• 제목/요약/키워드: wall panels

검색결과 237건 처리시간 0.024초

Flow-induced pressure fluctuations of a moderate Reynolds number jet interacting with a tangential flat plate

  • Marco, Alessandro Di;Mancinelli, Matteo;Camussi, Roberto
    • Advances in aircraft and spacecraft science
    • /
    • 제3권3호
    • /
    • pp.243-257
    • /
    • 2016
  • The increase of air traffic volume has brought an increasing amount of issues related to carbon and NOx emissions and noise pollution. Aircraft manufacturers are concentrating their efforts to develop technologies to increase aircraft efficiency and consequently to reduce pollutant discharge and noise emission. Ultra High By-Pass Ratio engine concepts provide reduction of fuel consumption and noise emission thanks to a decrease of the jet velocity exhausting from the engine nozzles. In order to keep same thrust, mass flow and therefore section of fan/nacelle diameter should be increased to compensate velocity reduction. Such feature will lead to close-coupled architectures for engine installation under the wing. A strong jet-wing interaction resulting in a change of turbulent mixing in the aeroacoustic field as well as noise enhancement due to reflection phenomena are therefore expected. On the other hand, pressure fluctuations on the wing as well as on the fuselage represent the forcing loads, which stress panels causing vibrations. Some of these vibrations are re-emitted in the aeroacoustic field as vibration noise, some of them are transmitted in the cockpit as interior noise. In the present work, the interaction between a jet and wing or fuselage is reproduced by a flat surface tangential to an incompressible jet at different radial distances from the nozzle axis. The change in the aerodynamic field due to the presence of the rigid plate was studied by hot wire anemometric measurements, which provided a characterization of mean and fluctuating velocity fields in the jet plume. Pressure fluctuations acting on the flat plate were studied by cavity-mounted microphones which provided point-wise measurements in stream-wise and spanwise directions. Statistical description of velocity and wall pressure fields are determined in terms of Fourier-domain quantities. Scaling laws for pressure auto-spectra and coherence functions are also presented.

유엔스튜디오 업무시설 외피 패널의 형태적 특성 분석 (An Analysis of Façade Panel Characteristics of UN Studio's Office Projects)

  • 고성학
    • 대한건축학회논문집:계획계
    • /
    • 제35권8호
    • /
    • pp.23-34
    • /
    • 2019
  • The façade, a fundamental function as a skin that protects human life from external environment such as cold and hot weather, snow, rain, and wind, etc, has served as a media for communication between indoor space of the building and outside space. From the media for communication point of view, the approach to envelope design, in which environmental elements are transmitted internally through the filtering of external environments, has been evolving in various ways from the past to the present. Today, modern architecture technologies including curtain wall systems and user-friendly computer programming and environmental analysis programs demonstrate a differentiated approach to envelope design related to the indoor environment. For this reason, it is worth noting that the envelope design factors and trends that appear variously in the UNStudio's projects before and after the 2000s. The factors reflected in the envelop design in conjunction with the indoor environment obtained through the case study of the UNStudio's office projects were daylight environment, thermal environment, ventilation, noise, privacy and view, and consideration for daylight environment and thermal environment was reflected in many cases through the case study. Looking at the changes in the diagrams in order of year, it can be seen that the envelope design using the environmental analysis tool has been performed since 2006. This is a clue to show the envelop design changes from the conceptual method to the data-based one. The diagrams and analysis results related to the envelop design showed that the thermal environment related to solar radiation was the most, and no diagrams and analysis related to the indoor illumination were found. Since 2010, PV panel installation has been shown in the envelope design, which can be found in the increased efficiency of PV panels due to the technological advances and the decrease in production cost.

