• 제목/요약/키워드: wall defect

검색결과 432건 처리시간 0.024초

열처리된 AgInS$_2$ 박막의 defect 연구 (Defect studies of annealed AgInS$_2$ epilayer)

  • 백승남;홍광준
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 하계학술대회 논문집
    • /
    • pp.257-265
    • /
    • 2002
  • A stoichiometric mixture of evaporating materials for AgInS$_2$ single crystal thin films was prepared from horizontal furnace. To obtain the single crystal thin films, AgInS$_2$ mixed crystal was deposited on thoroughly etched semi-insulating GaAs(100) substrate by the Hot Wall Epitaxy(HWE) system. The source and substrate temperatures were 680 $^{\circ}C$ and 410 $^{\circ}C$, respectively. The crystalline structure of the single crystal thin films was investigated by the photoluminescence and double crystal X-ray diffraction(DCXD). The carrier density and mobility of AgInS$_2$ single crystal thin films measured from Hall effect by van der Pauw method are 9.35${\times}$10$\^$16/ cm$\^$-3/ and 294 $\textrm{cm}^2$/V$.$s at 293 K, respectively. From the optical absorption measurement, the temperature dependence of the energy band gap on AgInS$_2$ single crystal thin films was found to be E$\_$g/(T) : 2.1365 eV - (9.89 ${\times}$ 10$\^$-3/ eV) T$^2$/(2930 + T). After the as-grown AgInS$_2$ single crystal thin films was annealed in Ag-, S-, and In-atmospheres, the origin of point defects of AgInS$_2$ single crystal thin films has been investigated by using the photoluminescence(PL) at 10 K. The native defects of V$\_$AG/, V$\_$S/, Ag$\_$int/, and S$\_$int/ obtained from PL measurements were classified as a donors or acceptors type. And we concluded that the heat-treatment in the S-atmosphere converted AgInS$_2$ single crystal thin films to an optical p-type. Also, we confirmed that In in AgInS$_2$/GaAs did not form the native defects because In in AgInS$_2$ single crystal thin films did exist in the form of stable bonds.

  • PDF

A novel technique for placing titanium mesh with porous polyethylene via the endoscopic transnasal approach into the orbit for medial orbital wall fractures

  • Bae, Seong Hwan;Jeong, Dae Kyun;Go, Ju Young;Park, Heeseung;Kim, Joo Hyoung;Lee, Jae Woo;Kang, Taewoo
    • Archives of Plastic Surgery
    • /
    • 제46권5호
    • /
    • pp.421-425
    • /
    • 2019
  • Background The endoscopic transnasal approach is widely used for reconstructing the medial orbital wall by filling it with a silicone sheet or Merocel, but this technique has the disadvantage of retaining the packing for a long time. To overcome this drawback, a method of positioning an absorbable plate in the orbit has been introduced, but there is a risk of defect recurrence after the plate is absorbed. Here, the authors report the results of a novel surgical technique of placing a nonabsorbable titanium mesh with porous polyethylene into the orbit through the endoscopic transnasal approach. Methods Fourteen patients underwent surgery using the endoscopic transnasal approach. Preoperative computed tomography (CT) was used to calculate the size of the bone defect due to the fracture, and the titanium mesh was designed to be shorter than the anteroposterior length of the defect and longer than its height. The titanium mesh was inserted into the orbit under an endoscopic view. The authors then confirmed that the titanium mesh supported the orbital contents by pressing the eyeball and finished the operation. Immediately after surgery, CT results were evaluated. Results Postoperative CT scans confirmed that the titanium mesh was well-inserted and in the correct position. All patients were discharged without any complications. Conclusions We obtained satisfactory results by inserting a titanium mesh with porous polyethylene into the orbit via the transnasal approach endoscopically.

