• Title/Summary/Keyword: water pollution process test standard

Search Result 7, Processing Time 0.026 seconds

Analyzing the Differential Views between the Designers and the Users on Certification Assessment Criteria of the G-SEED System - Focused on Certification Assessment Criteria for Apartment Buildings - (녹색건축 인증제도 평가항목에 대한 설계 실무자 및 사용자 의식 차이 분석 - 공동주택 인증 평가항목을 중심으로 -)

  • Choi, Yeo-Jin
    • KIEAE Journal
    • /
    • v.15 no.6
    • /
    • pp.87-92
    • /
    • 2015
  • Purpose: The green building certification system in Korea was introduced in 2002 and developed as an improvement version of the G-SEED(Green Standard for Energy and Environmental Design) system in 2013. This study conducts surveys targeting architectural designers and users on significance of certification assessment criteria for apartment buildings on the G-SEED system and examines the differential views between the two groups on assessment criteria. Method: First, The AHP(Analytic Hierarchy Process) method was used to find importance of assessment criteria and then the importances were compared with weighted points on the certification standard. Second, the t-test was used to investigate differential views between designer and user groups on certification assessment criteria based on drawn importances. Result: (1) While designer group considered land use and transportation, energy and environmental pollution, and water circulation management as more important, user group did material and resource, maintenance management, ecological environment, and indoor environment as more important. (2) Based on t-test results, sustainable energy, water circulation system, site management, habitat, acoustical environment, and light environment were found to be different on importance between the two groups.

Comparison of Instrument Characteristics on the Total Organic Carbon Analysis Method in Water Samples (수질분야 총유기탄소 분석방법에 따른 장비별 특성 비교)

  • Hye-Sung Kim;Eun-Tae Hwang;Chan-Geun Lee;Young-Cheol Cho
    • Journal of Environmental Impact Assessment
    • /
    • v.32 no.5
    • /
    • pp.353-362
    • /
    • 2023
  • TOC, which can measure more than 90% of organic substances, can be measured quickly and easily,replacing BOD and COD, which were indicators of organic pollutants. According to water quality pollution control standards, when measuring TOC, if the inorganic carbon ratio in the sample is over 50%, the NPOC (Non-Purgeable Organic Carbon) method should be used. If volatile organic compounds (VOCs) are present at a certain concentration, the TC-IC (subtracting inorganic carbon from total carbon) method should be used. To validate the limitations of these analytical conditions, experiments were conducted by varying the ratio of TOC to IC in purified water and measuring the concentration of TOC in test solutions. The results showed no significant difference between the TC-IC method and the NPOC method. When measuring samples with added VOC standard solutions, it was observed that the carbon loss due to purging was not significant when using the NPOC method. Therefore, it is concluded that the choice of analytical method does not lead to significant differences when VOCs are present in the sample. To account for potential variations in results based on water quality pollution control standards and regulations regarding the approval and testing of environmental measurement devices, a comparison of field sample concentration values was made using two widely used types of TOC analyzers in Korea. The results showed variations of 0.02 to 0.83 mg/L between methods depending on the manufacturer, highlighting the need for caution when selecting an instrument.

A Study on Water Quality for Golf Course Pond in Northern Areas in Gyeonggi Porvince (경기도 북부지역 골프장연못 수질특성에 관한 연구)

