• Title/Summary/Keyword: wall storage system

Search Result 106, Processing Time 0.029 seconds

The Furniture Design Study of Changeable Wall Storage System for a Studio (원룸 형 주거공간을 위한 가변적 Wall Storage System 가구디자인 연구)

  • Kim, Myeong-Tae;Kim, Jun-Hee
    • Journal of the Korea Furniture Society
    • /
    • v.22 no.1
    • /
    • pp.1-12
    • /
    • 2011
  • Recently, the studio which is urban housing form is rapidly growing up by new residential space according to increasing 1~2 person households form because of Modern members who have changing patterns of life and diversification of social values. The resident of the studio who lives or uses the space for a work such as students, office worker and soho-jok has various characters by a society nature changes and a regional peculiarity. The studio form and function is getting change according to variety trend changes and their life styles. The role and use of residential space also have variety such as the resident who lives in the studio. This study is to find the space utilization for them and reasonable housing solution in that structure, furniture and Wall Storage System of existing studio which is based on the common life patterns. The study's purpose is to propose the furniture design of changeable Wall Storage System according to the analysis.

  • PDF

Study on PCM Applied Thermal Storage Wall System to Reduce Cooling Energy (냉방에너지 저감을 위한 PCM적용 축열벽 시스템 연구)

  • Lee, Kyuyoung;Ryu, Ri;Seo, Janghoo;Kim, Yongseong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.6
    • /
    • pp.247-256
    • /
    • 2014
  • The regulations to reduce energy consumption and carbon dioxide emission in building sectors are being developed and promoted all over the world. However, in Korea, as balcony extension of the apartments has been legally allowed, it became prevalent and resulted in excessive energy consumption. This study derived the possibility of PCM application to the thermal storage wall system through theoretical consideration and investigated the problems occurring when the balcony space has been extended to the diverted space. In addition, this study aims at the possibility of verifying the installation and confirming the cooling energy reduction effect, by conducting measuring tests with the actual installation of PCM applied thermal storage wall system. As a result of theoretical consideration, it is determined that the disadvantages with the existing thermal storage wall system can be complemented by applying PCM, and this study suggests the PCM applied Thermal Storage Wall System. The study was conducted on 1/6 of a miniature inner room of a domestic apartment with 84 $m^2$ of exclusive area. From the results of actual measurements, it is confirmed that the balcony extension structure can gain 11.3% of more calories than the existing balcony structure, resulting in the increase in cooling energy usage. It is determined that the installation of the PCM applied Thermal Storage Wall System may gain 25.2% of less calories to reduce cooling energy usage.

Experiment on measures of heat collection for passive solar water wall systems that provide heat storage and natural lighting control (축열과 채광조절을 겸한 자연형 태양열 수벽시스템의 집열방식별 성능실험)

  • Oh, Young-hoon;Choi, Ji-eun;Lee, Chul-sung;Yoon, Jong-ho
    • KIEAE Journal
    • /
    • v.16 no.4
    • /
    • pp.63-69
    • /
    • 2016
  • Purpose: This preliminary study investigated a potential of the water wall systems that provide heat storage and natural lighting control simultaneously. Method: In order for transparency of the water wall to be controlled, the study first proposed two measures: to adjust transparency of the water wall; to control transparency of water wall surface. The performance of two measures then was verified and compared by experiments. In addition, a trade-off between heat collect and heat storage resulting from using additive for adjusting transparency was investigated. Result: The experiment showed that the two measures are similar in performance. The investigation of trade-off relation showed the additive should have the same heat storage as the water to prevent decrease in thermal performance of the water wall. As an economical measure to control transparency of the water wall, this study suggested a measure of secondary heat transfer systems using shading device that first absorbs solar radiation and then transfers heat to the water wall. The experiment show that performance of the proposed measure is similar to controlling transparency of water wall surface. In conclusion, it is expected that the performance of the water wall can be economically maximized by using the proposed mean in terms of heating, cooling and lighting energy saving.

