• 제목/요약/키워드: water pollution

검색결과 3,218건 처리시간 0.025초

강원도 남대천, 연곡천과 사천천의 식물플랑크톤 군집 (The Phytoplankton community of Namdae-stream, Yeongok-stream and of Sacheon-stream in Gangwon-do)

  • 김용진;이옥민
    • 환경영향평가
    • /
    • 제20권3호
    • /
    • pp.281-297
    • /
    • 2011
  • The specie composition, stranding crops and the dominant species of phytoplankton were studied in three streams, Namdae-stream, Yeongok-stream and Sacheon-stream from May 2008 to February 2009. The water qualities of the three streams which run into estuary were also examined using phytoplankton indicators. As the result, the phytoplankton appeared 94 taxa in Namdae-stream, 79 taxa in Yeongok-stream and 73 taxa in Sacheon-stream, diatoms appeared the most in phytoplankton. Genus Navicula and Cymbella in diatoms appeared to be over 10 taxa in each stream, N. cryptocephala, N. cryptotenella and N. gregaria, the pollution tolerance taxa, appeared more frequent in the downstream. Due to the separation of each substrate by the rapid water velocity in the upstream, Achnanthes minutissima, a known periphyton, was dominant in upstream site at Namdae and Yeongok-stream. Some construction areas and sites of downstream of Namdae-stream, Yeongok-stream and Sacheon-stream were shown to be polluted because pollution tolerance taxa, such as Cyclotella meneghiniana, Nitzschia palea and Oscillatoria limnetica, were dominant. The total of 20 taxa phytoplankton indicators were found, composed of 16 taxa of Water pollution algae including Oscillatoria limosa, 2 taxa of Clean water algae Meridion circulare and Staurastrum puntulatum, 1 taxa of Toxic algae Microcystis aeruginosa and 1 taxa of Taste and odor algae Fragilaria construens. Water pollution indicators were appeared frequently in polluted sites of biological water quality(DAIpo, TDI) and of sites containing high trophic state index(TSI). Therefore, using the phytoplankton indicators can assess water quality through relation of biological water quality and trophic state index.

구조물의 해체 공정별 오염농도 변화 및 비점오염원 관리 방안 (Variations of the Pollutant Concentration by Explosive Demolition of a Building and Management Plan of Non-point Source Pollution)

  • 주경훈;유성수;김효진;이경희;고광백
    • 화약ㆍ발파
    • /
    • 제29권1호
    • /
    • pp.17-26
    • /
    • 2011
  • 본 연구는 실제 발파해체가 진행된 현장을 대상으로, 해체공정 중 천공과 발파작업시 발생하는 수질 및 토양오염의 농도변화를 통해 환경오염 정도를 조사하였고, 시간 경과에 따른 오염물질의 거동특성을 파악하여 해체현장에서의 비점오염원 관리방안의 필요성을 제시하였다. 그 결과 천공과 발파작업 이후 수질 및 토양의 pH는 콘크리트의 수산화칼슘에 의해 8.5~9.3으로 기준치를 초과하였다. 천공과 발파작업으로 인한 중금속의 농도는 대부분이 기준치 이내였으며, 수질과 토양오염에 크게 영향을 미치지 않는 것으로 판단되었다. 하지만 천공과 발파작업 전후의 오염물에 대한 증감률을 통해, 중금속 중 Cr, Cu, Zn 및 Hg의 농도가 증가된 것을 확인하였으며, 발생된 오염물의 처리방안이 필요하다고 판단되었다. 해체현장에서 시간의 경과와 우기에 따른 오염물질의 농도는 대부분 감소하는 경향을 보였으며, 이는 발생된 오염물질이 비점오염원으로 주변 환경에 영향을 줄 것으로 보인다.

수질오염총량관리를 위한 효율적 이행평가방안 연구 (A Study on the Method of Implementation Assessment for Total Maximum Daily Load Management)

  • 박준대;박주현;류덕희;정동환
    • 환경영향평가
    • /
    • 제17권2호
    • /
    • pp.125-132
    • /
    • 2008
  • It is desirable that implementation assessment (IA) should be carried out efficiently in order to make successful progress of Total Maximum Daily Load (TMDL) in watershed management. There are many difficulties in the process of the implementation assessment because of the early stage in the application of TMDL in Korea. This study reviewed the present status of IA and proposed the methodology of its improvement such as flexible application of TMDL ledger, and standardization of assessment index and criteria. The deficient time for assessment period could be corrected by the consideration of the post-procedure after the submission of IA report.

