• Title/Summary/Keyword: water chemical characteristics

Search Result 2,152, Processing Time 0.031 seconds

Water Quality Change Characteristics of Treated Water in Distribution System of Water Treatment Plant of Jeiu City (제주시 정수장 처리수의 급수과정별 수질변화 특성)

  • Han, Kyung-Yong;Lee, Min-Gyu;Chung, Ho-Jin;Kam, Sang-Kyu
    • Journal of Environmental Science International
    • /
    • v.16 no.1
    • /
    • pp.81-94
    • /
    • 2007
  • The purpose of this work is to investigate the water quality change characteristics of treated water in water distribution systems of Water Treatment Plants (WTPs) of Jeju City. For this, the raw water, treated water and tap water that did not pass (named as not pass-tap water) and passed through the water storage tank (named as pass-tap water) were sampled and analyzed monthly from September 2001 to August 2002, for four (W, S, B and O) WTPs except for D WTP (where treated water is not supplied continuously) among WTPs of Jeju City. The concentrations of $NO_3^-$ and $Cl^-$ of treated water in distribution systems changed little, but changed seasonally, which is considered to be based on the seasonal variation of the quality of raw water. The pH of treated water changed little in distribution systems for S WTP, but for the other WTPs, the pH of not pass-tap water was similar to that of treated water and the pH of pass-tap water was higher than that of treated water. The turbidity of treated water in distribution systems changed little except for W2 of W WTP and S4 and S5 of S WTP, where it was higher than that of each treated water. The residual chlorine concentrations between treated water and not pass-tap water changed little, but those between treated water and pass-tap water changed greatly, based on the its long residence time in water storage tank and so its reaction with organic matter, etc or its evaporation. The concentrations of TTHMs (total trihalomethanes) and $CHCl_3$ that induce cancers in water distribution systems of these WTPs, were much lower than their water quality criteria and those in other cities. The concentrations of TTHMs of treated water and not pass-tap water were similar, but concentrations of pass-tap water were 1.5 to 2.0 times higher than those of treated water and not pass-tap water, due to the reaction of residual chlorine and organic matter, etc, with the result of long residence time in water storage tank.

High Resistivity Characteristics of the Sinter Dust Generated from the Steel Plant

  • Lee, Jae-Keun;Hyun, Ok-Chun;Lee, Jung-Eun;Park, Sang-Deok
    • Journal of Mechanical Science and Technology
    • /
    • v.15 no.5
    • /
    • pp.630-638
    • /
    • 2001
  • The electrical resistivity of sinter dusts generated from the steel industry and coal fly ash from the coal power plant has been investigated using the high voltage conductivity cell based on JIS B 9915 as a function of temperature and water content. Dust characterization such as the chemical composition, size distribution, atomic concentration, and surface structure has been conducted. Major constituents of sinter dusts were Fe$_2$O$_3$(40∼74.5%), CaO (6.4∼8.2%), SiO$_2$(4.1∼6.0%), and unburned carbon (7.0∼14.7%), while the coal fly ash consisted of mainly SiO$_2$(51.4%), Al$_2$O$_3$(24.1%), and Fe$_2$O$_3$(10.5%). Size distributions of the sinter dusts were bi-modal in shape and the mass median diameters (MMD) were in the range of 24.7∼137㎛, whereas the coal fly ash also displayed bi-modal distribution and the MMD of the coal fly ash was 35.71㎛. Factors affecting resistivity of dusts were chemical composition, moisture content, particle size, gas temperature, and surface structure of dust. The resistivity of sinter dusts was so high as 10(sup)15 ohm$.$cm at 150$\^{C}$ that sinter dust would not precipitate well. The resistivity of the coal fly ash was measured 1012 ohm$.$cm at about 150$\^{C}$. Increased water contents of the ambient air lowered the dust resistivity because current conduction was more activated for absorption of water vapor on the surface layer of the dust.

