• Title/Summary/Keyword: wastewater flow

Search Result 672, Processing Time 0.029 seconds

Determination of Cd(II) after Preconcentration onto Microcrystalline p-Dichlorobenzene Loaded with 2-Mercaptobenzothiazole (2-Mercaptobenzothiazole이 내포된 p-Dichlorobenzene 미세결정으로 예비농축시킨 후 Cd(II) 정량)

  • Yoon, Ju-Im;Choi, Hee-Seon
    • Journal of the Korean Chemical Society
    • /
    • v.53 no.1
    • /
    • pp.27-33
    • /
    • 2009
  • A sensitive technique for the determination of trace Cd(II) in various real samples after preconcentration onto microcrystalline p-dichlorobenzene loaded with 2-mercaptobenzothiazole was developed. Several experimental conditions such as the pH of the sample solution, the amount of chelating agent 2-mercaptobenzothiazole, the amount of adsorbent p-dichlorobenzene-2-MBT, and the flow rate of sample solution were optimized. The interfering effects of various concomitant ions were investigated. Cu(II) interfered with more seriously than any other ions. However, the interference by Cu(II) could be overcome sufficiently by adjusting tartrate ion concentration to be 0.01M or by controlling the amount of 2-mercaptobenzothiazole contained in 0.20 g p-dichlorobenzene to be 0.12 g. The dynamic range, the correlation coefficient ($R^2$) and the detection limit obtained by this proposed technique were $0.5{\sim}30$ ng $mL^{-1}$, 0.9962, and 0.39 ng $mL^{-1}$, respectively. Thus, good results were obtained by the use of p-dichlorobenze as adsorbent matrix. For validating this proposed technique, the aqueous samples(wastewater, stream water, and reservoir water) and the plastic sample were used. Recovery yields of $93{\sim}104$ % were obtained. By F test, these measured data were not different from ICP-MS data at 95 % confidence level. Based on the results from the experiment, it was found that this proposed technique could be applied to the preconcentration and determination of Cd(II) in various real samples.

Modeling the effect of securing environmental flow using wastewater discharge on water qualifies of the three urban rivers in Taejeon (하수처리수를 이용한 하천유지유량 확보에 따른 대전 3대 하천에서의 수질모의)

  • Kim, Jeong-Kon;Yur, Joong-Hyun;Kim, Woo-Gu
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2005.05b
    • /
    • pp.1373-1377
    • /
    • 2005
  • 수질개선을 위한 많은 노력의 결과 대전광역시를 관통하는 대전 3태 하천인 갑천, 유등천, 대전천의 수질은 1990년 초반을 기점으로 많은 개선효과를 보이고 있다. 그러나 도시화에 따른 불투성층의 증가와 저류능력 감소, 치수를 목적으로 한 하도정비 등에 의하여 기저유출량은 과거에 비해 현저히 감소하였으며, 이로 인하여 갈수기에는 유량이 적어 생태적이고 친수적인 다양한 하천기능 수행에 많은 어려움을 초래하고 있다. 그러므로 대전광역시에서는 도심생태하천조성을 위한 방안으로 바람직한 하천기능을 회복하기 위하여 $70,000m^3/day$의 갑천수와 하수처리장에서 고도처리 된 $60,000m^3/day$의 방류수 중 $80,000m^3/day$를 각각 대전천과 유등천 상류지역에 공급하여 하천유지용수로서 사용하는 계획을 수립하였다. 하류지역에서의 갑천수와 고도처리 된 하수처리수를 대전천과 유등천의 상류지역에 하천유지용수로 공급함으로서 대전천과 유등천은 갈수기에도 각각 약 $1m^/sec,\;1.3m^3/sec$ 이상의 유량을 유지할 수 있을 것으로 예상된다. 갑천수와 고도처리수를 유지용수로 사용할 경우에 대한 수질변화를 QUAL2E를 이용하여 모의를 실시하였다. 유등천 합류부에서의 갑천수를 대전천 상류지역에 공급할 경우. 대전천에서의 수질은 $II\~III$등급을 유지할 것으로 보인다. 대전시의 지하철공사에서 발생하는 약 $9,600m^3/day$가량의 용출수와 대청호소수의 상수원수를 이용한 $10,000m^3/day$의 희석수를 유지용수로서 추가적으로 사용할 경우, 대전천의 BOD는 약 0.3mg/L가량의 개선효과가 있을 것으로 예상된다. 2011년 고도처리시설 완공시 방류수의 예상 수질은 BOD 10mg/L, TN 15mg/L, TP 2.0mg/L이하로 이를 유등천 상류부에 공급할 경우 유등천의 수질은 BOD 6.7mg/L, TN 9.80mg/L, TP 0.90mg/L를 나타낼 것으로 예측된다. 고도처리시설의 도입 후 금강 합류점에서 갑천의 예측 BOD는 7.4mg/L로 현재 9.0mg/L에 비하여 개선되지만 이는 금강수계 오염총량 관리계획의 시$\cdot$도 경계지점 목표수질인 5.9mg/L를 만족시키지 못하므로, 이를 만족시키기 위해서는 방류수 BOD 7.2mg/L이하로 처리해야 할 것으로 판단된다.

