Monitoring System Using Mobile Warning and Mobile Web-page (모바일 경보와 모바일 웹페이지를 통한 모니터링 시스템)

  • Ju, Seung Hwan;Seo, Hee Suk;Lee, Seung Jae;Kim, Min Soo
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.6 no.2
    • /
    • pp.29-38
    • /
    • 2010
  • It often occur to nature disaster that like earthquake, typhoon, etc. around KOREA. A Haiti and Chile also metropolitan area of KOREA occur earthquake. in result, People think of nature disaster. Structures of present age are easily affected by nature disaster. So we are important that warn of dangerous situation as soon as possible. On this study, I introduce Integrated monitoring system that administrator check a event as early. I develop Monitoring System using SMS(Short Message Service). Administrator always monitor structure on real-time using mobile web-page. As Administrator using mobile device like PDA, Administrator always monitor structure. As using this system, Damage of nature disaster is minimized and is prevented post damage.

A Study on the Load Forecasting Methods of Peak Electricity Demand Controller (최대수요전력 관리 장치의 부하 예측에 관한 연구)

  • Kong, In-Yeup
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.9 no.3
    • /
    • pp.137-143
    • /
    • 2014
  • Demand Controller is a load control device that monitor the current power consumption and calculate the forecast power to not exceed the power set by consumer. Accurate demand forecasting is important because of controlling the load use the way that sound a warning and then blocking the load when if forecasted demand exceed the power set by consumer. When if consumer with fluctuating power consumption use the existing forecasting method, management of demand control has the disadvantage of not stable. In this paper, load forecasting of the unit of seconds using the Exponential Smoothing Methods, ARIMA model, Kalman Filter is proposed. Also simulation of load forecasting of the unit of the seconds methods and existing forecasting methods is performed and analyzed the accuracy. As a result of simulation, the accuracy of load forecasting methods in seconds is higher.

Design and Implementation of Road Construction Risk Management System based on LPWA and Bluetooth Beacon

  • Lee, Seung-Soo;Kim, Yun-cheol;Jee, Sung-Hyun
    • Journal of the Korea Society of Computer and Information
    • /
    • v.23 no.12
    • /
    • pp.145-151
    • /
    • 2018
  • While commercialization of IoT technologies in the safety management sector is being promoted in terms of industrial safety of large indoor businesses, implementing a system for risk management of small outdoor work sites with frequent site movements is not actively implemented. In this paper, we propose an efficient dynamic workload balancing strategy which combined low-power, wide-bandwidth (LPWA) communication and low-power Bluetooth (BLE) communication technologies to support customized risk management alarm systems for each individual (driver/operator/manager). This study was designed to enable long-term low-power collection and transmission of traffic information in outdoor environment, as well as to implement an integrated real-time safety management system that notifies a whole field worker who does not carry a separate smart device in advance. Performance assessments of the system, including risk alerts to drivers and workers via Bluetooth communication, the speed at which critical text messages are received, and the operation of warning/lighting lamps are all well suited to field application.

An Inter-floor Noise Prevention System using an Open-source Controller (오픈소스 컨트롤러를 사용한 층간 소음 방지 시스템)

  • Kim, Tae-Hoon;Jang, Hyuk-Jae;Lee, Won-Young
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.12 no.5
    • /
    • pp.899-906
    • /
    • 2017
  • This paper proposes an inter-floor noise prevention system using an open-source controller. In the proposed system, Arduino which is a widely used open source controller analyzes sound signals and vibration signals with fast fourier transform. When the magnitude of the band-passed signal excesses the noise reference considering transmission loss of a panel or a wall, the system displays warning messages on an LCD module and a mobile device for users to be aware of the noise condition. In the experiment, the system has succeeded extracting and processing the band-passed signals between 130 Hz ~ 1040 Hz. When the magnitude of the extracted signal that is subtracted from the transmission loss exceeds 45 dB, the system has displayed the warning message on an LCD module and a mobile devicefor noise reduction.