심근관류 SPECT와 64채널 전산화 단층혈관 촬영 사진 융합으로 증명된 radius intermedius 협착에 의한 심근관류 저하 (Radius Intermedius Stenosis Induced Myocardial Perfusion Defect: Provened by the Fusion Images of Myocardial Perfusion SPECT and 64 Channel CTA)

  • 공은정;조인호;천경아;원규장;이형우;박종선
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제42권1호
    • /
    • pp.77-78
    • /
    • 2008
  • A 71-year-old woman was assigned to our department for Tc-99m myocardial perfusion SPECT(MPS) and coronary CT angiography. She admitted for substernal pain, via the ER, 2 days ago. The heart was scanned after intravenous injection of 925 MBq of $^{99m}Tc$-sestamibi adenosine-induced stress SPECT using dual head gamma camera (Hawkeye, GE healthcare. USA). The MPS shows decreased tracer uptake in the apical & mid area of anterior & lateral wall and mid & basal inferior wall. Coronary CT angiograph was obtained using Discovery VCT (GE healthcare). 3D angiography portrayed significant stenosis of ramus intermedius(RI) and posterolateral branch of right coronary artery(PLB) with fibrocalcified plaque. Two images were fused using Cardiac IQ fusion softwear package (Advantage workstation 4.4, GE healthcare) The fusion images explain the perfusion defect of anterior, lateral and inferior wall is due to stenosis of the RI and PLB. And 3 days later, coronary angiography was done and revealed the marked stenosis of RI and PLB. Then balloon angioplasty and stent was instituted in RI. Cardiac SPECT/CT fusion imaging provides additional information about hemodynamic relevance and facilitates lesion interpretation by allowing exact allocation of perfusion defects to its subtending coronary artery.

성견 1면 치조골 결손부에서 특수제조된 Calcium Sulfate Paste가 치주조직 치유에 미치는 영향 (Periodontal repair in dogs: effect of the modified calcium sulfate paste on the 1-wall intrabony defects)

  • 김종관
    • Journal of Periodontal and Implant Science
    • /
    • 제29권1호
    • /
    • pp.153-171
    • /
    • 1999
  • The purpose of this study was to evaluate the effect of modified calcium sulfate paste on periodontal regeneration. l-wall intrabony defect(mesio-distal width: 4mm, depth: 4mm) was surgically created on the distal side of P2 and mesial side of p4 in four dogs. The control group(GFS) was treated with conventional flap operation alone, and the experimental group(CS) was treated with conventional flap operation with modified calcium sulfate paste application. Both control and experimental groups were sacrificed after 8weeks of healing period, The results of histological and histometric observations were as follows. 1. The length of the junctional epithelium was 0.41${\pm}$0.01mm in the control groups, 0.47${\pm}$0.01mm in the experimental group. 2. The connective tissue attachment was 0.28${\pm}$0.02mm(6.15${\pm}$0.28%) in the control group, 0.18${\pm}$0.01mm(3.41${\pm}$0.14%) in the experimental group. The control group showed more connective tissue attachment. 3. The new cementum formation was 3.80${\pm}$0.06mm(84.80${\pm}$0.33%) in the control group, 4.49${\pm}$0.06mm(87.57${\pm}$0.15%) in the experimental group. Both groups showed a lot of new cementum formation. 4. The new bone formation was 1.43${\pm}$0.03mm(32.37%) in the control group, 2.04${\pm}$O.09mm(40.94%) in the experimental group. 5. The inflamatory cells were observed partially around resorbed calcium sulfate in the connective tissue of the experimental group. 6. Partially resorbed calcium sulfate were found within the connective tissue, around alveolar bone, and in the newly formed alveolar bone, On the basis of these results, newly formed calcium sulfate paste enhanced new bone formation and new cementum formation. The resorption rate of calcium sulfate seems to be controlled by the add-in compounds. Thus research about biocompatibility and adequate resorptionrate is required to develop a improved material.

