• Title/Summary/Keyword: voltammetry

Search Result 1,233, Processing Time 0.02 seconds

Determination of Ag(Ⅰ) Ion at a Modified Carbon Paste Electrode Containing N,N'-Diphenyl Oxamide

  • Won, Mi-Sook;Yeom, Jeong-Sik;Yoon, Jang-Hee;Jeong, Euh-Duck;Shim, Yoon-Bo
    • Bulletin of the Korean Chemical Society
    • /
    • v.24 no.7
    • /
    • pp.948-952
    • /
    • 2003
  • New approach for the determination of Ag(I) ion was performed by using a carbon paste electrode (CPE) containing N,N'-Diphenyl oxamide (DPO) with anodic stripping voltammetry. The CMEs have been prepared by making carbon paste mixtures containing an appropriate amount of DPO salt coated onto graphite particles to analyze trace metal ions via complexation followed by stripping voltammetry. Various experimental parameters affecting the response, such as pH, deposition time, temperature, and electrode composition, were carefully optimized. Using differential pulse anodic stripping voltammetry, the logarithmic linear response range for the Ag(I) ion was 1.0 × $10^{-7}$ - 5.0 × $10^{-9}$ M at the deposition time of 10 min, with the detection limit was 7.0 × $10^{-10}$ M. The detection limit adopted from anodic stripping differential pulse voltammetry was 7.0 × $10^{-10}$ M for silver and the relative standard deviation was ± 3.2% at a 5.0 × $10^{-8}$ M of Ag(I) ion (n = 7). The proposed electrode shows a very good selectivity for Ag(I) in a standard solution containing several metals at optimized conditions.

Determination of Ultra Trace Levels of Copper in Whole Blood by Adsorptive Stripping Voltammetry

  • Attar, Tarik;Harek, Yahia;Larabi, Lahcen
    • Journal of the Korean Chemical Society
    • /
    • v.57 no.5
    • /
    • pp.568-573
    • /
    • 2013
  • A selective and sensitive method for simultaneous determination of copper in blood by adsorptive differential pulse cathodic stripping voltammetry is presented. The procedure involves an adsorptive accumulation of Cu(II)-ETSC (4- ethyl-3-thiosemicarbazide) on a hanging mercury drop electrode, followed by a stripping voltammetry measurement of reduction current of adsorbed complex at about -715 mV. The optimum conditions for the analysis of copper (II) ion are : pH 10.3, concentration of 4-ethyl-3-thiosemicarbazide $3.25{\times}10^{-6}$ M and an accumulation potential of -100 mV. The peak current is proportional to the concentration of copper over the range 0.003-125 ng/mL with a detection limit of 0.001 ng/mL and an accumulation time of 60 s. Moreover, with the use of the proposed method, there is a considerable improvement in the detection limit, the linear dynamic range and the deposition time, compared with the methods of adsorptive stripping voltammetry for the determination of copper. The developed method was validated by analysis of whole blood certified reference materials.

The Corrosion behaviour of Pb-Ca alloy for Lead-acid battery by cyclic Voltammetry (Cyclic Voltammetry에 의한 연측전지용 Pb-Ca 합금의 부식특성 연구)

  • Kim, S.P.;Kim, G.T.
    • Proceedings of the KIEE Conference
    • /
    • 1995.07c
    • /
    • pp.1048-1050
    • /
    • 1995
  • Lead-acid battery is used widely as a power source at a automobile, industrial machines, folk lifts, U.P.S. etc. Lead-acid battery is cheaper than arty other secondary battery, but this battery has many disadvantages such as heavy, low energy density, environment problem etc. In this article, we introduce cyclic voltammetry methods to investigate corrosion behaviour of positive grids of Pb-Ca alleys.

  • PDF

Real-Time Voltammetric Assay of Lead Ion in Biological Cell Systems

  • Ly, Suw-Young
    • Toxicological Research
    • /
    • v.25 no.4
    • /
    • pp.231-235
    • /
    • 2009
  • Trace lead detection for cyclic voltammetry (CV) and square-wave (SW) stripping voltammetry was performed using mercury immobilized onto a carbon nanotube electrode (HNPE). Using the characteristics of mercury and the catalytic carbon nanotube structure, a modified technique, the $0.45{\mu}g/l$ detection limit of lead ion was attained. The developed method can be applied to pond water, fish tissue, plant tissue, and in vivo direct assay.

Investigation of Diazepam by Pulsed Rotation Voltammetry

  • Blaedel, W.J.;Hahn, Young-Hee
    • Archives of Pharmacal Research
    • /
    • v.2 no.2
    • /
    • pp.111-114
    • /
    • 1979
  • Diazepam was investigated in aqueous buffer media using pulsed rotation voltammetry. The dependence of half-wave potentials on pH indicated a two proton involvement in a two electron transfer reduction in the pH range 3-10. Dizaepam at micromolar concentration levels may be determined by measurement of the limiting difference current.

