• 제목/요약/키워드: water evaporation phenomenon

검색결과 37건 처리시간 0.023초

연령과 과제상황에 따른 물의 증발현상에 대한 아동의 액체보존개념 (Liquid Conservation Concept In The Water Evaporation Phenomenon According To The Age and Task-Situations)

  • 김은영
    • 한국생활과학회지
    • /
    • 제22권1호
    • /
    • pp.17-27
    • /
    • 2013
  • The purpose of this study is to investigate children's liquid conservation concept according to their ages and task-situations in the water evaporation phenomenon. Thirty from each 4-, 6- and 8-year-old age groups (total of 90 subjects) were selected for this study. The subjects were recruited from two day-care centers, a kindergarten, and an elementary school, in Seoul. Statistical methods used for data analysis were frequencies, percentiles, means, standard deviations and repeated measures ANOVA. As a result, there was a significant difference in children's liquid conservation concept in the evaporation of water according to their ages and task-situations. 8-year-old children showed levels of cognition than 4- and 6-year-olds. Children showed higher levels of cognition in the task of drying than in the task of water level changes.

계면활성제를 첨가한 액적의 증발냉각 (Evaporation Cooling of a Droplet containing a Surfactant)

  • 유갑종;방창훈;김현우
    • 대한기계학회논문집B
    • /
    • 제27권4호
    • /
    • pp.424-431
    • /
    • 2003
  • The evaporation cooling phenomenon of a droplet containing a surfactant on a heated surface has been studied experimentally. The two kinds of heater modules made of brass and Teflon$^{TM}$ were tested to investigate the cooling characteristics of droplet. Solutions of water containing Sodium Lauryl Sulfate(0 ppm, 100 ppm, 1000 ppm) were tested in the experiments. The results showed that the contact angle decrease as the concentration of surfactant increases. The tendency did not very with different heated solid materials. As initial temperature of the heated surface becomes high, time averaged heat flux increases and evaporation time decreases with the denser concentration of surfactant. Therefore, water with denser concentration of surfactant could be effective to cool flammable materials. However, the effect of surfactant becomes low as the material temperature is higher than the boiling temperature of water.

고온조건에서 콘크리트 부재의 온도전이 (Beat Transfer Analysis of Concrete Members under High Temperature)

  • 이태규;김혜욱
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2009년도 춘계학술대회 논문집
    • /
    • pp.1536-1541
    • /
    • 2009
  • When water inside the concrete member evaporates by high temperature, the evaporation heat which absorbs surrounding temperature occurs. The rate of increment of the internal temperature in concrete is reduced due to the evaporation heat in spite of continuously increasing external temperature. In this paper, the prediction method of internal temperature of high strength concrete members considering the evaporation heat under the high temperature is presented. Finite element method is employed to facilitate thermal analysis for any position of member. And the thermal characteristics models of high strength concrete affected by high temperature are proposed. To demonstrate the validity of this numerical procedure, the prediction by the proposed algorithm is compared with the test results of other researchers. The proposed algorithm shows a good agreement with the experimental results including the phenomenon that temperature is lost by the evaporation heat.

  • PDF

고온 하에서 기화열을 고려한 철근콘크리트 부재의 온도해석 (Heat Transfer Analysis of Concrete Members Considering Evaporation Heat under High Temperature)

  • 이태규
    • 대한토목학회논문집
    • /
    • 제29권4A호
    • /
    • pp.355-363
    • /
    • 2009
  • 고온으로 인하여 콘크리트 내부의 수분이 증발할 경우 주변의 온도를 흡수하는 기화열이 발생하게 된다. 이에 따라 콘크리트의 내부온도는 외부의 온도가 지속적으로 증가함에도 불구하고 증가율이 둔화되는 현상이 나타나게 된다. 본 논문은 콘크리트 부재의 고온 하에서의 기화열을 고려한 내부의 온도변화를 예측하고자 하는 것으로 부재 내부의 임의의 위치에서의 온도를 산정하기 위하여 유한요소방식을 적용하였다. 또한 콘크리트의 고온에서의 열적 특성치에 대해서도 모델식을 제시하였다. 이러한 해석기법의 정확성을 검증하기 위하여 여러 다른 연구자들에 의한 실험 데이터와 비교하였으며, 그 결과 기화열로 인하여 온도가 소실되는 현상을 포함한 전반적인 부재 내부의 온도분포 거동이 실제 실험데이터와 거의 유사하게 나타나는 것으로 확인되었다.

