• Title/Summary/Keyword: washing water recovery

Search Result 50, Processing Time 0.024 seconds

Recovery of Useful Components from Rice-washing Water Using Membranes (분리막을 이용한 쌀뜨물내 유효성분의 회수)

  • 정건용;박성희
    • Membrane Journal
    • /
    • v.12 no.3
    • /
    • pp.165-170
    • /
    • 2002
  • Membrane process was investigated to recover useful components, such as protein from rice-washing water generated in the production of the washed-rice. The filtration experiments were carried out using not only a dead-end Amicon cell to determine suitable membranes but also a hollow fiber ultrafiltration, spiral wound nanofiltration and reverse osmosis modules for home water purification. Ultrafiltration module(molecular weight cut-off : 10,000 dalton) was not suitable for recovery of useful components or protein in the rice-washing water, but nanofiltration and reverse osmosis modules showed a good performance. in the case of 250% concentration of the rice-washing water contained about 9% protein the proteins in concentrates of nanofiltration and reverse osmosis were 18% and 22%, which were about 2 and 2.4 times higher protein concentrations than those of feed, respectively.

A Tandem Water and Hexane Washing Method for Economical Recovery of Paclitaxel from Biomass (바이오매스 유래 파클리탁셀의 경제적인 회수를 위한 물과 헥산의 순차적 세척 방법)

  • Lee, Myeong-Gi;Kim, Jin-Hyun
    • Korean Chemical Engineering Research
    • /
    • v.60 no.1
    • /
    • pp.169-174
    • /
    • 2022
  • In this study, a tandem water and hexane washing process was developed to improve the recovery efficiency of paclitaxel derived from Taxus chinensis. The polar impurities contained in the sample were effectively removed by washing with water at a sample/water ratio of 1:40 (w/v) for 10 min. In addition, the non-polar impurities were effectively removed by washing with hexane at a sample/hexane ratio of 1:160 (w/v) for 20 min. A high purity of paclitaxel (>30.0%) was obtained in a short operating time (~30 min) by sequential washing with water and hexane.

Wastewater Recycling from Electroless Printed Circuit Board Plating Process Using Membranes (분리막을 이용한 무전해 PCB 도금 폐수의 재활용)

  • 이동훈;김래현;정건용
    • Membrane Journal
    • /
    • v.13 no.1
    • /
    • pp.9-19
    • /
    • 2003
  • Membrane process was investigated to recover process water and valuable gold from washing water of electroless PCB plating processes. The filtration experiments were carried out using not only a RO membrane test cell to determine suitable membrane for washing water but also spiral wound membrane modules of nanofiltration and reverse osmosis for scale-up. At first, RO-TL(tap water, low pressure), RO-BL(brackish water, low pressure) and RO-normal(for water purifier) sheet membranes made by Saehan Co. were tested, and the performance of RO-TL membrane showed most suitable f3r recovery of soft etching, catalyst and Ni washing waters. As a result of RO test cell, the experiments for scale-up were carried out using RO-TL modules far water purifier at 7bar and $25^{\circ}C $The permeate flux fur Au washing water was about 30 LMH, but Au rejection was less than 80%. The permeate fluxes for Pd, Ni and soft etching washing water were about 22, 17 and 10 LMH, respectively. The Pd, Ni and Cu rejections showed more than 85, 97 and 98% respectively. The nanofiltration module for water purifier was introduced to recover Au selectively from Au, Ni and Cu ions in Au washing water. Most of Ni and Cu ions in the feed washing water were removed, and only Au ion was existed 81.9% in the permeate. Furthermore, Au ion in the permeate was concentrated and recovered by RO-TL membrane module. Finally, Au was also able to recover effectively by using 4 inch diameter spiral wound modules of NF and RO-TL membranes, in series.

A Study on the Cleanup Process of HOCs-Contaminated Soil by Ex-situ Soil Washing Technology (Ex-situ 토양세척기법에 의한 소수성 유기오염물질로 오염된 토양의 정화에 관한 연구)

