• Title/Summary/Keyword: water parameter

Search Result 1,917, Processing Time 0.03 seconds

A Study on Tuning Method of Turbine Speed Controller Using Fuzzy Inference (퍼지추론을 이용한 수차 속도제어기 동조기법에 관한 연구)

  • Lee, J.H.;Kim, W.H.;Paik, D.H.;Sung, K.M.;Shin, G.W.
    • Proceedings of the KIEE Conference
    • /
    • 1993.07a
    • /
    • pp.316-318
    • /
    • 1993
  • In order to estimation the optimum PID parameter of the turbine speed controller, the response cure of the object plant was compared with the reference pattern and then the magnitude peak value error and peak time error was calculated. With the calculated errors as input into the Fuzzy inference Method was introduced to propose the tuning method for each parameter. And the computer simulation was performed with the above Fuzzy inference method in which the Chunju hydro power plant turbine governor system was used as a model. This Study also aims to develop the exclusive tuner for govenor using industrial computer.

  • PDF

Prediction of the Volumetric Water Content Using the Soil-Water Characteristic Curve on an Unsaturated Soil (흙-수분 특성곡선 방정식을 이용한 체적함수비의 예측)

  • Song, Chang-Seob
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.7 no.6
    • /
    • pp.39-48
    • /
    • 2004
  • The purpose of this paper was to confirm the application of the equation of the soil-water characteristic curve on an unsaturated soil. To this ends, a series of suction test was conducted on the selected 4 kinds of soil which is located in Korea, using the modified pressure extractor apparatus. And it was carried out to analyze the experimental parameters which can describe the soil-water characteristics, were determined by using the data obtained from the experiment. From the results, it was found that the matric suction was varied according to the grain size distribution, amount of fine grain particle and void ratio. Also it was found that the residual volumetric water content was decreased with the void ratio, but the index related air entry value, the soil parameter related water content and the parameter with residual water content were increased with the void ratio. And the application of equation of the soil-water characteristic curve was confirmed for the various conditions and the various state by the comparison between the volumetric water content measured by the experiment and the predicted values.

Uncertainty of Water Supply in Agricultural Reservoirs Considering the Climate Change (미래 기후변화에 따른 농업용 저수지 용수공급의 불확실성)

  • Nam, Won-Ho;Hong, Eun-Mi;Choi, Jin-Yong
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.56 no.2
    • /
    • pp.11-23
    • /
    • 2014
  • The impact and adaption on agricultural water resources considering climate change is significant for reservoirs. The change in rainfall patterns and hydrologic factors due to climate change increases the uncertainty of agricultural water supply and demand. The quantitative evaluation method of uncertainty based on agricultural water resource management under future climate conditions is a major concern. Therefore, it is necessary to improve the vulnerability management technique for agricultural water supply based on a probabilistic and stochastic risk evaluation theory. The objective of this study was to analyse the uncertainty of water resources under future climate change using probability distribution function of water supply in agricultural reservoir and demand in irrigation district. The uncertainty of future water resources in agricultural reservoirs was estimated using the time-specific analysis of histograms and probability distributions parameter, for example the location and the scale parameter. According to the uncertainty analysis, the future agricultural water supply and demand in reservoir tends to increase the uncertainty by the low consistency of the results. Thus, it is recommended to prepare a resonable decision making on water supply strategies in terms of using climate change scenarios that reflect different future development conditions.

Numerical Analysis on Changes in Flowrate of Draft Water and Power by Changing Design Parameters of a Long-Distance Water Circulation (저층수 흡입식 광역 순환장치의 설계변수에 따른 배출량 및 소비동력 변화 특성에 대한 수치 해석 연구)

  • Song, Dong-Keun;Hong, Won-Seok;Kim, Young-Cheol;Park, Myong-Ha
    • The KSFM Journal of Fluid Machinery
    • /
    • v.13 no.1
    • /
    • pp.23-28
    • /
    • 2010
  • A draft tube which has impeller to elevate bottom water and spread it over surface of lake water, induces convective circulation of lake water, a Long-Distance Circulation (LDC). Circulation of lake water make stratified water mixed and enhance DO (Dissolved Oxygen) of bottom water. Circulation rate of water is determined by draft rate of the tube, which is dependent on design parameters of the draft tube system, i. e. dimension of impeller and diffuser, inclined angle of impeller, impeller shape, and rotational speed. In this study, change in draft rate and power consumption of circulation equipment was investigated numerically with changing impeller dimension, angle and rotational speed. It was found that flowrate of draft water was increased as the dimensions of draft tube and impeller, and rotational speed and inclined angle of impeller increased. The power consumption was also elevated with increasing parameter values, and final selection of parameter values was made to satisfy target flowrates and power consumption.