  • PDF

A Study on Chemical Composition and Formation of Dewfall in Miryang Area (밀양지역 이슬의 생성과 화학적 조성에 관한 연구)

  • Jeon, Byung-Il;Hwang, Yong-Sik
    • Journal of Environmental Impact Assessment
    • /
    • v.15 no.3
    • /
    • pp.227-235
    • /
    • 2006
  • In order to understand chemical characteristics and formation of dewfall in Miryang area, we analysed monthly distribution of dewfall, and investigated its chemical composition of dewfall. The modified teflon plate ($1m{\times}1m$) was used qualitatively to collect water soluble components at Miryang weather station from August 2002 to April 2003. Dewfall amount during the sampling periods (37 day) collected 5.28 mm. The behaviors of water soluble ions in dewfall showed the highest concentration ($555.8{\mu}eq/l$ for $Cl^-$, $338.6{\mu}eq/l$ for ${NO_3}^-$, $1118.2{\mu}eq/l$ for ${SO_4}^{2-}$, $262.7{\mu}eq/l$ for ${NH_4}^+$, $1341.0{\mu}eq/l$ for ${Ca_2}^+$, $177.8{\mu}eq/l$ for ${Mg_2}^+$, and $325.5{\mu}eq/l$ for $Na^+$) during the April, the lowest concentration ($243.6{\mu}eq/l$ for ${SO_4}^{2-}$, $39.3{\mu}eq/l$ for ${NH_4}^+$ and $456.2{\mu}eq/l$ for ${Ca_2}^+$) during the September. Monthly equivalent ratio of [${SO_4}^{2-}$]/[${NO_3}^-$] showed the highest value (6.45) during the March, the lowest value (1.86) during the September, and the mean value was 2.70.

Removal efficiency of various coagulants for Microcystis, Anabaena and Oscillatoria at different cell densities

  • Han, Joo Eun;Park, Soo Hyung;Yaqub, Muhammad;Yun, Sang Leen;Kim, Seog-ku;Lee, Wontae
    • Membrane and Water Treatment
    • /
    • v.13 no.1
    • /
    • pp.15-20
    • /
    • 2022
  • The continuous industrial growth increases the volume of pollutants discharged into the water, which induces Cyanobacteria in the receiving bodies. The removal of various cyanobacteria such as Microcystis, Anabaena, and Oscillatoria was explored to analyze their removal characteristics using different chemical and mineral coagulants. The chemical coagulants, including poly aluminium chloride (PACl), Alum, and mineral coagulants such as Loess and Illite, were tested to remove selected cyanobacteria. Results indicated that the removal rate increased with coagulant dosage regardless of the type of coagulant. The removal of selected cyanobacteria using chemical coagulant was found in the order: Microcystis > Anabaena > Oscillatoria. The PACl coagulant showed the most efficient removal rate for Microcystis, Anabaena, Oscillatoria. Removal rate of Microcystis conducted by PACl showed 92% at 100,000 cells/mL and 98.4% at 1,000,000 cells/mL whereas Illite showed lower 70% and Loess showed lower 50% in both 100,000 cells/mL and 1,000,000 cells/mL. The removal rate of Anabaena and Oscillatoria by PACl and Alum was higher 80%, while the other coagulants exhibited lower than 75% at 1,000,000 cells/mL. The removal rate of Oscillatoria by PACl was 80.1%, while the other coagulants exhibited lower than 70% at 1,000,000 cells/mL. Moreover, the mineral coagulants showed better removal efficiency at a higher concentration than low concentration during experiments. Therefore, removing cyanobacteria from water streams can be improved through coagulation by selecting a specific coagulant for a particular type of algae.