  • Choi, Sang-Il;Ryoo, Doo-Hyun;Jang, Min
    • Journal of Korea Soil Environment Society
    • /
    • v.2 no.1
    • /
    • pp.99-107
    • /
    • 1997
  • In this study, a series of batch-scale tests were conducted to optimize the design parameters for the application of soil washing techniques to the hydrophobic organic compounds(HOCs)-contaminated soil and to find the effective methods for the recovery of surfactants from washing effluent by using solvent. Several nonionic surfactants (polyoxyethylene oleyl ester) and sophorolipid were applied to the artificially contaminated soil (4,000 mg n-dodecane/kg dry soil). The effects of washing time, concentration of surfactant solution, dilution ratio, and temperature on washing efficiencies were examined. Hydrophile-liphophile balance (HLB) number was proven to be one of the important parameters for soil washing. The HLB numbers of OA-5 and sophorolipid are too low to form a stable soil-water emulsion. They showed very low washing efficiencies less than 10e1o. If HLB number is in the proper range to form a stable soil-water emulsion, surfactant having higher solubility for HOCs shows higher washing efficiency. OA-14 having higher HLB number than OA-9 formed more stable soil-water emulsion. But its washing efficiency was about 20% due to a lower molar solubility ratio (MSR) than OA-9. OA-9, which forms a stable soil-water emulsion and has comparatively high sotubility for HOCs, showed about 60% washing efficiency by itself. To recover anthracene effectively from OA-9 washing effluent by using benzene as an organic solvent, desirable temperature and pH were $30^{\circ}C$ and 2, respectively.

  • PDF

Effect of Operating Conditions and Recovery of Water Back-washing in Spiral Wound Microfiltration Module Manufactured with PVDF Nanofibers for Water Treatment (수처리용 PVDF 나노섬유 나권형 정밀여과 모듈에서 운전조건의 영향과 물 역세척 회복)

  • Kyung, Kyu Myung;Park, Jin Yong
    • Membrane Journal
    • /
    • v.25 no.2
    • /
    • pp.180-190
    • /
    • 2015
  • PVDF (polyvinylidene fluoride) nanofiber has the advantages such as excellent strength, chemical resistance, nontoxic, non-combustibility. Flat membranes with 0.3 and $0.4{\mu}m$ pore size respectively, were manufactured by PVDF nanofiber, and then each spiral wound module was prepared with them. A woven paper was not included in preparing the module with $0.3{\mu}m$ pore size; however, it was included the module with $0.4{\mu}m$ pore size. The permeate fluxes and rejection rates of the two modules were compared using pure water and simulation solution including kaolin and humic acid. The recovery rate and filtration resistance were calculated after water back-washing. In addition, the effect of flow rate and trans-membrane pressure on treatment efficiency and filtration resistance were investigated for the spiral wound module with $0.4{\mu}m$ pore size.

Multi- effect air gap membrane distillation process for pesticide wastewater treatment

  • Pangarkar, Bhausaheb L.;Deshmukh, Samir K.;Thorat, Prashant V.
    • Membrane and Water Treatment
    • /
    • v.8 no.6
    • /
    • pp.529-541
    • /
    • 2017
  • A multi-effect air gap membrane distillation (ME-AGMD) module for pesticide wastewater treatment is studied with internal heat recovery, sensible heat of brine recovery, number of stages and the use of fresh feed as cooling water in a single module is implemented in this study. A flat sheet polytetrafluroethylene (PTFE) membrane was used in the 4-stage ME-AGMD module. The maximum value of permeate flux could reach $38.62L/m^2h$ at feed -coolant water temperature difference about $52^{\circ}C$. The performance parameter of the module like, specific energy consumption and gain output ratio (GOR) was investigated for the module with and without heat recovery. Also, the module performance was characterized with respect to the separation efficiency of several important water quality parameters. The removal efficiency of the module was found to be >98.8% irrespective water quality parameters. During the experiment the membrane fouling was caused due to the deposition of the salt/crystal on the membrane surface. The membrane fouling was controlled by membrane module washing cycle 9 h and also by acidification of the feed water (pH=4) using 0.1M HCl solution.

Direct Purification of Lysozyme from Hen Egg White Using High Density Mixed Mode Adsorbent

  • KIM, WON KYUNG;BONG HYUN CHUNG
    • Journal of Microbiology and Biotechnology
    • /
    • v.9 no.3
    • /
    • pp.292-296
    • /
    • 1999
  • The high density mixed mode adsorbent known by the trade name of Mimo-AD was used to purify lysozyme directly from the hen egg white (HEW). The homogenized hen egg white was treated with the adsorbent in a stirred vessel for lysozyme adsorption, and then the adsorbent, easily separated from the HEW by sedimentation, was packed into a column. The remaining HEW and contaminant proteins were removed by washing with pH 11 distilled water in an expanded-bed state, and subsequently the elution was performed with pH 12 distilled water in a packed-bed state. By this simple and rapid adsorption, washing, and elution procedure, lysozyme was purified to>95% with an overall recovery yield of 66%. This process offers a great potential for industrial application by allowing the extraction of lysozyme while retaining the commercial value of HEW.

