• Title/Summary/Keyword: wall impingement model

Search Result 51, Processing Time 0.024 seconds

A Experimental/Numerical Study of Behaviors of Spray Impinging on the Diesel Combustion Chamber Wall (디젤 연소실 벽면에 충돌하는 분무거동에 관한 실험적/수치적 연구)

  • 박정규;원석규;원영호
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.8 no.5
    • /
    • pp.86-95
    • /
    • 2000
  • A modified spray impingement model has been developed, which is assessed against experiments for the impinging sprays on the small combustion chamber at various gas pressures. To investigate spray behaviors in the diesel combustion chamber, a transparent constant-volume chamber is made which is similar to the combustion chamber of the real diesel engine. The chamber is pressurized by N2 gas from 0 bar to 20 bar to find the effects of ambient pressures. The behaviors of spray injected into this chamber and dispersed after impingement on the cylinder wall is measured two-dimensionally using laser sheet Mie scattering method. The physical submodels have been properly modified to improve the prediction capability of original KIVA code to describe the spray behaviors after impingement on the curved cylinder wall. In terms of spray dynamics and evolution. numerical results give qualitatively good agreements with experimental data.

  • PDF

Development of a general purpose thermo/fluid flow analysis program NUFLEX with heat transfer analy sis model of impinging liquid film (충돌분무 액막의 열전달 해석모델을 고려한 범용 열/유체 프로그램 NUFLEX의 개발)

  • Kim, Hyun-Jeong;Ro, Kyoung-Chul;Ryou, Hong-Sun;Hur, Nahm-Keon
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.71-74
    • /
    • 2008
  • NUFLEX is a general purpose thermo/fluid flow analysis program which has various physical models including spray. In NUFLEX, spray models are composed of breakup and collision models of droplet. However, in case of diesel engine, interaction between wall-film and impingement model considering heat transfer is not coded in NUFLEX. In this study, Lee & Ryou impingement & wall-film model considering heat transfer is applied to NUFLEX. For the verification of this NUFLEX program, numerical results are compared with experimental data. Differences of film thickness and radius between numerical results and experimental data are within 10% error range. The results show that NUFLEX can be used for comprehensive analysis of spray phenomena.

  • PDF

Modeling of Spray-Wall Interactions Considering Liquid Film Formation (액막형성을 고려한 분무-벽 상호작용에 대한 모델)

  • Lee, Seong-Hyuk;Ryou, Hong-Sun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.7
    • /
    • pp.1010-1019
    • /
    • 2000
  • The main purpose of this article is to propose and assess a new spray impingement model considering film formation, which is capable of describing the droplet distribution and film flows in direct injection diesel engines. The spray-wall interaction model includes several mathematical formulae, newly made by the energy conservation law and some experimental results. The model consists of three representative regimes, rebound, deposition and splash. In addition, the film flow is described in the present model by solving the continuity and momentum equations for film flows using the integral method. To assess the new spray impingement model, the calculated results using the new model are compared with several experimental data for the normally impinging diesel sprays. The film model is also validated through comparing film radius and thickness against experimental data. The results show that the new model is generally in better agreement with experimental data and acceptable for prediction of the film radius and thickness.

Numerical study for the characteristics of diesel spray impinging on a wall (벽에 충돌하는 디젤분무의 특성에 대한 수치적 연구)

  • Yang, Hui-Cheon;Jeong, Dong-Hwa;Yu, Hong-Seon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.22 no.5
    • /
    • pp.661-671
    • /
    • 1998
  • It is unavoidable that the fuel spray impinges on the wall of piston cavity in a compact high-pressure D.I. diesel engine. Therefore the characteristics of impinging spray are the very significant information on the consideration and the simulation of its combustion processes including the formation mechanism of exhaust emission and the design of the combustion chamber. In this paper, the numerical simulation was performed to study the characteristics of impinging spray. The spray-wall impingement model used is Watkins and Park's model. Calculation parameters are the inclination angles and the ambient pressures. As the inclination angle increases, the impinging spray develops mainly to the direction of the downstream and scarcely flows to that of the upstream. The shape on the wall of the impinging spray is the circle in the case of the normal impingement, while it is the ellipse in that of the oblique impingement. As the ambient pressure increases, the growth of impinging spray on the wall in the radial direction decreases owing to the increase in the resistance of the ambient.

Numerical Study of Impinging Sprays Considering Anisotropic Characteristics of Turbulence (비등방성 난류특성을 고려한 분무의 벽면충돌 현상에 대한 수치해석 연구)

  • 고권현;유홍선;이성혁
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.11 no.3
    • /
    • pp.77-84
    • /
    • 2003
  • It is an aim of this study to perform extensive numerical study for analyzing the anisotropic turbulence effects on spatial and temporal behaviors of diesel sprays after wall impingement. The turbulence model of Durbin is used for comparisons with the $k-\varepsilon$ model. The turbulence-induced dispersions of droplets are considered to describe the anisotropy of turbulence effectively and the spray/wall interactions are simulated using the model of Lee and Ryou. The present study investigates the internal structures of impinging diesel sprays such as Sauter mean diameter (SMD), loca1 droplet velocities, and local gas velocities and also compares the results predicted by two turbulence models with the experimental data. The Durbin's model considering the anisotropy of turbulence predicts both gas and droplet tangential velocities better than the$k-\varepsilon$ model does. It is concluded that the anisotropy of turbulence should be considered in simulating impinging diesel sprays.