Physical and Chemical Characteristics of Sediments at Bam Islands in Seoul, Korea

  • Han, Mie-Hie;Kim, Jae-Geun
    • Journal of Ecology and Environment
    • /
    • v.29 no.4
    • /
    • pp.389-398
    • /
    • 2006
  • To examine sediment characteristics and find anthropogenic effects on riverine wetland ecosystems, paleoecological study was carried out at Bam islands in Seoul. Three hundred cm deep sediment cores were retrieved and dated with the lamination analysis method until 36 cm depth (1986). Sediments were divided into three zones based on the depth profiles of physico-chemical variables: below 160 cm depth (before 1968), between 160 and 40cm depths and above 40cm depth (after 1986). Physico-chemical characteristics were very variable between 160 and 40cm depths and this indicates unstable sedimentation environment. Even though heavy metal concentrations were relatively low, Cd and As contents have increased continuously. Dry mass accumulation rates during $1968{\sim}1986\;and\;1987{\sim}2003$ were 140 and $21\;kg\;m^{-2}\;yr^{-1}$, respectively. This was related to flooding intensity and duration. Bulk density, water content, loss on ignition, N, C, C/N ratio were very similar to other river delta but Ca, Na and K contents were 2 to 4 times higher than others. Heavy metal contents except Pb were lower or similar to those in other studied marshes in Korea. Heavy metal and Mg contents were correlated with each other and this suggests that the source of heavy metals be parent rock. From $^{13}C$ dating dates of organic materials in sediment, it is suggested that organic matter originated from the watershed and flooding intensity in the watershed might be responsible for the source of sediments. This study provides reference data for the comparison of sediment characteristics at islands in river and for the management of Bam islands.

Preparation of Ion Exchange Membranes for Fuel Cell Based on Crosslinked Poly(vinyl alcohol) with Poly(acrylic acid-co-maleic acid)

  • Kim, Dae-Sik;Park, Ho-Bum;Lee, Chang-Hyun;Lee, Young-Moo;Moon, Go-Young;Nam, Sang-Yong;Hwang, Ho-Sang;Yun, Tae-II;Rhim, Ji-Won
    • Macromolecular Research
    • /
    • v.13 no.4
    • /
    • pp.314-320
    • /
    • 2005
  • Crosslinked poly(vinyl alcohol) (PVA) membranes were prepared at various crosslinking temperatures using poly(acrylic acid-co-maleic acid) (PAM) containing different PAM contents. The thermal properties of these PVA/PAM membranes prepared at various reaction temperatures were characterized using differential scanning calorimetry (DSC). The proton conductivity and methanol permeability of PVA/PAM membranes were then investigated as PAM content was varied from 3 to 13 wt%. It was found that the proton and methanol transport were dependent on PAM content in their function both as crosslinking agent and as donor of hydrophilic -COOH groups. Both these properties decreased monotonously with increasing PAM concentration. The proton conductivities of these PVA/PAM membranes were in the range from $10^{-3}\;to\;10^{-2}S/cm$ and the methanol permeabilities from $10^{-7}\;to\;10^{-6}cm^{2}/sec$. In addition, the effect of operating temperature up to $80^{\circ}C$ on ion conductivity was examined for three selected membranes: 7, 9 and 11 wt% PAM membranes. Ion conductivity increased with increasing operating temperature and showed and S/cm at $80^{\circ}C$, respectively. The effects of crosslinking and ionomer group concentration were also examined in terms of water content, ion exchange capacity (IEC), and fixed ion concentration. In addition, the number of water molecules per ionomer site was calculated using both water contents and IEC values. With overall consideration for all the properties measured in this study, $7{\sim}9\;wt%$ PAM membrane prepared at $140^{\circ}C$ exhibited the best performance. These characteristics of PVA/PAM membranes are desirable in applications related to the direct methanol fuel cell (DMFC).

Contamination of Heavy Metals from Dongmyeong Au-Ag Mine Area (동명 금-은 광산 주변의 중금속 오염)

  • 이광춘;김세현;이승호;서용찬
    • Economic and Environmental Geology
    • /
    • v.36 no.1
    • /
    • pp.17-25
    • /
    • 2003
  • Researches were carried out to investigate the characteristics and concentration of heavy metal elements of stream water through Dongmyoung abandoned metal mine and soil adjacent to the mine. The pH range of water was 5.9∼7.1 that implies the water environment was acidic to neutral. The contents and distribution aspects of heavy metals in water samples varied with geochemical characteristics of element, but the concentration of heavy metals has the tendency of increase closer to the mine in general. The results of soil analysis show that total heavy metal concentration of agricultural soil near mine was far lower than those of ore tailing and dumping site. Therefore, the effects of the abandoned mine on stream water and agricultural products were supposed to be insignificant, particularly because the portion of absorbed carbonates and reducible fractions among total heavy metal concentration was relatively lower than the other. Since, however total heavy metal concentrations of mining site were relatively higher than those of adjacent region, there is a possibility of heavy metal difussion when the chemical environment of the site changes due to migration of surface and underground water. It is suggested that the preventive measures for water and soil pollution by the heavy metals would be considered around the region.

