• 제목/요약/키워드: water environmental management

검색결과 2,961건 처리시간 0.034초

수도사업자의 장래 재정계획과 연계한 상수도시설의 최적 개량계획 수립 모델 개발 연구 (A Study on the Development of Optimal Renewal Planning Model in Water Supply Facilities Connected to Future Financial Plan of Water Providers)

  • 임상현;신휘수;서지원;김기범;구자용
    • 상하수도학회지
    • /
    • 제31권2호
    • /
    • pp.149-159
    • /
    • 2017
  • It is considered necessary to renewal a considerable number of water supply facilities in Korea because they began to be intensively buried in the period of rapid economic growth. Accordingly, local water providers are required to take measures against this situation, but they have currently been caught in a vicious circle of the lack of budget spent in renewing water supply facilities because county-based small-scale local water supply cannot afford to cover annual expenditures with their revenues from water rates. Therefore, this study developed an optimal renewal planning model capable of achieving a balance of financial revenue and expenditure in local water supply using nonlinear programming and furthermore of minimizing the total cost incurred during the analysis. To this end, this study selected the water supply area located in County Y as a research area to build the financial revenue and expenditure and used Solver function provided by Microsoft Excel to use nonlinear programming. As a result, this study developed an optimal renewal planning model minimizing incurred costs in consideration of 6 items in the financial revenue and expenditure. The optimal renewal plan was modeled according to the available annual budget. As a result, this study proposed SICD, a scenario to minimize total costs from the perspective of water suppliers, and SITS, a scenario to minimize the increase in water rates from the perspective of consumers. It can be said that the method proposed in this study is the core of the optimal financial and renewal plans as a final stage of asset management for water supply facilities. Therefore, it is considered possible for local water providers to use the method proposed in this study according to circumstances for the asset management of water supply facilities.

NTrend 1.0에 의한 낙동강 수질 장기변동 추세분석 (Long-Term Water Quality Trend Analysis with NTrend 1.0 Program in Nakdong River)

  • 유재정;신석호;윤영삼;송재기
    • 한국물환경학회지
    • /
    • 제26권6호
    • /
    • pp.895-902
    • /
    • 2010
  • The effect of seasonality on water quality variation is very significant. Generally, it reduce the power of the trend extraction. A parametric time-series model was used for detecting trends in historic constituent concentration data. The effect of seasonality is able to remove from time series decomposition technique. According to such statistic methode, long-term water quality trend analysis system (NTrend 1.0) was developed by Nakdong River Water Environmental Research Center. The trend analysis of BOD variation was conducted with NTrend 1.0 at Goreong and Moolkum site in Nakdong river to show the effect of water quality management action plan. Power test of trend extraction was tried each case of 'deseasonalized and deannulized' data and 'deseasonalized' data. Analysis period was from 1989 to 2006, and it's period was divided again three times, 1989~1993, 1994~1999 and 2000~2006 according to action plan period. The BOD trend was downward in Goreong site during three times and it's trend slope was very steep, and upward in Moolkum during 1989~1993, but it was turned downward during 1994~1999 and 2000~2006. It was revealed that it's very effective to reduce the concentration of BOD by water quality management action plan in that watershed. The result of power test was shown that it is high for trend extraction power in case of 'deseasonalized' data.

Marine Ecosystem Response to Nutrient Input Reduction in Jinhae Bay, South Korea

  • Oh, Hyun-Taik;Lee, Won-Chan;Koo, Jun-Ho;Park, Sung-Eun;Hong, Sok-Jin;Jung, Rae-Hong;Park, Jong-Soo
    • 한국환경과학회지
    • /
    • 제15권9호
    • /
    • pp.819-827
    • /
    • 2006
  • We study on the dynamic interaction with a simulated physical-biological coupled model response to nutrient reduction scenario in Jinhae Bay. According to the low relative errors, high regression coefficients of COD and DIN, and realistic distribution in comparison to the observation, our coupled model could be applicable for assessing the marine ecosystem response to nutrient input reduction in Jinhae Bay. Due to the new construction and expansion of sewage treatment plant from our government, we reduce 50% nutrient inputs near Masan Bay and sewage treatment plant. COD achieves Level II in Korea standard of the water quality from the middle of the Masan Bay to all around Jinhae Bay except the inner Masan Bay remaining at Level III. When our experiment reduces 50% nutrient inputs near Masan Bay and Dukdong sewage treatment plant simultaneously, COD decreases to about 0.1-1.2 mg/L $(128^{\circ}30'{\sim}128^{\circ}40'\;E,\;35^{\circ}05'{\sim}35^{\circ}11'\;N)$. The COD from the middle of the Masan Bay to Jinhae Bay achieves Level II.