  • PDF

흉부에서 발생한 악성 섬유성 조직구종 (Malignant Fibrous Histocytoma Originating from the Chest Wall)

  • 이철범;정태열;함시영;김혁;정원상;김영학;강정호;지행옥;박용욱
    • Journal of Chest Surgery
    • /
    • 제33권4호
    • /
    • pp.333-337
    • /
    • 2000
  • Malignant fibrous histiocytoma(MFH) is a deep-seated pleomorphic sarcoma, which occurs principally as a mass of the extremities, abdominal cavity, or retroperitoneum in adults. However, it only rarely occurs in the chest wall. An 85-year-old man had undeergone excision of a small mass on the right posterior chest wall under local anesthesia 14 months age. However, the lesion did not heal and the mass recurred. He was referred to our hospital after the mass had grown to a size of 10.5$\times$8$\times$4cm with a 3$\times$3cm skin defect. Intraoperative frozen biopsy revealed MFH. An en-bloc wide resection and thin-thickness skin graft from his thigh were performed. Although distant metastasis to the lund developed 14 months later and the patient died 2 months later, there was no local recurrence. Thin-thickness skin graft is a simple method for a wide range skin defect, especially in the old age. He recovered in good condition without any physical disabilities.

  • PDF

강자성체 배관 탐상용 RFECT System의 설계에 관한 연구 (A Study on the Design of RFECT System for Ferromagnetic Pipelines)

  • 이유기;김희민;박관수
    • 한국자기학회지
    • /
    • 제24권6호
    • /
    • pp.171-178
    • /
    • 2014
  • 전자기를 이용하여 배관의 비파괴검사를 적용하는 방법 중 하나인 Remote Field Eddy Current Testing (RFECT)는 큰 마찰력이 발생하고 잔류자화성분이 남는 Magnetic Flux Leakage (MFL) 방식과 외벽의 결함을 측정하는데 곤란한 일반 Eddy Current Testing (ECT) 방식의 단점들을 보완할 수 있는 기법으로 50여 년 전부터 다양한 기관에서 연구되어왔다. 그러나 배관 내에서 발생하는 와전류와 자기장에 대한 연구와 RFECT Exciter Coil의 설계에 대한 논의가 부족한 실정이다. 본 논문에서는 유한요소법을 이용한 전자기 해석을 통해 배관 내에서 발생하는 와전류와 자기장의 분포를 확인하고 변수 변화에 따른 영향을 분석하였다. 또한 Exciter Coil에 대한 최적 설계 알고리즘을 제시하고, 결함 형상과 기타 변수 변화가 결함신호에 미치는 영향을 확인하였다.

박육 스테인리스 주강에 대한 유동 및 응고해석의 실험적 고찰 (Experimental Study of Flow and Solidification Simulation for Thin Wall Stainless Steel Castings)

  • 최학규;박홍일;정해용;배차헌;최병강
    • 한국주조공학회지
    • /
    • 제20권5호
    • /
    • pp.344-353
    • /
    • 2000
  • In order to find out the casting conditions of the thin wall stainless steel exhaust manifold for automobile, the melt flow and solidification behavior simulated by the Z-CAST program were evaluated, and experimental casting result on the test casting and exhaust manifold of SSC13 alloy were investigated. From the results of this study, it was shown that the calculated results on fluid flow were in good agreement with practical thin wall test castings under the same casting conditions, as pouring metal is austenitic stainless steel(SSC13) and pouring temperature is 1575, 1630, and $1665^{\circ}C$ respectively. That calculated result with designed thin wall exhaust manifold was predicted filling up into the mold cavity, and practical casting was sound. The solidification simulation was predicted shrinkages at the bosses for original exhaust manifold, and designed it without bosses was predicted no defect. Therefore practical exhaust manifold casting was sound and in good agreement with calculated solidification results.

  • PDF

Medial Wall Orbital Reconstruction using Unsintered Hydroxyapatite Particles/Poly L-Lactide Composite Implants

