Wind profile management and blockage assessment for a new 12-fan Wall of Wind facility at FIU

  • Aly, Aly Mousaad;Chowdhury, Arindam Gan;Bitsuamlak, Girma
    • Wind and Structures
    • /
    • v.14 no.4
    • /
    • pp.285-300
    • /
    • 2011
  • Researchers at the International Hurricane Research Center (IHRC), Florida International University (FIU), are working in stages on the construction of a large state-of-the-art Wall of Wind (WoW) facility to support research in the area of Wind Engineering. In this paper, the challenges of simulating hurricane winds for the WoW are presented and investigated based on a scale model study. Three wind profiles were simulated using airfoils, and/or adjustable planks mechanism with and without grids. Evaluations of flow characteristics were performed in order to enhance the WoW's flow simulation capabilities. Characteristics of the simulated wind fields are compared to the results obtained from a study using computational fluid dynamics (CFD) and also validated via pressure measurements on small-scale models of the Silsoe cube building. Optimal scale of the test model and its optimal distance from the WoW contraction exit are determined - which are two important aspects for testing using an open jet facility such as the WoW. The main objective of this study is to further the understanding of the WoW capabilities and the characteristics of its test section by means of intensive tests and validations at small scale in order to apply this knowledge to the design of the full-scale WoW and for future wind engineering testing.

Wind tunnel study of wind loading on rectangular louvered panels

  • Zuo, D.;Letchford, C.W.;Wayne, S.
    • Wind and Structures
    • /
    • v.14 no.5
    • /
    • pp.449-463
    • /
    • 2011
  • Drag forces on a rectangular louvered panel, both as a free-standing structure and as a component in a generic low-rise building model, were obtained in a wind tunnel study. When tested in a building model, the porosity ratio of the wall opposite the louvered panel was varied to investigate its effect on the loading of the louvered panel. Both mean and pseudo-steady drag coefficients were obtained. Comparisons with the provisions for porous walls in contemporary loading standards indicate that for some opposite wall porosity ratios, the standards specify significantly different wind loads (larger and smaller) than obtained from this wind tunnel study.

UNSTEADY WALL INTERFERENCE EFFECT ON FLOWS AROUND AN OSCILLATING AIRFOIL IN CLOSED TEST-SECTION WIND TUNNELS (폐쇄형 풍동 시험부내의 진동하는 익형 주위 유동에 대한 비정상 벽면효과 연구)

  • Kang Seung-Hee;Kwon Oh Joon;Hong Seung-Kyu
    • Journal of computational fluids engineering
    • /
    • v.10 no.2
    • /
    • pp.60-68
    • /
    • 2005
  • For study on the unsteady wall interference effect, flows around a forced oscillating airfoil in closed test-section wind tunnels have been numerically investigated by solving compressible Navier-Stokes equations. The numerical scheme is based on a node-based finite-volume method with the Roe's flux-difference splitting and an implicit time-integration method coupled with dual time-step sub-iteration. The Spalart-Allmaras one-equation model is employed for the turbulence effect. The computed results of the oscillating airfoil having a thin wake showed that the lift curve slope is increased and the magnitude of hysteresis loop is reduced by the interference effects. Since the vortex around the airfoil is generated and convected downstream faster than the free-air condition, the phase of lift, drag and pitching moment coefficients was shifted. The pressure on the test section wall shows harmonic terms having the oscillating frequency contained in the wail effect.

Estimation Method of the Design Wind Load of Soundproof Wall Using GIS (GIS를 이용한 방음벽의 설계풍하중 산정방법)

  • Lee, Dong-Ho;Choi, Se-Hyu
    • Spatial Information Research
    • /
    • v.23 no.5
    • /
    • pp.75-85
    • /
    • 2015
  • Recently deformed or destroyed of soundproof wall by local winds and typhoon has increased. This research proposed the estimation method of the design wind load of soundproof wall using spatial information analysis based on 1:5,000 digital map and performed comparative analysis with actual application cases. According to the result of quantitative evaluation using GIS, the surface roughness in the downtown area packed with buildings was III and the surface roughness in the suburban district with a relatively small number of buildings was II and the surface roughness in the district packed with open areas and typical farmhouses was I. This shows that the wind load of the soundproof walls reflecting the actual surface conditions was estimated. If the quantitative GIS analysis presented in this study is applied to wind-resistant design of soundproof walls, it is supposed that this will be helpful in more rational wind-resistant design by remedying the existing problem in which the wind load varies depending on designer's subjectivity.

Prediction of the Individual Reentering Rate of a Cooling Tower within it'S Bank Installed on Building Roof (옥상설치 냉각탑에서의 토출공기 재유입량 예측)

  • Moon, Sun-Ae;Heo, Jin-Hyuk;Choi, Choong-Hyun;Yi, Kang-Soon;Lee, Jae-Heon;Yoo, Ho-Seon;Lee, Tae-Gu
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.445-450
    • /
    • 2005
  • In this paper, the individual reentering rate of the cooling towers installed on a building roof is investigated considering the wind direction and louver wall installation. As the western wind with 5 m/s flows and the louver wall is not installed around the roof. the reentering rate of the cooling towers is predicted about 20%. However the reentering rate is simulated about 5% when the louver wall is installed around the roof. As the southern wind with 5 m/s flows and the louver wall is not installed, the reentering rate of the cooling tower is predicted about 30%.On the contrary, the reentering rate is simulated about 15% when the louver is installed. As a result, if there is no louver wall installed around the roof, the falloff of the cooling capacity would be serious by the reentering of the discharge air. The installation of the louver wall is strongly recommended to prevent the discharge air reentering.