  • PDF

A Study on the Relation Characteristics between Bubble Size Distribution and Floating Time (버블의 크기별 입도분포와 부상시간과의 상관특성에 관한 연구)

  • Jeon, Gun;Park, Chul-Hwi
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.39 no.5
    • /
    • pp.277-281
    • /
    • 2017
  • Lately rainfall characteristics that it rains a lot in a short space of time often occurs. Because of this meteorological phenomena, the flow rate and concentration of initial rainfall for runoff and combined sewer overflows are changed. In the case of this inlet fluctuation, the flotation method at high surface loading rate is suitable for water quality management. the flotation method is able to meet the removal rate requirements of water public zone in 5 to 10 min which is irelatively short period. For assessment and diagonision of flotation method, A/S ratio is applied until now. But unfortunately, this has some limits for evaluation standard for certification and assessment of technical diagnosis and operation. This is why there is different efficiency in the bubble distribution at the same A/S ratio. The velocity and time of floating is changed by the different bubble distributions. The floating time affects the plant volume because the time factor make size dicision. Therefore the charateristics of bubble distribution and floating time at the same A/S ratio is necessary to apply to evaluation standard for certification and assessment of technical diagnosis and operation. For generalization of the method in certification and assessment, the characteristics of bubble distribution was studied. Until recently, using the optical device and shooting live video, there are some analysis technology of the floating factors. But this kind of technology is influenced by the equipment. with this level of confidence about the results, it is difficult to apply to generalize. According this reasons, this study should be applied on experiment generalization of method about measurement of relation between bubble distribution and floating time.

Oxidation of Phenol Using Ozone-containing Microbubbles Formed by Electrostatic Spray (전기장에 의해 생성된 미세기포를 이용한 페놀의 오존산화)

  • Shin, Won-Tae;Jung, Yoo-Jin;Sung, Nak-Chang
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.12
    • /
    • pp.1292-1297
    • /
    • 2005
  • The use of ozone in water and wastewater treatment systems has been known to be a process that is limited by mass transfer. The most effective way to overcome this limitation is to increase the interfacial area available for mass transfer by decreasing the size of the ozone gas bubbles that are dispersed in solution. Electrostatic spraying(ES) of ozone into water was investigated in this work as a method of increasing the rate of mass transfer of ozone into a solution and thereby increasing the rate of phenol oxidation. Results were obtained for ES at input power levels ranging from 0 to 4 kV and compared with two different pore-size bubble diffusers($10{\sim}15{\mu}m$ and $40{\sim}60{\mu}m$). It was determined that the rate of mass transfer could be increased by as much as 40% when the applied voltage was increased from 0 to 4 kV as a result of the smaller bubbles generated by ES. In addition, ES was shown to be more effective than the medium-pore-size($10{\sim}15{\mu}m$) bubble diffuser and the best results were achieved at low gas flow rates.

The Spatial Distribution of Harmful Chemical Substance in Sediment Around Busan Southern Port (부산 남항 해저퇴적물 중 유기오염물질 분포 특성에 관한 연구)

  • Min, Byeong-kyu;Lee, Jong-Hyuk;Ju, Mijo;Cho, Chonrae;Cho, Hyeon-Seo
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.26 no.2
    • /
    • pp.206-218
    • /
    • 2020
  • Located mostly inside the megacity of Busan, the Busan Southern Port is a multifunctional port with various nearby industry activities, including a joint fish market, ship repair facilities, and fishing boat facilities. If toxic chemicals generated by the industrial activities continue to flow into and accumulate in the sediment of the port, they can affect aquatic ecosystems and humans. Therefore, in this study, distribution levels and potential influent sources of organic pollutants, including polycyclic aromatic hydrocarbons (PAHs), polychlorinated biphenyls (PCBs), and butyltin compounds (BTs), in the sediment were investigated. The sediment samples were collected from eight sampling sites in November 2013 (first phase) and November 2014 (second phase). The mean concentrations of PAHs, PCBs, and BTs in the first and second sampling phages were 4174.0 ng/g-dry wt. and 1919.0 ng/g-dry wt., 166.3 ng/g-dry wt. and 21 ng/g-dry wt., and 50.9 ng/g-dry wt. and 30.8 ng/g-dry wt., respectively. The concentrations of the organic pollutants detected in the seabed sediments were lower in the second phase than in the first phase. In this study, the inflow sources of PAHs, PCBs, and BTs were found to be combustion, land, and municipal sewage or industrial wastewater, respectively.

