• 제목/요약/키워드: volume size distribution

검색결과 554건 처리시간 0.023초

정상.과도 분사 조건에서의 에어슈라우드 인젝터 분무의 입경.분사량 분포에 관한 연구 (A study on distribution of drop size and injection rate of air-shroud injector sprays under steady and transient injection condition)

  • 이충훈
    • 한국분무공학회지
    • /
    • 제9권4호
    • /
    • pp.17-23
    • /
    • 2004
  • Spray characteristics of a twin-hole air shrouded nonle designed for gasoline injectors was investigated by using laser diffraction particle analyzer (LDPA) and tomography reconstruction- A confined spray chamber which is optically accessible through a pair of glass windows was made to simulate the fuel injection condition in intake manifold of gasoline engine. The measurement was applied to the twin hole injector with and without an air shroud. It demonstrates that for the case with an air shroud, fine atomization is achieved and there exists a large number of fine droplets between the region of the main spray streams, which conforms with the spray visualization. The drop size distribution was investigated as a function of elapse time after fuel injection. The distribution was greatly affected by the measurement position from the injector exit. Also, the spatially resolved spray volume fraction and Sauter Mean Diameter (SMD) from line-of-sight data of the LDPA are tomographically reconstructed by Convolution Fourier transformation under the steady injection condition.

  • PDF

International Trade and Logistics of Kazakhstan and Its Trading Partners: Contribution to Economic Growth and Distribution of Trade Flows

  • Zhanarys RAIMBEKOV;Zhibek RAKHMETULINA;Tana ABYLAIKHANOVA;Bakyt SYZDYKBAYEVA;Aigerim RAKHMETULINA
    • 유통과학연구
    • /
    • 제21권9호
    • /
    • pp.67-79
    • /
    • 2023
  • Purpose: To investigate the intensity of bilateral international trade of the Silk Road Economic Belt (SREB) countries with Kazakhstan, its relationship with logistics (LPI), to assess their contribution to economic growth and distribution of commodity flows. Research design, data, and methodology: The method of analyzing the bilateral trade flow was applied by using the trade intensity index (TII) and a multidimensional regression model describing the relationship between LPI and its components, TII, the volume of exports and imports, GDP. Results: The nature and directions of the relationship between TII and the key components of logistics, the positive impact of LPI on the intensity of trade are established. It is revealed that the intensity of trade between the countries in the direction of the EAEU-Kazakhstan has a greater impact on the growth of LPI than in the opposite direction. At the same time, the higher the level of trade integration and the volume of GDP, the stronger their impact on the efficiency of logistics and distribution of commodity flows. Conclusions: Effective distribution of commodity flows will require the development of logistics components based on the direction of bilateral trade and the size of countries, the intensification of state reforms in the field of international trade and distribution logistics.

2001년 겨울철 서울 대기 에어로졸의 입경별 수 농도 특성 (Characteristics of Urban Aerosol Number Size Distribution in Seoul during the Winter Season of 2001)

  • 배귀남;김민철;임득용;문길주;백남준
    • 한국대기환경학회지
    • /
    • 제19권2호
    • /
    • pp.167-177
    • /
    • 2003
  • The number size distribution of urban aerosols ranging from 0.02 to 20 ${\mu}{\textrm}{m}$ in diameter was measured by using a scanning mobility particle sizer (SMPS) system and an aerodynamic particle sizer spectrometer (APS) at Seoul from November 30,2001 to January 14, 2002. The gaseous species such as CO, NO, NO$_2$, and $O_3$ were also continuously monitored. The daily average concentration of urban aerosols sorted into three groups (0.02~0.1 ${\mu}{\textrm}{m}$, 0.1~1 ${\mu}{\textrm}{m}$ and 1~10 ${\mu}{\textrm}{m}$) and the typical number, surface, and volume distributions of urban aerosols were discussed in this paper. The weekly variation of aerosol concentration was compared with those of gaseous concentrations. relative humidity, and visibility. The results showed that the particle number concentration seemed to increase in the morning and the number concentration of fine particles less than 1 fm in diameter seemed to increase when the concentrations of CO, NO, and NO$_2$ were high. The number concentration of fine particles was relatively high when the relative humidity was greater than 70% during the increasing period of relative humidity. The visibility was weakly correlated with the concentration of aerosols ranging 0.1 to 1 ${\mu}{\textrm}{m}$, and the number size distribution for high visibility episode was apparently different from that for low visibility episode.

