• 제목/요약/키워드: water and wastewater management

검색결과 458건 처리시간 0.023초

공공하수도 관리대행 성과평가 지표별 가중치분석을 통한 우선순위에 대한 연구 (A study on the priorities through weight analysis for each index of performance evaluation of public sewage operation agency)

  • 위미경;박철휘
    • 상하수도학회지
    • /
    • 제34권6호
    • /
    • pp.495-502
    • /
    • 2020
  • The 37 indicators for performance evaluation of public sewage management agencies are divided into four major categories (agency manpower management ability, wastewater treatment plant operation and management, sludge and water reuse, service quality) in the first stage, and the necessity and score acquisition for the detailed indicators by each major category in the second stages. Priority was investigated through the Analytic Hierarchy Process (AHP) analysis technique for ease and relevance of company efforts. Also, based on the results of this analysis, integrated type weighting and relative importance were analyzed. As a result of the analysis, the weight and relative importance of the first stage classification were in the order of wastewater treatment plant operation and maintenance, operation agency manpower management ability, sludge and water reuse, and service quality. As a result of analyzing the weights and priorities of the detailed performance indicators in the second stage, it was found that operator's career years, the percentage of certification holding rate in operators, compliance with the effluent water quality standards, training times for operators, and efforts to manage hazardous chemicals were important. Some of the indicators of operation agency performance evaluation may include indicators in which the performance of the company's efforts is underestimated or overestimated. In order to improve this, it is necessary to give weights in consideration of the necessity of the indicator, the relevance of the company's efforts, and the ease of obtaining scores.

매립지내 환경에너지단지의 무방류 시스템 구축방안 (Construction Method of Zero Discharge System for Environmental Energy Complex in Landfill)

  • 천승규
    • 상하수도학회지
    • /
    • 제27권5호
    • /
    • pp.581-590
    • /
    • 2013
  • A research was performed for zero discharge system of waste water which is produced from energy recovery process of waste and biomass. Leachate and all kinds of waste water should be separated and integrated into three categories in addition to converting existing leachate treatment facility into waste water treatment facility as well as introducing a management system of reverse osmosis membrane facility and bioreactor landfill. Following these conditions to better water treatment process, it was likely to produce over 3,000 tons of low-grade recycling water and 2,000 tons of high-grade recycling water per day when zero discharge system of waste water is applied starting from 2016. Economical efficiency was also surveyed in total treatment fee. Present system costs 18,129 million won per year, and suggested zero discharge system would cost 15,789 million won per year.

지방중소도시의 누수관리방법에 대한 효율성 평가 (Efficiency evaluation of water leakage management methods in local small and medium cities)

  • 황진수;최태호;김기범;구자용
    • 상하수도학회지
    • /
    • 제35권2호
    • /
    • pp.121-133
    • /
    • 2021
  • This study set up the estimates of leakage management efficiency evaluation and leakage management goal that could be used in local water distribution networks efficiency business and modernization business. The data were analyzed using data envelopment analysis and multiple regression analysis. To this end, with leakage management input indices concerning leakage reduction activities (e.g., aged pipe replacement, water meter replacement, leakage restoration, and leakage detection) and leakage management calculation indices (e.g., the increase of revenue water ratio and the reduction of leakage ratio), the data on 22 K-water consignment local water supply systems were analyzed for the years from 2004 through 2018. Using the results of efficiency analysis by data envelopment analysis, the other DMUs (Decision Making Unit) benchmarked the DMU with the highest efficiency to maximize the leakage management efficiency for all DMUs. Through this, leakage management goal estimates were drawn with the input indices of four leakage reduction activities and calculation indices of the increase of revenue water ratio and the reduction of leakage ratio by multiple regression analysis for each group based on the revenue water ratio and leakage ratio. The correlation coefficients of the leakage management goal estimate for the criteria for the revenue water ratio amounted to 0.553 and 0.771. The correlation coefficients of the leakage management goal estimate for the criteria for leakage ratio were 0.397 and 0.865. Accordingly, we estimated the quantity and priority of four leakage reduction activities for the target leakage ratio and revenue water ratio.

상수도 관망에서의 경제적인 누수관리목표 산정 방안 연구 (A Study on Setting Methods of Economic Level of Leakage in Water Pipe Networks)

  • 황진수;최태호;이두진;구자용
    • 상하수도학회지
    • /
    • 제31권3호
    • /
    • pp.237-248
    • /
    • 2017
  • The estimation method of economical leakage management target utilized upon planning business for improvement of revenue water ratio in South Korea is presented and applicability of methods developed in this study is assessed through application on site. With a consideration of revenue water ratio in application target area, estimation method of long-term economical leakage management target is applied. Three leakage reduction methods such as replacement of residual aged pipe, leakage investigation and restoration and water pressure management are applied with a consideration of characteristics of site. Due to difficulty of obtaining data, analysis of cost/benefit by leakage reduction methods is performed by applying method of leakages estimation equation among statistical methods. As a result of application, revenue water ratio corresponding to long-term economical leakage management target is 91.6 %.