A Study on Application of SBR Process for RO Retentate Treatment (RO 농축수 처리를 위한 SBR 공정 적용에 관한 연구)

  • Kim, Il-Whee;Joo, Hyun-Jong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.2
    • /
    • pp.79-85
    • /
    • 2012
  • In this study, Application of sequencing batch reactor (SBR) process for RO retentate treatment was performed. Efficiency of treatment by load and temperature variation was tested. The SBR process was operated two types as HRT per one cycle was 8 and 12 hours, respectively. Methanol was injected for an effective denitrificaion owing to low C/N ratio of the RO retentate. TN removal efficiency of the SBR process was relatively stable at the change of flow-rate and temperature. The optimum time cycle of SBR process was 2 cycle/day for TN removal, and in the case of 3 cycle/day, the effluent TN concentration was found under the effluent quality standard. In the result of assessment, the application of SBR process for RO retentate treatment was effective and could be utilized to design for the wastewater treatment plant. The specific nitrification rate (SNR) and specific denitrification rate (SDNR) were $0.043{\sim}0.066kg\;NH_3-N/kg\;MLVSS{\cdot}day$ and $0.096{\sim}0.287kg\;NH_3^--N/kg\;MLVSS{\cdot}day$, respectively. The derived kinetic could be applied for design to the aerobic and anoxic tank in the RO retentate treatment.

A Study on Degradation of Nitrogen Compounds by Biofilm Reactor Packed with Porous Media (다공성 담체를 이용한 생물막 반응조의 질소화합물 분해에 관한 연구)

  • Cho, Hae-Mi;Kim, So-Yeon;Yoon, Ji-Hyun;Han, Gee-Bong
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.5
    • /
    • pp.776-780
    • /
    • 2007
  • A biofilm reactor packed with porous media was investigated for nitrogen removal of synthetic wastewater. The effect of different loading rates on the nitrification was sustained to be steady state with stable efficiency of 50~60% in the range of $0.0083{\sim}0.017gNH_4-N/gMLVSS{\cdot}day$ of F/MN ratio and $1{\sim}2kgNH_4-N/m^3{\cdot}day$ of media volumetric loading rate. However, nitrification efficiency was rapidly decreased to 25~30% as F/MN ratio and media volumetric loading rate were increased to the range of $0.025{\sim}0.034gNH_4-N/gMLVSS{\cdot}day$ and $3{\sim}4kgNH_4-N/m^3{\cdot}day$, respectively. Also the consumption rate of alkalinity was higher under 8 hours of HRT than unter 6 hours of HRT. Accordingly the influent loading rate variation by detention time with influent flow influenced more on the nitrification efficiency than the influent loading rate variation by the influent concentration did. The temperature effect on the nitrification showed 25% higher in summer than in winter as the results reported by other researchers who reported that the nitrification efficiency in biofilm showed 20% increase from 55% to 75% when the temperature was raised from $20^{\circ}C$ to $25^{\circ}C$. Denitrification with sulfur-media showed 90% removal efficiency under steady-state with no effect from the increase of influent concentration and empty bed contact time (EBCT) change such as EBCT was decreased from 8.4 hr to 4.3 hr and $NO_3-N$ loading rate was changed within the range of $0.1{\sim}0.4kgNO^3-N/m^3{\cdot}day$. Accordingly Denitrification with sulfur-media is feasible for post denitrification at the concentration less than $80mgNO^3-N/L$.