고온하에서 철근콘크리트부재의 온도해석 (Thermal Analysis of Reinforced Concrete Members at High Temperature)

  • 이태규
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 추계학술대회 논문집
    • /
    • pp.1102-1105
    • /
    • 2008
  • In this paper, the prediction method of internal temperature for high strength concrete members at high temperature is presented. Finite element method is employed to facilitate thermal analysis for any position of member. In case of water evaporates inside the concrete member by high temperature, the evaporation heat that absorb surrounding temperature is occurred. This effect of the evaporation heat is applied. And the model equations of the material characteristics of high strength concrete by high temperature are proposed. To demonstrate the validity of this numerical procedure, the prediction by the proposed algorithm is compared with the test results of other researchers. The proposed algorithm is good agreement with experimental results including the phenomenon that temperature by the evaporation heat is lost.

  • PDF

디젤 배기관에 분사된 우레아 수용액의 분무 거동 및 유동 특성에 관한 연구 (Numerical Investigation of the Spray Behavior and Flow Characteristics of Urea-Water Solution Injected into Diesel Exhaust Pipe)

  • 안태현;김만영
    • 대한기계학회논문집B
    • /
    • 제38권1호
    • /
    • pp.41-48
    • /
    • 2014
  • Urea-SCR 시스템은 주로 열해리와 증발시간의 부족으로 인해 발생하는 암모니아 슬립 현상과 관련된 몇 가지 문제점들을 가지고 있으며, 이러한 문제점들은 분사된 요소수용액의 불균일한 분포를 초래한다. 따라서 본 연구에서는, 배기가스와 요소수용액 사이의 증발 및 혼합특성을 강화시키기 위해 인젝터 장착 각도 그리고 믹서의 장착 및 설치 각도와 같은 다양한 매개변수들을 바꾸며 전산해석 연구를 수행하였다. 그 결과, 이와 같은 매개변수들이 배기가스와 요소수용액의 증발 및 혼합특성에 상당한 영향을 미친다는 것을 알 수 있었으며, 이 매개변수들의 최적화가 요구된다. 또한, 본 논문은 Urea-SCR 분사 시스템의 DeNOx 성능을 증가시키고 암모니아 슬립을 감소시키기 위한 최적 설계 시 유용한 기준을 제안할 것이다.

낙동강 중류에서 하천 증발이 안개에 미치는 영향 (The Influence of Evaporation from a Stream on Fog Events in the Middle Nakdong River)

  • 박준상;김규랑;강미선;김백조
    • 한국지구과학회지
    • /
    • 제38권6호
    • /
    • pp.395-404
    • /
    • 2017
  • 본 연구에서는 구미에 위치한 낙동강에서 발생한 안개를 분류하였고 안개 발생 전후의 기상특성을 분석하였다. 안개는 2013년부터 2015년까지 시정계를 이용하여 관측되었다. 안개는 총 74회 발생하였고 대부분 증기안개로 분류되었다. 관측된 증기 안개는 내륙에서 발생한 안개보다 지속시간이 길게 나타났는데 이는 지형적 특징으로 인해 야간 증발이 다른 지역보다 강하게 나타났기 때문이다. 안개 지속시간에 대한 하천 증발 효과를 분석하기 위해 Penman-Monteith(Penman법)와 Bulk aerodynamic (Bulk법) 방법을 사용하여 증발량을 추정하였다. 이 중 Bulk법은 실제 수면에서 측정한 증발량과 유사하게 나타났다. 따라서 Bulk법이 실제 수면 증발량 추정에 적합한 방법임을 확인할 수 있었다. Bulk법으로 추정한 증발량은 안개 비발생일 보다 안개 발생일에 06 LST와 07 LST에 더 높게 나타났다. 안개 발생일에 하천의 증발은 대기에 증발잠열 에너지를 공급하고 안개 내부의 난류를 유지하는 에너지원으로 작용한다. 이와 같은 결과는 안개내부의 풍속, 기온, 그리고 난류운동에너지의 증가를 통해 확인하였다.