국내 연속류 자전거도로의 차두시간 분포 모형 개발 (Development of a Time Headway Distribution Model for Uninterrupted Traffic Flow Bikeway in Korea)

  • 전우훈;이영인;양인철
    • 한국ITS학회 논문지
    • /
    • 제18권5호
    • /
    • pp.79-90
    • /
    • 2019
  • 본 연구에서는 국내의 연속류 자전거도로에 대한 차두시간 분포 모형을 개발하고자 하였다. 현장조사를 통해 수집된 데이터를 교통량으로 구분하여 분석하였으며, 교통량의 기준은 전체 교통량을 분포를 고려하여 1분당 8대 미만은 낮은 수준의 교통량으로 하고 8대 이상은 높은 수준의 교통량으로 구분하였다. 차두시간의 집계간격은 기존의 자동차교통류에서 일반적으로 적용해오던 0.5초를 적용하였다. 적용된 분포는 기본적인 정규분포와 함께 음지수분포, 전이된 음지수분포, 피어슨 III분포이며, 카이스퀘어 검정 분석결과 음지수분포와 전이된 음지수분포에서 방향과 교통량 구분 모두에서 이론치와 관측치간에 적합한 것으로 나타났다. 제시된 자전거 차두시간 분포모형의 적정성을 판단하기 위한 분석결과, 역시 동일하게 음지수분포와 전이된 음지수분포가 적합한 것으로 나타났다.

비 인두암 체적 조절 호형 방사선 치료의 선량 계산 격자 크기에 따른 선량 체적 지수와 방사선 생물학적 지수의 평가 (Evaluation of Dose Volume and Radiobiological Indices by the Dose Calculation Grid Size in Nasopharyngeal Cancer VMAT)

  • 강동진;정재용;신영주;민정환;심재구;박소현
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제43권4호
    • /
    • pp.265-272
    • /
    • 2020
  • The purpose of this study was to investigate the dose-volume indices and radiobiological indices according to the change in dose calculation grid size during the planning of nasopharyngeal cancer VMAT treatment. After performing the VMAT treatment plan using the 3.0 mm dose calculation grid size, dose calculation from 1.0 mm to 5.0 mm was performed repeatedly to obtain a dose volume histogram. The dose volume index and radiobiological index were evaluated using the obtained dose volume histogram. The smaller the dose calculation grid size, the smaller the mean dose for CTV and the larger the mean dose for PTV. For OAR of spinal cord, brain stem, lens and parotid gland, the mean dose did not show a significant difference according to the change in dose calculation grid size. The smaller the grid size, the higher the conformity of the dose distribution as the CI of the PTV increases. The CI and HI showed the best results at 3.0 mm. The smaller the dose calculation grid size, the higher the TCP of the PTV. The smaller the dose calculation grid size, the lower the NTCP of lens and parotid. As a result, when performing the nasopharynx cancer VMAT plan, it was found that the dose calculation grid size should be determined in consideration of dose volume index, radiobiological index, and dose calculation time. According to the results of various experiments, it was determined that it is desirable to apply a grid size of 2.0 - 3.0 mm.

都市大氣중 浮遊粒子狀物質, 鹽化物, 窒酸鹽 및 黃酸鹽의 濃度와 粒經分布 (Concentration and Size Distribution of Atmospheric Particulate Matters, Chloride, Nitrate, and Sulfate Salts in Urban Air)

  • 손동헌;허문영
    • 한국대기환경학회지
    • /
    • 제2권3호
    • /
    • pp.27-33
    • /
    • 1986
  • Atmospheric particulate matter (A. P. M.) was collected and size-fractionated by an Andersen high-volume air sampler over 15 month period from Jan. 1985 to Feb. 1986 in Seoul. The concentration of chloride, nitrate and sulfate were extracted in an ultrasonic bath and were analyzed by ion chromatography. The annual arithmetical mean of A. P. M. was 128.54 $\mug/m^3$. The concentration of anions were 2.88 $\mug/m^3$ for chloride, 3.86$\mug/m^3$ for nitrate, and 25.44$\mug/m^3$ for sulfate. The content of A. P. M. was lowest in the particle size range 1.1 $\sim 3.3\mum$ and increased as the particle size increased or decreased. And the anions exhibited a seasonal variation in the isize distribution. The contents of anions were higher in winter than summer. Ther ratio of fine particles to the total particles defined by F/T for chloride, nitrate and sulfate. The F\ulcornerT of these anion generally decrease with increasing air temperature. This tendency was prevalent in the chloride and nitrate.