  • PDF

Investigation of Water-Washing Process Parameters for Removal of Alkali Metals and Chlorides from Electric Arc Furnace Dust (EAFD) (전기 제강로 분진(EAFD)으로부터 알칼리 금속 및 염화물 제거를 위한 수 세척 공정 운영인자 조사)

  • Lee, Han Saem;Park, Da so mi;Ha, Jong Gil;Shin, Hyun Sang
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.39 no.11
    • /
    • pp.626-633
    • /
    • 2017
  • The present study investigated the effect of a water-washing process, which is part of the acid hydrometallurgical process for recovery of high purity of zinc, on the removal of alkali metals and chlorides (Na, K, Ca, Cl) from Electric arc furnace dust (EAFD). Two EAFD samples with different properties were characterized by particle size, XRD and element analysis, and their washing efficiencies (%) on alkali metals and chlorides were compared according to pH, washing time, liquid to solid (L/S) ratio and number of washings. The results show that the alkali metals and chlorides could be effectively removed by the washing (at L/S ration of 3 for more than 30 min., pH 10~11) while minimizing loss of zinc (<0.1%), in which the washing efficiency was Na-78%, K-76%, Cl >99%, respectively. Na and K could be removed up to 97% and 89% respectively by 3 times of repeated washings. With increased sample volume (10 times) of the mixed (1:1, w/w) sample with two types of EAFD, it was confirmed that the pH(10~11) can be used as the main process control parameter for the washing of the alkali metals regardless of EAFD properties.

Effect of GAC Packing Mass in Hybrid Water Treatment Process of PVdF Nanofibers Spiral Wound Microfiltration and Granular Activated Carbon (PVdF 나노섬유 나권형 정밀여과와 입상 활성탄의 혼성 수처리에서 활성탄 충진량의 영향)

  • Kyung, Kyu Myung;Park, Jin Yong
    • Membrane Journal
    • /
    • v.27 no.1
    • /
    • pp.68-76
    • /
    • 2017
  • Flat membrane with $0.4{\mu}m$ pore size was prepared with PVdF (polyvinylidene fluoride) nanofiber, which has the advantages such as excellent strength, chemical resistance, non-toxicity, and incombustibility. The spiral wound module was manufactured with the flat membrane and a woven paper. Hybrid water treatment process was composed of the PVdF nanofibers spiral wound microfiltration and granular activated carbon (GAC) adsorption column. Effect of GAC packing mass was investigated by comparing the case of recycling or discharging the treated water using the synthetic solution of kaolin and humic acid. After each filtration experiment, water back-washing was performed, and recovery rate and filtration resistances were calculated. Also, effect of GAC adsorption was compared by measuring turbidity and $UV_{254}$ absorbance. As a result, there was no effect of GAC packing mass on turbidity treatment rate; however, the treatment rate of $UV_{254}$ absorbance was 0.7~3.6% for recycling the treated water, and increased to 3.2-5.7% for discharging the treated water. In the case of recycling the treated water, reversible filtration resistance ($R_r$) and irreversible filtration resistance ($R_{ir}$) trended to decrease as increasing GAC packing mass; however, total fitration resistance ($R_t$) was almost constant, and recovery rate of water back-washing trended to increase a little.

Characteristics of Heat Recovery Rate and Fouling according to Structures and Materials in Heat Exchangers (열교환장치의 구조 및 재질에 따른 열회수율과 파울링의 발생 특성)

  • Kim, Hyun-Sang;Kim, Yong-Gu;Bong, Choon-Keun;Lee, Myong-Hwa
    • Resources Recycling
    • /
    • v.24 no.2
    • /
    • pp.3-12
    • /
    • 2015
  • We researched characteristics of heat recovery rate and fouling according to structures and materials in heat exchangers like water preheater and air preheater. Economizer and air preheater have used in thermal electric power plant. we made small incinerator and heat exchangers to carry out simulated experiment. We observed fouling formation and change of heat recovery rate, combusting powdered coal for 24 hr. In economizer, fin tube type had the largest amount of fouling formation, followed by tube line type > pipe type > auto washing type according to structures. As heat recovery rate, fin tube showed highest recovery rate, followed by auto washing type > pipe type > tube line type. In air preheater, fin tube type had the largest amount of fouling formation, followed by fin plate type > pipe type > pipe type coated by teflon > pipe type coated by ceramic according to structures. And then, heat recovery rate showed the same oder.