Effect of major pollution sources on algal blooms in the Seungchon weir and Juksan weir in the Yeongsan River using EFDC (EFDC를 이용한 영산강 주요 오염 부하 저감에 따른 승촌보 및 죽산보 녹조 현상 개선 효과 분석)

  • Kim, Jinsoo;Kim, Jaeyoung;Seo, Dongil
    • Journal of Korea Water Resources Association
    • /
    • v.53 no.5
    • /
    • pp.369-381
    • /
    • 2020
  • In this paper, observed water quality, algal blooms and flow rates in the Yeongsan River and its boundaries including 8 tributaries and 2 wastewater treatment plants for two years of 2018-2019 were analyzed. It seems effects of non-point source load inputs from basin areas to the river may be significant though the field data availability was limited. The EFDC model was calibrated against data collected from 6 water level monitoring stations and 6 water quality monitoring stations, respectively, in the study area. Water quality improvement scenarios were developed assuming 50% and 75% reductions of major pollution sources including treatment plants and tributaries. The developed scenarios were applied to the EFDC model to estimate effects on algal bloom occurrences in the Seungchon weir and Juksan weir. Improvement of the effluent of Gwangju 1 WWTP by 75% did not show any effect on algal blooms for two weir locations. The major tributary affecting algal blooms in the Seungchon weir was the Hwangryong River. The Jisuk stream was found as the most important tributary for the Juksan weir followed by the effect of the Hwangryong River. Though it seems other scattered small nonpoint source load input to the Yeongsan river also seem to be important, it was not possible to reflect their effects appropriately due to field data availability.

A Study on the Improvement of Marine Pollution and Marine Litter Managements in Korea (우리나라 해양오염 및 해양폐기물관리 개선에 관한 연구)

  • Park, Kwang-Ha;Kwon, Young-Du;Kim, Jong-Sung
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.21 no.4
    • /
    • pp.33-43
    • /
    • 2013
  • That occur in the ocean and the efficient management of marine litter on marine pollution oil spill response one step further strategies are needed. Marine pollution accidents occurred in 2011, a total of 287 and was found in runoff 369 kL, respectively compared to the previous year decreased by 13% and 39%. Average amount of marine materials during 5-years represent the oil flow of 310.5 kL (heavy fuel oil of 106.0 kL, diesel of 178.9 kL, oily bilge water of 22.3 kL, other oil of 7.7 kL) and the waste of 62.3 tons, the hazardous and noxious substances (HNS) was 510.6 kL. Marine emissions in 2011 by type of waste that a total amount of dumping 3,972 $m^3$, and livestock manure 795 $m^3$(20%), waste water 1,431 $m^3$(36%), sewage sludge 887 $m^3$(22%), wastewater sludge, 813 $m^3$(21%), manure 5 $m^3$(0.1%), other 41 $m^3$(0.9%), respectively. The concept of marine waste and needs to be more clearly defined. Integrated management of hazardous chemicals according to the incident management system should be established. To remove of coastal pollution, response officer needs korean coast response system. Like the marine pollution response, coastal pollution response systems also require step response.

Determination and preconcentration of Cu(II) using microcrystalline p-Dichlorobenzene loaded with salicylaldoxime (Salicylaldoxime이 내포된 p-Dichlorobenzene 미세결정을 이용한 Cu(II)의 예비농축 및 정량)

  • Lee, Ha-Na;Choi, Hee-Seon
    • Analytical Science and Technology
    • /
    • v.23 no.3
    • /
    • pp.240-246
    • /
    • 2010
  • A technique for the determination of trace Cu(II) in various real samples by FAAS after the column preconcentration onto p-dichlorobenzene-SA adsorbent, which is microcrystalline p-dichlorobenzene loaded with salicylaldoxime (SA) has been developed. Several experimental conditions such as pH of the sample solution, the amount of chelating agent salicylaldoxime, the amount of adsorbent p-dichlorobenzene-SA, and flow rate of sample solution were optimized. The interfering effects of various concomitant ions were investigated. $CN^-$ interfered more seriously than any other ions. However, the interference by $1\;{\mu}g\;mL^{-1}\;CN^-$ could be overcome completely by controlling the concentration of Ni(II) to $20\;{\mu}g\;mL^{-1}$. The linear range, correlation coefficient ($R^2$) and detection limit obtained by this technique were $3.0\sim100\;ng\;mL^{-1}$, 0.9901, and $3.1\;ng\;mL^{-1}$, respectively. For validating this technique, the aqueous samples (wastewater, reservoir water and stream water) and the food samples (orange juice, fresh egg and skim milk) were used. Recovery yields of 93~104% were obtained. These measured mean values were not differents from ICP-MS data at 95% confidence level. The good results were obtained from the experiments using the rice flour certified reference material (CRM) sample. Based on the experimental results, it was found that this technique could be applied to the preconcentration and determination of Cu(II) for various real samples.