• Title/Summary/Keyword: water distribution system

Search Result 1,586, Processing Time 0.023 seconds

Response od Striped Puffer to the White Light (백색광에 대한 까치복의 반응)

  • 양용림
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.24 no.4
    • /
    • pp.144-149
    • /
    • 1988
  • The purpose of this study is to find the light intensity which induced maximum gathering rate and to observe the variation of the gathering rate both in daytime and tat night by using Striped puffer, Fugu xanthopterus (Temminck et Schlegel). An experimental tank(360L$\times$50W$\times$55H cm) was set up in a dark room. An illumination system was attached to the end of one side of the tank to control horizontal light intensity. Eight artificial light sources were prepared by combination of three light bulbs (10W, 60W, 100W) and eight filters. During the experiment water depth was maintained 50 cm level in the tank. The tank was marked into six longitudinal sections each being 60cm long to observe the distribution of fish. The fish were acclimatized in dark condition for 50 minutes prior to the main experiment. Upon turning on the light, the number of fish in each section was counted 60 times every 30 seconds, and the gathering rate was obtained from the average number of fish in each section. The light intensity inducing maximum gathering rate was 298.56 lux (188.44-444.96 lux) at daytime and 298.56 lux (188.44-444.96 lux) at night. The variation of the gathering rate of fish in illumination time was increasing trend fluctuately and did not show any distinctive difference between day and night.

  • PDF

Fish length dependence of acoustic target strength for 12 dominant fish species caught in the Korean waters at 75 kHz (한국 연근해에서 어획된 주요 12어종의 75 kHz에 대한 음향 반사 강도의 체장 의존성)

  • Lee, Dae-Jae
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.41 no.4
    • /
    • pp.296-305
    • /
    • 2005
  • Acoustic target strength (TS) of 12 commercially important fish species caught in the Korean waters had been investigated and their results were presented. Laboratory measurements of target strength on 12 dominant fish species were carried out at a frequencies of 75 kHz by single beam method under the controlled condition of the water tank with the 241 samples of dead and live fishes. The target strength pattern on individual fish of each species was measured as a function of tilt angle, ranging from $-45^{\circ}$ (head down aspect) to $45^{\circ}$ (head up aspect) in $0.2^{\circ}$ intervals, and the averaged target strength was estimated by assuming the tilt angle distribution as N ($-5.0^{\circ}$, $^15.0{\circ}$). The 75 to fish length relationship for each species was independently derived by a least - squares fitting procedure. Also, a linear regression analysis for all species was performed to reduce the data to a set of empirical equations showing the variation of target strength to fish length and fish species. An empirical model for fish target strength(TS, dB) averaged over the dorsal aspect of 158 fishes of 7 species and which spans the fish length(L, m) to wavelength(${\lambda}$, m) ratio between 6.2 and 21.3 was derived: TS: 27.03 Log(L)-7.7Log(${\kanbda}$)-17.21, ($r^2$=0.59).

Efficiency of wave absorption by the porous of "Taewoo" of Jeju in regular seaway (파랑 중 제주 "테우" 틈에 의한 파 흡수효과)

  • Lee, Chang-Heon;Choi, Chan-Moon;Ahn, Jang-Young;Cho, Il-Hyoung
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.49 no.2
    • /
    • pp.144-152
    • /
    • 2013
  • In an effort to find the optimum porous of Taewoo through the mathematical model 2 - dimensional tank water experiment among the approached to a problem related to ocean engineering, this study analyzed the porosity by dividing it into 9 cases. As the wave penetrates through the longitudinal porous of the Taewoo model, it was found that there is a wave energy loss because of the phenomenon of the separation of the porous due to the eddy. Looking into the general tendency based on the wave-height meter (probe) data, it was found that the shorter wavelength and higher frequency area, the more reflection coefficients increased, but in contrast, the longer wavelength and lower frequency area, the transmission coefficients showed the increasing trend and energy dissipation was in a similar way with reflection coefficients. In addition, it was found that the bigger the porosity was, the narrower distribution range of reflection coefficients was, and the more its average value decreased. On the other hand the transmission coefficients in direct opposition to reflection was found to show the wider range and the more gradual increase in the average value as porosity was the bigger around the average value. In contrast, energy dissipation rate was found to increase linearly as porosity increased the more around the porosity of 0.2518 but it decreased gradually around the peak point. Through the above results, it is judged that the porous of optimum in the longitudinal direction of the Taewoo model perforated plate was about 2.6cm because it was found that the porosity which produced the lowest reflection and transmission coefficient and the highest energy dissipation. As a result of comparing this to the case where there was no porosity at all, it showed the function of wave absorbing about 31.60%.