  • PDF

에어로졸 광학깊이를 이용한 에어로졸 크기분포 추출 연구 (Study of Retrieving the Aerosol Size Distribution from Aerosol Optical Depths)

  • 김덕현
    • 한국광학회지
    • /
    • 제29권4호
    • /
    • pp.139-148
    • /
    • 2018
  • 본 연구에서는 250 nm와 1100 nm 사이에 있는 10개의 파장에서의 에어로졸 광학 깊이를 이용하여 에어로졸의 크기분포를 역산하는 연구를 수행하였다. 10개의 파장은 주요 대기 가스의 흡수선과 밴드를 피한 파장을 찾아서 선택하였다. 태양의 스펙트럼을 얻기 위해서 태양 추적시스템과 분광기를 구축하고 자체적으로 장치를 검정하였다. 본 장치를 이용해서 총 광학 깊이를 구하고 가스의 흡수나 공기의 산란을 제거하여 에어로졸의 광학 깊이를 구했다. 이정점 분포를 지닌 에어로졸 크기 분포를 역산하는 알고리즘을 제안하였고, 장치를 통해서 구한 에어로졸의 광학 깊이를 이용하여 다양한 임의의 대기 조건에서 그 크기분포를 역산하고 비교하였다. 이를 통하여 본 연구에서 사용한 방법론과 장치들이 미지의 입자 크기 분포를 추출하는데 매우 유용할 것으로 판단하였다.

$TiO_2$를 함유한 규산염 유리의 상분리를 이용한 다공질 유리의 제조 (Preparation of Porous Glasses by the Phase-separation of the Silicate Glass Containing $TiO_2$)

  • 김병훈;최석진;박태철
    • 한국세라믹학회지
    • /
    • 제28권1호
    • /
    • pp.29-36
    • /
    • 1991
  • Microporous glasses in the system TiO2-SiO2-Al2O3-B2O3-CaO-Na2O were prepared by the phase-separation technique. Morphology and distribution of pore and specific surface area of glasses heated and leached out at various conditions were investigated by SEM and Porosimeter. Crystallization of glasses heated above transition temperature was also inspected by X-ray diffraction method. When the heating temperature and time increased, the pore size and volume increased, but the specific surface area decreased above the critical temperature. The phase-separation, specific surface area and pore size showed more sensitive change on the variation of heating temperature than of heating time. The specific surface area and micropore volume of porous glasses prepared in this study were about 120-330$m^2$/g and 0.001-0.01cc/g, respectively. Mean pore size of porous glasses were about 20-90$\AA$. Anatase phases was deposited when the parent glass was heat-treated at 75$0^{\circ}C$ for 6hrs.

  • PDF

액주형 이류체노즐의 반경반향 분무특성에 관한 연구 (A Study on the Radial Spray Performance of a Plaint-Jet Twin-Fluid Nozzle)

  • 최진철;노병준;강신재
    • 대한기계학회논문집
    • /
    • 제18권3호
    • /
    • pp.662-669
    • /
    • 1994
  • In the combustion system, the optimum spray conditions reduce the pollutant emission of exhaust gas and enhance the fuel efficiency. The spray characteristics-the drop size, the drop velocity, the number density and the mass flux, become increasingly important in the design of combustor and in testifying numerical simulation of spray flow in the combustor. The purposes of this study are to clarify the spray characteristics of twin-fluid nozzle and to offer the data for combustor design and the numerical simulation of a spray flow. Spatial drop diameter was measured by immersion sampling method. The mean diameter, size distribution and uniformity of drop were analyzed with variations of air/liquid mass flow ratio. The results show that the SMD increases with the liquid supply flow rate and decreases with the air supply velocity. The radial distribution of SMD shows the larger drops can diffuse farther to the boundary of spray. And the drop size range is found to be wider close to the spray boundary where the maximum SMD locates.

디젤엔진에서 배출되는 미세 입자의 크기 분포 (Submicrometer Particle Size Distribution of Emissions from Diesel Engines)

  • 김민철;권순박;이규원;김종춘;류정훈;엄명도
    • 한국대기환경학회지
    • /
    • 제15권5호
    • /
    • pp.657-665
    • /
    • 1999
  • Particulate matter produced by diesel engines is of concern to cngine manufactures because of its environmental impact. The majority of diesel particles are in the range of smaller than 1 ${\mu}{\textrm}{m}$. Because of their tiny volume, ultrafine diesel particles contribute very little to the total mass concentration which is currently regulated for automobile emissions. Ultrafinc particles are known to have deleterious effects upon human health cspecially because they penetrate deeply human respiratory tract and have negative effects on the health. In this study, the engine exhaust gas was diluted in a dilution tunnel and the particle size distribution was measured using the scanning mobility particel sizer system. Measurements of the number and the mass concentrations of the diesel exhaust were made under different engine ooperating conditions. The dilution sampling system provided a common basis for collection of the exhaust by cooling and diluting the source emission prior to the measurement. The measurement results showed that the particle size distributions of the exhaust from the diesel vehicles equipment with either heavy-duty or lignt-duty diesel engines, were similar in the particle size range of 0.08~0.2${\mu}{\textrm}{m}$.

  • PDF