Whole-life wind-induced deflection of insulating glass units

  • Zhiyuan Wang;Junjin Liu;Jianhui Li;Suwen Chen
    • Wind and Structures
    • /
    • 제37권4호
    • /
    • pp.289-302
    • /
    • 2023
  • Insulating glass units (IGUs) have been widely used in buildings in recent years due to their superior thermal insulation performance. However, because of the panel reciprocating motion and fatigue deterioration of sealants under long-term wind loads, many IGUs have the problem of early failure of watertight properties in real usage. This study aimed to propose a statistical method for wind-induced deflection of IGU panels during the whole life service period, for further precise analysis of the accumulated fatigue damage at the sealed part of the edge bond. By the estimation of the wind occurrence regularity based on wind pressure return period, the events of each wind speed interval during the whole life were obtained for the IGUs at 50m height in Beijing, which are in good agreement with the measured data. Also, the wind-induced deflection analysis method of IGUs based on the formula of airspace coefficient was proposed and verified as an improvement of the original stiffness distribution method with the average relative error compared to the test being about 3% or less. Combining the two methods above, the deformation of the outer and inner panes under wind loads during 30 years was precisely calculated, and the deflection and stress state at selected locations were obtained finally. The results show that the compression displacement at the secondary sealant under the maximum wind pressure is close to 0.3mm (strain 2.5%), and the IGUs are in tens of thousands of times the low amplitude tensile-compression cycle and several times to dozens of times the relatively high amplitude tensile-compression cycle environment. The approach proposed in this paper provides a basis for subsequent studies on the durability of IGUs and the wind-resistant behaviors of curtain wall structures.

Predicting restraining effects in CFS channels: A machine learning approach

  • Seyed Mohammad Mojtabaei;Rasoul Khandan;Iman Hajirasouliha
    • Steel and Composite Structures
    • /
    • 제51권4호
    • /
    • pp.441-456
    • /
    • 2024
  • This paper aims to develop Machine Learning (ML) algorithms to predict the buckling resistance of cold-formed steel (CFS) channels with restrained flanges, widely used in typical CFS sheathed wall panels, and provide practical design tools for engineers. The effects of cross-sectional restraints were first evaluated on the elastic buckling behaviour of CFS channels subjected to pure axial compressive load or bending moment. Feedforward multi-layer Artificial Neural Networks (ANNs) were then trained on different datasets comprising CFS channels with various dimensions and properties, plate thicknesses, and restraining conditions on one or two flanges, while the elastic distortional buckling resistance of the elements were determined according to the Finite Strip Method (FSM). To develop less biased networks and ensure that every observation from the original dataset has the chance of appearing in the training and test set, a K-fold cross-validation technique was implemented. In addition, the hyperparameters of the ANNs were tuned using a grid search technique to provide ANNs with optimum performances. The results demonstrated that the trained ANNs were able to predict the elastic distortional buckling resistance of CFS flange-restrained elements with an average accuracy of 99% in terms of coefficient of determination. The developed models were then used to propose a simple ANN-based design formula for the prediction of the elastic distortional buckling stress of CFS flange-restrained elements. Finally, the proposed formula was further evaluated on a separate set of unseen data to ensure its accuracy for practical applications.

270,000 kL급 LNG 저장 탱크 외조의 폭발량에 따른 손상도 해석적 평가 (Analytical Assessment of Blast Damage of 270,000-kL LNG Storage Outer Tank According to Explosive Charges)

  • 김장호;최승재;최지훈;김태균;이태희
    • 콘크리트학회논문집
    • /
    • 제28권6호
    • /
    • pp.685-693
    • /
    • 2016
  • LNG 저장탱크의 외조는 콘크리트 부재로 수직 방향 및 원환 방향 프리스트레싱 벽체 구조인데, 저장탱크의 대형화가 이루어짐에 따라 프리스트레싱 구간이 길어지고 그에 따른 극한 하중을 받는 LNG 저장탱크의 거동에 대한 분석이 필요하다. 본 연구는 주요 사회기반시설구조물의 하나인 LNG 저장탱크에 테러와 같은 폭발 사고가 발생하였을 때 안전성 향상을 위하여 폭발 저항 성능에 대한 분석연구를 수행하였다. 해석은 유한요소해석 프로그램인 LS-DYNA를 사용하여 270,000kL급 LNG 저장탱크 외조의 TNT 폭발에 대한 거동을 평가해보고자 한다. 또한 TNT 폭발량에 따른 폭발에 대한 LNG 저장탱크의 거동 비교를 통해 구조물의 안전성 및 사용성을 평가해보고자 한다. 이 연구의 결과를 통해 폭발량에 따른 구조물에 거동 변화를 확인하고, 설계 시 안전성 기준 및 검토의 보조자료로 활용할 수 있도록 한다.

