• Title/Summary/Keyword: waste treatment facilities

Search Result 192, Processing Time 0.023 seconds

Assessment of Water Pollution by the discharged water of the Abandended Mine

  • Kim, Hee-Joung;Yang, Jae-E.;Lee, Jai-Young;Park, Beang-Kil;Choi, Sang-Il;Jun, Sang-Ho
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.04a
    • /
    • pp.167-174
    • /
    • 2004
  • Several metalliferous and coal mines, including Myungjin, Seojin and Okdong located at the upper watershed of Okdong stream, were abandoned or closed since 1988 due to the mining industry promotion policy and thus disposed an enormous amount of mining wastes without a proper treatment facilities, resulting in water pollution in the downstream areas. AMD and waste effluents from the closed coal mines were very strongly acidic showing pH ranges of 2.7 to 4.5 and had a high level of total dissolved solid (TDS) showing the ranges of 1,030 to 1,947 mg/L. Also heavy metal concentrations in these samples such as Fe, Cu, Cd and anion such as sulfate were very high. These parameters of AMD and effluents were considered to be highly polluted as compared to those in the main stream area of the Okdong river and be major pollutants for water and soil in tile downstream area. Pollution indices of the surface water at the upper stream of Okdong river where AMD of the abandoned coal mines was flowed into main stream were in the ranges of 16.3 to 47.1. On the other hand, those at the mid stream where effluents from tailing dams and coal mines flowed into main stream were in tile ranges of 10.6 to 19.5. However, those at the lower stream were ranged from 10.6 to 14.9 These results indicated that mining wastes such as AMD and effluents from the closed mines were tile major source to water pollution at the Okdong stream areas.

  • PDF

A Study on the Architectural Planning of Material Handling System for the Airborne Infection Isolation Hospitals (호흡기 감염 격리병원의 물류시스템 계획에 관한 연구)

  • Choi, Kwangseok;Kwon, Soon Jung
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.23 no.2
    • /
    • pp.63-72
    • /
    • 2017
  • Purpose: The purpose of this study is to review the material handling system of the Airborne Infection Isolation Hospitals which is the one of the key elements of infection control and to improve the basic data for the planning and design of those facilities. Methods: Research was conducted by literature reviews and case studies for the material handling system of domestic and foreign Isolation hospitals. Results: The result of this study can be summarized into three points. First, a general isolation unit and a high level isolated unit need to be distinguished in terms of efficiency and safety. In particular, it is desirable that a high level isolated unit have to completely separate clean and soiled circulations, and soiled corridor should be installed by those means. By doing this, the medical staff can observe patient rooms and supply clean materials directly in the clean zone without wearing PPE, so that safety and work efficiency can be improved at the same time. Second, for the safe disposal of wastes, it is desirable to install a dedicated sterilizer per ward and sterilize it at least in the ward. In addition, It is desirable to install a central waste treatment room and a dedicated soiled corridor in consideration of the inadequate handling capacity and emergency situation. Third, the characteristics of material flow chart in the negative pressured isolation hospitals and the corresponding material handling system have been presented. Implications: Infection control is very important in safety, but it is necessary to respond to the symptoms of the patient.

A Study on Taehwa River Red Tide Solution through Stream Flow (유수소통을 통한 태화강 적조해결 방안 연구)

