• Title/Summary/Keyword: wastewater reuse facility

Search Result 9, Processing Time 0.017 seconds

Life-Cycle Assessment (LCA) for Eco-Design in a Wastewater Reuse Facility (친환경 설계를 위한 하수처리수 재이용시설의 전과정 평가)

  • Lee, Sin-Won;Kim, Sung-Keun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.2D
    • /
    • pp.255-266
    • /
    • 2011
  • In order to evaluate the environmental load occurring from the whole life cycle of a facility, LCA (Life Cycle Assessment) adopted by ISO is not only applied as an individual product but rather a complicated system involving buildings and/or infrastructure in a wide range of scope. The introducing of LCA to a wastewater reuse facility will assist to understand not only the treatment of water contaminants but also the overall system related to the interaction of involved, potential issues. This research implemented LCA for the establishment of the wastewater reuse facility. The results show that a fresh water aquatic Eco-toxicological Impact (88.3%) is the largest environment concern and the maintenance & operation phase has the most impact on the environment utilizing life cycle for the wastewater reuse facility. The civil works and chemical treatments in the maintenance & operation phase led to the biggest environmental impact. The results of this research can provide pertinent data of investigating opportunities for environmental improvement not limited to public officers regulating environmental policies, and could be used to make decisions for an environmentally sound and sustainable design in the initial phase of construction.

State of Swerage Systems and Prospects in Korea (우리 나라의 하수도현황과 전망)

  • 김갑수
    • Journal of environmental and Sanitary engineering
    • /
    • v.8 no.2
    • /
    • pp.65-84
    • /
    • 1993
  • This study reviewed the current status and problems of sewerage system in Korea and then proposed possible methods to correct the problems. Also, evaluation of future development in sewerage system is included. It can be summarized as follows : 1. Investment in sewerage system is relatively low . 0.23% of GNP, Considering that the investment portion is 0.35% in OECD and 0.63% in Japan, it should be increased further. 2. The reasons wily the investment in sewerage system is low can be ' (1) Low priority is given to the investment in sewerage system. Local government builds and operates its own wastewater treatment plant. Local government as well as residents prefer to invest their money in roadwork, housing and parks to in wastewater treatment facilities because of greater investment effects. (2) Besides capital investment, more maintenance cost is needed for sewerage system. Proper operation of wastewater treatment facilities requires a well-trained operator. Because of public conception that operation of wastewater treatment facility is a dirty job, it is difficult to find a well-trained operator. (3) It is difficult to estimate the effect of sewerage system (4) Cost required to build and maintain wastewater treatment facility should be paid by people, who benefit from the facility. People to benefit are sometimes different from people to pay. 3. Advanced treatment is necessary to protect the bay aura and raw water source as well as to prevent eutrophication of lakes and ponds. 4. Wastewater treatment facility were mainly build in big cities during the decade of 1980. Followings should be solved first to expand the facilities. (1) Rapid repair and construction of sewer. (2) Technical development of wastewater treatment . Prevention of efficient and economical wastewater . Development of efficient and economical wastewater treatment techniques . Development of high-efficiency treatment using bioreactor . Reuse of wastewater treatment plant effluent (3) Sludge treatment and disposal . Composting of sludge cakes . Development of techniques to reduce the volume of sludge cake : incineration and reuse of sludge ash and slag. (4) Utilization of wastewater treatment facilities . Construction of community parks or sports families(ie, on the tops of the covered aeration tanks and sedimention tanks) Construction of wastewater treatment facilities under ground and of parking facilities and community parks above ground. (5) Education of wastewater treatment personal.

  • PDF

Operation Strategy for a Multi-functional Storage Facility (하수저류시설 운영 전략 연구)

  • Yun, So-Young;Lim, Yoon-Dae;Oh, Jei-ll
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.6
    • /
    • pp.959-970
    • /
    • 2011
  • The frequent occurrence of sewer flooding and the intermittent discharge of non-point pollutions into the receiving water body are emerging issues recently due to the climate change and urbanization. These problems might be solved by introducing a multifunctional storage facility. Unlike a single-purpose storage facility, a multi-purpose storage facility should be operated at an instant to meet for flood prevention, reduction of non-point pollution and/or rainwater reuse. Considering various operational combinations it is suggested that prevention of sewer flooding coupled with reduction of non-point pollution is the most effective operational strategy for a multi-functional storage facility.