패널굴절방식 환기창 온실의 환기효과 (Ventilation Effect of the Greenhouse with Folding Panel Type Windows)

  • 김진영;이시영;김현환;전희;윤익학
    • 생물환경조절학회지
    • /
    • 제11권1호
    • /
    • pp.5-11
    • /
    • 2002
  • 본 연구는 여름 같은 고온기나 외부온도가 높지 않아도 시설내 온도가 많이 상승하는 봄 .가을 같은 시기에 온실내 고온 공기를 외부로 신속하게 유출시켜 강제환기를 사용하지 않고도 온실내부의 환경을 조절 할 수 있는 새로운 자연 환기창을 개발하는데 목적을 두고 수행하였다 패널굴절방식 측창은 지면에 가까운 쪽의 패널 하부에 절점을 두고 패널 상부가 측고 부위로부터 가이드 레일을 따라 하향하도록 구성하여 창이 개방되게 하였고, 천창은 측고 부위에 절점을 두고 용마루 쪽의 패널 상부가 가이드 레일을 따라 경사진 지붕면을 따라 하향하도록 구성하여 고온 공기층이 정체되어 있는 온실 상부인 측고 부위와 용마루 부위가 개방되도록 하였다. 굴절 패널의 상부 개방거리는 X=L(1-cos$\theta$)로 나타낼 수 있고 측면 개방 거리는 Y=L/2$\times$sin$\theta$로 나타낼 수 있다. 천창 개방시간은 4분 20초 소요되었으며 개방 시작한 2분 후부터 온도가 하강하기 시작하였고, 완전 개방 2분 후부터는 외기온과의 온도차 3~4$^{\circ}C$정도를 유지하면서 평형상태를 유지하였다. 패널굴절방식 환기창 온실의 환기성능은 체적환기량이 22.3-94.3m$^3$.m$^{-2}$ .h$^{-1}$이었으며, 환기 횟수는 15.2~39.3회.h$^{-1}$로 나타나 일반적인 연속형 천창의 10~15회.h$^{-1}$ 정도에 비해 환기효과가 높은 것으로 나타났다. 그리고 벤로형 온실과의 천창개폐시 온도하강을 비교하였을 때 환기효과가 2배 이상 높은 것으로 판단되었다.$_{r}$", $\mu$$_{r}$′) and the dielectric loss ($\varepsilon$$_{r}$"/$\varepsilon$$_{r}$′) were increased. It was caused that the absorption characteristics of the absorber were improved. The conduction loss and magnetic loss were expected to be occurred together because two matching frequencies were shown with carbon addition. It was confirmed that the matching frequency of the microwave absorber could be controlled by controlling heat-treatment temperatures and carbon additions.ons.tions.加的)으로 되거나 과가황(過加黃)이 될 우려가 있는 제조공정(製造工程)에서는 흔히들 이 방법(方法)을 무시(無視)하고 있다. 여기서 강조(强調)해 두어야 할 것은 항상 제품(製品)의 외부(外部)를 완전(完全)히 가황(加黃)시킬 필요(必要)는 없다는 것이다. 다공성(多孔性)이나 기포생성(氣泡生成)을 조장(助長)하는 불량가황상태(不良加黃狀態)와 표면(表面)에서의 과가황상태간(過加黃狀態間)의 균형(均衡)을 취(取)해 줘야 하는데 물론(勿論) 이때는 가황시간(加黃時間)을 단축(短縮)시켜야 한다는 경제적(經濟的)인 측면(側面)도 아울러 고려(考慮)해야 한다