  • Cho, Hong-Je;Yoon, Sung-Kyu
    • Journal of Wetlands Research
    • /
    • v.13 no.2
    • /
    • pp.363-375
    • /
    • 2011
  • Recently, Water quiality of urban river largely have gotten better by virtue of sewer pipe laying and sewage treatment plants construction. or the various contaminants which is flowed in into river have generated underwater ecosystem disturbance and red tide by lack of sewage and waste water disposal facilities. With tidal river, taehwa river of ulsan metropolitan city has large river width and gradual stream bed gradient at the dry and storage period. Moreover, the flow is paralyzed due to the bridge pier protection work, consist of the mat foundation which is about 1.2km from two bridge and the contaminant is accumulated. it is caused by of the red tide generated from the several years or it activates. In this study, When flow area is largest by changing independent footing of bridge pier of two bridges and using RMA2 model, we hydraulically analyzed a variable breadth of velocity and discharge. Consequently, flow rate increased the maximum 103%, discharge was exposed to increase the maximum 61%. Directly this cannot extinguish the red tide but suppresses the red tide occurrence or can reduce. And it is determined to prevent the depositioning of the contaminant and can control fundamentally the red tide occurrence cause.

Dipole-Dipole Resistivity Survey on the Side of Han River near Nanjido Landfill (난지도에 인접한 한강변에서의 쌍극자-쌍극자 전기탐사)

  • Lee, Kiehwa;Kwon, Byung-Doo;Oh, Seok-Hoon;Kim, Cha-Seop
    • Economic and Environmental Geology
    • /
    • v.29 no.3
    • /
    • pp.335-343
    • /
    • 1996
  • The dipole-dipol electrical resistivity survey was conducted to investigate the probable contamination of the Han river by leachate from the near-by Nanjido Landfill. The survey line of 3 km was set along the unpaved road toward the Han river. For the convenience of the field work, the survey line was divided into four segments. The complete two-dimensional resistivity section was constructed by connecting the inversion result of each segment. Gravity survey was also carried out along the profile parallel to the resistivity line. Near surface resistivity generally appeared to be of very low value in most part of the survey area and the boundary between the alluvium layer and underlying basement rocks is well discriminated on the resistivity section. These results agree well with those of the preceding Schlumberger depth sounding made at adjacent area by Lee and fun (1995). The variation of thickness of the alluvium layer delineated by gravity anomaly profile also correlates well with the result of the resistivity survey on the qualitative basis. The problem of contamination by leachate from the Nanjido Landfill, where various waste materials have been dumped without any proper treatment facilities, has been remains unsolved yet. Therefore, we present the most probable passages of leachate flow based on the survey results and have briefly discussed about measure for contamination control. Considering the thickness of alluvium and the possible existence of fractured zone, the middle point between 1st and 2nd landfill and the midst of 1st landfill are the most hazardous regions to make leachates flow into the Han river. Since large amounts of leachates are observed from the test wells located on the lines extending from the border between the 1st and 2nd landfill and the middle of the lst landfill, contamination protection barriers are strongly recommended near these regions.

  • PDF

Trends of Study and Classification of Literatures on Environmental Pollution in Korea (우리나라에서의 환경오염 관련 문헌분류 및 연구동향)

  • 배준형;이종영;장봉기
    • Journal of Environmental Health Sciences
    • /
    • v.22 no.3
    • /
    • pp.37-48
    • /
    • 1996
  • The purpose of this study is to provide the valuable basic information that helps set the advanced direction of study in environmental pollution in the future. It classifies and analyzes 6, 531 papers according to their years, fields, and contents from 1962 to 1993 in Korea through Chunrian, a PC communication network, National Environment Research Institute(1989) in Seoul. Classifying papers by their fields, this study shows 19.6%(1, 281 papers) of total papers on water pollution, on which most emphasis was placed in the studies, 17.2%(1, 121 papers) on general remarks, 14.6%(952 papers) on environmental ecology, and 13.6%(891 papers) on air pollution. Classifying papers by their contents, this study tells us that the survey of state and evaluation of pollution degree took 28%(1, 829 papers) of total papers, and it seemed the most active study was carried out on this content. It then shows us that the treatment technology and mechanism shared 17.5%(1, 144 papers), and facilities and design took 1.9%(127 papers) which needed more studies in the future. As for the trends of study, the papers published until 1979 show that the water pollution accounted for 28.9% of total studies, on which the greatest emphasis was placed, while the papers in 1990s tell us that general remarks 34.7%, air pollution 14.9%, and water pollution 14.1%. It also shows that treatment technology and mechanism has had more importance since 1980s in water pollution, noise and vibration, waste materials, human wastes, and radioactive pollution. However, in sea pollution, policy and standard rather than treatment technology or method of measurement and analysis has been considered a more important one in 1990s. Analyzing the studies on general remarks, it tell us that the paper on environmental act, which were frequently conducted, accounted for 33.3% until 1979, while the papers on the environmental policy, in which the highest interest was kept, accounted 34.6% in 1990s. This study concludes that most papers had examined the survey on status and evaluation of pollution degree before 1980, while studies on solving the problems of environmental pollution have had more importance in the 1980s and 1990s. Therefore, in the future, more studies should be conducted actively on policy development to solve the problems of environment pollution as well as on encouragement of environmental consciousness.