Part1 : Numerical Code Validation and Quantitative Analyses of Ice Accretion around Airfoils (Part1 : 익형 주위 결빙 예측 코드 검증 및 정량적 분석)

  • Son, Chan-Kyu;Oh, Se-Jong;Yee, Kwan-Jung
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.38 no.11
    • /
    • pp.1094-1104
    • /
    • 2010
  • In the previous studies, the validation of numerical codes has been conducted based on the qualitative comparison of predicted ice shapes with experiments, which poses a significant limit on the systematic analysis of ice shapes due to the variation of meteorological conditions. In response to this, the numerical code has been quantitatively validated against available experiment for the ice accretion on cylinders and airfoils in the present study. Ice shapes accumulated on the bodies are systematically investigated with respect to various icing parameters. To this end, maximum thickness, heading direction and ice thickness are quantified and expressed in the polar coordinate system for the comparison with other numerical results. By applying the quantitative analysis, similar shapes are intuitively distinguished. The developed numerical code underestimates the ice accretion area and the ice thickness of lower surface. In order to improve the accuracy, further accurate aerodynamic solver is required for the water droplet trajectories.

Phototaxis of Fish (3) - Response of Rock bream and Grass Puffer to the Colored lights - (어류의 주광성에 관한 연구 (3) - 어광의 돌돔과 복섬의 반응 -)

  • 양용림
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.16 no.1
    • /
    • pp.37-42
    • /
    • 1980
  • The purpose of the present study is to find the color induced maximum gathering rate and to observed'the trend of the - gathering rate by using two species of commercial fishes: rock bream, Oplegnathus fasciatus (Temminet et Schlegel) and 'grass puffer, Fugu niphobles (Jordan et Snyder). An experimental tank($360L{\times}50W{\times}55H cm$) was set up in a dark room. An illumination system was attached to the two end of tank to fix horizontal light intensity by co~bination c' one light bulb(20W) and four filters (red, blue, yellow, white) and the five regulating filters in order to fix light intensity. During the experiment water depth was maintained 50 cm lever in the tank. The tank was marked into six longitudinal sections each being 60 em long to observe the distribution of fish. The fish were acclimatized in dark condition for 40 minutes prior to the main experiment. Upon turning on the light, the number of fish in each section was counted 40 times every 30 seconds, and the gathering rates ,were obtain from the average number of fish in each secion. The color induced maximum gathering rate of rock bream appeared to be red, blue yellow and white color orderly.However, that of grass puffer appeared to be blue, white, yellow and red color orderly. Trend of the gathering rate in illumination time showed the remarkable fluctuation in the rock bream and little difference at the two color light sources. However, trend of the gathering rate in illumination time showed the little fluctuation in grass puffer and much difference at the two color light sources.

