• 제목/요약/키워드: water environmental management

검색결과 2,961건 처리시간 0.033초

다목적 최적화기법을 활용한 상수도 공급계통 잔류염소농도 최적운영 모델 개발 (Development of optimization model for booster chlorination in water supply system using multi-objective optimization method)

  • 김기범;서지원;형진석;김태현;최태호;구자용
    • 상하수도학회지
    • /
    • 제34권5호
    • /
    • pp.311-321
    • /
    • 2020
  • In this study, a model to optimize residual chlorine concentrations in a water supply system was developed using a multi-objective genetic algorithm. Moreover, to quantify the effects of optimized residual chlorine concentration management and to consider customer service requirements, this study developed indices to quantify the spatial and temporal distributions of residual chlorine concentration. Based on the results, the most economical operational method to manage booster chlorination was derived, which would supply water that satisfies the service level required by consumers, as well as the cost-effectiveness and operation requirements relevant to the service providers. A simulation model was then created based on an actual water supply system (i.e., the Multi-regional Water Supply W in Korea). Simulated optimizations were successful, evidencing that it is possible to meet the residual chlorine concentration demanded by consumers at a low cost.

GIS를 이용한 상수원 보호를 위한 수변구역 지정에 관한 연구 (The Delineation of Water-Pollutant Buffering Zone for Sustaining Better Drinking Water Quality Using a GIS)

  • 김계현;윤호석;권우석
    • 환경영향평가
    • /
    • 제9권3호
    • /
    • pp.239-248
    • /
    • 2000
  • The aggravating water quality from the expansion of industrialization along with increasing population lead to develop more intensive physical measures to secure better drinking water quality. This study was mainly initiated to establish a water-pollutant buffering zone for the upper stream basin of Paldang--the major source area of drinking water for the metropolitan Seoul and suburban areas with a population more than 13 million. Two different criteria were considered in determining the buffering distance from the edge of the streamflow : 1km-width buffer zone for the special protection area which has been strictly controlled by the conventional laws for the protection of drinking water supply, and 500m-width buffer zone for the rest of the area. To delineate the exact boundaries of the water-pollutant buffering zone, GIS database was created integrating topography, hydrography, cadastral, and other related layers. The newly designated water-pollutant buffering zone would contribute to improve the water quality in a long term along with the conservation of the wet land. More study, however, should be made within the water-pollutant buffering zone such as the detailed survey of the pollutants, vegetation, and ecosystem for more effective management of the buffering zone.

  • PDF

생태계 모델을 이용한 울산만의 하계 수질관리 (Summer Water Quality Management by Ecological Modelling in Ulsan Bay)

  • 박성은;홍석진;이원찬;정래홍;조윤식;김형철;김동명
    • 해양환경안전학회지
    • /
    • 제16권1호
    • /
    • pp.1-9
    • /
    • 2010
  • 울산만의 육상기인 오염부하에 대한 해역수질의 응답특성을 조사하고 만내 수질관리에 활용하기 위하여 해양생태계모델링 연구를 수행하였다. 생태계모텔에 의해 계산된 울산만의 수질은 만 내측에서 COD 농도 2.8mg/L로 해양수질 III등급 수준으로 나타났다. 계산결과 울산만 전체 해역의 수질을 II등급으로 개선하기 위해서는 육상부하를 약 30% 이상 삭감해야 하며, COD 농도 1.0mg/L이하의 수질이 되기 위해서는 전체 육상부하의 70% 이상을 삭감해야 하는 것으로 나타났다. 해역수질 II등급을 유지하기 위하여 삭감해야 할 오염부하량은 약 3,083kgCOD/day, 이 때의 환경용량은 약 7,193kgCOD/day로 계산되었다. 태화강 하구역은 식물플랑크톤 대증식(Bloom)이 상습적으로 발생하는 해역이므로 식물플랑크톤에 의한 자생유기물 부하를 감소시키기 위해서는 유가물 삭감 이외에도 영양염의 제어가 필요한 것으로 나타났다.

