• Title/Summary/Keyword: wastewater retention time

Search Result 251, Processing Time 0.025 seconds

A Study on the Aerated Submerged Fixed-Film Bioreactor for Military Installation Wastewater Treatment (군용시설물(軍用施設物) 폐수처리(廢水處理)를 위한 고정생물막공법(固定生物膜工法)의 연구(硏究))

  • Suh, Hyung Suk;Ryu, Seong Ho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.7 no.1
    • /
    • pp.37-45
    • /
    • 1993
  • This research was performed to examined the applicability of a fixed-biofilm process for the wastewater treatment of military installations. Utilizing plastic net media, synthetic wastewater-average $BOD_5$ cocentration was $192mg/l$ treated in the three sets of reactors that have 8 hours, 6 hours, and 4 hours of hydraulic retention time. The results of this experiment showed that the biofilm was not detached easily, and the reactor was not closed by excess biomass. The average soluble $BOD_5$ concentrations of effluent were $6.0mg/l$ with 8 hours of retention time, $11.3mg/l$ with 6 hours of retention time, and $19.4mg/l$ with 4 hours of retention time. Especially it was reduced to $5.7mg/l$ in the second stage reactor with 4 hours of retention time. These resulted that the fixed-biofilm process could be adapted for the treatment of military installation wastewater.

  • PDF

Anaerobic treatment of red-bean processing wastewater in a sludge bed reactor (슬러지반응기에서 팥가공폐수의 철기성 처리)

  • 안재동;금재우;홍종향
    • Journal of environmental and Sanitary engineering
    • /
    • v.9 no.1
    • /
    • pp.29-37
    • /
    • 1994
  • Anaerobic treatment of wastewater of the red- bean processing industry was carried out and discussed an anaerobic sludge bed reactor( ASBR) as a preliminary study to evaluate applicability of given processes. The dimension of reactor were same as 0.09m- ID$\times $1.5m- height. The type of substrate and the hydraulic retention time( HRT) were considered as experimental variables. The synthetic wastewater with glucose in the laboratory, the wastewater from the red bean processing industry mixed with synthetic wastewater with variation of mixing percent were fed as substrate. The hydraulic retention time was changed from one day to five days. The gas production, the methane content in produced gas, efficiencies of COD removal and 55 removal were evaluated as principal characteristics. With synthetic wastewater as a substrate and at a hydraulic retention time of one day, characteristics of ASBR was the gas production(12$\ell$/day ), the methane content of produced gas(60%), the efficiency of COD removal(92%) and 55 removal(30%). With the real wastewater and at a hydraulic retention time of one day, the gas production and the efficiency of COD removal of the ASBR decreased with the proportion of real wastewater. The gas production and the efficiency of COD removal with real wastewater only was decreased to 70% and 87% of those with synthetic wastewater only, respectively. However, the methane content in produced gas and the efficiency of 55 removal with real wastewater only was increased significantly by 1.25 times and two times of those with synthetic wastewater only, respectively. However, the methane content in produced gas and the efficiency of 55 removal with real wastewater only was increased significantly by 1.25 times and two times of those with synthetic wastewater only, respectively. With real wastewater only as a substrate in the ASBR, the gas production was decreased with an increase of HRT, but the efficiency of COD removal increased with HRTI like the usual trend reported. As a conclusion, the wastewater of the red- bean Processing industry could be treated by anaerobic digestion successfully in the ASBR.Anaerobic treatment of wastewater of the red- bean processing industry was carried out and discussed an anaerobic sludge bed reactor( ASBR) as a preliminary study to evaluate applicability of given processes. The dimension of reactor were same as 0.09m- ID$\times $1.5m- height. The type of substrate and the hydraulic retention time( HRT) were considered as experimental variables. The synthetic wastewater with glucose in the laboratory, the wastewater from the red bean processing industry mixed with synthetic wastewater with variation of mixing percent were fed as substrate. The hydraulic retention time was changed from one day to five days. The gas production, the methane content in produced gas, efficiencies of COD removal and 55 removal were evaluated as principal characteristics. With synthetic wastewater as a substrate and at a hydraulic retention time of one day, characteristics of ASBR was the gas production(12$\ell$/day ), the methane content of produced gas(60%), the efficiency of COD removal(92%) and 55 removal(30%). With the real wastewater and at a hydraulic retention time of one day, the gas production and the efficiency of COD removal of the ASBR decreased with the proportion of real wastewater. The gas production and the efficiency of COD removal with real wastewater only was decreased to 70% and 87% of those with synthetic wastewater only, respectively. However, the methane content in produced gas and the efficiency of 55 removal with real wastewater only was increased significantly by 1.25 times and two times of those with synthetic wastewater only, respectively. However, the methane content in produced gas and the efficiency of 55 removal with real wastewater only was increased significantly by 1.25 times and two times of those with synthetic wastewater only, respectively. With real wastewater only as a substrate in the ASBR, the gas production was decreased with an increase of HRT, but the efficiency of COD removal increased with HRTI like the usual trend reported. As a conclusion, the wastewater of the red- bean Processing industry could be treated by anaerobic digestion successfully in the ASBR.

