• 제목/요약/키워드: water level and temperature

검색결과 1,178건 처리시간 0.038초

지구환경 변화와 관련된 한국 연근해 해양 이상변동 (Anomalous Variation of the Oceanic Features around Korean Waters Related to the Global Change)

  • 서영상;장이현;황재동
    • 한국환경과학회지
    • /
    • 제12권3호
    • /
    • pp.257-263
    • /
    • 2003
  • Oceanographic features around Korean waters related to the global change were studied by analysis of the longterm variation of water temperature, dissolved oxygen, sea level of the surface layer with 1$^{\circ}C$ temperature, spatial position of the subpolar front in the East Sea/Japan Sea (the East sea hereafter) and the Wolf Sunspot Number. With the global warming, the temperature of Korean waters has been increased 0.5∼1.0$^{\circ}C$ for 33years (1968∼2000). In case of the dissolved oxygen in the East Sea has been decreased 0.46$m\ell$/$\ell$. Year to year vertical fluctuations of the monthly anomalies of the surface layer with 1$^{\circ}C$water in the East Sea have predominant periods with 15years as the longterm variation of Arctic climate, 12 and 18years as the El Nino-Southern Oscillation. Spatial position of the subpolar front in the East Sea moved to northern part of the sea from the southern part of the sea with the increasing sea surface temperature. The relationship between the number of Wolf Sunspot and the anomalies of sea surface temperature was very closer after the late of 1980s than those before the early of 1980s in Korean waters.

HVDC 시스템의 수냉식 냉각 시스템 (Water-Cooling System of HVDC System)

  • 김찬기
    • 전력전자학회논문지
    • /
    • 제4권3호
    • /
    • pp.257-267
    • /
    • 1999
  • 본 논문은 대용량 컨버터의 수냉식 방열 시스템에 관한 내용을 담고 있다. 본 논문은 수냉식 방열 시스템의 이론적 근거와 모델링을 제시하고 전력용 반도체(싸이리스터)의 열량 계산을 수학적인 모델링에 근거하여 제시하였으며 실제로 우리나라에 설치되어 있는 제주-해남 HVDC 시스템에 적용하여 타당성을 검증하였다.

  • PDF

비닐하우스 지역의 지하수 양수에 따른 지하수-하천수 상호 유동 변화 분석 (Change of Groundwater-Streamflow Interaction according to Groundwater ion in a Green House Land)

  • 김남원;이정우;정일문;김창환
    • 한국수자원학회논문집
    • /
    • 제45권10호
    • /
    • pp.1051-1067
    • /
    • 2012
  • 겨울철 작물재배를 위해서 비닐하우스 보온을 위한 수막시설의 이용이 늘어나고 있어 과다한 지하수 이용에 따른 수위 강하 및 하천수 감소를 유발하고 있다. 따라서 수막시설재배 지역에서의 지하수 양수가 지하수 대수층과 연결된 하천에 어떠한 영향을 미치는 지를 정량적으로 평가해야 할 필요가 있다. 본 연구에서는 경기도 이천시 신둔면 수하리 일대 수막시설재배지역에 지하수위와 온도를 계측하기 위한 지하수 관측공을 제내지와 제외지에 설치하고 관측 결과를 분석하여 지하수 양수에 따른 하천-지하수 상호유동계의 변화를 평가하였다. 연구대상지역은 수위와 수온 관측 결과, 수막시설재배기간 동안 지하수 양수의 영향으로 하천수가 지하수계로 유입되는 손실하천의 양상을 나타내었다. 하천바닥층에 대해 침윤계 실험을 통해서 유도한 수두차와 침윤량간의 관계에 자동관측된 수위자료를 대입하여 하천과 지하수계 상호간 유동량의 연속적인 변화를 산정한 결과 수막시설재배가 한창인 2월말에는 지하수 이용량의 약 16% 만큼의 하천수가 감소하는 것으로 분석되었다.

고온에서 폴리프로필렌섬유와 비정질강섬유를 보강한 150MPa급 초고강도 콘크리트의 수증기 압력특성 (The water vapor pressure property of 150MPa level ultra high strength concrete reinforced with polypropylene fiber and amorphous steel fiber at high temperature)

  • 서동균;김규용;이상규;황의철;유하민;남정수
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2020년도 봄 학술논문 발표대회
    • /
    • pp.132-133
    • /
    • 2020
  • The aim of this study is to evaluate the combination effect of amorphous steel fiber and polypropylene fiber on spalling of the 150MPa level ultra high strength concrete. Considering spalling has a great relationship with water vapor pressure, this paper is focusing on water vapor pressure. The test specimens were heated accordance with ISO-834 Standard Curve using electric heating furnace, the depth of 10mm water vapor pressure formation was tend to get faster and spalling damage become severe when the mixing proportion of amorphous steel fiber increase. When using ultra high strength concrete reinforced with amorphous steel fiber, further research about proper mixing proportion of polypropylene fiber.

