• 제목/요약/키워드: wall of wind

검색결과 344건 처리시간 0.024초

아치형 단동하우스의 풍력계수 분포에 관한 연구 (Distribution of Wind Force Coefficients on the Single-span Arched House)

  • 이석건;이현우
    • 생물환경조절학회지
    • /
    • 제1권1호
    • /
    • pp.28-36
    • /
    • 1992
  • The wind pressure distributions were analyzed to provide fundamental criteria for the structural design on e single-span arched house according to the wind directions through the wind tunnel experiment. In order to investigate the wind force distributions, the variation of the wind force coefficients, the mean wind force coefficients, the drag force coefficients and the lift force coefficients were estimated by using the experimental data. The results obtained are as follows: 1. When the wind direction was normal to the wall, the maximum positive wind pressure along the height of the wall occurred approximately at two-thirds of the wall height because of the effects of boundary layer flow. 2. When the wind direction was 30$^{\circ}$ to the wall, the maximum positive wind force occurred at the windward edge of the wall. When the wind direction was parallel to the wall, the maximum negative wind force occurred at the windward edge of the wall. 3. The maximum negative wind force along the width of the roof appeared around the width ratio, 0.4, and that along the length of the roof appeared around the length ratio, 0.5. 4. According to the results of the mean wind force coefficients analysis, the maximum negative wind force occurred on the roof at the wind direction of 30$^{\circ}$. 5. The wind forces at the wind direction of 30$^{\circ}$ instead of 0$^{\circ}$ are recommended in the structural design of supports for a house. 6. To prevent partial damage of a house structure by wind forces, the local wind forces should be considered to the structural design of a house.

  • PDF

Effect of hanging-type sand fence on characteristics of wind-sand flow fields

  • Cheng, Jian-jun;Lei, Jia-qiang;Li, Sheng-yu;Wang, Hai-feng
    • Wind and Structures
    • /
    • 제22권5호
    • /
    • pp.555-571
    • /
    • 2016
  • A hanging-type sand-retaining wall is a very common sand-blocking fence structure used to prevent sand movement. This type of wall is widely used along the Qinghai-Tibet and Gobi desert railways in Xinjiang, Western China. To analyze the characteristics of wind-sand flow fields under the effect of such a sand fence structure, a wind tunnel test and a field test were carried out. The wind tunnel test showed the zoning characteristics of the flow fields under the effect of the hanging-type sand-retaining wall, and the field test provided the sediment transport data for effective wind-proof interval and the sand resistance data in the front and behind the sand-retaining wall. The consistency of the wind-sand flow fields with the spatial distribution characteristic of wind-carried sand motion was verified by the correspondences of the acceleration zone in the flow field and the negative elevation points of the percentage variations of the sand collection rate. The spatial distribution characteristic of the field sand collection data further showed the spatial structural characteristic of the sandy air currents under the action of the hanging-type sand-retaining wall and the sand resistance characteristic of the sand-retaining wall. This systematic study on the wind-sand flow fields under the control of the hanging-type sand-retaining wall provides a theoretical basis for the rational layout of sand control engineering systems and the efficient utilization of a hanging-type sand-retaining wall.

Full-scale experimental evaluation of a panelized brick veneer wall system under simulated wind loading

  • Liang, Jianhai;Memari, Ali M.
    • Structural Engineering and Mechanics
    • /
    • 제38권1호
    • /
    • pp.99-123
    • /
    • 2011
  • Brick veneer over steel stud backup wall is lighter and easier to construct compared to brick veneer over concrete masonry backup wall. However, due to the relatively low stiffness of the steel stud backup, the brick veneer tends to crack under wind load. This paper briefly introduces a new panelized brick veneer with steel frame backup wall system that is developed to potentially address this problem. The experimental study of the performance of this system under simulated wind loading is discussed in detail. The test setup details and the test specimens are introduced, results of major interests are presented, and performance of the new system is evaluated based on the test results.

