• 제목/요약/키워드: wastewater sampling

검색결과 99건 처리시간 0.023초

처리분구별 하수발생 특성 조사 - A시 O, M 처리분구 - (Investigating Wastewater Flow Characteristics - O and M Treatment Basins of A City -)

  • 황병기
    • 상하수도학회지
    • /
    • 제19권3호
    • /
    • pp.348-356
    • /
    • 2005
  • Water quality sampling surveys and continuous measurement of flow were conducted to identify wastewater flow characteristics for representative catchment of O and M treatment basins in A city. For HS-1 station representing commercial area, wastewater flow rises in the beginning of office-working hours, moves up and down within narrow range, and lasts till office-leaving hour, and falls gradually reflecting worker's returning home. However, in HS-2 station representing residential area, wastewater flow has two peaks, which are before office-going hour and after office-leaving hour. In residential area, the flow rate of weekends is higher than that of weekdays because it reflects population, being not contributed to generate wastewater during the working hours of weekdays, stay home and produce wastewater for weekends period. To determine the priority for rehabilitation of sewer system, infiltration rate was computed by dividing infiltration flow by mean diameter and total length of sewer, and HS-1 station ranked the first.

수질 특성(TSS) 파악을 통한 1차 침전지 성능 평가 (TSS 농도를 중심으로) (Evaluation of Primary Clarifier by Wastewater TSS Characterization)

  • 이병희
    • 상하수도학회지
    • /
    • 제23권3호
    • /
    • pp.363-369
    • /
    • 2009
  • In order to evaluate primary clarifier performance on TSS(Total Suspended solids) removal, four different sampling sets were collected as part of this study; (1) weekly test, (2) the diurnal sampling, (3) the settling velocity distribution sampling. Primary effluent TSS($TSS_{PE}$) and non settleable TSS($TSS_{NON}$) concentrations were averaged 160 and 75.5 mg/L, respectively. These data suggest approximately 85 mg/L TSS can be removed more. Average $TSS_{NON}$, $TSS_{PE}$, and Dispersed TSS(DTSS) concentrations(75.5, 160, and 104 mg/L, respectively) suggest that 28.5 mg/L of TSS difference attributable to poor flocculation, whereas 56 mg/L of TSS difference attributable to poor hydraulics within primary clarifier. In this study, equations for maximum TSS removal efficiency and effluent TSS concentration were suggested and compared with experimented data.

남양주시 하수발생특성 연구 (Study on Characteristics of Wastewater Flow for Namyangju City)

  • 황병기;이의상;김경원;손정은
    • 환경영향평가
    • /
    • 제12권2호
    • /
    • pp.73-86
    • /
    • 2003
  • In this study, we performed 8 times of water quality sampling and continuous measurement of flow to identify wastewater flow characteristics for wastewater treatment basins of Namyangju city. The field survey has been conducted 6 times in dry weather period and 2 times in wet weather period. Each survey conducted 24-hr water quality sampling in the interval of 2-hr. From the analysis of flow data and water quality data, the following conclusions can be drawn. For Namyangju-1 station, which represents residential and commercial mixed area, flow rises early in the morning before office-going hour and moves up and down within narrow range, and lasted after office-leaving hour, resulting from continuous commercial activity. In case of Namyangju-5 station representing community and Namyangju- 6 station representing residential area, the flow immediately falls down after rising early in the morning and later rises again at the office-leaving hour, and arrives at peak flows around late evening. In the analysis of wastewater characteristics for weekdays and weekends, without landuse types the flow rate of weekends is higher than that of weekdays because it reflects population, being not contributed to generate wastewater during the working hours of weekdays, stay home and produce wastewater for weekends period.

수도꼭지에서 미생물 검사 목적의 샘플링 방법 개선 연구 (Improvement of sampling method for bacteriological test in tap water)

  • 이은숙;이동식;이목영;이만호;한선희
    • 상하수도학회지
    • /
    • 제25권4호
    • /
    • pp.519-525
    • /
    • 2011
  • We studied on the effect of faucet cleanliness, faucet conditions (screen, mixing faucet), and flushing time for bacterial detection in tap water. As results, tap water should be left to run to waste for 2 to 3 minutes and if a questionable cleanliness is questionable, disinfect the faucet by using flaming or other methods before sampling. We proposed sampling method to decrease effect of factors associated with bacterial detection in tap water and contributed to be evaluated more accurate water quality.

상수도 관망 데이터의 사용목적에 관한 수집 주기 연구 (Study on the sampling rate for the purpose of use in water distribution network data)

  • 이경환;서정철;차헌주;송교신;최준모
    • 상하수도학회지
    • /
    • 제27권2호
    • /
    • pp.233-239
    • /
    • 2013
  • Sampling rate of Hydraulic pressure data, depending on the intended use of the water distribution system is an important factor. If sampling interval of hydraulic data is short, that will be more useful but it demand a lot of expense for maintenance. In this study, based on simulation of water distribution system 2 khz data, statistical techniques of student t distribution, non-exceedance probability using the optimal sampling rate for research.