  • PDF

Development of a New Process for PVA Degradation in Desize Wastewater by lmmobilized Symbiotic Bacteria (고정화 공생 Bacteria를 이용한 호발폐수 중 PVA분해 신공정 개발)

  • 김정목;조무환조윤래정선용
    • KSBB Journal
    • /
    • v.6 no.4
    • /
    • pp.395-402
    • /
    • 1991
  • A new process was developed to degrade PVA(polyvinyl alcohol) in desize wastewater. Two symbiotic bacteria of Pseudomonas strain G5Y and PW were immobilized on the media by adsorption. A natural zeolite was chosen as the best media considering cell adhesion capacity, sedimentation rate, and material cost. PVA and COD removal efficiencies of this system for synthetic wastewater were 84% and 85% at the retention time of 6 hr, when the volumetric loading rate was PVA 8g/L·day and COD 8g/L·day, and cell density was 19,775 mg/L. In case of desire wastewater, they were 78% and 72% at the retention time of 6 hr, respectively, when the volumetric loading rate was PVA 8g/L·day and COD 13.2g/L·day, and cell density was 32,899mg/L. In case of desize wastewater, PVA and COD removal efficiencies were lower than synthetic wastewater, but cell density of the desize wastewater was lower than that of the synthetic wastewater, because there were insufficiency of necessary nutrition and variety of desize materials in the desize wastewater. A pilot test was successfully performed showing 88% and 82%, PVA and COD removal efficiencies at the retention time of 24 hr, when volumetric loading rate were 4.7 PVA g/L·day and COD 6.9g/L·day, and cell density was 12,,324 mg/L.

  • PDF

Characteristics of Phenol Degradation in Wastewater Treatment using Packed bed reactor (충진층 반응기를 이용한 폐수처리에서 페놀의 분해 특성)

  • 염승호;최석순
    • Journal of environmental and Sanitary engineering
    • /
    • v.11 no.3
    • /
    • pp.13-19
    • /
    • 1996
  • Packed bed reactor containing immobilized microorganisms which degraded phenol without growth was used to remove phenol from the synthetic wastewater. The effects of temperature, retention time(reactor volume/flow rate) and phenol concentration on the removal efficiency of phenol were investigated. The effect of temperature in the range of 20-30$\circ $C was negligible while retention time and phenol concentration influenced the removal of phenol significantly. When retention time was in the range of 1-1.5 hour, the removal efficiency of phenol was affected not by phenol concentration but by retention time itself while it was influenced by phenol concentration above 1.5 hour of retention time. The beads after 720 hours operation were swelled by 40 % in diameter which could be prevented by crosslinking with glutaraldehyde at the expense of cell activity.

  • PDF

Biological Removal Phosphorus Containing Swine Wastewater (생물학적 처리에 의한 돈사폐수의 인제거)

  • 신남철;박정호
    • Journal of Environmental Health Sciences
    • /
    • v.26 no.4
    • /
    • pp.15-20
    • /
    • 2000
  • The studies of swine wastewater treatment aim to development of process using soil microorganism. Removal rate of swine wastewater containing organic matter was 99 percent in case of high loading rate. Microorganism was devoted to improve the treatment efficiency of the process. According to the result obtained from biological treatment of high loading rate swine wastewater. Hydraulic retention time was 2.3 days in unit process of biological phosphorus removal. BO $D_{rm}$ / $P_{rm}$ ratio was 1122 in room temperature anaerobic process and 355.6 in mesophilic anaerobic process. And then phosphorus removal rate mesophilic anaerobic process was 3 time as much as than room temperature acaerobic process.

  • PDF

Biological Treatability of Toxic Industrial Wastewater (독성산업폐수의 생물학적 처리)

  • 원성연;박승국;정근욱
    • Journal of environmental and Sanitary engineering
    • /
    • v.14 no.4
    • /
    • pp.172-179
    • /
    • 1999
  • In this research, biological treatability test was conduced using seawater flocculated tannery wastewater by fixed biofilm reactor. During one cycle, the removal efficiency of organic corbon obtained with fixed biofilm process for treating tannery wastewater was considerably greater than that with activated sludge process. As the hydraulic retention time increased form 0.5day to 4day, removal efficiency of organic carbon was increased from 72% to 87.3%. Attached biomass in media increased with influent organic loading up to 29g MLSS/L, that could reduce the specific organic loading rate. The continual measurement of attached biomass was possible for the operation of the biofilm reactor. Equal and low nitrication rates were observed in both suspended growth activated sludge process and fixed biofilm process, despite commercial nitrifier was seeded. Through the process of treating the tannery wastewater, EC50 values which is measured by the use of Ceriopdaphnia dubia, were decreased to the extent of 50% after treatment of seawater flocculation and of 83% after biological treatment, respectively, compared to those of the untreated wastewater.