  • Park, Hojin;Kim, Hyon-Surk;Lee, Byung-Il
    • 대한두개안면성형외과학회지
    • /
    • 제16권3호
    • /
    • pp.125-130
    • /
    • 2015
  • Background: Poly-L-lactide materials combined with hydroxyapatite (u-HA /PLLA) have been developed to overcome the drawbacks of absorbable materials, such as radiolucency and comparably less implant strength. This study was designed to evaluate the usefulness of u-HA/PLLA material in the repair of orbital medial wall defects. Methods: This study included 10 patients with pure medial wall blow-out fractures. The plain radiographs were taken preoperatively, immediately after, and 2 months after surgery. The computed tomography scans were performed preoperatively and 2 months after surgery. Patients were evaluated for ease of manipulation, implant immobility, rigidity and complications with radiologic studies. Results: None of the patients had postoperative complications, such as infection or enophthalmos. The u-HA/PLLA implants had adequate rigidity, durability, and stable position on follow-up radiographic studies. On average, implants were thawed 3.4 times and required 14 minutes of handling time. Conclusion: The u-HA/PLLA implants are safe and reliable for reconstruction of orbital medial wall in terms of rigidity, immobility, radiopacity, and cost-effectiveness. These thin yet rigid implants can be useful where wide periosteal dissection is difficult due to defect location or size. Since the u-HA/PLLA material is difficult to manipulate, these implants are not suitable for use in complex 3-dimensional defects.

흉골에 발생한 연골육종: 수술 치험 1례 (Chondrosarcoma of the Sternum - One Case Report -)

  • 정진용
    • Journal of Chest Surgery
    • /
    • 제24권8호
    • /
    • pp.802-806
    • /
    • 1991
  • Primary neoplasms of the ribs and sternum are rare. Most primary bony chest wall neoplasms are malignant, and chondrosarcoma is the most common malignancy in this location The etiology of chondrosarcoma is unknown. Definitive diagnosis of chondrosarcoma can only be made pathologically. The natural history of chest wall chondrosarcoma is one of slow growth and local recurrence. Most tumors of the sternum require wide resection and reconstruction procedures, with potentially serious postoperative problems. Advances in chest wall reconstruction primarily through refinement in muscle transposition and clarification of the functional anatomy and blood supply of trunk muscles, has resulted in a more aggressive resection of the these tumors . Recently we experienced a case with chondrosarcoma of the sternum. A 56 year-old man was admitted to our hospital due to painless, slowly enlarging mass at the left sternoclavicular junctional area. The chest radiograph strongly suggested an underlying cartilaginous neoplasm owing to the appearance of typical flocculent and curvilinear calcifications within the lesion. On CT of the chest, the tumor exhibited a scalloped or lobulated contour, hypodensity of the nonmineralized component in comparison to adjacent muscle, and characteristic stippled cartilaginous matrix mineralization, also typical for cartilaginous neoplasm. The patient underwent wide resection of the chest wall tumor include with a 2-3cm margin of normal tissue on all sides and the thoracic skeletal defect was reconstructed with polytetrafluoroethylene [Gore-Tex] soft-tissue patch. Soft tissue reconstructive procedure was done with the pectoralis major muscle transposition. The patient had an uneventful postoperative course and discharged without adjuvant treatment such as radiation and chemotherapy.

  • PDF

Hot Wall Epitaxy(HWE) 법에 의해 성장된 $CuGaSe_2$ 에피레이어의 광발광 특성 (Photoluminescience propeerties for $CuGaSe_2$ epilayers grown by hot wall epitaxy)

  • 김혜정;홍광준
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 추계학술대회 논문집 Vol.21
    • /
    • pp.100-101
    • /
    • 2008
  • To obtain the single crystal thin films, $CuGaSe_2$ mixed crystal was deposited on thoroughly etched semi-insulating GaAs(100) substrate by the hot wall epitaxy (HWE) system. The source and substrate temperatures were $610^{\circ}C$ and $450^{\circ}C$, respectively. After the as-grown $CuGaSe_2$ single crystal thin films was annealed in Cu-, Se-, and Ga-atmospheres, the origin of point defects of $CuGaSe_2$ single crystal thin films has been investigated by the photoluminescence(PL) at 10 K. The native defects of $V_{CU}$, $V_{Se}$, $Cu_{int}$, and $Se_{int}$ obtained by PL measurements were classified as a donors or acceptors type. And we concluded that the heat-treatment in the Cu-atmosphere converted $CuGaSe_2$ single crystal thin films to an optical n-type. Also, we confirmed that Ga in $CuGaSe_2$/GaAs did not form the native defects because Ga in $CuGaSe_2$ single crystal thin films existed in the form of stable bonds.

  • PDF