Derivation of Threshold Values for Groundwater in Romania, in order to Distinguish Point & Diffuse Pollution from Natural Background Levels

  • Radu, E.;Balaet, Ruxandra;Vliegenthart, F.;Schipper, P.
    • Environmental Engineering Research
    • /
    • 제15권2호
    • /
    • pp.85-91
    • /
    • 2010
  • Romania aims to adopt and implement the European Union's legislation, also including that for the field of water management. Like other countries, groundwater in Romania is locally polluted from point sources, such as leaking landfills, as well as from diffuse pollution sources, include fertilizers, pesticides and leakages from sewers, in urbanized areas. Diffuse pollution can also occur indirectly, by over-exploitation of groundwater wells, resulting in salt water intrusion, as well as from mining and exploitation of mineral aggregates. Romania has quite an intensive monitoring scheme to measure groundwater quality in phreatic and confined aquifers. The purpose of the work resumed in this paper was to derive natural background levels (NBL) for groundwater in order to distinguish the natural elevated concentrations of some substances (natural phenomena) from point and diffuse pollution (anthropogenic phenomena). Based on these NBLs, threshold values (TV) for groundwater will be set according to the requirements of the European Water Framework Directive and the related Groundwater Directive. This paper describes the results of a study for the derivation of NBL and TV in a pilot Groundwater Body. Also, the process and draft results for extrapolating this work for all Romanian groundwater bodies is explained, as well as points for future consideration with respect to monitoring and management.

강우 및 지역특성별 초기우수월류에 의한 오염부하 기여도 평가 (The Estimation of Pollution Loads in First-flush Overflows with Various Rainfall and Regional Characteristics)

  • 김홍태;신동석;김용석
    • 한국물환경학회지
    • /
    • 제30권6호
    • /
    • pp.622-631
    • /
    • 2014
  • The purpose of this research was to find a proper disposal rainfall extent to improve water quality. SWMM was applied to select catchment area and tested first flush load and rainfall extent. BOD 40mg/L was selected to dispose the first flush and sewer overflow with the same as the criteria of Sewerage Act. Design rainfall, BOD load ratio of first flush sewer overflow, and the ratio of disposal flow were analyzed under various rainfall distribution. BOD load and design rainfall to treat overflow in situation of first flush extent with 4.3~17.4% were 56~87% and 3.8~6.8 mm/day, respectively. In urban area, first flush loads were not correspond to land activities, but tend to increase with increasing rainfall amount and drainage area. The more the distribution of rainfall is similar to Huff-frontal or central distribution of rainfall, the more increase the first flush loads.

개념적 유역모델을 이용한 영산강 유역 오염부하 유출량의 시공간적 분포평가 (Estimation of Pollution Loads from the Yeongsan River Basin using a Conceptual Watershed Model)

  • 박민혜;조홍래;구본경
    • 한국물환경학회지
    • /
    • 제30권2호
    • /
    • pp.184-198
    • /
    • 2014
  • For estimating discharge and pollution loads into the Yeongsan lake, a conceptual watershed model HSPF(Hydrological Simulation Program - Fortran) was applied to the Yeongsan River Basin. Various spatial data set including DEM, watershed boundaries and land uses were used to set up the model for the Yeongsan River Basin that was divided into 45 sub-basins. The model was calibrated and validated for the river discharges, SS, BOD, TN and TP concentrations against the data observed in 2011 at several monitoring stations. The simulation results show good agreement with the observed water flows($R^2$ = 0.46 - 0.97, NSE = 0.70 - 0.96). The simulated concentrations of SS, BOD, TN and TP are also in good agreement with the observed. The total freshwater discharge to the Yeongsan lake is estimated $2,406{\times}10^6m^3/year$ which the Jiseok and Hwangryoung stream contribute as much as 19%, 17% respectively. It is estimated that the total discharges to the Youngsan lake is SS 152,327 ton/year, BOD 15,721 ton/year, TN 10,071 ton/year, TP 563 ton/year. Both water and pollution loads are high in summer, particularly in July, when the monsoon season arrives at the Korean peninsula.