Data Processing and Visualization Method for Retrospective Data Analysis and Research Using Patient Vital Signs (환자의 활력 징후를 이용한 후향적 데이터의 분석과 연구를 위한 데이터 가공 및 시각화 방법)

  • Kim, Su Min;Yoon, Ji Young
    • Journal of Biomedical Engineering Research
    • /
    • v.42 no.4
    • /
    • pp.175-185
    • /
    • 2021
  • Purpose: Vital sign are used to help assess the general physical health of a person, give clues to possible diseases, and show progress toward recovery. Researchers are using vital sign data and AI(artificial intelligence) to manage a variety of diseases and predict mortality. In order to analyze vital sign data using AI, it is important to select and extract vital sign data suitable for research purposes. Methods: We developed a method to visualize vital sign and early warning scores by processing retrospective vital sign data collected from EMR(electronic medical records) and patient monitoring devices. The vital sign data used for development were obtained using the open EMR big data MIMIC-III and the wearable patient monitoring device(CareTaker). Data processing and visualization were developed using Python. We used the development results with machine learning to process the prediction of mortality in ICU patients. Results: We calculated NEWS(National Early Warning Score) to understand the patient's condition. Vital sign data with different measurement times and frequencies were sampled at equal time intervals, and missing data were interpolated to reconstruct data. The normal and abnormal states of vital sign were visualized as color-coded graphs. Mortality prediction result with processed data and machine learning was AUC of 0.892. Conclusion: This visualization method will help researchers to easily understand a patient's vital sign status over time and extract the necessary data.

An Analysis of the Thermal Flow Characteristics in Engine-Room and VTRU in accordance with Application of Thermoelectric Device Cooling System to Prevent Overheating of the Korean Navy Ship VRTU (해군 함정 VRTU의 과열방지를 위한 열전소자 냉각장치의 적용에 따른 기관실 및 VRTU 내부 열 유동특성 분석)

  • Jung, Young In
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.9
    • /
    • pp.610-616
    • /
    • 2020
  • This study conducted joint research with the Navy logistics command ship technology research institute to resolve the occurrence of naval vessel's high-temperature warning and equipment shutdown caused by VRTU overheating during summer operation and the dispatch of troops to equatorial regions. The cooling effect was checked according to the installation of a thermoelectric device cooling system, and heat flow and heat transfer characteristics inside VRTU was analyzed using Computational Fluid Dynamics. In addition, the temperature distribution inside the engine room was assessed through interpretation, and the optimal installation location to prevent VRTU overheating was identified. As a result, the average volume temperature inside the VRTU decreased by approximately 10 ℃ with the installation of the cooling system, and the fan installed in the cooling system made the heat circulation smooth, enhancing the cooling effect. The inside of the engine room showed a high-temperature distribution at the top of the engine room, and the end of the HVAC duct diffuser showed the lowest temperature distribution.

Real-Time Soil Humidity Monitoring Based on Sensor Network Using IoT (IoT를 사용한 센서 네트워크 기반의 실시간 토양 습도 모니터링)

  • Kim, Kyeong Heon;Kim, Hee-Dong
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.35 no.5
    • /
    • pp.459-465
    • /
    • 2022
  • This paper reports a method to use a wireless sensor network deployed in the field to real-time monitor soil moisture, warning when the moisture level reaches a specific value, and wirelessly controlling an additional device (LED or water supply system, etc.). In addition, we report all processes related to wireless irrigation system, including field deployment of sensors, real-time monitoring using a smartphone, data calibration, and control of additional devices deployed in the field by smartphone. A commercially available open-source Internet of Things (IoT) platform, NodeMCU, was used, which was combined with a 9V battery, LED and soil humidity sensor to be integrated into a portable prototype. The IoT-based soil humidity sensor prototype deployed in the field was installed next to a tree for on-site demonstration for the measurement of soil humidity in real-time for about 30 hours, and the measured data was successfully transmitted to a smartphone via Wifi. The measurement data were automatically transmitted via e-mail in the form of a text file, stored on the web, followed by analyses and calibrations. The user can check the humidity of the soil real-time through a personal smartphone. When the humidity of a soil reached a specific value, an additional device, an LED device, placed in the field was successfully controlled through the smartphone. This LED can be easily replaced by other electronic devices such as water supplies, which can also be controlled by smartphones. These results show that farmers can not only monitor the condition of the field real-time through a sensor monitoring system manufactured simply at a low cost but also control additional devices such as irrigation facilities from a distance, thereby reducing unnecessary energy consumption and helping improve agricultural productivity.