석문호 유역 오염물질 배출특성 분석 및 수질모델링에 기초한 수질개선방안 연구 (Water Quality Improvement Plans based on the Analysis of Pollutant Discharge Characteristics and Water Quality Modelling of Seokmun Reservoir Watershed)

  • 최무진;정우혁;최재훈;김영일
    • 대한환경공학회지
    • /
    • 제39권10호
    • /
    • pp.581-590
    • /
    • 2017
  • 석문호 수질을 가장 효율적으로 개선하기 위한 최적의 방안을 마련하기 위해 본 연구에서는 지류하천의 수질 및 유량조사, 퇴적물 조사, 오염원 조사, 하천그룹화를 통한 중점관리 대상유역 선정을 포함한 다양한 분석을 수행하였다. 석문호 유역의 주요 지류하천은 대부분 BOD농도는 낮은 반면 COD농도는 높은 경향을 보였으며, 역천, 당진천, 시곡천, 백석천, 진관소하천, 장항소하천 등은 수질항목에 관계없이 수질농도가 높은 경향을 보였다. 석문호 유역 내 오염원은 생활계, 축산계 및 산업계가 대부분으로 지역에 따라 다양하게 분포하는 것으로 조사되었다. 석문호 수질개선을 위해 중점관리 대상하천으로 선정된 당진천, 역천, 백석천, 장항소하천 유역 내 위치하고 있는 오염원의 우선적인 저감이 필요한 것으로 판단된다. 석문호 수질개선을 위한 다양한 시나리오별 수질개선효과를 수질모델을 이용하여 정량적으로 평가한 결과, 유역 내 오염물질 배출량 관리를 위해 공공하수처리시설을 신설 및 증설만 하여도 호소 수질 V등급을 만족하는 것으로 나타났다.

부영양화된 해양환경의 수질개선을 위한 해양생태계모델링의 적용 ; 한국의 진해만 (Application of ecosystem modeling for the assessment of water quality in an eutrophic marine environment; Jinhae Bay)

  • 이원찬;박성은;홍석진;오현택;정래홍;구준호
    • 해양환경안전학회:학술대회논문집
    • /
    • 해양환경안전학회 2006년도 추계학술발표회
    • /
    • pp.217-219
    • /
    • 2006
  • This study focused an water quality response to land-based pollution loads and the appropriate pollutant load reduction in Chinhae Bay using an eco-hydrodynamic model. Land-based discharge foam urban areas, industrial complex and sewage treatment plant was the greatest contributor to cause red-tide blooms and summer hypoxia. Tidal currents velocity af the ebb tide was about 10 cm/s stronger than that of the flood tide. A residual current was simulated to. have a slightly complicated pattern with ranging from 0.1 to. 2.7 cm/s. In Masan Bay, pollutant materials cannot flaw from the inner to the outer bay easily because af residual currents flaw southward at surface and northward at the bottom. The simulation results of COD distribution showedhigh concentrations aver 3 mg/L in the inner part of Masan Bay related pollutant discharge, and charge, and lower levels less than 1.5mg/L in the central part of Chinhae Bay. For improvement water quality in Chinhae Bay, it is necessary to reduce the organic and inorganic loads from paint sources by mare than 50% and ameliorate severe polluted sediment.

  • PDF

수질오염총량관리계획 수립을 위한 유달부하량 추정방법 연구 (A Study on Estimated Pollutant Delivery Load for the Basic Plan of TPLC)

  • 황하선;이한필;안기홍;박지형;김용석;이성준
    • 한국물환경학회지
    • /
    • 제32권4호
    • /
    • pp.375-383
    • /
    • 2016
  • Total Pollution Load Control (TPLC) calculates and manages the allowable pollutant load that is discharged from the watershed, which can meet the water quality target. Delivery Ratio (DR) is generally used for predicting the variation of pollutant mass balance between the pollutants discharged from the watershed and a certain point in the stream, and it is very important for estimation of accurate allowable pollutant load. The concept of DR in TPLC is different from prevalent DR, because DR in TPLC includes both the discharge of pollutants from the watershed and the delivery mechanism. Therefore, DR in TPLC should be estimated by using a proper and unified methodology. The appropriate method and equation for estimation of DR in TPLC was developed through the review of various methodologies, and the applicability of the equation was evaluated in a study area (Geumho A). Determination coefficients (R2) of regression were shown to be relatively high (BOD 0.71~0.87, T-N 0.86~0.90, T-P 0.62~0.69). Applicability of the developed methodology and equations was evaluated as appropriate for TPLC, and it is suggested.

Evaluation of Water Quality Characteristics and Ecosystem Health of Yongpung Reservoir, Korea