수돗물 위해요소 리스크 관리를 위한 물안전계획 적용 연구 (A study on the application of water safety plans for the hazard risk management of tap water)

  • 김진근;김두일
    • 상하수도학회지
    • /
    • 제33권4호
    • /
    • pp.259-268
    • /
    • 2019
  • One of the most effective methods to consistently ensure the safety of a tap water supply can be achieved by application of a comprehensive risk assessment and risk management approach for drinking water supply systems. This approach can be termed water safety plans(WSP) which recommended by WHO(world health organization) and IWA(international water association). For the introduction of WSP into Korea, 150 hazards were identified all steps in drinking water supply from catchment to consumer and risk assessment tool based on frequency and consequence of hazards were developed. Then, developed risk assessment tool by this research was implemented at a water treatment plant($Q=25,000m^3/d$) to verify its applicability, and several amendments were recommended; classification of water source should be changed from groundwater to stream to strengthen water quality monitoring contaminants and frequencies; installation of aquarium to monitor intrusion of toxic substances into raw water; relocation or new installation on-line water quality analyzers for efficient water quality monitoring; change of chlorination chemical from solid phase($Ca(OCl)_2$) to liquid phase(NaOCl) to improve soundness of chlorination. It was also meaningful to propose hazards and risk assessment tool appropriate for Korea drinking water supply systems through this research which has been inconsistent among water treatment authorities.

지류의 수질이 금호강 본류의 수질에 미치는 영향에 관한 연구 (The Effect of Branches on Kumho River's Water Quality)

  • 양득석;배헌균
    • 한국환경과학회지
    • /
    • 제21권10호
    • /
    • pp.1245-1253
    • /
    • 2012
  • In this study, how branches of Kumho River affect to the water quality on Kumho River was investigated. Water samples from six sampling points at Kumho River and three at each branch were taken from Dec. 2009 to Dec. 2011. As results, Namcheon affected BOD and T-P concentrations on Kumho River while Sincheon did only T-P concentrations. However, the water quality of Kumho River was improved because of Sincheon in terms of BOD and COD concentrations. This was the results from management of Sincheon wastewater treatment facility and Jisan wastewater treatment facility which might be the best example for managing wastewater treatment facilities. Dalsecheon would not affect the water quality of Kumho River although it had bad conditions of water quality because of lack of its water quantity comparing to Kumho River's.

윤충류를 활용한 하천 및 연안의 수질관리에 관한 연구 (A Study on the Water Quality Management Using the Rotifers)

  • 김정숙
    • 한국환경과학회지
    • /
    • 제16권2호
    • /
    • pp.227-232
    • /
    • 2007
  • Water pollution in enclosed water bodies such as lake and river has become a serious problem over the world. Domestic wastewater is responsible for more than 60 % pollution load in public water area in Korea. Effluent of the treated domestic wastewater at low removal level is abundantly fed rivers and lakes and thus be an serious cause of lake pollution. Therefore, effective implement of domestic wastewater treatment in basin of lake and river must be prepared. The septic tank is one of the effective domestic wastewater treatment equipment and used in individual treatment for a unit of household, The purpose of septic tank as biological treatment system is simultaneously to remove BOD, T-N, T-P and reduce turbidity from influent. Accordingly, the appropriate control of functional microorganisms is important subject for the establishment of stability and economy of the biological treatment method. Especially, microanimals as a high-ranked microorganisms of food-chain are important, because microanimals control the other microorganisms especially various bacteria and effect on function of treatment. Therefore, it is necessary that functional predator like rotifers are attached in wastewater treatment process. In this study, the methods for attachment high density the rotifer to and improvement of transparency in the effluence by a dense rotifer was examined using laboratory scale biological treatment reactor simulated septic tank and real one.

수자원 보전을 위한 유역통합관리 방안에 관한 연구(II) - 오십천 수계의 수질모델링 및 수질 예측 - (Study in the integrated watershade management for conservation of water resources (II) - Water quality modeling and simulation of Oship stream -)

  • 허인량;정의호;권재혁
    • 한국환경보건학회지
    • /
    • 제28권2호
    • /
    • pp.61-69
    • /
    • 2002
  • Oship stream is located nearby south eastern coasts. This study was performed to find out waters quality modeling and then to predict water quality of Oship stream. Based on survey data, BOD, T-N, T-P calibration and verification result were in good agreement with measured value within mean coefficient variance(MSE) value, which were 13.9%, 9.0%, 26.5% and 19.5%, 12.0%, 16.5%, respectively. Sectional water quality predictions of the main stream of Oship stream are executed on the basis of the following cases 1) with sewage treatment of Dogye-eup 2) reduction of mine wastewater treatment of 80% in th basin. As a result, BOD, T-P improvement rates at down stream of Oship stream, case 1) were appeared 12.2%, 22.2%, case 2) maximum sulfate ion and conductivity reduction removal rate of Oship stream were 58%, 68%. The main pollution sources of Oship-stream were almost domestic wastewater and mine wastewater discharged from Dogye-eup which located in uppers stream. The large effects will appear after the construction of Dogye sewage water treatment plant which remove the organic matter and nutrients in these sewage water. The waste water from mine can not easily to treat for characteristics of effluence and economic problems. However, to achieve the goal of water quality in Oship-stream water system, treatments of those are necessary.

수질오염 총량관리계획과정의 오염부하량 할당에 관한 연구 - 경기도 광주시를 사례로 - (A Study on the Allocation of Permissible Water Pollution Load in the Total Water Pollution Load Management Plan)

  • 김시헌;임재명
    • 환경영향평가
    • /
    • 제14권5호
    • /
    • pp.337-346
    • /
    • 2005
  • Pollution load allocation can likely be much controversial, which is essential to formulate the total water pollution load management plan. Existing rules(or guidances) in Korea, can provide no specific criteria for load allocation. Therefore, this paper studied(comprehensively) possible standards how or why to choose any particular allocation method, which was applied in the Gwangju City's load allocation for the satisfaction of set water quality goal. This load allocation is basically focused on the load reduction of domestic wastewater rather than industrial wastewater, because the land-use is strictly regulated and larger sources of pollution are few in the Gwangju City. This paper recommends the city to increase the capacity of sewage treatment plants, promote sewerage maintenance, and set higher effluent standards.