  • PDF

Investigation on the Contamination of the Vicinity of Abandoned Coal Mines Located Near the Obong Darn and Preventive Measures (오봉댐 유역의 폐탄광에 의한 오염특성과 감소방안 연구)

  • Park, Sun Hwan;Chang, Yoon Young;Jeong, Jeong Ho;Son, Jeong Ho;Park, Seok Hyo
    • Journal of Environmental Impact Assessment
    • /
    • v.16 no.2
    • /
    • pp.143-156
    • /
    • 2007
  • This study has researched the management status and the pollution level of water, soil, stream sediments of 11 abandoned coal mines out of a total of 12 within Obong-Dam area except Bukyung mine, which was submerged when constructing Obong-Dam, and selected areas which are in needs to have pollution control facilities in the first place. From the results of examination on the runoff at the waste rock pile and mineheads, the runoff from Sueun mine (pH, Fe, Al), Samwon mine (pH, Al), Wangdo mine (pH, Al), Mose mine (pH, Fe, Al) and Daeryeong mine (pH) exceeded the permissible discharge standards of the water quality, but the water at merging point with Obong-Dam after joined with Doma branch satisfied both Water Quality Standards and Drinking Water Quality Standards. In regard to groundwater contamination, it is found that areas where exceeded the Drinking Water Quality Standards are Wangdo mine (pH), Jangjae mine (pH, Zn), Daeryeong mine (pH) whereas all areas satisfied Soil Contamination Warning Standards of Soil Environmental Conservation Law. When comparing a research result on underwater sediments of branches of abandoned mines to the EPA Guidelines for classification of great lakes harbor sediments, Dongguk Gaerim (Fe), Jungwon mine (Fe), Daebo mine (Mn), Samwon mine (Mn) and Daeryeong mine (Mn) showed mid-level of contamination, whereas Sueun (Fe, Mn), Daebo mine (Fe), Woosung mine (Fe, Mn), Wangdo mine (Fe, Mn), Mose mine (Fe) and Daeryeong mine (Fe) showed high-level of contamination. In addition, contamination levels of underwater sediments in Wangsan and Doma branch where abandoned mine's branches merge together, Wangsan branch showed no contamination at all whereas Doma branch shows mid-level of contamination which reflect the Doma branch is affected by waste rock pile and minehead runoff of the abandoned mines in the Doma branch area. It is concluded that Mose mine and Sueun mine required treatment of acid mine drainage. and Wangdo, Jungwon, and Samwon mines were in need of mine tailing and erosion control work. The Samwon mine additionally required a control system for closed minehead runoff. Although the Samwon mine reached a high concentration of Al, Mn $Ca^{2+}$, $SO{_4}^{2-}$ in the runoff, the levels decreased after it was combined with a tributary. It has been concluded that after further monitoring of the cause of pollution, a preventive measure system may be needed to be built.