  • PDF

On the Safety and Performance Demonstration Tests of Prototype Gen-IV Sodium-Cooled Fast Reactor and Validation and Verification of Computational Codes

  • Kim, Jong-Bum;Jeong, Ji-Young;Lee, Tae-Ho;Kim, Sungkyun;Euh, Dong-Jin;Joo, Hyung-Kook
    • Nuclear Engineering and Technology
    • /
    • v.48 no.5
    • /
    • pp.1083-1095
    • /
    • 2016
  • The design of Prototype Gen-IV Sodium-Cooled Fast Reactor (PGSFR) has been developed and the validation and verification (V&V) activities to demonstrate the system performance and safety are in progress. In this paper, the current status of test activities is described briefly and significant results are discussed. The large-scale sodium thermal-hydraulic test program, Sodium Test Loop for Safety Simulation and Assessment-1 (STELLA-1), produced satisfactory results, which were used for the computer codes V&V, and the performance test results of the model pump in sodiumshowed good agreement with those in water. The second phase of the STELLA program with the integral effect tests facility, STELLA-2, is in the detailed design stage of the design process. The sodium thermal-hydraulic experiment loop for finned-tube sodium-to-air heat exchanger performance test, the intermediate heat exchanger test facility, and the test facility for the reactor flow distribution are underway. Flow characteristics test in subchannels of a wire-wrapped rod bundle has been carried out for safety analysis in the core and the dynamic characteristic test of upper internal structure has been performed for the seismic analysis model for the PGSFR. The performance tests for control rod assemblies (CRAs) have been conducted for control rod drive mechanism driving parts and drop tests of the CRA under scram condition were performed. Finally, three types of inspection sensors under development for the safe operation of the PGSFR were explained with significant results.

Physicochemical Characterization and Carcinoma Cell Interaction of Self-Organized Nanogels Prepared from Polysaccharide/Biotin Conjugates for Development of Anticancer Drug Carrier

  • Park Keun-Hong;Kang Dong-Min;Na Kun
    • Journal of Microbiology and Biotechnology
    • /
    • v.16 no.9
    • /
    • pp.1369-1376
    • /
    • 2006
  • Self-organized nanogels were prepared from pullulan/biotin conjugates (PU/Bio) for the development of an effective anticancer drug delivery system. The degree of biotin substitution was 11, 19, and 24 biotin groups per 100 anhydroglucose units of pullulan. The physicochemical properties of the nanogels (PU/Bio1, 2 and 3) in aqueous media were characterized by dynamic light scattering, transmission electron microscopy, and fluorescence spectroscopy. The mean diameter of all the samples was less than 300 nm with a unimodal size distribution. The critical aggregation concentrations (CACs) of the nanoparticles in distilled water were $2.8{\times}10^{-2},\;1.6{\times}10^{-2}$, and $0.7{\times}10^{-2}mg/ml$ for the PU/Bio1, 2, and 3, respectively. The aggregation behavior of the nanogels indicated that biotin can perform as a hydrophobic moiety. To observe the specific interaction with a hepatic carcinoma cell line (HepG2), the conjugates were labeled with rhodamine B isothiocyanate (RITC) and their intensities measured using a fluorescence microplate reader. The HepG2 cells treated with the fluorescence-labeled PU/Bio nanoparticles were strongly luminated compared with the control (pullulan). Confocal laser microscopy also confirmed internalization of the PU/Bio nanogels into the cancer cells. Such results demonstrated that the biotin in the conjugate acted as both a hydrophobic moiety for self-assembly and a tumor-targeting moiety for specific interaction with tumor cells. Consequently, PU/Bio nanogels would appear to be a useful drug carrier for the treatment of liver cancer.

Response of Marbled Sole to the White Lights (백색광에 대한 문치가자미의 반응)

  • YANG Yong-Rhim
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.19 no.6
    • /
    • pp.558-562
    • /
    • 1986
  • The purpose of this study is to find the light intensity which induces maximum gathering rate and to observe the variation of the gathering rate both in daytime and at night by using marbled sole, Limanda yokohamae (Gunther). An experimental tank ($360L{\times}50W{\times}55H\;cm$) was set up in a dark room. An illumination system was attached to the end of one side of the tank to control horizontal light intensity. Six artificial light sources were prepared by combination of two light bulbs (5W, 150W) and seven filters. During the experiment water depth was maintained 50 cm level in the tank. The tank was marked into six longitudinal sections each being 60 cm long to observe the distribution of fish. The fish were acclimatized in dark condition for 50 minutes prior to the main experiment. Upon turning on the light, the number of fish in each section was counted 40 times every 30 seconds, and the gathering rate was obtained from the average number of fish in each section. The light intensity inducing maximum gathering rate was 1.9 lux ($1.2{\sim}2.9\;lux$) in the daytime and 0.7 lux ($0.5{\sim}1.1\;lux$) at night. The variation of the gathering rate of fish in illumination time was small and comparatively fluctuated with stability.