Experimental investigation of the excitation frequency effects on wall stress in a liquid storage tank considering soil-structure-fluid interaction

  • Diego Hernandez-Hernandez;Tam Larkin;Nawawi Chouw
    • Structural Engineering and Mechanics
    • /
    • v.89 no.4
    • /
    • pp.421-436
    • /
    • 2024
  • This research addresses experimentally the relationship between the excitation frequency and both hoop and axial wall stresses in a water storage tank. A low-density polyethylene tank with six different aspect ratios (water level to tank radius) was tested using a shake table. A laminar box with sand represents a soil site to simulate Soil-Structure Interaction (SSI). Sine excitations with eight frequencies that cover the first free vibration frequency of the tank-water system were applied. Additionally, Ricker wavelet excitations of two different dominant frequencies were considered. The maximum stresses are compared with those using a nonlinear elastic spring-mass model. The results reveal that the coincidence between the excitation frequency and the free-vibration frequency of the soil-tank-water system increases the sloshing intensity and the rigid-like body motion of the system, amplifying the stress development considerably. The relationship between the excitation frequency and wall stresses is nonlinear and depends simultaneously on both sloshing and uplift. In most cases, the maximum stresses using the nonlinear elastic spring-mass model agree with those from the experiments.

Shear performance of green timber wall panels (그린팀버월 패널의 전단성능)

  • Kim, Yun-Hui;Shin, Il-Joong;Jang, Sang-Sik
    • Korean Journal of Agricultural Science
    • /
    • v.38 no.3
    • /
    • pp.541-547
    • /
    • 2011
  • Korean building industry was developed by concrete and steel construction. However, concrete and steel have some problems which low carbon storage capability and difficulty of recycling. According to many studies, timber has high carbon storage capability, high recycling capability and sustainable supporting capability. Focus on this factors of timber, make new wall structure as Green Timber Wall panels and check the shear performance to use wall system in housing construction such as light-weight timber construction and nondearing wall on other construction. In the results, B-4-B and B-4-S show similar modulus of shear stiffness on the table. GH-4-GH has slip shape failure mode between Green Timber Wall boards. GH-4-GV has most stable characteristic curve than other specimens.

Seismic Analysis of Rectangular Liquid Storage Structures Ssing Fluid Elements (유체요소를 이용한 직사각형 유체 저장구조물의 지진해석)

  • 김영석;김제민;윤정방
    • Journal of Ocean Engineering and Technology
    • /
    • v.6 no.2
    • /
    • pp.46-54
    • /
    • 1992
  • In this paper, behavior of rectangular storage structures under earthquake loadings are investigated. Linear sloshing is assumed in this study. The effect of the wall flexibility is considered. Eulerian and lagrangian approaches are presented. The Eulerian approach is carried out by solving the boundary value problem for the fluid motion. In the lagrangian approach, the fluid as well as the storage structure is modelled by the finite element method. The fluid region is discretized by using fluid elements. The (1 $\times$ 1)-reduced integration is carried out for constructing the stiffness matrices of the fluid elements. Seismic analysis of the coupled system is carried out by the response spectra method. The numerical results show that the fluid forces on the wall obtained by two approaches are in good agreements. By including the effect of the wall flexibility, the forces due to fluid motion can be increased very significantly.

  • PDF

Comparison of Sampling and Wall-to-Wall Methodologies for Reporting the GHG Inventory of the LULUCF Sector in Korea (LULUCF 부문 산림 온실가스 인벤토리 구축을 위한 Sampling과 Wall-to-Wall 방법론 비교)

  • Park, Eunbeen;Song, Cholho;Ham, Boyoung;Kim, Jiwon;Lee, Jongyeol;Choi, Sol-E;Lee, Woo-Kyun
    • Journal of Climate Change Research
    • /
    • v.9 no.4
    • /
    • pp.385-398
    • /
    • 2018
  • Although the importance of developing reliable and systematic GHG inventory has increased, the GIS/RS-based national scale LULUCF (Land Use, Land-Use Change and Forestry) sector analysis is insufficient in the context of the Paris Agreement. In this study, the change in $CO_2$ storage of forest land due to land use change is estimated using two GIS/RS methodologies, Sampling and Wall-to-Wall methods, from 2000 to 2010. Particularly, various imagery with sampling data and land cover maps are used for Sampling and Wall-to-Wall methods, respectively. This land use matrix of these methodologies and the national cadastral statistics are classified by six land-use categories (Forest land, Cropland, Grassland, Wetlands, Settlements, and Other land). The difference of area between the result of Sampling methods and the cadastral statistics decreases as the sample plot distance decreases. However, the difference is not significant under a 2 km sample plot. In the 2000s, the Wall-to-Wall method showed similar results to sampling under a 2 km distance except for the Settlement category. With the Wall-to-Wall method, $CO_2$ storage is higher than that of the Sampling method. Accordingly, the Wall-to-Wall method would be more advantageous than the Sampling method in the presence of sufficient spatial data for GHG inventory assessment. These results can contribute to establish an annual report system of national greenhouse gas inventory in the LULUCF sector.