A Study on the Improvement of Dairy Rousing Systems in Kore (한국의 낙농시설 개선에 관한 연구)

  • Kim, Moon-Ki;Koh, Chae-Koon;Kim, H. U.
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.24 no.1
    • /
    • pp.31-43
    • /
    • 1982
  • Engineering phase of dairy housing systems has close connection with the milk produc- tivity of dairy cattle, the quality of milk, extension of dairy production systems, labor- saving in management of dairy cattle and the like. Moreover, the rate of investment of dairy housing facilities is of relatively high level, However, there has been almost no research effort for the improvement of engineering aspects of dairy housing systems in Korea. The purpose of this study is to find out general engineering problems and to recomm- end the improvement in dairy housing systems in Korea. Field survey by means of questionaire, direct measurements, taking pictures and sketching was conducted to get necessary information for the study. Kyung-ki Do region was firstly chosen for sampling area since it has included more than half of the number of dairy farms of the whole country. The results obtained are summarized as follows: 1. In overall dairy farm layout, the dwellings of workers were ignored in the light of sanitary environment 2. The layout of stalls in a dairy barn belongs mostly to the type of double-row face-out, which is compatible with the emphasis of manure disposal activities. 3. While the width and length of stalls were sufficiently close to the standard dimension, the width of mangers was much less than the standard dimension. 4. The width and depth of manure gutters and the width of working alleys were much. less than the standard dimension. 5. The mooring equipment was mostly in the classes of chain or rope. The watering equipment was not facilitated independantly except the one cese of using watercup. 6. The bucket milkers with one or two bucket milkers with the capacity of two cattles. each were used as milking equipment in most dairy farms. 7. There were only few milk rooms independently spaced from other space, in which the arrangement of milking equipment was much less than the standard condition. 8. The lounging ground area was averaged to be sufficient for the activity of dairy herd. 9. Silos for silage used during winter consisted of mostly bunker silos, trench silos and underground vertical silos. Ordinary vertical silos were considered for the farmers to be inconvenient for the labor saving. 10. From the view point of heat conservation and moisture removal within the dairy barns, windows were not flexible for the easy ventilation and ceiling part was not adequate for temperatur maintenance. 11. Waste treatment and disposal systems were not provided with most dairy farms, therefore the livestock waste pollution problems would be serious in the near future.

  • PDF

A study on the Dioxin behavior in the process of representative pyrolysis/gasfication/melting plant (대표적인 열분해가스화 용융시설의 공정별 다이옥신 배출거동에 관한 연구)

  • Shin, Chan-Ki;Shin, Dae-Yun
    • Journal of environmental and Sanitary engineering
    • /
    • v.22 no.1 s.63
    • /
    • pp.1-16
    • /
    • 2007
  • The incineration process has commonly used for wastes amount reduction and thermal treatments of pollutants as the technologies accumulated. However, the process is getting negative public images owing to matter of hazardous pollutants emission. Specially dioxins became a main issue and is mostly emitted from municipal solid wastes incineration. In this reason, pyrolysis/gasfication/melting process is presented as a alternative of incineration process. The pyrolysis/gasfication/melting process, a novel technology, is middle of verification of commercial plant and development of technologies in Korea. But the survey about the pollutant emission from the process, and background data in these facilities is necessary. So in this survey, it Is investigated that the behavior of dioxins in three pyrolysis/gasfication/melting plant (S, T, P) of pilot scale. In case of S plant, concentration of dioxins shows high at latter part of cogenerated boiler and stack which are operate on low temperature conditions than a latter parts of pyrolysis and melting furnace which are operate on high temperature condition. Concentration of gas phage dioxins had increased after combusted gas passed cogenerated boiler and this is attributed to react of precursor materials such as chlorobenzene and chlorophenol. Concentration of dioxins in T plant showed lower levels at latter part of cooling equipment which are operate with water spray type on low temperature conditions than a latter parts of gasfied melting furnace which are operate on high temperature condition. Removal efficiency of dioxins at gas treatment equipment was 78.8 %. Concentration of dioxins in P plant was low at latter part of SDA/BF which is operate at low temperature conditions than a latter parts of pyrolysis gasfied chamber which are operate at high temperature condition. Removal efficiency of dioxins of SDA/BF was 85.9 % and therefore, it showed high efficiency at those of stoker type incineration facility. However, concentration of dioxins which emitted at high temperature condition were low in three facilities and satisfied present standard emission level of dioxins. To consider the distribution ratio of dioxins, Particulate phase dioxins at S and P plants showed similar ratio with which shows in current stoker type for middle scale domestic waste incineration facility. It is necessary to continuos monitoring the ratio of distribution of dioxins in T plant in because ratio of gas phage dioxins showed high.