  • PDF

Effect of Air Flow Rate on the Performance of Planar Solid Oxide Fuel Cell using CFD (평판형 고체산화물 연료전지의 CFD 성능해석에서 공기유량변화의 영향)

  • Kim, Danbi;Han, Kyoungho;Yoon, Do-Young
    • Journal of the Korean Electrochemical Society
    • /
    • v.18 no.4
    • /
    • pp.172-181
    • /
    • 2015
  • Solid Oxide Fuel Cells (SOFC) continue to be among the most promising alternative energy devices. This paper addresses i-V characteristics of SOFC with a focus on air flow rate along the planar anode electrodes. To address this, detailed Butler-Volmer kinetics are implemented in a general-purpose CFD code FLUENT. The numerical results were validated against experimental data from the literature showing excellent match with i-V polarization data ranging 1V-0.4V. Numerical calculations of fuel cell operation under different flow rare conditions were performed in three-dimensional geometries. Results are presented in terms of concentration distribution of hydrogen, oxygen, and water. The simulations and results indicate that advanced CFD with UDF(User-Defined Function) of Butler-Volmer kinetics can be used to identify the conditions leading to air flow rate and specific surface area and guide development of operating conditions and improve the fuel cell system performance.

Dispersion, Speciation and Adsorption Treatment of Heavy Metals in the Vicinity of the Shi-Heung Cu-Pb-Zn Mine (시흥 Cu-Pb-Zn 광산 주변에서의 중금속원소들의 분산 및 존재형태와 흡착처리)

  • Hwang, Ho Song;Chon, Hyo Taek
    • Economic and Environmental Geology
    • /
    • v.28 no.5
    • /
    • pp.455-467
    • /
    • 1995
  • In order to investigate the dispersion patterns and speciations of Cu, Pb, Zn and Cd in soils, stream sediments and stream waters, geochemical studies of soil, stream sediment and stream water samples collected in the vicinity of the Shi-Heung Cu-Pb-Zn mine was carried out Cation exchange capacity measurement, size analysis, X-ray diffraction analysis and batch test were performed to select applicable soil for adsorption treatment The average content of Cu, Pb, Zn and Cd in soils collected from tailings and ore dressing plant is 1084 ppm, 2292 ppm, 3512 ppm and 29.2 ppm, respectively, and therefore, tailings and ore dressing plant site may be the major contamination sources in this study area. The mean content of Cu, Pb, Zn and Cd in stream sediments is extremely high up to 794 ppm, 1633 ppm, 2946 ppm and 25.2 ppm, respectively. Tailing particles and heavy metal ions are dispersed along the tributary system. Results from the sequential extraction analysis indicate; (1) most of Cu is bound to organic matters and sulphides, (2) fraction of Pb is mainly bound to Fe and Mn oxides. Most of Zn is largely bound to Fe and Mn oxides and residual fraction. Ion exchangeable fraction of Cd is relatively higher than those of Cu, Pb and Zn. Batch test on soils collected from the kaolinite and/or pyrophyllite mines and from the control areas was carried out to select an applicable soil samples for adsorption treatment The sample, S10, collected from the control area 2 (clay content 33.2%) shows the highest $K_d$ (distribution coefficient). Organic content in soils and several clay minerals shows relatively good correlation with $K_d$. It means that applicable soils for adsorption treatment of heavy metals show high organic and clay content.

  • PDF