• Title/Summary/Keyword: volume correction

Search Result 409, Processing Time 0.026 seconds

Study on the Characteristics of Bread with Green Tea Powder (녹차가루를 이용한 식빵의 특성 연구)

  • 황윤경;현영희;이윤신
    • The Korean Journal of Food And Nutrition
    • /
    • v.14 no.4
    • /
    • pp.311-316
    • /
    • 2001
  • This study was designed to investigate the effective ratio of healthy bread wish green tea powder. The weight. volume, and colon difference of bread with various contents of green tea powder were measured. And the picture of bread and the panel test were taken. To avoid the decrease of volume, the experiment was taken with active gluten. The weight to bread was increased and the volume was decreased significantly according to increase of green tea powder ratio. But, the volume of the group with active gluten(3%+ and 4%+) was higher than that of the group with green tea powder 2%. That is which the correction of the volute was taken by active gluten in green tea powder bread. In the result of panel test and volume measurement. addition of 3% green tea powder was appropriate, and the addition of active gluten corrected the decrease of volume. Therefore. using the green tea powder, the diversity of bread by functionality, nutritional composition. taste, color. flavor of green tea powder can be developed. This result will support the background the development of green tea bread of good quality.

  • PDF

Internal pressure in a low-rise building with existing envelope openings and sudden breaching

  • Tecle, Amanuel S.;Bitsuamlak, Girma T.;Aly, Aly Mousaad
    • Wind and Structures
    • /
    • v.16 no.1
    • /
    • pp.25-46
    • /
    • 2013
  • This paper presents a boundary-layer wind tunnel (BLWT) study on the effect of variable dominant openings on steady and transient responses of wind-induced internal pressure in a low-rise building. The paper presents a parametric study focusing on differences and similarities between transient and steady-state responses, the effects of size and locations of dominant openings and vent openings, and the effects of wind angle of attack. In addition, the necessity of internal volume correction during sudden breaching, i.e., a transient response experiment was investigated. A comparison of the BLWT data with ASCE 7-2010, as well as with limited large-scale data obtained at a 'Wall of Wind' facility, is presented.

The Manifest Characteristics of Concrete that Uses Crushed Coarse Aggregate (발파석 굵은골재를 사용하는 콘크리트의 강도 발현 특성)

  • Lee, Hong-Kyu;Kim, Sang-Sup;Song, Yuan-Lou;Park, Young-Jun;Lee, Myeong-Ho;Han, Min-Cheol
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2015.11a
    • /
    • pp.132-133
    • /
    • 2015
  • In this research by examining the influence that low quality aggregate has on the strength of concrete through testing, the lowering of strength according to use of low quality coarse aggregate was reviewed. The results showed that when using low quality coarse aggregate, due to the quality of aggregate a high volume of units was required, and this caused the compression strength to be lowered. In conclusion it was confirmed that if the low quality aggregate was used as is without mix correction this would lead to faulty construction and if the aggregate was corrected to about 60 kg/m3 mix correction, this would lead to an economically infeasible concrete mix.

  • PDF

Effect of Posture Correction Band on Pulmonary Function in Individuals With Neck Pain and Forward Head Posture

  • Kim, Jae-hyeon;Jeong, Yeon-woo;Kim, Su-jin
    • Physical Therapy Korea
    • /
    • v.27 no.4
    • /
    • pp.278-285
    • /
    • 2020
  • Background: Individuals with forward head posture (FHP) have neck pain. To correct the FHP, a posture correction band is commonly used. However, we do not know the posture correction band influenced the pulmonary function in individuals with FHP. Objects: This study aimed to elucidate the effects of the posture correction band on the pulmonary function in young adults with neck pain and FHP and to monitor how the pulmonary function changed over time. Methods: Twenty subjects with chronic neck pain and forward head posture were recruited. Subjects performed pulmonary function test four times: before, immediately, and 2 hours after wearing the postural band, and immediately after undressing the postural band. Vital capacity (VC), forced vital capacity (FVC), peak expiratory flow (PEF), and forced expiratory volume at one second (FEV1) were measured. The modified Borg dyspnea scale was used to measure each subject's responses to the posture correction band. The mixed-effect linear regression was used to the effect of the posture correction band over time. Results: There were no significant differences in VC, FVC, PEF, FEV1 values over time (p > 0.05), although all values slightly decreased after applying posture correction band. However, the score of the modified Borg scale significantly changed after wearing the postural bands (p < 0.05), indicating the subject felt discomfort with posture correction band during breathing. Conclusion: Because the posture correction band did not change the pulmonary function over time, but it induces psychological discomforts during breathing in people with FHP. Therefore, this posture correction band can be used for FHP realignment after discussion with the subjects.