Economic Feasibility Analysis of Building Seonam Biogas Combined Heat and Power Plant (서남 바이오가스 열병합발전 시설 건립의 경제적 타당성 분석)

  • Park, So-Yeon;Shin, Hyun-Ho;Yoo, Seung-Hoon
    • Journal of Energy Engineering
    • /
    • v.25 no.4
    • /
    • pp.141-151
    • /
    • 2016
  • Recently, technology for energy recovery from waste has been increasing interest globally including the Korea. In Korea, we have interested in using biogas generated from the sewage treatment process. As one alternative, there are operating biogas combined heat and power plant. The generation amount of the Sewage Sludge are expected to grow in the future. For this reason, total processing cost of Sewage Sludge will increase. To solve this problem, it seems will be invested with the expansion of facilities that use biogas as energy. Therefore, quantitative information on such facilities is required. Thus, this study attempts to economic feasibility analysis for Seonam Biogas Combined Heat and Power Plant. Meanwhile, as the benefit items for economic feasibility analysis consider electricity supply benefit except for heat supply benefit. The average prices of electricity use were residence 123.69, commercial 130.46, and industry 102.59 won per kWh for the year 2015, In addition, the economic benefit are calculated to be residence 310.21, commercial 378.49, and industry 222.87 won per kWh. The results of economic feasibility analysis is NPV 72.18 billion won, B/C 1.90, IRR 37%, shows that economic validity of Seonam Biogas Combined Heat and Power Plant.

Nitrogen Budget Analysis Using a Box Model for Hajeon Tidal Flat in the West Coast of Korea (Box model을 이용한 서해 곰소만 하전 갯벌의 질소 수지)

  • Yoo, Jae-Won;Hong, Jae-Sang;Yang, Sung-Ryull;Park, Kyeong
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.7 no.4
    • /
    • pp.257-266
    • /
    • 2002
  • To estimate the nitrogen budget and assess the purification function of a tidal flat ecosystem, a field survey was carried out at Hajeon tidal flat in Gomso Bay, the southern part of Byeonsan Peninsula, Chollabuk-do, Korea. A study area of 3.0$\times$4.5 ㎢ was established on the tidal flat and the concentrations of chlorophyll-a, DIN, DON, and TN were measured in the water column during the period of April 17-18, 1999: From the budget analysis, the loss rate of Chl-a was estimated to be -0.05 mg Chl/㎡/hr, which is approximately 7% of that at Issiki tidal flat in Aichi Prefecture, Japan. The lower loss rate of Chl-a in the study area was attributable to the lower standing crop of phytoplankton, the lower temperature that may reduce metabolic rates of biotic components and the lower biomass of macrobenthos in the study area. Over the 13.5 ㎢ of study area, Hajeon tidal flat removed 8.36$\times$10$\^$2/ kg N/day of TN, 5.36$\times$10$\^$3/ kg N/day of PON and 1.62$\times$10$\^$2/ kg N/day of phytoplankton-related PON, showing that the tidal flats may play an important role in removing nitrogen in coastal waters. The removal rate of PON, compared to the removal cost of the existing waste water treatment facilities, indicates that the economic value of the purification function of Hajeon tidal flat (13.5㎢) may be more than that of two large facilities.