무방류시스템 도입에 따른 환경규제효율화 방안 (Reformation of Environmental Regulation through introduction of the Zero Liquid Discharge System)

  • 최지용
    • 환경정책연구
    • /
    • 제2권1호
    • /
    • pp.31-49
    • /
    • 2003
  • It is difficult to examine the causal relation of pollution damages because the time gap between pollution cause and effect is large and new pollutants are continuously being produced. Their many environmental effects are not promptly studied. As both the study of causal relation about pollution and the pollutant treatment are becoming highly advanced by the development of science and environmental technology, both the economy and balance on environmental regulation may be discussed. It is reasonable to decide environmental policy in consideration of close relation between both the generation and resolution of environmental problems and of technological developments because environmental problems are related to complicated social problems and scientific technologies. First item in policy decision about environmental control and management is preferentially to consider the way of prevention. It is necessary to prevent pollution by regulating the installment of environmental pollution facility into the environmentally sensitive areas, like water supply source and to regulate land utilization as a method to achieve pollution prevention. Second is a consideration of environmental technology development. This is a solution which can accomplish the development of environmental technology and the reinforcement of economic competition. Third is the coexistence of environment and economy. It is necessary to consider economy in connection with environmental problems and environment in economic problem. Then, we can enjoy a healthy life as well as economic affluence. Fourth is the enlargement of environmental management means. Environmental management means must be diversified because environmental cause and effect are varied. For Improving the land use regulation system, it is necessary to consider both land use regulation status and pollutant toxicity with the development of environmental technology. Land use must be approached by classifying land to 3 levels; water source protection zone and water front zone, special zone 1 and 2, rancus and other zones. Land regulation policy to prevent any accident in water source protection zone, waterfront zone, and special zone must be continuously upgraded. However, economical consideration in other zones is required by the development of environmental technology.

  • PDF

이상적인 음료수 공급을 위한 수질관리에 관한 연구 (Study on the Water Management to get High Quality of Drinking Water)

  • 김형석;신현덕;박경석
    • 환경위생공학
    • /
    • 제6권1호
    • /
    • pp.7-25
    • /
    • 1991
  • Until now, pure drinking water grnerally menas the water without taste, odor, general bacteria, coliform, and other exotic substance. Such a definition has been changing recently due to the finding of numerous other inorganic and organic substances unknown to us. 10 years ago, major causes of death were infectious agents and parasites contained in water, but recently, it has become apparent that some substances contained in drinking water cause cancer and heart diseases. We must drink about 2L of water everyday in order to maintain healthy condition. Waters used for drinking include tap water, well water, spring water, filtered water, etc., but the quality of drinking water has more polluted due to the industrial development and population increase. For example, industrial waste waters from industrial plants pollute the water supply sources ; toxic substances contained in the waste waters pollute the ground water sources by penetrating the geological strata, and municipal, livestock, public building waste waters also pollute the water supply sources. Sometimes, the polluted surface waters were announced to be polluted by various kinds of orgainc substance, and it is reported that the pollution of ground water by orga nic substances has few in number but high in its concectration comparing with those of surface water. As the water quality pollution level increases, so the amount of disinfectant also increase. For example, chlorine solution, one of widely used disinfectants, creates trihalomethane(THM), a carcinogen, and halogen compounds. According to Oliver, through chlorine disinfection process, humine substance and chlorine create bolatile organic halide and nonvolatile organic halide by chemical reaction. There are tens or hundreds filtering devices, but filtering principles and maintenance metjhods are different, so their efficiency tests are needed. According to Smith, the effeciency tests aginst over 30 Ameican filtering devices show that 10 devices can remove 85% of volatile organics and further studies on filtered waters are underway. In consideration of important impacts of polluted drinking water on national health, authors studied the state of water quality pollution against tap water used as drinking water, filtration device passed water, ground water, and conserved drinking water ; tested the efficiency of filtration devices for tap water ; tried to sep up the detection method by using ion chromatography based on negative ion and positive ion by using single column, and attemped the simple filtration method for general households.

  • PDF