A Location Survey of the Residential Environment of Detached House Where A Very Old People Lives Alone (단독가구 고령자가 거주하는 독립주택의 주거환경 실측)

  • 김현진;김학민;안옥희
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2000.11b
    • /
    • pp.91-95
    • /
    • 2000
  • With 106 detached houses where the aged people live alone, this study was conducted to perform a location survey of their residential environment. The result of this study is summarized as follows: While the surveyed houses' safety, sanitation and convenience appeared to be positive, with respect to the conditions of location, 73% of the surveyed houses did not meet the requirement for comfort. The average area of each space indicated that the bedding room was 12.05$m^2$, the living room 14.71$m^2$, the kitchen 9.06$m^2$, the bathing room 4.05$m^2$, and the rest room 2.59$m^2$. Then, 93.3% of the bedding rooms had the doorsill. Also, 97.2% of the surveyed houses had retrievable space. The form of their living room door showed a hinged door(54.5%) and a sliding door(45.5%) which were similar with each other. The finished material was that wood accounted for 42.6% which was highest. The cooking table form of kitchen was mainly "\ulcorner"-shaped(49.5%) and "\ulcorner"-shaped(48.5%) which were highest, and their average height appeared to be 815mm. The fuel used for kitchen was that gas accounted for 93.3%, while 95.2% of the surveyed houses was not equipped with any gas-warning device. 75.5% had an integrated type of bath room and toilet. In addition, the stepped difference between the bath room and other space was that 70.8% had the difference, but they had no a satisfactory sliding-prevention device(Not for 91.6%) or heating system(Not for 92.9%).stem(Not for 92.9%).

  • PDF

A Study of Dementia Patient Care Monitoring System Based on Indoor Location Using Bluetooth Beacon (블루투스 비콘을 활용한 실내위치기반 치매환자 모니터링 시스템에 관한 연구)

  • Kwon, Dae-Won
    • Journal of Digital Convergence
    • /
    • v.14 no.2
    • /
    • pp.217-225
    • /
    • 2016
  • In this study, a dementia patient care monitoring system is suggested that uses a wearable type bluetooth beacon to prevent them from going missing. This system shows whether the patients stay within the manageable area and sends a warning message to their monitoring managers' or guardians' smart devices when they leave it. The feature of the system is that it provides the service based on indoor location that makes the beacon worn by dementia patients continuously transmit their location information to the managing server through the smart terminal installed indoors or in hospitals and that enables the monitoring managers or the guardians to receive messages sent from the server that tell the patients' whereabouts through their smart devices. The system suggested in this paper is believed to be a system that effectively contributes to the prevention of the dementia patients' going astray from the hospitals and facilities where they are taking care.

Design and Implementation of Portable Electrostatic Meter Applicable to Industrial Site (산업 현장에 적용할 수 있는 휴대형 정전기 측정기 설계 및 구현)

  • Jang, Mun-Seok;Lee, Eung-Hyuk
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.23 no.6_2
    • /
    • pp.971-977
    • /
    • 2020
  • In this paper, We propose a portable electrostatic meter which can measure high voltage static electricity caused by friction to prevent fire or explosion accidents in grinding, crushing, power injection, transport, filling, dust removal, painting, and foreign matter removal processes. The proposed device not only shows static electricity strength in 4 steps with respect to distance and voltage but also gives warning with a buzzer, on process facilities that are likely to generate high voltage static electricity due to friction. The device is implemented by filtering the signal detected by the wireless antenna, amplifying the signal by 6 times, and passing the signal through the integrator circuit. Tests are carried out with an electrostatic discharge simulator. And the results show that 4 LEDs are turned on at the distance of 10cm, 3 LEDs at 12cm, 2 LEDs at 13cm, and 1 LED at 15cm, when a fixed voltage of 500V is given. And also, the tests show that the static electricity can be detected at 5cm on 100V, 10cm on 200V, 15cm on 500V, 20cm on 1000V, and 25cm on 1500V. We expect to reduce accidents caused by static electricity by allowing safety managers on fields where fire or explosion accidents can happen to monitor static electricity.