Environmental Restoration and Water Quality Management Modeling of Coastal Area by Reuse of Treated Wastewater (하수처리수 재이용에 따른 하천과 해역의 환경복원 및 수질관리 모델링)

  • Lee, Dae-In;Yoon, Yang-Ho;Park, Il-Heum;Lee, Gyu-Hyong;Cho, Hyeon-Seo
    • Journal of Environmental Science International
    • /
    • v.16 no.4
    • /
    • pp.505-521
    • /
    • 2007
  • This study estimated response of water duality and pollutant behavior according to the discharge and reuse of treated wastewater by three-dimensional eco-hydrodynamic model, and suggest plan that water quality management and environmental restoration in the coastal area including urban stream of Yeosu, Korea. Dispersions of low-saline water and COD by treated wastewater loads (design facility capacity, about $110,000m^3/d$) were very limited in near of effluent site. Nutrients, however, increase compared to the other water quality factors, especially total nitrogen was very sensitive to input loads. When reuse some of treated wastewater to Yeondeung stream, nitrogen was big influence on estuarine water quality. Although current characteristics of treated wastewater such as discharge and water quality were negligible to the change of marine environment, effluent concentration of COD, TN and TP, especially 40% of TN, are reduced within the allowable pollutant loads for satisfy environmental capacity and recommended water duality criteria. Also, controls of input point/non-point sources to Yeondeung stream and base concentration of pollutants in coastal sea itself are very necessary.

A Study on Membrane Fouling Contaminants and Control in Enhanced Sewage Treatment by Submerged Membrane Bioreactor (침지형 분리막을 이용한 오수고도처리 공정의 막오염 원인물질 및 제어에 관한 연구)

  • Park, Chul-Hwi;Yun, Jae-Gon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.5
    • /
    • pp.619-627
    • /
    • 2004
  • Purposes of this study were to examine closely the extracellular polymeric substances (EPS) which was a membrane fouling contaminant, to control detected EPS by powdered activated carbon (PAC) dosage etc. and to evaluate the possibility of practical reuse facility. With high removal efficiency of general pollutants, when the PAC is added to MBR, improvement of removal efficiency of $COD_{cr}$, and color was expected and treated wastewater can be reused. It was judged that the correlation between EPS and membrane fouling was very high. Carbohydrate and DNA in the EPS were judged to be cause of membrane fouling. If EPS could be controled, not only membrane fouling would be decreased but also operation time would be extended. In experiment of powdered activated carbon (PAC), characteristics of the best PAC for membrane fouling control were the particle size of $7{\mu}m$, lodine Number of 1,050, surface area of peat of $1,150m^2/g$. In lab test, operation time of MBR by PAC dosage of 200mg/gVSS was longer than one of MBR by without PAC dosage. Because EPS, especially carbohydrate and DNA, was controled successfully by PAC, membrane fouling in MBR could be decreased.

Composting using the Lime Stabilization of Dewatering Sludge from Centralized Swine Wastewater Treatment Facility (석회안정화 방법을 이용한 돈사분뇨공공처리시설에서 발생하는 탈수슬러지의 퇴비화)

  • Hwang, In-Su;Min, Kyung-Sok
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.4
    • /
    • pp.687-694
    • /
    • 2006
  • Dewatering sludge using inorganic chemicals with polymer has been evaded for reuse on account of the risks of high heavy metals contained and soil acidification. Composting feasibility of coagulation & dewatering sludges produced from livestock waste treatment plant was investigated. The results of analysis prove that dewatering sludge is valuable matter with suitable elements for composting if high quality ferric chloride ($FeCl_3$) is used for coagulation & dewatering process. In pot-cultivation of harvestes, using effects of dewatering sludge improved with lime treatment was very effective. The results of pot-cultivation proved that harms of crops according to different acid tolerances were not detected. But it was not applied to crops with weak acid tolerance or greenhouse for free from gas damage. Also, Further studies and monitorings are necessary to use sludges because results of pot-cultivation were generated differently by characteristics of soil, nutrient demand of plants, mature degree of sludge, consecutive cultivation and etc.