태양열 이용 냉난방 공조시스템중 재생기의 최적 재생면 구조에 관한 연구 (Research on an Optimal Trickling Surface of the Regenerator in a Solar Air-conditioning System)

  • 김보철;최광환;금종수
    • 태양에너지
    • /
    • 제18권3호
    • /
    • pp.185-195
    • /
    • 1998
  • 본 연구는 태양열을 이용한 냉난방 공조시스템 개발 중 작동매체인 저농도의 염화리튬(lithium chloride) 용액을 고농도로 변환시키는 재생기의 최적 재생면을 파악하는 데 그 목적이 있다. 염화리튬 용액은 점성이 강하기 때문에 재생기의 상부로부터 하부로 유하될 때 편류(Channeling)현상을 발생하게 된다. 이 편류현상은 재생기에서의 열 및 물질전달을 방해하여 재생량을 감소시킨다. 결국 재생기의 성능, 나아가서는 태양열 이용 냉난방 공조시스템 전체의 성능이 염화리튬용액을 얼마나 균일하게 유하할 수 있는 가에 달렸다고 해도 과언은 아니다. 따라서 본 연구에서는 재생면의 다양한 형태와 구조를 고안해서 실제로 재생면을 제작하여 재생면의 최적 구조를 규명하였다. 실험을 위하여 가로 50cm, 세로 50cm 크기인 간이 재생기를 직접 제작하여 항온항습실에서 실험을 행하였다. 그 결과 평판 위에 높이 4.5mm 폭 10mm의 계단형 구조를 갖는 재생면에서 최대의 재생량을 얻을 수 있었다.

  • PDF

Mitigating the Urban Heat Island Phenomenon Using a Water-Retentive Artificial Turf System

  • Tebakari, Taichi;Maruyama, Tatsuya;Inui, Masahiro
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2010년도 학술발표회
    • /
    • pp.91-100
    • /
    • 2010
  • To investigate the thermal properties of a water-retentive artificial turf system (W-ATS), we estimated hydrologic parameters including thermal conductivity, heat capacity, and surface albedo for both the W-ATS and natural grass. We used a model experiment to measure surface temperature and evaporation for both the W-ATS and natural grass. We found that the W-ATS had lower thermal conductivity than natural grass did, and it was difficult for the W-ATS to convey radiant heat to the ground. Compared to natural grass, the W-ATS also had lower heat capacity, which contributed to its larger variation in surface temperature: the W-ATS had higher surface temperatures during daytime and lower surface temperatures during nighttime. The albedo of the W-ATS was one-quarter that of natural grass, and reflected shortwave radiation from the W-ATS surface was lower than that from the surface of natural grass. These results indicate that the W-ATS caused the soil temperature to increase. Furthermore, evaporation from the W-ATS was one-quarter the value of evapotranspiration from natural grass.

  • PDF

배플에 의한 개방챔버 내부 유동의 영향에 관한 연구 (A Study on Effects of the Fluid Flow Inner the Open Chamber by Baffle)

  • 노병수;최주열;정하균;최상범
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제39권3호
    • /
    • pp.255-260
    • /
    • 2015
  • 플래시증발현상은 개방챔버 내의 온도, 압력, 수위 그리고 배플 등에 영향을 받는다. 이 연구에서 PIV 실험은 최적의 배플 위치와 높이에 대한 개방챔버 내의 유동특성을 확실하게 시행하였다. 배플은 개방챔버 내의 재순환 흐름, 수력 도약 그리고 유동특성에 상당한 영향을 주었다. 그리고 레이놀즈수의 영향은 미미하였다. 최적의 배플높이는 h/H=1.5였고, 최적의 배플위치는 개방챔버 내부 입구로부터 x/H=1.5부근 이었다.