홍제천 정비를 위한 하천유지유량 확보 및 수질개선 방안 연구 (Study on the Management of Minimum Low Flow and Water Quality of Hongjechun)

  • 황병기;호종광;오경석
    • 환경영향평가
    • /
    • 제14권1호
    • /
    • pp.37-46
    • /
    • 2005
  • In this study, field surveys were performed for 12 stations in main stream of Hongjechun and 3 stations in 2 tributaries, respectively, in order to find out dried reaches of the stream, and to examine the water quality of the stream, and to suggest methods to improve the stream concerned into eco-stream. In the results of water quality in stream, however distinct difference for seasonal variation of the water quality was not found, the water quality of winter was relatively better than that of other seasons. Annual mean concentration of BOD was 6.5mg/L in the upper reach, 11.8mg/L in the middle reach, 15.3mg/L in the lower reach of main stream, and total mean was 12.5mg/L, while the BOD concentration was 3.6mg/L in the upper reach, and was 9.6mg/L in the low reach of Gukichun, the tributary. Based on flow examination, the level of water depth was so low and the flow can not be traveled downstream in the reach between ST-9 and ST-10 for low water season, whereas it was observed that the flow was traveling except the dry season even the water level was lower than that of adjacent stations.

Derivation of Threshold Values for Groundwater in Romania, in order to Distinguish Point & Diffuse Pollution from Natural Background Levels

  • Radu, E.;Balaet, Ruxandra;Vliegenthart, F.;Schipper, P.
    • Environmental Engineering Research
    • /
    • 제15권2호
    • /
    • pp.85-91
    • /
    • 2010
  • Romania aims to adopt and implement the European Union's legislation, also including that for the field of water management. Like other countries, groundwater in Romania is locally polluted from point sources, such as leaking landfills, as well as from diffuse pollution sources, include fertilizers, pesticides and leakages from sewers, in urbanized areas. Diffuse pollution can also occur indirectly, by over-exploitation of groundwater wells, resulting in salt water intrusion, as well as from mining and exploitation of mineral aggregates. Romania has quite an intensive monitoring scheme to measure groundwater quality in phreatic and confined aquifers. The purpose of the work resumed in this paper was to derive natural background levels (NBL) for groundwater in order to distinguish the natural elevated concentrations of some substances (natural phenomena) from point and diffuse pollution (anthropogenic phenomena). Based on these NBLs, threshold values (TV) for groundwater will be set according to the requirements of the European Water Framework Directive and the related Groundwater Directive. This paper describes the results of a study for the derivation of NBL and TV in a pilot Groundwater Body. Also, the process and draft results for extrapolating this work for all Romanian groundwater bodies is explained, as well as points for future consideration with respect to monitoring and management.

매립장 침출수 주요 수질항목에 대한 장기 영향요소 (Long Term Affecting Factors on Major Water Quality Items of Landfill Leachate)

  • 천승규;김민혁;원종철
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제26권1호
    • /
    • pp.24-33
    • /
    • 2021
  • Analysis of long term affecting factors on water quality items of gas emission form (BOD, COD) and leachate emission form (T-N, non-bio-degradable COD (NBDCOD)) was performed for the SUDOKWON 1st Landfill Site (LS1) and 2nd Landfill Site (LS2). As landfill gas was generated, BOD and COD decreased from 6,887 and 20,025 mg/L in 1993 to 49.5 and 670.2 mg/L in 2019, respectively. TN and NBDCOD increased with waste decomposition but gradually decreased after landfill closure because of the precipitation infiltration effect. Due to the drastic decline of carbon in the leachate, the BOD/TN ratios of LS1 and LS2 declined from 13.0 and 17.0 during early stage of the landfill to 0.07 and 0.16 in 2019, respectively; LS2 and NBDCOD/COD increased from 0.25 to 0.65 during the same period. These conditions caused carbon deficiency in denitrification treatment and a chemical post-treatment request for NBDCOD. The different behaviors of gas emission and leachate emission items suggest the necessity of different strategic approaches in the long term perspective.

Sustainable Management of Irrigation Water Withdrawal in Major River Basins by Implementing the Irrigation Module of Community Land Model

  • Manas Ranjan Panda;Yeonjoo Kim
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2023년도 학술발표회
    • /
    • pp.185-185
    • /
    • 2023
  • Agricultural water demand is considered as the major sector of water withdrawal due to irrigation. The majority part of the global agricultural field depends on various irrigation techniques. Therefore, a timely and sufficient supply of water is the most important requirement for agriculture. Irrigation is implemented in different ways in various land surface models, it can be modeled empirically based on observed irrigation rates or by calculating water supply and demand. Certain models can also calculate the irrigation demand as per the soil water deficit. In these implementations, irrigation is typically applied uniformly over the irrigated land regardless of crop types or irrigation techniques. Whereas, the latest version of Community Land Model (CLM) in the Community Terrestrial Systems Model (CTSM) uses a global distribution map of irrigation with 64 crop functional types (CFTs) to simulate the irrigation water demand. It can estimate irrigation water withdrawal from different sources and the amount or the areas irrigated with different irrigation techniques. Hence, we set up the model for the simulation period of 16 years from 2000 to 2015 to analyze the global irrigation demand at a spatial resolution of 1.9° × 2.5°. The simulated irrigation water demand is evaluated with the available observation data from FAO AQUASTAT database at the country scale. With the evaluated model, this study aims to suggest new sustainable scenarios for the ratios of irrigation water withdrawal, high depending on the withdrawal sources e.g. surface water and groundwater. With such scenarios, the CFT maps are considered as the determining factor for selecting the areas where the crop pattern can be altered for a sustainable irrigation water management depending on the available withdrawal sources. Overall, our study demonstrate that the scenarios for the future sustainable water resources management in terms of irrigation water withdrawal from the both the surface water and groundwater sources may overcome the excessive stress on exploiting the groundwater in major river basins globally.