경량칸막이 벽체를 통한 다중구획공간에서의 화재위험성에 관한 연구 (A Study on Fire Hazards in Multiple Compartments with Lightweight Partition Walls)

  • 박상민;최수길;진세영;김시국
    • 한국화재소방학회논문지
    • /
    • 제34권2호
    • /
    • pp.14-21
    • /
    • 2020
  • 본 논문은 ISO 9705 2/5축소모델 2개를 실내 공간구획에 사용되는 경량칸막이를 이용하여 구획 한 후 ISO 9705 시험을 재현하여 이면부로의 화재위험성에 관한 연구이다. 실험 시료는 시공 시 가장 많이 사용되고 있는 SGP 칸막이, 스터드 칸막이, 그라스울 패널, 우레탄폼 패널, 샌드위치 패널, 유리 칸막이를 선정 하였고, ISO 9705시험 기준에 따라 버너에 점화 전 측정 장치와 데이터의 기록을 시작하여 120 s간 유지시켜 안정화를 취하고, 점화 후 600 s 동안 100 kW, 이후 600 s 동안 300 kW까지 증가하였다가 종료 후 180 s동안 관찰하여 이면부로의 화재 위험성 및 벽체의 화재 패턴을 분석하였다. 점화원에서 발생된 열량으로 인한 최대 이면온도는 SGP 칸막이 67.7 ℃, 스터드 칸막이 55.1 ℃, 그라스울 패널 52.4 ℃, 샌드위치 패널 727.4 ℃, 우레탄폼 패널 561 ℃, 유리 칸막이 630.5 ℃로 측정되었다. 샌드위치 패널과 우레탄폼 패널의 경우 내장재에 용융으로 인한 가연성 가스의 폭발 현상이 발생하였고 강화유리는 수열부와 비수열부의 온도차이로 인하여 유리가 파열되며 인접구획실로의 화재 위험성이 높은 것으로 판단된다.

폭발하중 이력 특성에 따른 판 구조물의 동적응답 평가 - Part A: 폭발하중 특징 및 재하속도의 영향 분석 - (Dynamic Response of Plate Structure Subject to the Characteristics of Explosion Load Profiles - Part A: Analysis for the Explosion Load Characteristics and the Effect of Explosion Loading Rate on Structural Response -)

  • 강기엽;최광호;류용희;최재웅;이제명
    • 한국전산구조공학회논문집
    • /
    • 제28권2호
    • /
    • pp.187-195
    • /
    • 2015
  • 가스 생산용 해양플랜트 설비에서 발생할 수 있는 폭발사고의 경우, 구조 시스템의 기하학적 특성이나, 바람, 가스 누출율 등과 같은 환경적 조건에 의해 피해 규모의 범위가 상당하다. 따라서 폭발파에 의한 구조 부재의 응답을 분석하기 위해서는 이러한 조건들을 고려한 가스폭발 수치해석 과정이 반드시 필요하다. 본 연구에서는 FPSO 탑사이드의 형상 및 장비 배치와 같은 세부적인 부분까지 고려하여 폭발해석을 수행하였으며, 이를 바탕으로 획득한 하중 이력들의 특성을 분석하였다. 또한 다양한 형태로 나타나는 폭발하중 이력들 중 구조물 손상에 직접적으로 영향을 미칠 수 있는 최대 압력과 지속시간들을 고려하여 유한요소해석 시 하중조건으로 적용한 후, 부재의 응답특성에 관한 분석을 수행하였다. 유한요소해석 모델은 실제 구조물에 적용이 가능하고, 복잡한 형상을 이상화한 단 자유도 및 다 자유도 모델을 사용하였다. 정 압력 및 부 압력단계의 최대 압력이 증가함에 따라 구조 부재의 최대 응답이 증가하였고, 부 압단계에서 하중 지속시간이 증가함에 따라 구조물의 최대 변위가 증가는 경향을 보였다.