A Study on Behavior of Rectangular Liquid Storage Structures (직사각형 단면을 갖는 유체 저장 구조물의 거동에 관한 연구)

  • 박장호
    • Journal of the Korean Society of Safety
    • /
    • v.18 no.1
    • /
    • pp.101-107
    • /
    • 2003
  • Dynamic behavior of flexible rectangular liquid storage structures is analysed by the developed method. The rectangular liquid storage structures are assumed to be fixed to the ground and a moving coordinate system is used. The irrotational motion of invicid and incompressible ideal fluid is represented by two analytic solutions. One is the solution of the fluid motion in the rigid rectangular liquid storage structure due to ground motions and the other is the solution of the fluid motion by the motion of the wall in the flexible rectangular liquid storage structure. The motion of structure is modeled by finite elements. The fluid-structure interaction effect is reflected into the coupled equation of motion as added fluid mass matrix. The free surface sloshing motion and hydrodynamic pressure acting on the wall in the flexible rectangular liquid storage structure due to the horizontal ground motion are obtained by the developed method and verified.

Experimental Study on the Thermal Performance of Passive Solar Trombe Wall System (자연형태양열 트롬월 축열벽 시스템의 열성능 특성 실측 분석 연구)

  • Yoon, Jong-Ho;Baek, Nam-Choon;Shin, U-Cheul
    • Journal of the Korean Solar Energy Society
    • /
    • v.28 no.1
    • /
    • pp.75-81
    • /
    • 2008
  • Thermal performance of passive solar Trombe wall system which is applied on the south wall of KIER Zero energy Solar House has been monitored for 6 months of heating season. Based upon the long-term measurement results, extensive statistical analysis was conducted to investigate temperature profiler and heat flow pattern in Trombe wall system under actual operating condition. Heat flow characteristics depending on the time variation of day and month was clearly revealed. Heat gain and loss on the inner surface of the Trombe wall was calculated base upon measured temperature data. Those results would be utilized to improve the efficiency of new type solar storage wall system.

A Basic Study on the Air Circulation System for Heating using Solar and Geothermal Heat - Focused on Trombe Wall Thermal Storage Performance using Solar Heat - (태양열과 지열을 이용한 난방용 공기순환시스템 기초연구 - 태양열을 이용한 트롬월식의 축열성능 중심으로 -)

  • Kim, Byung-Yun;Choi, Yong-Seok
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.19 no.4
    • /
    • pp.49-56
    • /
    • 2017
  • Each country in the world currently concentrates on shifting into clean energy, which can be alternative energy, for global environment protection and solution to the problem of fossil fuel depletion. The Korean government is predicted to develop renewable energy, such as solar power, ground power, and offshore wind power, and to increase their supply ratios by ending the use of coals and nuclear power plants. This study conducted experiments on thermal storage performance of Trombe wall thermal storage materials using solar power and simulations in order to offer baseline data for the development of a hybrid air circulation system for heating that can maximize efficiency by simultaneously using solar and geothermal power. The study results are as follows: (1) In all the specimens with 3m, 5m, and 7m in the length of thermal storage pipe, $5.7^{\circ}C$, $7.8^{\circ}C$, and $10.5^{\circ}C$ rose, respectively, as the thermal storage effect of the specimens attaching insulation film and black tape to the general funnel. They were most excellent in terms of thermal storage effect. (2) As a result of thermal performance evaluation on the II type specimens, II-3 ($7.8^{\circ}C$ rise) > II-4 ($5.3^{\circ}C$ rise) > II-1 ($3.9^{\circ}C$ rise) > II-2 ($2.3^{\circ}C$ rise) was revealed, and thus II-3 (insulation film + black tape) was most effective as shown in the I type. (3) This study analyzed air current and temperature distribution inside of the greenhouse by linking actually measured values and simulation interpretation results through the interpretation of CFD (computational fluid dynamics). As a result, the parts absorbing heat and discharging heat around the thermal storage pipe could be visibly classified, and temperature distribution inside of the greenhouse around the thermal storage pipe could be figured out.