ANSYS와 CFX를 이용한 방풍벽의 구조 안전성 분석 (Analysis of the Structural Safety of a Wind-Protecting Wall Using ANSYS/CFX)

  • 염성현;김철수;최영돈
    • 생물환경조절학회지
    • /
    • 제15권2호
    • /
    • pp.138-148
    • /
    • 2006
  • 대립계 포도 비가림하우스에 부착된 일체형 방풍벽과 노지에 설치된 분리형 방풍벽의 구조 안전성을 설계풍속 $30.9m{\cdot}s^{-1}$$50m{\cdot}s^{-1}$ 조건에서 각각 분석하였다. 비닐하우스 부착형 방풍벽의 경우, 방풍벽을 설치했을 때 방풍벽의 경사각이 측면부의 유동분포에 미미한 변화를 주어 측면부가 받는 풍압면적이 다소 감소하는 것으로 나타났으나 큰 차이를 보이지는 않았다. 그러나 구조강도 측면에서는 방풍벽 설치를 위한 부가적인 파이프 투입 효과로 약 11%정도 구조 안전성이 향상되는 것으로 분석되었다. 주기둥 간격이 3m인 분리형 방풍벽의 경우,대형 태풍수준인 $50m{\cdot}s^{-1}$에서 구조적으로 불안정한 것으로 나타났으며 분리형 방풍벽의 이론적 고찰 결과와 해석 결과와는 큰 차이를 보여 3차원으로 구성된 구조물의 2차원 모델 시 그 정확성에 한계가 있음을 알 수 있었다. 추후 분리형 방풍벽의 효용성을 증대하기 위하여 최적 파이프 규격 설정에 관한 세부적인 연구가 필요할 것으로 판단되며 비닐하우스 부착형 방풍벽의 경우, 태풍으로 인한 비닐하우스 피해 발생 시 정밀한 피해실태 조사를 통하여 분석 결과의 정확성을 향상시킬 수 있는 구조 안전성 분석 기법 개발에 관한 연구가 필요한 것으로 판단되었다.

아치형 단동온실의 최적설계를 위한 풍력계수분포도의 분석 (An Analysis of Wind Force Coefficient Distributions for Optimum Design of Single-Span Arched Greenhouse)

  • 이석건;이현우;권무남
    • 생물환경조절학회지
    • /
    • 제4권1호
    • /
    • pp.1-8
    • /
    • 1995
  • One of the most destructive forces around greenhouses is wind. Wind loads can be obtained by multiplying velocity pressure by dimensionless wind force coefficient. Generally, wind force coefficients can be determined by wind tunnel experiments. The wind force coefficient distribution on a single - span arched greenhouse was estimated using experimental data and compared with reported values from various countries. The results obtained are as follows : 1. The coefficients obtained from this study agree with the values proposed by G. L. Nelson except about 0.5 of difference in the middle region of roof section. This discrepancy is mainly attributed to the dissimilarity of experimental conditions (or wind tunnel test such as Reynolds number, type of terrain, surface roughness of model, location of the lapping and measuring methods. 2. Considering that the wind force coefficients are varied along the height of a wall at wind direction perpendicular to wall, structural analysis using subdivided wind force coefficient distribution is more resonable for wall. 3. It is recommendable that wind force coefficient distribution on a roof should take more subdivision than the existing four equal divisions for more accurate structural design. 4. Structural design using wind forces close to real values is more advantageous in safety and expense.

  • PDF

비정상유동 실험시의 비정상 적응벽면 모델의 수치적 연구 (Numerical Investigation of the Unsteady Adaptive Wall Models in the Unsteady Wind Tunnel Testing)

  • 장병희;장근식
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 1995년도 추계 학술대회논문집
    • /
    • pp.219-224
    • /
    • 1995
  • The adaptive wall test section has distinct advantage over the other devices for reduction of wall interference in the wind tunnel testing. For two-dimensional steady flows the wall adaption strategy has been well established and, in some extent, has been effectively applied to three-dimensional steady flows. For unsteady testing, the wall adaptation is conceptually possible but has never been realized in the wind tunnel experiment. In this study, relatively simple adaptive wall models have been proposed and evaluated through numerical tests. The effect of Mach number, frequency, and amplitude of pitching oscillation on the wall interference reduction has been also studied.

  • PDF

Study on wind-induced vibration response of Jiayuguan wooden building

  • Teng Y. Xue;Hong B. Liu;Ting Zhou;Xin C. Chen;Xiang Zhang;Zhi P. Zou
    • Wind and Structures
    • /
    • 제37권3호
    • /
    • pp.245-254
    • /
    • 2023
  • In this paper, the wind-induced response of Jiayuguan wooden building (world cultural heritage) in Northwest China was studied. ANSYS finite element software was used to establish four kinds of building models under different working conditions and carry out modal analysis. The simulation results were compared with the field dynamic test results, obtaining the model which reflects the real vibration characteristics of the wooden tower. Time history data of fluctuating wind speed was obtained by MATLAB programming. Time domain method and ANSYS were used to analyze the wind-induced vibration response time history of Jiayuguan wooden building, obtaining the displacement time history curve of the structure. It was suggested that the wind-induced vibration coefficient of Jiayuguan wooden building is 1.76. Through analysis of the performance of the building under equivalent static wind load, the maximum displacement occurs in the three-story wall, gold column and the whole roof area, and the maximum displacement of the building is 5.39 cm. The ratio of the maximum stress value to the allowable value of wood tensile strength is 45 %. The research results can provide reference for the wind resistant design and protection of ancient buildings with similar structure to Jiayuguan wooden tower.