경상북도내 주요 하폐수처리장 방류수의 미량유해물질 배출특성 (The Discharge Characteristic of Micropollutants in Effluents from Major Sewage and Wastewater Treatment Facilities in GyeongSangBukdo)

  • 서상욱;배헌균
    • 한국환경과학회지
    • /
    • 제20권6호
    • /
    • pp.673-678
    • /
    • 2011
  • Water samples from several wastewater treatment plants and two industry drains in Gyeongsangbukdo were investigated for concentration levels of micropollutants. Samples were taken totally four times from May to November of 2008 and tested for seven factors including pesticide, 1,4-Dioxane and Perchlorate which had been big issues for Nakdong river because of their contaminations. As results, 2,4-D, Alachlor, and BEHA were not detected while BEHP was detected at some sampling sites. 1,4-Dioxane and Perchlorate were also detected in wide ranges from several sampling sites. Therefore, continuous supervising and monitoring systems needed to be invested for proper management for micropollutants since those micropollutants could affect human health and aquatic system with low concentration levels.

낙동강 유역 일부 폐수처리장 방류수 및 공단배수로의 휘발성유기화합물(VOCs)의 분포현황 (The Detection of VOCs in Effluents from Several Wastewater Treatment Plants and Industry Drains in Nakdong River Basin)

  • 배헌균
    • 대한환경공학회지
    • /
    • 제34권4호
    • /
    • pp.254-259
    • /
    • 2012
  • 낙동강 유역 일부공단지역에 위치한 일곱 개소의 폐수처리장 및 두 개소의 공단배수로에서 휘발성유기화합물(Volatile Organic Compounds, VOCs)의 분포특성을 조사하였다. 시료는 2008년 5월부터 2008년 11월 사이 총 4회에 걸쳐 채취하였으며 총 17종의 VOCs를 분석하였다. 실험 결과, 8종의 VOCs가 일부 시료에서 검출이 되었고 검출농도는 종류와 시료채취 위치에 따라 달랐지만 모두 0.11 (Trichloroethylene)~5.81 (Toluene) ${\mu}g/L$ 의 범위인 것으로 확인되었다. VOCs는 미량으로도 인간의 건강이나 수중 생태계에 심각한 영향을 미칠 수 있으므로 이들 물질이 비록 미량의 수준을 보였으나 검출이 된 이상 이들 물질에 대한 적절한 관리대책이 강구되어야 할 것으로 사료되며 본 연구에서 이들 물질에 대한 관리방안을 제안하였다.

상수관망 데이터 수집의 최적 빈도 결정을 위한 방법론적 접근 (Methodology for determining optimal data sampling frequencies in water distribution systems)

  • 김현준;정은혜;황경엽
    • 상하수도학회지
    • /
    • 제37권6호
    • /
    • pp.383-394
    • /
    • 2023
  • Currently, there is no definitive regulation for the appropriate frequency of data sampling in water distribution networks, yet it plays a crucial role in the efficient operation of these systems. This study proposes a new methodology for determining the optimal frequency of data acquisition in water distribution networks. Based on the decomposition of signals using harmonic series, this methodology has been validated using actual data from water distribution networks. By analyzing 12 types of data collected from two points, it was demonstrated that utilizing the factors and cumulative periodograms of harmonic series enables similar accuracy at lower data acquisition frequencies compared to the original signals. Type your abstract here.

폐수의 악취측정을 위한 금속산화물 반도체 및 전기화학식 가스센서 어레이 특성 평가 (Evaluation of Metal Oxide Semiconductor and Electrochemical Gas Sensor Array Characterization for Measuring Wastewater Odor)

  • 임봉빈;이석준;김선태
    • 센서학회지
    • /
    • 제24권1호
    • /
    • pp.29-34
    • /
    • 2015
  • This study aimed to evaluate the characterization of a metal oxide semiconductor and electrochemical gas sensor array for measuring wastewater odor. The sensitivity of all gas sensors observed in sampling method by stripping was 6.7 to 20.6 times higher than that by no stripping, except sensor D (electrochemical gas sensor). The average reduction ratio of sensor signal as a function of initial dilution rate of wastewater was in the order of food plant > food waste reutilization facility > plating plant. The sensitivity of gas sensors was dependent on both the type of wastewater and the dilution rate. The sensor signals observed by the gas sensor array were correlated with the dilution factor (OU) calculated by the air dilution sensory test with several wastewater ($r^2=0.920{\sim}0.997$), except the sensor signals of sensor D measured in the plating plant wastewater. It seems likely that the gas sensor array plays a role in the evaluation of odor in wastewater and is useful tool for on-site odor monitoring in the wastewater facilities.

모델 데칸트를 이용한 고농도 슬러리상태 양돈폐수의 고액분리특성에 관한 연구 (A Study on the Solid-Liquid Separation Characteristics for Highly Concentrated Swine Wastewater Using Model Decanter)

  • 나은수;강호
    • 연구논문집
    • /
    • 통권30호
    • /
    • pp.67-77
    • /
    • 2000
  • This study was performed to investigate the characteristics and performance of model Decanter for separating swine wastewater to solid and liquid which is slurry state with 12.6% TS. Swine wastewater of the slurry tank was pumped into model Decanter which capacity was $2m^3$/hr in 10% TS Slurry inside of bowl was separated to solid-liquid by centrifugal acceleration. Sampling was done in the section of slurry feed pipe, supernatant outflow pipe, cake discharge pipe. After solid-liquid separation TS, $COD_cr$ and slurry volume reduction effect represented 38%, 40%, 19.6% respectively. Relation factor of model Decanter operation slurry concentration, optimum retention time of slurry, overflow velocity of supernatant, supernatant concentration, sludge removal rate etc. Optimal operation conditions can be set and evaluated efficiency based on the experimental results in the case of Decanter adopted for solid-liquid separation in highly concentrated swine wastewater.

  • PDF