• Title/Summary/Keyword: water need

Search Result 1,965, Processing Time 0.027 seconds

Object-oriented Prototype Framework For Tightly Coupled GIS-based Hydrologic Modeling (객체지향성 프로그래밍 방법을 통한 GIS 연계의 수문모델)

  • Kang, Kwang-Min;Rim, Chang-Soo;Yoon, Sei-Eui
    • Journal of Korea Water Resources Association
    • /
    • v.45 no.6
    • /
    • pp.597-606
    • /
    • 2012
  • With the availability of multi-scale hydrologic data in public domain depending on DEM size, there is a need for a modeling framework that is capable of using these data to simulate hydrologic processes at multiple scales for different topographic and climate conditions for distributed hydrologic model. To address this need, an object-oriented approach, called Geographic and Hydrologic Information System Modeling Objects (GHISMO), is developed. Main hydrologic approaches in GHISMO are storage-release for direct runoff and SCS curve number method for infiltration part. This paper presents conceptual and structural framework of storage-release concept including its application to two watersheds will be presented.

A Study on the Performance Appraisal for Copper Sheet as Root Barrier Material Appling to Green Roof System (옥상녹화 및 인공지반녹화용 구리시트 방근재의 성능평가에 관한 연구)

  • Cho, Il-Kyu;Kwon, Shi-Won;Kwak, Kyu-Sung;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2007.04a
    • /
    • pp.5-8
    • /
    • 2007
  • Selection of proper root barrier as destination part of greening is very important in Root penetration resistance plan. To select proper root barrier, it need to understand composition of greening part, size, kind of plant, connection with waterproofing layer. In this point of view, we have establish greening on the roof or concrete structure, not been understand the structural mechanism. It means that we misunderstood about purpose of greening and using it. So, chosen materials and construction method was not proper for greening, it caused water leakage and decrease performance of concrete structure. Therefore, we examine the practical use of copper sheet considering environmental condition for green roof. Watertightness by water of greening part, root penetration resistance test by root penetration, bacteria resistance by must or bacteria in soil, chemical resistance by rain and chemical agent of fertilizer, and load resistance by soil depth, sire of plant. These suggested test methods could be referred as guideline to test in green roof system because of not exist any performance appraisal guideline or standard. Consequently, it should be analysis as technical and institutional subdividing test methods and it need to study constantly as varied angles.

  • PDF

Evaluation of Regression Models with various Criteria and Optimization Methods for Pollutant Load Estimations (다양한 평가 지표와 최적화 기법을 통한 오염부하 산정 회귀 모형 평가)

  • Kim, Jonggun;Lim, Kyoung Jae;Park, Youn Shik
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2018.05a
    • /
    • pp.448-448
    • /
    • 2018
  • In this study, the regression models (Load ESTimator and eight-parameter model) were evaluated to estimate instantaneous pollutant loads under various criteria and optimization methods. As shown in the results, LOADEST commonly used in interpolating pollutant loads could not necessarily provide the best results with the automatic selected regression model. It is inferred that the various regression models in LOADEST need to be considered to find the best solution based on the characteristics of watersheds applied. The recently developed eight-parameter model integrated with Genetic Algorithm (GA) and Gradient Descent Method (GDM) were also compared with LOADEST indicating that the eight-parameter model performed better than LOADEST, but it showed different behaviors in calibration and validation. The eight-parameter model with GDM could reproduce the nitrogen loads properly outside of calibration period (validation). Furthermore, the accuracy and precision of model estimations were evaluated using various criteria (e.g., $R^2$ and gradient and constant of linear regression line). The results showed higher precisions with the $R^2$ values closed to 1.0 in LOADEST and better accuracy with the constants (in linear regression line) closed to 0.0 in the eight-parameter model with GDM. In hence, based on these finding we recommend that users need to evaluate the regression models under various criteria and calibration methods to provide the more accurate and precise results for pollutant load estimations.