A Study on the Wall Thinning Range according to modified Extraction Nozzle Design in High Pressure Feedwater Heater (고압 급수가열기 추기노즐 설계변경에 따른 감육 범위 연구)

  • Park, Sang-Hoon;Yoo, Il-Gon;Kim, Kyung-Hoon;Hwang, Kyeong-Mo
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.847-852
    • /
    • 2009
  • Feedwater heaters of many nuclear power plants have recently experienced severe wall thinning damange, which will increase as operating time progresses. Several nuclear power plants in Korea have experienced wall thinning damage in the area around the impingement baffle inside feed-water heater installed downstream of the turbine extraction stream line. At that point, the extract steam from the turbine is two phase fluid at high temperature, high pressure, and high speed. Since it flows to reverse direction after impinging the impingement baffle, the shell wall of feedwater heaters may be affected by flow-accelerated corrosion. In this paper, to compare wall thinning range according to change entrance nozzle diameter and position with reference numerical analysis model's wall thinning range, various numerical analysis models applied. In case of changing diameter, four different diameter is applied. And a side of nozzle position, two different position-vertical type and parallel type-is applied. And then this paper describes operation of numerical analysis which is composed similar condition with real feed water heater. In conclusion, this study shows effective design for shall wall thinning by changing nozzle diameter and position.

  • PDF

Eulerian-based Numerical Modeling for Impingement Prediction of Supercooled Large Droplets (과냉각대형액적 충돌예측을 위한 오일러리안 기반 수치 모델링)

  • Jung, Sung-Ki;Kim, Ji-Hong
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.40 no.8
    • /
    • pp.647-654
    • /
    • 2012
  • Supercooled large droplet issues in aircraft icing have been continually reported due to the important safety considerations. In order to simulate the impingement behavior of large droplets, a two-dimensional and compressible Navier-Stokes code was developed to determine the flow field around the test model. Also, the Eulerian-based droplet impingement model including a semi-empirical approach for the droplet-wall interaction process and droplet break-up was developed. In particular, the droplet-wall interactions were considered as numerical boundary conditions for the droplet impingement simulation in the supercooled large droplet conditions. Finally, the present results were compared with the experimental test data and the LEWICE results. The droplet impingement area and maximum collection efficiency values between present results and wind tunnel data were in good agreements. Otherwise, the inclination of collection efficiency of the present result is over-predicted than the wind tunnel data around a lower surface of the NACA 23012 airfoil.

Wall-Droplet Interaction Modeling and Comparative Study on Deformation Models for the Improvement of Icing Analysis Under SLD Conditions (SLD 조건에서 착빙 해석 정확도 개선을 위한 Wall-Droplet Interaction 수치 모델링 및 Deformation 모델 비교 연구)

  • Bae, Jinkyu;Yee, Kwanjung
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.48 no.4
    • /
    • pp.255-267
    • /
    • 2020
  • Under SLD conditions, due to the large size of droplets, physical phenomena such as wall-droplet interaction and deformation have a significant effect on the icing process. Accordingly, many studies have been conducted in order to computationally simulate SLD effects. As one of the efforts, post-processing method have been proposed to describe wall-droplet interaction effect, which modified collection efficiency using Wright model. However, since the model doesn't properly consider the wall condition, it still overestimated collection efficiency and impingement limit. To solve this problem, impingement areas were divided into 3 different regions, and the post-processing method was introduced with the new wall-droplet interaction model developed based on Bai and Gosman rebound model. In order to consider the effect of deformation, the most suitable model was selected by comparing the deformation models used in the various icing codes. As a result, the modified post-processing method showed improved accuracy in predicting the impingement limits and collection efficiency by further estimating mass flux loss due to rebound, and it was observed that the result was the closest to the experimental data when the deformation effect was included by using Wiegand model.

Study on Smoke Prediction in Heavy-duty Diesel Engine (대형 디젤기관에서 매연가스 예측에 관한 연구)

  • Baik, Doo-Sung;Lee, Jong-Sun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.4
    • /
    • pp.865-870
    • /
    • 2008
  • The effects of exhaust gas recirculation (ECR) on smoke emissions in heavy duty diesel engine are numerically studied by using KIVA-3V CFD code. For the analysis, RNG k-$\varepsilon$ turbulence model was given as a governing equation, and mathematical models of Tab, Wave, Watkins-Park, Nagle-Strikland were applied to describe physical process of droplet breakup, atomization, wall impingement and smoke respectively.

A Study on the Fluid Mixing Analysis for Proving Shell Wall Thinning of a Feedwater Heater (급수가열기 동체 감육 현상 규명을 위한 유동해석 연구)

  • Kim, Kyung-Hoon;Hwang, Kyeong-Mo;Kim, Sang-Nyung
    • Journal of ILASS-Korea
    • /
    • v.9 no.4
    • /
    • pp.24-30
    • /
    • 2004
  • Feedwater flowing tube side of number 5 high pressure feedwatrr heaters was heated by extracting steam from high pressure turbine and draining water from moisture separators and number 6 high pressure feedwater heaters and supplied into steam generators. Because the extracting steam from the high pressure turbine is two phase fluid of high temperature, high pressure, and high speed and flows to inverse direction after impinging to impingement baffle. the shell wall of the number 5 high pressure feedwater heater may be affected by flow accelerated corrosion. On May 14, 1999, Point Beach Nuclear Plant (PBNP) with operating at full power experienced a steam leak from rupture of shell side of number 4B feedwater heater. Also, d domestic nuclear power plant experienced a severe wall thinning of shell side of number 5A and 5B feedwater heaters. This paper describes the fluid mixing analysis study using PHOENICS code in order to get at the root of the shell wall thinning of the feedwater heaters. The sections included in the fluid mixing analysis model are around the number 5h feedwater heater shell including the extracting pipeline. To identify the relation between the local velocities and wall thinning. the local velocities according to the analysis results were compared with the distribution of the shell wall thickness by ultrasonic test.

  • PDF