Evaluation of Coagulants Dispersion in Pump Diffusion Mixer for Water Treatment (CFD모사 기법을 이용한 Pump Diffusion Mixer내의 응집체 확산분포에 대한 평가)

  • Park, Young-Oh;Park, No-Suk;Kim, Seong-Su;Kim, Ki-Don;Lim, Kyung-Ho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.1
    • /
    • pp.49-63
    • /
    • 2008
  • The objectives of this research were to evaluate the pressurized/the main inlet water flowrate ratio which have been used as the most important parameter for operating the pump diffusion mixer until now, to suggest the alternative operating parameter and the relating criteria if the flowrate ratio was not inadequate. For the objectives of this research, computational fluid dynamics (CFD) simulation was conducted for 21 cases of flowrate ratio in full-scaled pump diffusion mixer. From the results of CFD simulation, the local velocity gradient values were calculated in each case in order to analyze the simulation results in more detail. For verifying CFD simulation, wet test was conducted. The wet test was to measure the factual coagulant dispersion distribution at a distance of 5.4m from deflector. From both results of CFD simulation and wet test, flowrate ratio was inadequate as operating parameter or criteria, on the other hand the pressurized/the main inlet velocity ratio(dimensionless) was useful in predicting the performance of pump diffusion mixer. Also, the injected coagulant could be dispersed evenly in overall cross section on the condition that pressurized/the main inlet velocity ratio(dimensionless) is over at least 20.

Calibration of Hydrologic Parameters of HSPF Using HSPEXP Model Performance Criteria (HSPEXP 모형평가지표를 이용한 HSPF 모형의 수문매개변수 보정)

  • Kim, Sang-Min;Seong, Choung-Hyun;Park, Seung-Woo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2009.05a
    • /
    • pp.116-119
    • /
    • 2009
  • HSPF is a comprehensive, continuous, lumped parameter, watershed-scale model that simulates the movement of water, sediment, and a wide range of water quality constituents on pervious and impervious surfaces, in soil profiles, and within streams and well-mixed reservoirs. The hydrologic calibration of HSPF is performed manually using the decision-support software Expert System for the Calibration of HSPF (HSPEXP). The initial values for the HSPF hydrologic parameters were estimated based on guidance from BASINS Technical Note 6. Initial parameter values were adjusted for the study watershed during the calibration period within the recommended ranges for the parameters.

  • PDF

Polymer Adsorption at the Oil-Water Interface

  • Lee, Woong-Ki;Pak, Hyung-Suk
    • Bulletin of the Korean Chemical Society
    • /
    • v.8 no.5
    • /
    • pp.398-403
    • /
    • 1987
  • A general theory of polymer adsorption at a semi-permeable oil-water interface of the biphasic solution is presented. The configurational factor of the solution in the presence of the semi-open boundary at the interface is evaluated by the quasicrystalline lattice model. The present theory gives the feature of the bulk concentration equilibria between oil-water subsystems and the surface excesses of ${\Gamma}^{\alpha}$ and ${\Gamma}^\{beta}$ of the polymer segments as a function of the degree of polymerization $\gamma$, the Flory-Huggins parameter in $\beta$-phase $x_{\rho}^{{\beta}_{\rho}}$, the differential adsorption energy parameter in $\beta$-phase $x_{\sigma}^{{\beta}_{\rho}}$, the differential interaction energy parameter ${\Delta}x_{\rho}$ and the bulk concentration of the polymer in ${\beta}-phase ${\varphi}_2^{{\beta(*)}_2}$. From our numerical results, the characteristics of ${\Gamma}^{\alpha}$ are shown to be significantly different from those of ${\Gamma}^{\beta}$ in the case of high polymers, and this would be the most apparent feature of the adsorption behavior of the polymer at a semi-permeable oil-water interface, which is sensitively dependent on ${\Delta}x_{\rho}$ and r.