  • PDF

Characteristics of water quality at Han stream retention ponds in Jeju City (제주시 한천 저류지의 수질 특성)

  • Kim, Jinkeun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.2
    • /
    • pp.207-214
    • /
    • 2013
  • To evaluate characteristics of water quality in Jeju, a study was implemented for Han stream and retention ponds. Inflow water quality of retention ponds was heavily dependent on precedent rainfall, and no pesticide was detected due to the little artificial pollution sources. A smooth settling efficiency curve was noticed because heavy particles were already settled down in front of the retention pond. There were weak relationships between retention time and water quality, and this can be attributable to high concentration of pollutants influx at peak inflow. In addition, as Han stream retention pond has a role of groundwater recharge, inflow control based on water quality as well as quantity is needed to maximize pollutant removal at the retention ponds.

Development of a System to Treat Industrial Wastewater with High Carbonaceous and Nitrogenous Materials (고농도(高濃度) 유기물(有機物) 및 질소(窒素)를 함유(含有)한 산업폐수처리(産業廢水處理) 시스템 개발(開發))

  • Lee, Yong Woon;Lee, Byonghi;Chung, Seon Yong;Jung, Su Jung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.12 no.2
    • /
    • pp.67-75
    • /
    • 1998
  • The purpose of this study is to develop a system for treating industrial wastewater with high carbonaceous and nitrogenous materials. To investigate the potential of using this system, a number of experiments are conducted for about 7 months with the varieties of COD and $NH_3-N$ concentrations, and hydraulic retention time. In the system, 1,500mg/L of COD is remover over 95% in a retention time as low as 9 hours, and the $NH_3-N$ removal efficience is nearly 100% with 90mg/L of $NH_3-N$ in the influent. These results illustrate that the system can effectively be used to treat industrial wastewater containing high concentration of COD and $NH_3-N$.

  • PDF

Treatment of Polyester Weight Loss Wastewater Using Strains Degrading Ethylene Glycol and Terephthalic Acid (Ethylene Glycol과 Terephthalic Acid 분해균주를 이용한 감량가공폐수처리)

  • 서승교
    • Journal of Environmental Health Sciences
    • /
    • v.27 no.3
    • /
    • pp.43-48
    • /
    • 2001
  • Terephthalic acid and ethylene glycol resulting form the weight-reduction process of polyester make trouble in the operation of activated sludge process. Also, polyester weight loss wastewater shows high pH, high organic strength and wide variation of organic loading. Therefore, this study was conducted in order to improve treatment efficiency by activated sludge process with Pseudomonas sp degrading components of polyester weight loss wastewater. The CO $D_{Mn}$ and BO $S_{5}$ of the waste wastewater were 560~3,000 mg/$\ell$ and 8000~3,000 mg/$\ell$, respectively. pH was 11.8~12.3. COD removal efficiency by activated sludge-coagulation process with Pseudomonas sp was 94.1~95.8% for 35 hr of hydraulic retention time. Total organic carbon removal efficiency was 97.1%. Ethylene glycol and terephthalic acid in the wastewater were completely degraded during 32 hr of hydraulic retention time.e.

  • PDF

Biological Treatment of Textile Wastewater by Anaerobic-Aerobic Reactor System (Pilot 혐기-호기 공정을 이용한 염색폐수의 생물학적 처리)

  • 박영식;안갑환
    • Journal of Environmental Health Sciences
    • /
    • v.27 no.3
    • /
    • pp.11-20
    • /
    • 2001
  • An anaerobic sludge-aerobic fixed-bed biofilm(packed with ceramic support carrier of 1 inch size) reactor system was built up to treat textile wastewater. The efficiency of reactor system was examined by determining the effects of textile wastewater ratio(from 25% to 100% at HRT 24 h). The influent range of SCOD concentration and color were 1,036~1,357 mg/L, and 1,487~1,853 degree, respectively. When textile wastewater ratio was 100% and hydraulic retention time was 24 hours, SCOD removal efficiency by the anaerobic stage were 39.2% 100% and hydraulic retention time was 24 hours, SCOD removal efficiency by the anaerobic stage were 39.2% and the removal efficiency of the whole system were 75.8%. Color removal efficiency by the anaerobic stage were 45.4%(soluble color), and the removal efficiency of the whole system were 70.2%. In the A/A reactor system, the aerobic stage played an important role in removing both color and COD as well as anaerobic stage.

  • PDF