  • Kim, Jae-Kwang;Hwang, Chan Won;Park, Jin-Ho;Kim, Ji Young;Oh, Jo-Kyo
    • Journal of Environmental Health Sciences
    • /
    • v.44 no.4
    • /
    • pp.323-329
    • /
    • 2018
  • Objectives: The purpose of this study is to investigate the water quality of 16 golf course ponds located in northern areas Gyeonggi province by investigating residual pesticides, organic matters (BOD, TOC) and nutrients (TN, TP). Methods: The result data for the residual pesticides were used from 2014 to 2017. and other result data were used for April and July in 2017. The residual pesticides analytical method was based on 'Golf course residual pesticides inspection method', The others analytical method was based on 'The water pollution process test standard' Results: Very toxic pesticides and banned pesticides were not detected but general pesticides were detected. In case of the water quality of the golf course pond was applied to the lake water quality standard. In April the average TOC concentration was V grade to 6.46 mg/L, TP V grade to 0.13 mg/L, TN VI grade to 1.6 mg/L, In July TOC average concentration was VI grade to 8.65 mg/L, TP VI grade to 0.17 mg/L, TN V to 1.5 mg/L. All TN and TP concentrations corresponded to eutrophication. Compared with lake water quality monitoring, the concentrations of BOD, TOC and TP were high but the TN concentration was low in April and July. Conclusions: It is considered that water quality managements are necessary for the golf course pond. The first reason is that the pollutants of pond are discarded to river during rainfall and act as pollution sources. The second reason is that the golf course users are uncomfortable because of odor caused by the pollutants of the pond.

A Study on Removal of Organism and Nitrogen, Phosphorus in Wastewater Treatment Process Using Nitrifier Activated Reactor (질산화균 활성화조를 이용한 하수처리 공정에서의 유기물 및 질소, 인 제거에 관한 연구)

  • Dong, Young-tak;Seo, Dong-whan;Bae, Yu-jin;Park, Ju-seok
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.21 no.6
    • /
    • pp.727-735
    • /
    • 2007
  • The use of water by cities is increasing owing to industrialization, the concentration of population, and the enhancement of the standard of living. Accordingly, the amount of waste water is also increasing, and the degree of pollution of the water system is rising. In order to solve this problem, it is necessary to remove organisms and suspended particles as well as the products of eutrophication such as nitrates and phosphates. This study developed a high-end treatment engineering solution with maximum efficiency and lower costs by researching and developing a advanced treatment engineering solution with the use of Biosorption. As a result, the study conducted a test with a $50m^3/day$ Pilot Scale Plant by developing treatment engineering so that only the secondary treatment satisfies the standard of water quality and which provided optimal treatment efficiency along with convenient maintenance and management. The removal of organisms, which has to be pursued first for realizing nitrification during the test period, was made in such a way that there would be no oxidation by microorganisms in the reactor while preparing oxygen as an inhibitor for the growth of microorganism in the course of moving toward the primary settling pond. The study introduced microorganisms in the endogeneous respiration stage to perform adhesion, absorption, and filtering by bringing them into contact with the inflowing water with the use of a sludge returning from the secondary settling pond. Also a test was conducted to determine how effective the microorganisms are as an inner source of carbon. The HRT(Hydraulic Retention Time) in the nitrification tank (aerobic tank) could be reduced to two hours or below, and the stable treatment efficiency of the process using the organisms absorbed in the NAR reactor as a source of carbon could be proven. Also, given that the anaerobic condition of the pre-treatment tank becomes basic in the area of phosphate discharge, it was found that there was excellent efficiency for the removal of phosphate when the pre-treatment tank induced the discharge of phosphate and the polishing reactor induced the uptake of phosphate. The removal efficiency was shown to be about 94.4% for $BOD_5$. 90.7% for $COD_{Cr}$ 84.3% for $COD_{Mn}$, 96.0% for SS, 77.3% for TN, and 96.0% for TP.