  • PDF

전산모형 및 공간정보시스템을 결합한 지하환경관리시스템의 개발 및 적용 (A Subsurface Environment Management System Combining Computational Model and Spatial Information System)

  • 김준현;한영한
    • 환경영향평가
    • /
    • 제10권2호
    • /
    • pp.99-108
    • /
    • 2001
  • This study was performed to develop an information processing system for the sound conservation of soil and groundwater resources. The system contains numerical models and geographic information systems for underground flow and contamination. Multidimensional Finite Element Model for Subsurface Environment (MFEMSE) was invented to analyze underground flow and pollution problems of water and gas phases. Newly developed and conventional models (MODFLOW, MOC3D, MT3D, PMPATH, PEST, UCODE) were integrated with GIS (ArcView) for the construction of an integrated information management system of subsurface environment. This system was applied to the management of three mineral water companies located in clean high mountain basin. Desirable management criteria and operational strategies were suggested using this system. The system was constructed to be applied for the broad sense of decision supporting tools in related topics of this study, so that it can be used not only for the prevention regulations, but also for clean up projects.

  • PDF

Flood Risk Management for Weirs: Integrated Application of Artificial Intelligence and RESCON Modelling for Maintaining Reservoir Safety

  • Idrees, Muhammad Bilal;Kim, Dongwook;Lee, Jin-Young;Kim, Tae-Woong
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2020년도 학술발표회
    • /
    • pp.167-167
    • /
    • 2020
  • Annual sediment deposition in reservoirs behind weirs poses flood risk, while its accurate prediction remains a challenge. Sediment management by hydraulic flushing is an effective method to maintain reservoir storage. In this study, an integrated approach to predict sediment inflow and sediment flushing simulation in reservoirs is presented. The annual sediment inflow prediction was carried out with Artificial Neural Networks (ANN) modelling. RESCON model was applied for quantification of sediment flushing feasibility criteria. The integrated approach was applied on Sangju Weir and also on estuary of Nakdong River (NREB). The mean annual sediment inflow predicted at Sangju Weir and NREB was 400,000 ㎥ and 170,000 ㎥, respectively. The sediment characteristics gathered were used to setup RESCON model and sediment balance ratio (SBR) and long term capacity ratio (LTCR) were used as flushing efficiency indicators. For Sangju Weir, the flushing discharge, Qf = 140 ㎥/s with a drawdown of 5 m, and flushing duration, Tf = 10 days was necessary for efficient flushing. At NREB site, the parameters for efficient flushing were Qf = 80 ㎥/s, Tf = 5 days, N = 1, Elf = 2.24 m. The hydraulic flushing was concluded feasible for sediment management at both Sangju Weir and NREB.

  • PDF

식생분포에 따른 하도의 통수능 검토를 위한 3차원 모형의 적용 (Application of Three-Dimensional Model to Evaluate Stream Discharge Capacity due to Vegetation)

  • 노준우;이진영;안기홍
    • 환경영향평가
    • /
    • 제20권1호
    • /
    • pp.37-48
    • /
    • 2011
  • Recently, the social and environmental functions of nature river are important due to the increase of expectation for river restoration. So it should be considered the effect of vegetation affecting the conveyance capacity and hydraulic resistance. However, it has not yet proposed a objective standard and modeling method to estimate the effect of conveyance capacity according to vegetaion distribution in the watercourse such as water level or velocity. Therefore, this study simulates the variations of water level and velocity using 3-dimensional hydrodynamic model, EFDC, to consider a conveyance capacity in downstream of the Soyang Reservoir. The simulation results were validated using statistical index such as F-test and T-test. As results, the water level rises about 0.01 to 0.47m and velocity difference are about -0.95m/s to 0.23m/s.