  • PDF

Efficient Management Method of Groundwater in Farming and Fishing Villages (농어촌 지하수의 효율적 관리 방안)

  • Jung, Chan-Duck;Kim, Yang-Bin;Park, Ki-Yeon;Park, Sun-Jin
    • Journal of Soil and Groundwater Environment
    • /
    • v.17 no.4
    • /
    • pp.81-90
    • /
    • 2012
  • Groundwater is our invaluable asset because it takes action in the case of climates changes like drought or floods. But the Korean government has formulated water-resource policies mostly focused on surface water. As a result, the groundwater that will be more important resource in the future has been treated carelessly, caused neglect of maintenance and resulted many abandoned wells. This poor management of groundwater is because of lack of organization on our asset, manpower, unclearness of managing body, shoddy construction and lack of supervision. In order to solve this problem, we need a special agency of groundwater that contribute people's awareness by promotion importance of groundwater, dissemination of technical education and professionals. To do that, we have to establish a specific groundwater management plan based on regional characteristics of watersheds and specialized institution need to promote responsible development and usage in groundwater.

Dietary Habits and Factors Associated with Depression in Yangpyeong-gun Elderly (양평군 노인에서 우울 지수, 영양불량과 식생활 실천 요인)

  • Hee Jung Park;Jae Young Lee;Wookyoun Cho
    • Journal of the Korean Society of Food Culture
    • /
    • v.38 no.6
    • /
    • pp.381-391
    • /
    • 2023
  • This study was conducted to analyze relationships between depression indices, mini nutritional assessment scores, and nutritional quotients among 80 elderly in Yangpyeong-gun and to identify factors that help prevent depression and malnutrition. Nutrition assessment scores were low in the high-risk group (PHQ-9 score ≥10), and nutritional quotient scores were lower in the high-risk group than in the normal group (PHQ-9 score ≤4). Interestingly, the consumption frequencies of fruits, eggs, and nuts were low in the high-risk group, and subjective health awareness, dental condition, and sleep were poorer. The total PHQ-9 score was correlated with malnutrition, body mass index, calf circumference, weight change, independent daily living, reduced meal amount, water intake, and the need for help when eating. Analysis of correlations between items of the PHQ-9 and nutritional status evaluation indices showed that a self-perceived feeling of depression, low energy, difficulty controlling sleep or appetite, negative thoughts (e.g., failure, disappointment), and difficulty concentrating were negatively correlated with total nutritional status scores. These results show that attention is required when food or water intake decreases and that deviation from normal sleep and appetite cycles flags the need to prepare guidelines to prevent depression.

Study on Antibiotic Resistant Bacteria in Surface Water Receiving Pharmaceutical Complex Effluent (제약공단 방류수 유입 하천에서의 항생제 내성 bacteria에 관한 연구)

  • Kim, Young Jin;Kim, Young Gyu
    • Journal of Environmental Health Sciences
    • /
    • v.42 no.6
    • /
    • pp.409-418
    • /
    • 2016
  • Objectives: The purpose of this study was to characterize penicillin G resistant bacteria in surface water from pharmaceutical complex effluent. Methods: Surface water was sampled from pharmaceutical complex effluent in Gyeonggi-do Province, Korea in March 2015. Water samples were plated in triplicate on tryptic soy agar plates with 32 mg/L of penicillin G. Penicillin G resistant bacteria were selected from the effluent and subjected to 16S rRNA analysis for the penicillin G resistant species determination. Identified resistant strains were tested for resistance to various antibiotics. Results: Penicillin G resistant bacteria were present at 8.0% in terms of culturable heterotrophic bacteria. Identified penicillin G resistant bacteria exhibited resistance to more than nine of the antibiotics studied. These resistant bacteria are gram negative and are closely related to pathogenic species. Conclusion: Multi-antibiotic resistant bacteria in the surface water of pharmaceutical complex effluent suggest the need for disinfection and advanced oxidation processed for pharmaceutical effluent.

A Study of Advanced Oxidation Process for Reuse of Industrial Wastewater (산업폐수 재이용을 위한 고급산화공정 시스템 연구)

  • Kim, Sung-Joon;Jin, Ming-Ji;Won, Chan-Hee;Hwang, Jeong-Seok;Lee, Gil-Yong
    • Journal of Korean Society on Water Environment
    • /
    • v.26 no.4
    • /
    • pp.580-584
    • /
    • 2010
  • As water becomes more scarce around the world the reuse of treated wastewater is being recenlty considered as indispensible trend we need to follow. Especially, industrial area consuming large amount of water has been encouraged to reuse the treated wastewater to secure sufficient water for the production of merchandise. In this study, a study of advanced oxidation process for treatment of industrial wastewater. The treatment performance of UV and ozoznation and five types advanced oxidation processes such as UV/AC, UV/Catalyst, $O_3$/Catalyst, UV/$O_3$/Catalyst was experimentally investigated for reuse of industrial wastewater. The removal efficiency of $COD_{Cr}$, color were relatively evaluated in each treatment unit simulated outflow water of wastewater treatment area. UV/$O_3$/Catalyst process showed the highest $COD_{Cr}$ remaval and color remaval among proposed oxidation process.