A Study on Water Purification Effect of Media Block Using Porous Ceramics and Zeolite (다공성 세라믹과 제올라이트를 활용한 수질정화미디어블럭의 효과 연구)

  • Jeon, Sung-yool;Koo, Bon-hak
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.20 no.5
    • /
    • pp.59-66
    • /
    • 2017
  • Preeminent water treatment plans are essential to preserve the water quality of aquatic biotopes. Previous studies have not been sufficient to provide cost-effective maintenance method since they focused only on the purification of deteriorated water that requires a continuous supply of clean water. This study proposes an economical method of water quality maintenance using water treatment media block constructed vertically using porous ceramics, zeolite, and river pebble. The water treatment media block does not require a separate purification area because it functions as a purifier within the ecological pond which can maximize the biotope area. To evaluate the performance of the water treatment media block, we longitudinally tracked the change of water quality indicators (pH, TDS, COND, DO, T-P, T-N, COD) suggested by Water Environment Standards, Ministry of Environment, Republic of Korea. We compared the water quality of one control (A: general ecological pond composition method of the laminated structure) and two experimental groups (B: a combination of aquatic plants and a water treatment media block, C: a water treatment media block only). As a result, we confirmed that the water treatment media block is an efficient and economical method to maintaining the water quality of the ecological pond for a long time. The water treatment media block will be a great help in providing a better aquatic biotope space for aquatic insects and fishes living in clear water.

Analysis of Permeation Efficiency in Soil for OPC and Non-Pollution MIS Grouts by Laboratory Model Test (실내모형시험을 통한 OPC와 친환경 MIS 그라우트의 지반 침투성능 분석)

  • Ahn, Jung-Ho;Lim, Heui-Dae;Choi, Dong-Nam;Song, Young-Su
    • Economic and Environmental Geology
    • /
    • v.45 no.3
    • /
    • pp.307-315
    • /
    • 2012
  • In this paper, a laboratory model test was conducted to evaluate grouting efficiency of ordinary portland cement(OPC) and micro cement used in MIS(Micro-Injection Process System). For this research, a injection equipment was developed for pressure permeation which can evenly simulate various grouting tests in a laboratory and suggested a standard for the production of the test specimen. Using the injection device, the laboratory injection tests of grouts were prepared with water/cement ratio of 1:1, 2:1, 3:1, 4:1, and 5:1. The analysis of injection test for pressure permeation showed that the efficiency of injection increases linearly as the water/cement ratio increases. Comparison of efficiency of the injection indicates that MIS with a relatively smaller average diameter shows more efficient injection than the OPC. In the low ratio of water/cement as 2:1~1:1, the injection efficiency of OPC was especially poor. Also, a nonlinear grout volume-injection time is represented by a hyperbolic model and grout volume predicted by hyperbolic model was compared with the value measured. From the comparison, it shows that the hyperbolic model has the potential of evaluating the efficiency of grouting.

Convergence Study of Antimicrobial Resistance of Escherichia coli Isolated from Cheonho Reservoir in Cheonan (천안 천호지에서 분리한 대장균의 항생제 내성에 관한 융합연구)

  • Lee, Jin Kyung;Lee, Young ki;Yuk, Young Sam;Kim, Ga-Yeon
    • Journal of the Korea Convergence Society
    • /
    • v.8 no.11
    • /
    • pp.141-149
    • /
    • 2017
  • This study was to investigate the sanitary microbiological aspects of Cheonho Reservoir and its antibiotic resistance in the natural environment to contribute to the public healthcare improvement. Groups of coliforms, were counted at three sites of the Cheonho Reservoir in July and September 2013, and the isolates were identified according to the water pollution process test standards. Antibiotic resistance was evaluated using the Korea National Institute of Health's standard antibiotic susceptibility test. The average coliform counts in Cheonho Reservoir were $2.0{\times}10^3CFU/mL$, 41% of which were identified as Escherichia coli(E. coli). Antibiotic resistance rate in E. coli isolated from Cheonho reservoir was highest in Ampicillin 31.3%, Ticarcillin 25.0%, Cefaxolin and Cefoxitin 18.8% respectively. Convergence multiple resistance patterns, 38,5% presented resistance to 4 durgs, 6 drugs resistance were 7.7%. The more than 2 drugs resistance were 92.3%. Cheonho Reservoir is a public park that accessible to the citizens, further convergence studies are needed to develop sanitary microbiological management practices and study antibiotic resistance of the reservoir.