Adsorption characteristic of Cu(II) and phosphate using non-linear and linear isotherm equation for chitosan bead (비선형과 선형 등온흡착식을 이용한 키토산비드의 구리와 인산염의 흡착특성)

  • Kim, Taehoon;An, Byungryul
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.34 no.3
    • /
    • pp.201-210
    • /
    • 2020
  • 2 (Langmuir, Freundlich, Elovich, Temkin, and Dubinin-Radushkevich) and 3 (Sips and Redlich-Peterson)-parameter isotherm models were applied to evaluated for the applicability of adsorption of Cu(II) and/or phosphate isotherm using chitosan bead. Non-linear and linear isotherm adsorption were also compared on each parameter with coefficient of determination (R2). Among 2-parameter isotherms, non-linear Langmuir and Freundlich isotherm showed relatively higher R2 and appropriate maximum uptake (qm) than other isotherm equation although linear Dubinin-Radushkevich obtained highest R2. 3-parameter isotherm model demonstrated more reasonable and accuracy results than 2-parmeter isotherm in both non-linear and linear due to the addition of one parameter. The linearization for all of isotherm equation did not increase the applicability of adsorption models when error experiment data was included.

An experimental study on the multiple parameter switching control for floor heating system (바닥 난방공간의 다인자 제어에 관한 실험적 연구)

  • Cho, S.H.;Tae, C.S.;Jang, C.Y.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.9 no.4
    • /
    • pp.472-483
    • /
    • 1997
  • An experimental facility consisting of two $3{\times}4.4{\times}3.8m$ rooms identical in construction is built. Each room has a control system and storage tank supplying hot water to the radiant floor heating system. The facility enables simultaneous comparision of two different control stratigies each implemented in a separate room. The operating performance of three kinds of flow control scheme is tested and compared in this study : (i) conventional on-off control based on feedback from room air temperature (ii) TPSC(two parameter switching control) (iii) TPOC(two parameter on-off control). Results show that TPSC and TPOC using room air and surface temperature sequentially as feedback signal to control hot water supply is the better temperature regulation scheme than conventional control based on feedback from only room air temperature. They are good candidates for the room with radiant floor heating system under continuous and intermittent heating mode.

  • PDF

The Research about the Water Quality Prediction at Imha Reservoir Using a WASP7 Model (WASP7 모형을 이용한 임하호 수질모의에 관한 연구)

  • Ahn, Seung-Seop;Seo, Myung-Joon;Jung, Do-Joon;Park, Ro-Sam
    • Journal of Environmental Science International
    • /
    • v.17 no.6
    • /
    • pp.611-621
    • /
    • 2008
  • This study intends to provide the necessary basic data needed for predicting the water quality and examining changes in water quality on the basis of the hydrological changes: an outflow or the character of a flow by investigating the interaction of the parameters through the estimation of optimal parameters need for predicting the water quality of the dam basin and the sensitivity among those estimated parameters. Im-Ha Dam in the upstream area of the Nakdong River was selected for analysis, and the water quality survey data necessary for parameter estimation was based on the monthly water quality data (water temperature, BOD, T-N and T-P) between December 1, $2005{\sim}$November 31, 2006. K1C(the saturated growth rate of plant plankton), K1RC (endogenous respiratory quotient of plankton), KDC(deoxidized ratio), K71C(minealized ratio of dissolved organic phosphorus), K83C(mineralized ratio of dissolved organic nitrogen) have been considered as the factors of the water quality performed in this water quality simulation, that is, the most effective parameters on BOD, T-N and T-P. In the result of the analysis of the sensitivity, KDC(deoxidized ratio) was the most sensitively reacted parameter on BOD and it was K71C(mineralized ratio of dissolved organic phosphorus) and K83C(mineralized ratio of dissolved organic nitrogen) on T-N and T-P. It is considered that it will be possible to apply the most optimal parameter to an analysis of the water quality simulation at Im-Ha Ho basin in the goal year by examining the interaction of the parameters through the parameters sampling which are able to applicable to prediction of the water quality and the analysis of the its sensitivity, in the future, also the analysis on the basis of the hydrological conditions: an outflow or the character of a flow will be needed.