  • PDF

THM 형성 영향인자에 의한 THM 농도예측 및 고도정수처리 공정에의 적용 (The Predictions of THM Concentration by Influencing Factors on the THM Formation and Applications in Advanced Drinking Water Treatment Process)

  • 임정아;윤정효;박선호;김동윤
    • 상하수도학회지
    • /
    • 제11권4호
    • /
    • pp.126-132
    • /
    • 1997
  • Trihalomethanes (THMs) are formed during the chlorination of waters containing precusors compounds, most commonly humic substances, changes in pH, TOC, temperature, precusor source and concentration chlorine dosage, bromide level and reaction time directly influence trihalomethane formation potential (THMFP) and kinetics. A standard THMFP experiment was conducted for each water under the following conditions ; $20^{\circ}C$, pH 7.4, reaction time of 48hr, TOC 5.7mgC/L. A series of kinetic experiments was conducted for each water to provide THM formation under varying conditions of reaction time, pH, temperature and TOC, chlorine dosage. The resultant mutiple parameter powre function predicts a THM which allows direct calculation of THM, is $[THM]=0.00039(pH-2.81)[TOC][Cl_2]^{0.321}\;t^{0.266}\;T^{0.286}$ Characteristics of raw water in advanced drinking water treatment pilot plant were, TOC levels ran from 4.42~6.84mgC/L, pH 7.2~7.8, temperature $7.0{\sim}18.4^{\circ}C$, UV-254 absorbance $0.057{\sim}0.85cm^{-1}$, THM levels ranged from 0.031~0.049mgC/L.

  • PDF

통계기법을 활용한 충적층내 지하수-지표수 연계 특성 해석 (Understanding of Surface Water-Groundwater Connectivity in an Alluvial Plain using Statistical Methods)

  • 김규범;손영철;이승현;정안철;차은지;고민정
    • 지질공학
    • /
    • 제22권2호
    • /
    • pp.207-221
    • /
    • 2012
  • 낙동강 하류지역 주변 충적층 지역내 설치 운영중인 27개의 지하수 관측정의 시계열 자료를 활용하여 지표수와 지하수의 연계 특성 평가를 위한 통계적 분석을 수행하였다. 지하수위의 변화는 하천수위의 변화와 교차상관계수가 0.601로서 연관성이 높은 것으로 분석되었으며, 이는 강우와의 교차상관계수 0.125보다 매우 높다. 지하수위 시계열 자료에 대한 주성분 분석 결과, 연구지역내 지하수위는 2개의 그룹으로 분류된다. 이중에서 그룹 A에 속하는 하천에 인접한 관측정에서의 수위 변화는 하천수와 유사한 변동을 보이며 호우시의 지하수위 상승량도 상대적으로 크게 나타났다. 홍수 발생에 대한 지하수 기여에 대한 추가적 이해를 위해서는 지하수위 변동 특성을 기반으로 지구화학 분석 및 온도 계측 등이 추가적으로 수행될 필요가 있다.

하천-충적대수층계의 강변여과수를 열원으로 이용하는 지하수 열펌프 시스템의 계절별 입구온도와 효율성 평가 (Seasonal Variations of EWT and COP of GWHP System Using the Bank Infilterated Water from Stream-Alluvial Aquifer System)

  • 한찬;전재수;윤운상;한혁상;한정상
    • 한국지열·수열에너지학회논문집
    • /
    • 제3권2호
    • /
    • pp.39-51
    • /
    • 2007
  • Unconsolidated and permeable alluvial deposit composed of sand and gravel is distributed along the fluvial plain at the Iryong study area. Previous studies on the area show that a single alluvial well can produce at least 1,650m3d-1 of bank infilterated shallow groundwater(BIGW) from the deposit. This study is aimed to evaluate and simulate the influence that seasonal variation of water levels and temperatures of the river have an effect on those of BIGW under the pumping condition and also to compare seasonal variation of COPs when indirectly pumped BIGW or directly pumped surface water are used for a water to water heat pump system as an heat source and sink using 3 D flow and heat transport model of Feflow. The result shows that the magnitude influenced to water level of BIGW by fluctuation of river water level in summer and winter is about 48% and 75% of Nakdong river water level separately. Seasonal change of river water temperature is about $23.7^{\circ}C$, on other hand that of BIGW is only $3.8^{\circ}C$. The seasonal temperatures of BIGW are ranged from minimum $14.5^{\circ}C$ in cold winter(January) and maximum $18.3^{\circ}C$ in hot summer(July). It stands for that BIGW is a good source of heat energy for heating and cooling system owing to maintaining quite similar temperature($16^{\circ}C$) of background shallow groundwater. Average COPh in winter time and COPc in summer time of BIGW and surface water are estimated about 3.95, 3.5, and about 6.16 and 4.81 respectively. It clearly indicates that coefficient of performance of heat pump system using BIGW are higher than 12.9% in winter time and 28.1% in summer time in comparision with those of surface water.