Assessment of 8-isoprostane (8-isoPGF2α) in Urine of Non-Small Cell Lung Cancer (NSCLC) Patients Undergoing Chemotherapy

  • Johns, Nutjaree Pratheepawanit;Johns, Jeffrey Roy
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.3
    • /
    • pp.775-780
    • /
    • 2012
  • 8-isoprostane (8-$isoPGF_{2{\alpha}}$) is a reliable marker and considered a gold standard for lipid peroxidation. There are very few reports of 8-isoprostane levels in cancer patients, and in patients undergoing chemotherapy. Oxidative stress is however expected and has been observed in patients with cancer. This study measured 8-isoprostane levels in urine by ELISA of 25 patients undergoing chemotherapy for advanced non-small cell lung cancer, at cycles 1, 2, and 3 of treatment. It considers the creatinine clearance of the patients, and correction of 8-isoprostane levels by creatinine clearance, and overnight urine volume methods. The average 8-isoprostane levels in urine increased more than 6 to 12 fold on chemotherapy treatment, from $532{\pm}587$ pg/mL at cycle $1,6181{\pm}4334$ at cycle 2, and $5511{\pm}2055$ at cycle 3. Similar results were obtained if 8-isoprostane levels were corrected for overnight urine volume, giving averages of $285{\pm}244{\mu}g$ at cycle $1,4122{\pm}3349$ at cycle 2, and $3266{\pm}1200$ at cycle 3. No significant difference was seen in average total overnight urine volume or number of urinations between chemotherapy cycles except for a large variation in urine volume between cycle 2 and 3. Creatinine levels were significantly different only between cycles 1 and 2 (p=0.016). In conclusion, cisplatin therapy has been shown to induce high levels of lipid peroxidation in lung cancer patients and can be assessed from the 8-isoprostane marker in overnight urine, with or without urine volume correction.

A Study on the Synthesis and Property of Azide Type Photosensitive Resin (Azide형 감광성수지의 합성과 특성에 관한 연구)

  • 조가람
    • Journal of the Korean Graphic Arts Communication Society
    • /
    • v.14 no.1
    • /
    • pp.115-131
    • /
    • 1996
  • The PVT(pressure-volume-temperature) relation of main-chain dimer liquid crystals having structures such as $\alpha$,$\omega$-bis[(4,4`-cyanobiphenyl) oxy] alkane(CBA-n with=9, 10) were studied. these dimer liquid crystals are known to form an enantiotropic nematic mesophase. In this work, we have determined the volume change as a function of temperature and pressure by using a GNOMIX PVT apparatus. In the V-Tcurves obtaind from isobaris mearements on various pressures, volume changes were observed at the nematic-isotropiz and nematic-crystal phase transitions. The volume changes at the transition exhibit slight odd-even effect with respect to the number of methylene unit n. The values of the (S)v obtained at the NI transition for CBA-9 and -10 were 6.9 and 12.6J/mol k. The valuesof (S)v for the CN transition were estimated on the basis of DSC(differential scanning calorimetry) data: 58.8(CBA-9) and 65.3J/mol k (CBA-10). For both transition, it was found that the correction about the volume change is significant, ranging from 40% to 60% of the total transition entropy observed under constant pressure.

  • PDF

Morphologic Alterations in Amygdala Subregions of Adult Patients with Bipolar Disorder

  • Lee, Hyun-Jae;Han, Kyu-Man;Kim, Aram;Kang, Wooyoung;Kang, Youbin;Kang, June;Won, Eunsoo;Tae, Woo-Suk;Ham, Byung-Joo
    • Korean Journal of Biological Psychiatry
    • /
    • v.26 no.1
    • /
    • pp.22-31
    • /
    • 2019
  • Objectives Previous studies have revealed inconsistent results on amygdala volume in adult bipolar disorder (BD) patients compared to healthy controls (HC). Since the amygdala encompasses multiple subregions, the subtle volume changes in each amygdala nucleus might have not been fully reflected in the measure of the total amygdala volume, causing discrepant results. Thus, we aimed to investigate volume changes in each amygdala subregion and their association with subtypes of BD, lithium use and clinical status of BD. Methods Fifty-five BD patients and 55 HC underwent T1-weighted structural magnetic resonance imaging. We analyzed volumes of the whole amygdala and each amygdala subregion, including the anterior amygdaloid area, cortico-amygdaloid transition area, basal, lateral, accessory basal, central, cortical, medial and paralaminar nuclei using the atlas in the FreeSurfer. The volume difference was analyzed using a one-way analysis of covariance with individual volumes as dependent variables, and age, sex, and total intracranial volume as covariates. Results The volumes of whole right amygdala and subregions including basal nucleus, accessory basal nucleus, anterior amygdaloid area, and cortico-amygdaloid transition area in the right amygdala of BD patients were significantly smaller for the HC group. No significant volume difference between bipolar I disorder and bipolar II disorder was found after the Bonferroni correction. The trend of larger volume in medial nucleus with lithium treatment was not significant after the Bonferroni correction. No significant correlation between illness duration and amygdala volume, and insignificant negative correlation were found between right central nucleus volume and depression severity. Conclusions Significant volume decrements of the whole amygdala, basal nucleus, accessory basal nucleus, anterior amygdaloid area, and cortico-amygdaloid transition area were found in the right hemisphere in adult BD patients, compared to HC group. We postulate that such volume changes are associated with altered functional activity and connectivity of amygdala nuclei in BD.