  • PDF

Economic Evaluation according to Construction and Curtain Wall Mullion as a Rail (멀리온을 레일로 활용한 커튼월의 시공에 따른 경제성 평가)

  • Jung, Ui-In;Hong, Sang-Hun;Kong, Hee-Min;Kim, Bong-Joo;Yeom, Sang-Su;Kang, Hui-Tae
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2016.05a
    • /
    • pp.17-18
    • /
    • 2016
  • Today, many kind of buildings are higher than those of previous generations, and Curtain Wall is adapted broadly as an outer wall material. But weather and environmental condition could cause problems in curtain wall construction in most construction projects. High wind speed and unplanned lifting equipment's allocation could cause construction delay and cost increase. To solve these problems, we suggest using a curtain wall mullion as a rail to lift curtain wall which is less affected wind speed. And we would like to show a preliminary data of its economic advantage evaluation.

  • PDF

Navier-Stokes Analysis of Pitching Delta Wings in a Wind Tunnel

  • Lee, Yung-Gyo
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.2 no.2
    • /
    • pp.28-38
    • /
    • 2001
  • A numerical method for the assessment and correction of tunnel wall interference effects on forced-oscillation testing is presented. The method is based on the wall pressure signature method using computed wall pressure distributions. The wall pressure field is computed using unsteady three-dimensional full Navier-Stokes solver for a 70-degree pitching delta wing in a wind tunnel. Approximately-factorized alternate direction implicit (AF-ADI) scheme is advanced in time by solving block tri-diagonal matrices. The algebraic Baldwin-Lomax turbulence, model is included to simulate the turbulent flow effect. Also, dual time sub-iteration with, local, time stepping is implemented to improve the convergence. The computed wall pressure field is then imposed as boundary conditions for Euler re-simulation to obtain the interference flow field. The static computation shows good agreement with experiments. The dynamic computation demonstrates reasonable physical phenomena with a good convergence history. The effects of the tunnel wall in upwash and blockage are analyzed using the computed interference flow field for several reduced frequencies and amplitudes. The corrected results by pressure signature method agree well with the results of free air conditions.

  • PDF

CFD ANALYSIS OF SUBSONIC AIRFOIL WIND TUNNEL TEST (아음속 익형 풍동시험 전산해석)

  • Kim, C.W.;Lee, Y.G.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2007.10a
    • /
    • pp.167-170
    • /
    • 2007
  • In the present paper, wall correction method is reviewed and applied to the numerical experimental results obtained at the wind tunnel condition. The corrected lift coefficient agrees well with the reference data generated from the grid having very far boundary. However the corrected drag coefficient presents some deviation from the reference data.

  • PDF

A Study on Wall Interference Effect Around the Wind Turbine Airfoil (풍력터빈 에어포일 주위의 벽면효과에 관한 연구)

  • Cho, Hwan-Kee;Kang, Seung-Hee;Ryu, Ki-Wahn;Lee, Jun-Shin
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.40 no.6
    • /
    • pp.485-491
    • /
    • 2012
  • The wall interference effects around the wind-turbine airfoil are experimentally investigated at low Reynolds numbers in a closed test-section wind tunnel. The test is performed at free-stream velocities from 10 to 31 m/s, which correspond to Reynolds numbers ranging from $1.5{\times}10^5$ to $4.6{\times}10^5$ based on chord of the airfoil. The blockage-area ratios, which is the ratio of the chord to the test-section width, are 27.8%, 38.5%, 41.7%, 45.5%, and 55.6%. The test results for the airfoil show that the transition point on the airfoil surface tends to move backward due to wall interference. The wall pressures for an adequate interference correction by a measured-boundary-condition method are desirable more than three times region of the chord before and after around the reference center.

Wind Tunnel Wall Interference Correction Method for Helicopter Rotor Tests with Closed and open Test Sections (헬리콥터 로터의 폐쇄형 및 개방형 풍동시험 벽면효과 보정기법 연구)

  • Lee, Hyeon-Jung;Jang, Jong-Youn;Lee, Seung-Soo;Kim, Beom-Soo;Song, Keun-Woong
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.36 no.7
    • /
    • pp.621-627
    • /
    • 2008
  • Aerodynamic data measured in a wind tunnel has inevitable errors due to the presence of the wind tunnel walls. These unwanted interference effects must be corrected for the wall interference free aerodynamic data. Streamline curvature effects are caused by straightening of streamlines due to wind tunnel walls. Classical Glauert's correction method that is a standard method for fixed wing aircraft is not suitable for rotary wing aircraft. In this paper, Heyson's correction method of which wake model is compatible with rotors is used to correct the rotor shaft angle as well as the dynamic pressure. The results of Heyson's method are compared with Glauert's correction method.