  • PDF

4층 준지균 수치모형에 관한 연구 (A Study on the 4-level quasi-geostropic numerical model)

  • 이우진;이천우
    • 물과 미래
    • /
    • 제17권3호
    • /
    • pp.211-219
    • /
    • 1984
  • A 4-level baroclinic numerical model is designed by using the vorticity equation and Omega equation. Block-Cyclic-Reduction method is applied to the solution of the Helmholtz defferential equation, which is proved to be better than the Relaxation method from the composite viewpoint of accuracy, stability and economy. It was investigated whether the model explains the physical process influenced by voricity and temperature advection. It was also examined if the model atmosphere describes the general circulation. This examination is similar to Phillips(1956). The result of this numerical experiment shows that the model explains qualitatively the Quasi-Geostrophic theory for the development of Baroclinic wave, as throughly described in Holton(1972).

  • PDF

상수원 수질관리를 위한 분변오염 지표세균에 관한 연구 (A study on Investigation of Fecal Contamination Indicator Bacteria for Management of Source Water Quality)

  • 장현정;이용욱
    • 한국환경보건학회지
    • /
    • 제29권1호
    • /
    • pp.19-27
    • /
    • 2003
  • Coliforms is currently being used as the standard of environmental water qualify to evaluate the level of source water quality especially condition of fecal contamination. However, not properly applied to water quality management. So in this study, in addition to Coliforms, fecal contamination indicator bacteria turk at Feral Coliforms(FC), E. coli, Fecal streptococci(FS), Clostridium and environmental parameters related with it's distribution were investigated on a monthly basis in 6 water intakes of Han River. The mean of BOD, DO, SS and pH, benchmarks of source water management were maintained the second grade of environmental water quality standard applied to Han River but Coliforms exceeded it. Distribution of Coliforms ranged from 1.0×10¹ to 2.7 10/sup 5/ CFU/ml, FC ranged from ND to 5.3×10¹ CFU/ml, E. coli ranged from ND to 9.2×10¹ CFU/ml, FS ranged from ND to 2.5×10¹CFU/ml, they were steepy rise on July and August in common when rainfalls was heavy and water temperature was high, but Clostridium perfringens ranged from 1.7×10¹to 1.7×10¹CFU/ml not fluctuate by month. Statistical analysis of sampling data showed that most significant correlations occurred among FC and Coliforms(r = 0.840), E. coli(r = 0.792), FS(r = 0.687) and environmental parameters(temperature, turbidity, SS, rotor were all r > 0.60) while no significant correlation was observed between ammonia generally recognized fecal contamination indicator and bacteria. Identification of the coliforms showed that Enterobacter, Klebsiella, Citrobacter were comprised of 32%, 24%, 16% respectively, and E. coli were 7% of it. while E. coli was made up 85.9% of FC. The mean value of FC/Coliforms ratio, 5.2(0.1-42) were higher in Amsa, Guui than Jayang. Fecal coliforms, as those are able to reflect more particularly the extent of the fecal contamination, were considered useful in deciding the level of water treatment while monitoring the fecal contamination from the source of water supply. Therefore, it is expected that the water quality is going to be managed more efficiently by using fecal coliforms supplementarily to total coliforms which are current standard item of water-quality environment.

Theoretical and Experimental Considerations of Thermal Humidity Characteristics

  • Choi, Seok-Weon;Cho, Ju-Hyeong;Seo, Hee-Jun;Lee, Sang-Seol
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제3권1호
    • /
    • pp.9-18
    • /
    • 2002
  • Thermal humidity characteristics were considered theoretically and experimentally. A Simply well-fitted correlation of a saturated vapor pressure-temperature curve of water was introduced based on Antoine equation to make theoretical prediction of relative humidity according to temperature variation. Characteristics of dew point were also examined theoretically and its relation with temperature and humidity was evaluated. The exact mass of water vapor in a specified humidity and temperature condition was estimated to provide useful insight into the idea about how much amount of water corresponds to a specified humidity and temperature condition in a confined system. A simple but well-fitting model of dehumidification process was introduced to anticipate the trend of relative humidity level during GN2(gaseous nitrogen) purge process in a humidity chamber. Well-suitedness of this model was also verified by comparison with experimental data. The overall appearance and specification of two thermal humidity chambers were introduced which were used to perform various thermal humidity tests in order to yield useful data necessary to support validity of theoretical models.