Stem Effect Correction Factor of Ionization Chamber in Exposure Measurements of High Energy Photons (고 에너지 광자선의 조사선량 측정 시 전리함의 스템효과 보정계수)

  • Park, Cheol-Woo;Lee, Jae-Seung;Kweon, Dae-Chel;Cha, Dong-Soo;Kim, Jin-Soo;Kim, Kyoung-Keun
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.12 no.1
    • /
    • pp.51-58
    • /
    • 2010
  • Ionization chambers often exhibit a stem effect, caused by interactions of radiation with air near the chamber end, or with dielectric in the chamber stem or cable. In this study measured stem effect correction factor for length of ionization chamber from medical linear accelerator recommend to with the use of stem correction method. For a model of the Farmer-type chamber, were used to calculate the beam quality correction factor. These interactions contribute to the apparent measured exposure. Additionally, it needs to consider ionization chamber use of small volume and stem effect of cable by a large field. Linear accelerator generated photons energy and increased dose repeatedly measured by using stem correction method. Stem effect was dependence of the energy and increases with photon energy conditions improved of beam quality. In conclusion, stem effect correction factor was measured within 0.4% calculated according to the exposures stem length and also supposed to determined below 1% of another stem correction method.

  • PDF

Design and Implementation of Hyperspectral Image Analysis Tool: HYVIEW

  • Huan, Nguyen van;Kim, Ha-Kil;Kim, Sun-Hwa;Lee, Kyu-Sung
    • Korean Journal of Remote Sensing
    • /
    • v.23 no.3
    • /
    • pp.171-179
    • /
    • 2007
  • Hyperspectral images have shown a great potential for the applications in resource management, agriculture, mineral exploration and environmental monitoring. However, due to the large volume of data, processing of hyperspectral images faces some difficulties. This paper introduces the development of an image processing tool (HYVIEW) that is particularly designed for handling hyperspectral image data. Current version of HYVIEW is dealing with efficient algorithms for displaying hyperspectral images, selecting bands to create color composites, and atmospheric correction. Three band-selection schemes for producing color composites are available based on three most popular indexes of OIF, SI and CI. HYVIEW can effectively demonstrate the differences in the results of the three schemes. For the atmospheric correction, HYVIEW utilizes a pre-calculated LUT by which the complex process of correcting atmospheric effects can be performed fast and efficiently.

Comparison of Recovery Coefficients for Correction of Reduced SUV by Partial Volume Effect and Organ Movements in PET/CT Images (PET/CT 영상의 부분체적효과와 장기의 움직임으로 인해 감소된 SUV의 보정을 위한 회복계수의 비교)

  • Kim, Youngjae;Park, Hoon-Hee;Lee, Joo-Young;So, Young;Lee, Jeong-Woo
    • Journal of radiological science and technology
    • /
    • v.45 no.3
    • /
    • pp.241-248
    • /
    • 2022
  • In this study, a recovery coefficient (RC) calculation was conducted that can correct the underestimation of the standardized uptake value (SUV) due to the partial volume effect (PVE) through phantom measurements and formulas. The experiment was conducted using a dynamic phantom capable of implement cranio-caudal movement at a respiratory rate of 15 times per minute along with the measured phantom experiment of the stopped state, and the RC of the moving state is calculated and compared. Ingenuity TF (Philips Healthcare, Netherland) was used as a positron emission tomography/computed tomography (PET/CT) device. PET-CT Phantom (Biodex Medical System, USA) was used as a phantom for measurement. A phantom image in a stationary state was acquired, and a moving phantom image was acquired using the AZ-733V Respiratory Phantom (Anzai Medical Co, Japan) capable of breathing movement in the cranio-caudal direction under the same acquisition parameters. For RC calculation, the sphere maximum radioactivity concentration and the background mean radioactivity concentration of the acquired images were measured, and the initially determined sphere and background radioactivity concentrations were calculated. The calculated RC was 0.08 to 0.72. The size of sphere smaller, it was confirmed that the RC reduced. And the RC in the moving state reduced than in the stationary state. As a result of this study, the change of the RC was confirmed according to the size of spheres and the phantom moving. Using the RC derived by implement movement of breathing with the respiratory phantom, it is possible to considering correction of underestimated SUV by the partial volume effect of PET images and the patient movements.