Economic Evaluation of Integrated Operation & Management through Operation Performance Analysis of Sewage Facilities (하수도시설 통합운영 성과분석을 통한 통합운영관리의 경제성 평가)

  • Shin, Jungsub;Chung, Seokhyun;Cho, Byoungog;Lee, Kwanhyung;Kang, Seonhong;Kim, Yongdae;Yoon, Joonjae
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.1
    • /
    • pp.63-72
    • /
    • 2017
  • For economic evaluation of integrated operation to sewage facilities, benefit-cost analysis was performed to watershed sewage works project in 7 watershed areas, 156 facilities. In this study, the cost before and after integrated operation was compared and benefits are calculated from the reduction of operators, increasement treated pollution loads, reduction cost through operation convenience, reduction water consumption through effluent reuse, and improvement of life benefit. The result showed that cost was 8,500million won and benefit was 16,747million won, so benefit was 49% higher than cost. B/C analysis result showed that B/C ratio was 1.97 and it is similar to other researches. The benefits of integrated operation included convenience of data management, increase of emergency response, decrease of complains with sewage which was not reflected numerically, so the benefits of integrated operation were expected much greater than this result

A study on the optimization of Ion Exchange Resin operating conditions for removal of KCl from CKD extract (CKD 추출액내 KCl 제거를 위한 이온교환수지 조업조건 최적화 연구)

  • Jang, Younghee;Lee, Ye Hwan;Kim, Jiyu;Park, Il Gun;Lee, Ju-Yeol;Park, Byung Hyun;Kim, Seong-Cheol;Lee, Sang Moon;Kim, Sung Su
    • Journal of the Korean Applied Science and Technology
    • /
    • v.36 no.4
    • /
    • pp.1088-1095
    • /
    • 2019
  • The CKD extract is wastewater from which KCl in CKD has been removed to reuse CKD as a cement raw material, and tried to reuse no extracts due to problems such as wastewater treatment facility expansion. As a result of removing KCl by the ion exchange method, the pH of the extract after ion exchange decreased from 12.7 to less than pH 2, and it was confirmed that H+ of the cation exchange resin was dissolved in the extract through ion exchange. In addition, the selectivity of the ion exchange was removed in the order of Ca2+, K+, it was determined that the increase in the contact time to remove the K+ ions. The batch system had a contact time of 6 times or more, compared to the continuous system, and showed 4 times of K+ removal efficiency and 7 times of Cl- removal efficiency. It was showed by analyzing the pH of the extract that more H+ of the cation exchange resin was extracted than OH- of anion exchange resin as the pH of the extract was changed.

Developments of Water Treatment System by Biological Fluidized Bed for Water Reuse Aquaculture (생물학적 유동층을 이용한 어류양식 순환수의 처리씨스템 개발)

  • LEE Ki-Wan
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.26 no.4
    • /
    • pp.380-391
    • /
    • 1993
  • The experimental study was made to propose the treatment method of wastewater in the high-density fish culture system. The BOD to COD ratios of effluents were almost same to 0.65 in the eel-farm, but were various in the farm rearing together with tilapia etc. A BOD rate curve of the eel-farm effluent could be described mathematically by the equation, $BODu=14.1(1-10^{-0.222t})+30.9(1-10^{-0.035(t-8)})$. Nitrification in Biological Fluidized Bed(BFB) system to treat the fish-farm wastewater could be reduce ammonium level up to $65{\sim}79\%$ when ammonium loading rates were between 0.014 and 0.075g $NH_4/g$ BVS-day. Nitrification efficiency was decreased by organic matters in the wastewater when ammonium loading was low(0.014 g $NH_4/g$ BVS-day). T-N removal ratios were decreased to increase loading in denitrification process, because of low C/N ratio. Based on much higher biological mass concentrations, BFB system takes many advantages of a practical viewpoint, such as stability of treatment efficiency and reduction of necessary site area for the facility, as compared with conventional treatment systems.

  • PDF