Adhesive characteristics of water-paint and silane adhesive mixture (수성페인트-실란접착제 혼합물의 접착특성)

  • HAN, Hyun Kak
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.8
    • /
    • pp.5721-5727
    • /
    • 2015
  • Paint must be resistant to the wear and tear of the atmosphere and should maintain its color and finish for a long time. The solvents of paints were organic solvent and water, common artificial source of VOCs(Volatile organic Solvent) include organic solvent. Using of organic solvent paint was decreased in the interior parts of automotive, exterior parts were still used organic solvent paint. Adhesive strength of water-paint was poor to compare with organic solvent paint and peeled off from the base materials, it was big quality problem. In this study, adhesive characteristics of water-paint and silane mixture was investigated. To improve adhesive strength of water-paint, it was necessary to mixing of adhesive material. Adhesive strength was measured using UTM(Universal Test Instrument) by ASTM D1002 and Peeling off condition was by ASTM D3359. Optimal mixing condition of water-paint and silane adhesive were $25^{\circ}C$, 500rpm, 20min., concentration of silane adhesive was 5 wt%.

Geochemical characteristics on the petrological groups of stream sediments and water in primary channels of the Jangheung area, Korea (장흥지역 1차수계 하상퇴적물의 지질집단별 지구화학적 특성과 하천수에 대한 연구)

  • 박영석;김종균;한민수;김용준;장우석;신성천
    • Economic and Environmental Geology
    • /
    • v.35 no.6
    • /
    • pp.509-521
    • /
    • 2002
  • The purpose of this study is to find out geochemical characteristics of stream sediments which are good indicator of geochemical hazard valuation and water in primary channels of the Jangheung area. We separated three groups which were granitoid area, granite gneiss area and tuffeous area by petrological properties. Physical and chemical characteristics of stream water such as temperature, pH, and EC were measured in the field between 1999 and 2001 and stream sediments samples were collected from April to May in 1999. For the chemical analysis of stream sediments samples, XRF, ICP-AES and NAA were used. The contents of the major elements had a similar contents in three groups and those of rare earth elements in granite gneiss area were lower value than those of other two groups. Zn and Cu were higher value than the other toxic elements. Through the enrichment factor and enrichment index features of the elements, we knew that $Fe_2O_3$, MgO, $TiO_2$, MnO and Eu, Yb of the tuffeous area samples and Co, Cr, Zn were enriched.

A Comparative Study on Adsorption Characteristics of Total Nitrogen and Phosphorous in Water Using Various Adsorbents (여러 흡착제를 이용한 총질소와 총인 흡착특성에 관한 비교연구)

  • Ryoo, Keon Sang;Choi, Jong-Ha
    • Journal of the Korean Chemical Society
    • /
    • v.56 no.6
    • /
    • pp.700-705
    • /
    • 2012
  • The present study is to explore the possibility of utilizing loess and fly ash as well as activated carbon for the adsorptive removal of T-N and T-P in water. Here, we investigated adsorption efficiency and Freundlich constants k and 1/n of each adsorbent. It was found that fly ash has not adsorptive capability for both T-N and T-P in water. Adsorption of T-N from water by loess has not occurred, but showed that adsorption efficiency for T-P reached approximately 57.5% at equilibrium time of 24 hr and room temperature. Activated carbon was shown to be an effective adsorbent for adsorption of T-N from water. Freundlich constant 1/n value of activated carbon represented that adsorptive capability of activated carbon is almost equivalent to loess.