  • PDF

Assay of Trace Gold Ion in a Skin Cell Using a Stripping Voltammetry

  • Ly, Suw-Young;Lee, Jin-Hui;Yi, Jae-Hun
    • Journal of the Korean Applied Science and Technology
    • /
    • v.28 no.1
    • /
    • pp.15-21
    • /
    • 2011
  • Threelectrodes systems were used in stripping voltammetry (SW) and cyclic voltammetry (CV) instead of the expensive platinum and Ag/AgCl reference electrodes. Moreover, the electrolyte solution was used with deep seawater, which can reduce water pollution, is more eco-friendly, and has a lower cost. The analytical optimum parameters measured via CV and SW and with working ranges were obtained from 10 to 80 ug/L using fluorine immobilized on a graphite pencil electrode (FE). Under the optimum conditions, the analytical detection limit of 6.30 ug/LAu was obtained. The results of the study can be applied to diagnostic assay for natural minerals and human finger tissue.

Electrooxidation of DL-norvaline at Glassy Carbon Electrode: Approaching the Modified Electrode for Voltammetric Studies of Hydroquinone and Catechol

  • Kamel, Mahmoud M.
    • Journal of Electrochemical Science and Technology
    • /
    • v.5 no.1
    • /
    • pp.23-31
    • /
    • 2014
  • The DL-norvaline was electrochemically oxidized and deposited on the glassy carbon electrode surface using cyclic voltammetry (CV). The modified electrode was examined for electrochemical oxidation of hydroquinone (HQ) and catechol (CC). It exhibited good electrocatalytic ability towards their oxidation and simultaneous determination in a binary mixture using differential pulse voltammetry (DPV). The peak currents were linear to the concentration of HQ and CC, in the range from $5{\mu}M$ to $100{\mu}M$, and $4{\mu}M$ to $140{\mu}M$, respectively. The determination limits(S/N = 3) for HQ and CC were $1{\mu}M$ and $0.8{\mu}M$, respectively. The obtained modified electrode was applied to simultaneous detection of HQ and CC in water sample.

Diagnostic Ex-vivo Assay of Metal Gold in Rat Droppings Using Voltammetry

  • Ly, Suw-Young;Lee, Chang-Hyun
    • Journal of the Korean Applied Science and Technology
    • /
    • v.29 no.4
    • /
    • pp.626-630
    • /
    • 2012
  • Diagnosis with an ex-vivo gold sensor was done using a modified fluorine-doping sensor, and cyclic voltammetry (CV) redox potentials of 0.4 V anodic and -0.2 V cathodic were obtained. Both peak currents were optimized using square-wave (SW) stripping voltammetry, and an analytical working range of 10-80 ug/L SW was attained. The precision of the 10-mg/L Au was 0.765 (n=8) RSD under the optimum conditions, and the analytical detection limit approached 0.006 ug/L (S/N=3) with only a 60 sec accumulation time. The developed method was used to examine the mouse droppings for medicinal diagnosis.

α -Cyclodextrin Modified Screen Printed Graphite Electrodes for Detection of Phenols

  • Kim, Hwa-jeong;Jang, Seung-Cheol;Shim, Yoon-Bo
    • Bulletin of the Korean Chemical Society
    • /
    • v.23 no.3
    • /
    • pp.427-431
    • /
    • 2002
  • A screen printed graphite electrode has been developed for a simple and sensitive determination of phenolic compounds in an aqueous solution. The electrode developed uses a simple and effective screen printing technique with ${\alpha}-Cyclodextrin({\alpha}-CD)$ modified graphite ink. Phenols were captured on the surface of the ${\alpha}-CD$ modified electrode through complex formation. The phenol/ ${\alpha}-CD$ complex was deposited and quantified electrochemically using cyclic voltammetry (CV), differential pulse voltammetry (DPV) and square wave voltammetry (SWV). The optimization of the experimental parameters was performed in regard to electrode composition, pH, temperature, sample preconcentration time. Interferences from other organic compounds were investigated. The detection limit for phenols was 500 ${\pm}7$ nM for DPV, with the linear range of 0.5 ${\mu}M$ -25.0 ${\mu}M$ and 30 ${\pm}2$ nM for SWV, with the linear range of 30 nM - $50{\mu}M$, respectively.

Chemical Properties of Cu( II ) Compound Containing Endocrine Disrupter, Bis-Phenol A

  • Park, Chil-Nam
    • Environmental Sciences Bulletin of The Korean Environmental Sciences Society
    • /
    • v.10 no.S_3
    • /
    • pp.121-126
    • /
    • 2001
  • The techniques of pulse and cyclic voltammetry were applied to the determination of (E$_{1}$2)$_2$-(E$_{1}$2)$_1$ for two-step electrochemical charge transfers. In addition, a simple amplitude was derived far the dependence of the differential pulse response on (E$_{l}$ 2/)$_1$ and (E$_{1}$2/)$_2$. and the use of peak to peak separation in cyclic voltammetry and differential pulse methods was evaluated. A comparison of the comproportionation constants(Ke) from differential pulse and cyclic voltammetry methods exhibited a good agreement within 5%.

  • PDF