Extracellular Polymeric Substances, Ionic Species and Clay-containing Suspension (생체고분자물질 농도와 이온강도에 따른 점토입자 현탁액의 응집핵-응집체 이군집 응집 특성 연구)

  • Kim, Jae In;Lee, Byung Joon
    • Journal of Korean Society on Water Environment
    • /
    • v.36 no.3
    • /
    • pp.185-193
    • /
    • 2020
  • Bimodal flocculation describes the aggregation and breakage processes of the flocculi (or primary particles) and the flocs in the water environment. Bimodal flocculation causes bimodal size distribution with the two separate peaks of the flocculi and the flocs. Extracellular polymeric substances and ionic species common in the water environment increase the occurrence of bimodal flocculation and flocculi-floc size distribution, under the flocculation mechanisms of electrostatic attraction and polymeric bridging. This study investigated bimodal flocculation and flocculi-floc size distribution, with respect to the extracellular polymeric substance concentration and ionic strength in the kaolinite-containing suspension. The batch flocculation tests comprising 0.12 g/L of kaolinite showed that the highest flocculation potential occurred at the lowest xanthan gum (as extracellular polymeric substances) concentration, under all the ionic strengths of 0.001, 0.01, and 0.1 M NaCl. Also, it was important to note that the higher ionic strength resulted in the higher flocculation potential, at all the xanthan gum concentrations. The bimodal flocculation and flocculi-floc size distribution became apparent in the experimental conditions, which had low and intermediate flocculation potential. Besides the polymeric bridging flocculation, steric stabilization increased the flocculi mass fraction against the floc mass fraction, thereby developing the bimodal size distribution.

Sustainable Fresh Water Resources Management in Northern Kuwait-A Remote Sensing View From Raudatain Basin

  • Saif ud din;Dousari Ahmad AI;Ghadban Abdulnabi AI
    • Proceedings of the KSRS Conference
    • /
    • 2005.10a
    • /
    • pp.153-164
    • /
    • 2005
  • The paper presents time and cost effective remote sensing technology to estimate recharge potential of fresh water shallow aquifers for their sustainable management in arid ecosystem. Precipitation measurement of Raudatain Basin in Kuwait from TRMM data has been made and integrated with geological, geomorphological and hyrological data, to estimate the recharge potential of the basin. The total potential recharge to the area is estimated as 333.964 MCM annually. The initial losses are estimated at $60\%$ of the net precipitation .The net available quantity for recharge is 133.58 MCM. For sustainable management of the ground water resources, recharge wells have been proposed in the higher order streams to augment the Raudatain aquifer in Kuwait. If the available quantity of precipitation can be successfully utilized, it will reduce considerable pressure on desalination, which is leading to increased salinity off the coast in Arabian Gulf.

  • PDF

Surface Modification of Cement-Reinforcing Carbon Fibers by Low Temperature Plasma Process (저온 플라즈마 공정을 이용한 시멘트 보강용 탄소 섬유의 표면개질)

  • Cho, Dong Lyun;Kim, Hoon
    • Applied Chemistry for Engineering
    • /
    • v.16 no.3
    • /
    • pp.361-365
    • /
    • 2005
  • Cement-reinforcing carbon fibers were surface-modified with $O_2$, $H_2O$, acrylic acid, diaminocyclohexane plasmas and their effects were investigated. Hydrophobic surfaces with water contact angles of $75{\sim}80^{\circ}$ were changed to hydrophilic surfaces. The water contact angles were reduced down to lower than $10^{\circ}$. As a result, the fiber's hygroscopic property and dispersion in water were improved. Also, Zeta potential of the fiber in water was changed from a negative value to positive values. As a result, adhesion with cement that had a negative Zeta potential was improved up to 57~124% through increased electrostatic interaction.

Continuous removal of phosphorus in water by physicochemical method using zero valent iron packed column (영가철 충진 컬럼을 이용한 연속적인 물리화학적 수중 인 제거)

  • Jeong, Jooyoung;Ahn, Byungmin;Kim, Jeongjoo;Park, Jooyang
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.4
    • /
    • pp.439-444
    • /
    • 2013
  • Excessive phosphorus in aquatic systems causes algal bloom resulting in eutrophication, DO depletion, decline in recreational value of water and foul tastes. To treat wastewater containing phosphorus including effluent of wastewater treatment plant, the continuous experiments were performed by using electrochemical way. The spherical ZVI and silica sand which act as physical filter are packed at appropriate volume ratio of 1:2. Electric potential is applied externally which can be changed as per the operational requirement. The results indicate that optimum hydraulic retention time of 36 minutes (10 mL/min at 1 L reactor) was required to meet the effluent standards. Lower concentrations of phosphorus (<10 mg/L as phosphate) were removed by precipitation by contact with iron. Thus, additional electric potential was not required. In order to remove high concentration phosphorus around 150 mg/L as phosphate, external electric potential of 600 V was applied to the reactor.