  • Lim, Dohun;Lee, Yoonjin;Kim, Kyung
    • 한국환경보건학회지
    • /
    • 제45권1호
    • /
    • pp.42-53
    • /
    • 2019
  • Objectives: The Yongpung reservoir in Korea is a crucial facility that supplies water to farms in its surrounding $2km^2$ area. However, its water quality is not suited to the needs of current residents who wish for the availability of environmentally friendly agricultural products and desire to use the waterfront area. The aim of this research was to evaluate the reservoir's fish and benthic macroinvertebrate distributions and determine its water quality and the heavy metal content in its sediment. This basic data can be used to establish environmentally protective plans for the Yongpung reservoir. Methods: Six sites were selected for analysis in this investigation. Three points (YP-1, YP-2, and YP-3) were evaluated for water quality and metal content in sediments; they were located upstream, midstream, and downstream of the reservoir. Samplings of the fish and benthic macroinvertebrate populations were performed at three other sites: St. 1, St. 2, and St. 3. Results: Based on chemical oxygen demand (COD) and total nitrogen (T-N) data, the quality of the Yongpung reservoir water corresponds to Class VI (very poor) according to Korea's lake environmental standards. The lead levels measured in the sediment at the midstream and downstream points of the reservoir were 76.7 and 72.7 mg/kg, respectively, while 8 orders, 15 families, and 16 species of benthic macroinvertebrates were identified in the reservoir. The ecological score of the benthic macroinvertebrate community (ESB) was between 8 and 23, denoting poor to very poor environmental conditions. Further, 4 families and 7 species of fish were identified in the reservoir, with Cyprinidae accounting for 94.3% of all observed freshwater fish. Conclusion: Based on these findings, we conclude that management plans, including the removal of lead from the sediment, are necessary to improve the quality of the agricultural water in this reservoir. The T. japonica, which cover almost 30% of the water area, must also be removed.

Development of a Decision Support System for Turbid Water Management through Joint Dam Operation

  • Kim, Jeong-Kon;Ko, Ick-Hwan;Yoo, Yang-Soo
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2007년도 학술발표회 논문집
    • /
    • pp.31-39
    • /
    • 2007
  • In this study we developed a turbidity management system to support the operation for effective turbid water management. The decision-making system includes various models for prediction of turbid water inflow, effective reservoir operation using the selective withdrawal facility, analysis of turbid water discharge in the downstream. The system is supported by the intensive monitoring devices installed in the upstream rivers, reservoirs, and downstream rivers. SWAT and HSPF models were constructed to predict turbid water flows in the Imha and Andong catchments. CE-QUAL-W2 models were constructed for turbid water behavior prediction, and various analyses were conducted to examine the effects of the selective withdrawal operation for efficient high turbid water discharge, turbid water distribution under differing amount and locations of turbid water discharge. A 1-dimensional dynamic water quality model was built using Ko-Riv1 for simulation of turbidity propagation in the downstream of the reservoirs, and 2-dimensional models were developed to investigate the mixing phenomena of two waters discharged from the Andong and Imha reservoirs with different temperature and turbidity conditions during joint dam operation for reducing the impacts of turbid water.

  • PDF

상수원의 지속가능한 관리를 위한 합리적 의사결정 방향 (Reasonable Decision Making for Sustainable Water Supply Source Management)

  • 최지용
    • 한국물환경학회지
    • /
    • 제23권4호
    • /
    • pp.504-511
    • /
    • 2007
  • Built-out issue of copper processing appearing recently in the Paldang watershed is a critical problem to deteriorate the basic framework of national water management policy as well as to be simply a copper-related problem. Up to now, Korea government has invested hard and relevant upstream areas have been victimized readily in a variety of field to comply its goal of 'Safe Water Supply'. Because of the reason, the desirable water quality level of the Paldang watershed has been maintained regardless of its dense population. Paldang drinking water management policy is based on residents' understanding which is considered as a 'social capital'. The issue raised in the aspect of water quality management policy should be reviewed on the basis of the 'social capital' concept. One regarding semiconductor industry as a potential industry to export many products in 10 years insists that the industry not be a simple private business but be a prominent part for national competitiveness. There is no doubt about this opinion. However, a nation should support environmental right-to-life of its people prior to any other tasks. In other words, it is really risky to give up people's right due to economic benefits. Therefore, it should not happen to trade 'life', the dignity of man, with national competitiveness which is likely to be preferred in these days. In addition, coherent policy not to destroy 'social capital' promoting Paldang drinking water resource management policy should be maintained.

국내 농업용수의 유해중금속 수질권고기준 도출 (Derivation of Agricultural Water Quality Guidelines for Heavy Metals in Korea)

  • 안윤주;백용욱;이우미;윤춘경
    • 한국물환경학회지
    • /
    • 제24권5호
    • /
    • pp.533-536
    • /
    • 2008
  • Korean water quality guidelines for agricultural were derived to protect agricultural water uses according to the Canadian methodology. The adverse effect of heavy metals in agricultural water was of concern due to its persistence, bioaccumulation and ecotoxicity to crop plants. The ecotoxicity data of cadmium, copper, lead, and zinc were collected for the crops grown in Korea, and used to estimate the species maximum acceptable toxicant concentration (SMATC), which corresponds to the water quality guideline. Values of irrigation per year and soil bulk density were revised to reflect the Korean situation. The estimated guideline values for cadmium, copper, lead, and zinc were 0.01, 0.5, 0.1, and 1.0 mg/L, respectively. These values are in agreement with the agricultural water quality guidelines of foreign countries and current Korean water quality standard for the protection of public health. Current water quality standards in agricultural uses were for management of public water resource, and was not prepared to protect crop plants from contaminants. The results of this study will be a basis for the designation of Korean water quality guidelines for the protection of agricultural water uses in the future.