A Study of Design factors for Increasing Energy Production in Small Hydro power with Using Long Pipe (장대관로를 이용한 소수력 발전량 향상을 위한 설계요소에 관한 연구)

  • Kim, Hyun-Han;Kim, Kwang-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.8
    • /
    • pp.1134-1139
    • /
    • 2014
  • Recently the need for renewable energy development is expanding due to the global climate change, the environmental issues and the limited fossil energy resources. Dependence of energy on overseas is high in Korea. To resolve the environmental problems and to improve the energy independence rate, the development of renewable energy is more required. The small hydro power, one of the renewable energy resources, has been developing and operating from a long time ago. If we are new developing a small hydro power with the use existing dams and reservoirs, we will design the length of inlet pipe and the diameter suitable for it. However, in case of using the existing water supply pipe which had been designed suitable for water service, the designer has to review and check that the pipe is suitable for operating a generator. In this paper, the design of small hydro power using the existing long pipe of water supply, we suggest the optimum way to reduce the water hammer in pipe which causes the unsteady flow during the load-shutdown of generator, the generator operation plan for the stable supply of water and the design factor of determining the generator capacity through the analysis between discharge and head-loss.

Management for Improvement in Water Quality and Change of Fish Assemblage in Urban Dong Stream with Input of Seawater (해수 투입에 따른 동천 주변 환경 개선 평가를 위한 어류상 변화 및 관리 방안)

  • Kwak, Seok-Nam;Kim, Dong-Myung;Chung, Yong-Hyun
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.27 no.1
    • /
    • pp.253-261
    • /
    • 2015
  • The chemical water quality and fish assemblage of Dong Stream to assessment of environmental improvement after discharge seawater were investigated from July to December 2013. BOD and DO were significantly different between before and after discharge seawater, while pH and SS did not significant. A total of 11 fish species, 218 individuals and 10,525.1g were collected. Dominant fish species were Mugil cephalus, Konosirus punctatus, Acanthogobius flavimanus and Leiognathus nuchalis which account for 77.5% of total individuals collected, and they were estuarian species. Peak number of species and individuals, and biomass occurred in September, whereas diversity index were highest in November. The water ecosystem of Dong Stream have been changed estuarian environment. As a result of stream assessment on water quality and ecosystem, water quality have been improved as 'III' grade. These results suggested that stream restoration policies such as drain pipes maintenance, management of pollution sources and riverbed dredging to improve environment and recover habitate of Dong Stream were need for set up and establishment of regular monitoring system.

Earthquake Observation through Groundwater Monitoring: A case of M4.9 Odaesan Earthquake (지하수 모니터링을 통한 지진 감시 가능성: 중규모(M4.9) 오대산 지진의 관측)

  • Lee, Hyun-A;Kim, Min-Hyung;Hong, Tae-Kyung;Woo, Nam-C.
    • Journal of Soil and Groundwater Environment
    • /
    • v.16 no.3
    • /
    • pp.38-47
    • /
    • 2011
  • Groundwater monitoring data from the National Groundwater Monitoring Stations, a total of 320 stations, were analyzed to identify the response of water level and quality to the Odaesan earthquake (M4.9) occurred in January 2007. Among the total of eight stations responded to the earthquake, five wells showed water-level decline, and in three wells, water level rose. In terms of recovery, water levels in four stations had recovered to the original level in five days, but not in the rest four wells. The magnitude of water-level change shows weak relations to the distance between the earthquake epicenter and the groundwater monitoring station. However, the relations to the transmissivities of monitored aquifer in the station with the groundwater change were not significant. To implement the earthquake monitoring system through the groundwater monitoring network, we still need to accumulate the long-term monitoring data and geostatistically analyze those with hydrogeological and tectonic factors.