고강도 철근을 사용한 철근콘크리트 패널의 비선형 유한요소해석 (Nonlinear Finite Element Analysis of the Reinforced Concrete Panel using High-Strength Reinforcing Bar)

  • 천주현;성대정;조홍재;조재열;신현목
    • 콘크리트학회논문집
    • /
    • 제27권5호
    • /
    • pp.481-488
    • /
    • 2015
  • 이 연구에서는 고강도 철근이 사용된 철근콘크리트 패널 실험체의 파괴에 이르기까지의 전반적인 거동특성을 합리적으로 예측하기위한 해석적 방안을 마련하는 것을 목표로 한다. 다양한 하중 조건과 설계 변수하에서 실제 격납구조물 벽체 두께의 1/3 규모를 갖는 총 12개의 철근콘크리트 패널 실험체를 검증 대상으로 선정하여 저자 등에 의해 개발된 비선형 유한요소해석 프로그램(RCAHEST)을 적용하여 해석을 수행하였다. 균열 발생 시점에서의 전단 강도와 최대 전단 강도에 대한 실험과 해석으로부터의 평균과 변동계수는 각각 1.03과 12% 및 0.97과 9%정도로 예측되었다. 최대 전단 강도에서의 전단 변형률에 대한 실험과 해석으로부터의 결과는 평균과 변동계수가 각각 0.96과 30% 정도로 예측되었다. 결과를 종합해 볼 때, 이 연구에서 새로운 수정한 구성방정식을 적용한 해석프로그램은 그 해석 결과에 비교적 높은 신뢰도를 확보하고 있는 것으로 판단된다.

ECC 날개벽 요소로 보강된 비내진상세를 갖는 철근콘크리트 골조의 내진성능 (The Seismic Performance of Non-Ductile Reinforced Concrete (RC) Frames with Engineered Cementitious Composite (ECC) Wing Panel Elements)

  • 강대현;옥일석;윤현도;김재환;양일승
    • 콘크리트학회논문집
    • /
    • 제27권5호
    • /
    • pp.541-549
    • /
    • 2015
  • 본 논문에서는 고인성 시멘트 복합체(ECC)가 적용된 날개벽 요소의 면 접합방식에 따른 평가를 실시하였다. 또한 비내진상세를 갖는 RC 골조에 ECC날개벽 요소 보강하여 보강 유무에 따른 내진성능평가를 실시하였다. 면 접합 방법에 따른 거동 특성을 비교하기 위하여 2면 접합은 상 하부 보에 3면 접합은 상 하부 보 및 기둥에 접합하여 실험을 실시 하였다. 또한 비내진상세를 갖는 기존 구조체와의 일체로 거동하는 합성거동을 위해 3면 접합 방식으로 ECC날개벽 요소 보강을 실시하였다. ECC날개벽 요소 실험과 골조 실험은 점증되는 층간변위에 따라 2회씩 반복가력하여 실험을 진행하였다. 실험 결과 ECC 날개벽 요소 실험체의 경우 3면 접합이 2면 접합보다 우수한 내진성능 나타내었다. 각각의 실험체는 우수한 재료 특성으로 인하여 미세한 다수의 균열이 ECC날개벽 요소 전면에 폭넓게 분포하였다. 또한 보통 콘크리트와 달리 최대강도 이후 연성적인 거동을 나타내었으며, 이에 우수한 에너지소산능력을 나타내었다. ECC날개벽 요소를 보강한 실험체와 기존 골조에서는 ECC날개벽 요소 보강에 따른 최대강도 이후 연성적인 거동을 나타내었다. 이에 따라 에너지소산능력이 증가하였으며, 강성저하 또한 완만한 곡선을 나타내며 기존 골조보다 우수한 내진특성을 나타내었다. 이에 ECC 날개벽 요소의 보강이 비내진상세를 갖는 구조체에 우수한 내진 특성을 부여하는 판단된다.