Unsteady wind loading on a wall

  • Baker, C.J.
    • Wind and Structures
    • /
    • 제4권5호
    • /
    • pp.413-440
    • /
    • 2001
  • This paper presents an extensive analysis of unsteady wind loading data on a 18 m long and 2 m high wall in a rural environment, with the wind at a range of angles to the wall normal. The data is firstly analyzed using standard statistical techniques (moments of probability distributions, auto- and cross-correlations, auto- and cross-spectra etc.). The analysis is taken further using a variety of less conventional methods - conditional sampling, proper orthogonal decomposition and wavelet analysis. It is shown that, even though the geometry is simple, the nature of the unsteady flow is surprisingly complex. The fluctuating pressures on the front face of the wall are to a great extent caused by the turbulent fluctuations in the upstream flow, and reflect the oncoming flow structures. The results further suggest that there are distinct structures in the oncoming flow with a variety of scales, and that the second order quasi-steady approach can predict the pressure fluctuations quite well. The fluctuating pressures on the rear face are also influenced by the fluctuations in the oncoming turbulence, but also by unsteady fluctuations due to wake unsteadiness. These fluctuations have a greater temporal and spatial coherence than on the front face and the quasi-steady method over-predicts the extent of these fluctuations. Finally the results are used to check some assumptions made in the current UK wind loading code of practice.

Computational evaluation of wind loads on buildings: a review

  • Dagnew, Agerneh K.;Bitsuamlak, Girma T.
    • Wind and Structures
    • /
    • 제16권6호
    • /
    • pp.629-660
    • /
    • 2013
  • This paper reviews the current state-of-the-art in the numerical evaluation of wind loads on buildings. Important aspects of numerical modeling including (i) turbulence modeling, (ii) inflow boundary conditions, (iii) ground surface roughness, (iv) near wall treatments, and (vi) quantification of wind loads using the techniques of computational fluid dynamics (CFD) are summarized. Relative advantages of Large Eddy Simulation (LES) over Reynolds Averaged Navier-Stokes (RANS) and hybrid RANS-LES over LES are discussed based on physical realism and ease of application for wind load evaluation. Overall LES based simulations seem suitable for wind load evaluation. A need for computational wind load validations in comparison with experimental or field data is emphasized. A comparative study among numerical and experimental wind load evaluation on buildings demonstrated generally good agreements on the mean values, but more work is imperative for accurate peak design wind load evaluations. Particularly more research is needed on transient inlet boundaries and near wall modeling related issues.

저탄장 시설에 설치된 방풍벽 높이에 따른 비산탄진 확산특성에 관한 수치해석 (Numerical Investigation on Influence of Windbreak Wall Height on Dust Scattering Characteristics)

  • 정찬호;이진운;신동환;김명민;이성혁
    • 한국분무공학회지
    • /
    • 제19권3호
    • /
    • pp.136-141
    • /
    • 2014
  • This study reports numerically the characteristics of dust scattering around the coal storage pile yards, substantially affected by the windbreak wall height. The dust scattering is closely associated with the frictional effect of wind flows as well as the pressure variation that consequently affect the dust particle behavior. In the present study, with the use of the commercial code of FLUENT, the distribution of wind velocity and pressure are predicted around coal storage pile yard for four different heights of the wind break wall. From the results, it was found that for the case 1 with the outer windbreak wall height of 3 m and inner windbreak wall height of 6 m, the amount of scattering dust for a year was estimated to be 1451 kg, whereas for the case 4 where a height of outer windbreak wall is 10 m and a height of inner windbreak wall is 16 m, the amount of scattering dust for a year was 358 kg. It shows that the dust scattering can be reduced by 75%, indicating important role of windbreak wall height on particle scattering. The numerical results would be useful in decision of the appropriate height of windbreak wall for decreasing the amount of scattering dust under various environmental conditions.