• 제목/요약/키워드: voltage standard

검색결과 977건 처리시간 0.027초

저압기기 정격절연전압 690V 개발시 고려사항에 대한 연구 (A Study on the Design of the rated insulation voltage of 690V for the low-voltage switchgear and controlgear)

  • 김명석;김종억;박상용
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 B
    • /
    • pp.961-963
    • /
    • 2000
  • Most of the application standard of the low-voltage devices have applied one the IEC standard another the UL standard. European union applied the IEC60947-1 standard has not exceed 1000V a.c. or 1500V d.c.. Therefore. it is necessary to the low-voltage device has expended for rated operational voltage with our products. The export of European market shall be made for the CE-Marking in accordance with IEC60947-1 ( Low-voltage switchgear and controlgear). We shall be considered for the requirement with the IEC standard. In this time to study for power supply system at EU ( European union. At that time for design and development in order to the construction and test method among the study for the rated insulation voltage at less then 690V.

  • PDF

IEC 저압간선의 허용전류 감소계수에 관한 연구 (A Study on Reduction Factor in Allowable Current of IEC Low-Voltage Wire)

  • 송영주;임명환;최대원;김도형;염성배
    • 조명전기설비학회논문지
    • /
    • 제24권12호
    • /
    • pp.100-108
    • /
    • 2010
  • A low voltage wire should be used considering that a load used in the end is a low voltage. In regard to these wires, there are needs for research about the wire thickness calculation in accordance with IEC standard because the standardization process for IEC (KS standard) was completed on June 30, 2005, and they stopped producing NEC-standard products by the order from Korean Agency for Technology and Standards under Ministry of Knowledge Economy (former Ministry of Commerce, Industry and Energy) since July 1, 2006. This study compared, in terms of the thickness calculation of low voltage wire, a reduction factor application by IEC standard about allowed current and an application for calculation of voltage drop. It also proposed the formula for IEC standard to decrease errors and resolve the difficulty of standardized calculation by analyzing the difference between simplified formula and standardized formula that are the most frequently used calculation method of voltage drop.

전파 뇌충격전압 측정용 표준 저항분압기의 개발 (Development of Standard Resistor Divider for Full Lightning Impulse Voltage)

  • 김익수;문인욱;김민규;김영배;김진기;이형호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 C
    • /
    • pp.1633-1635
    • /
    • 1994
  • This paper presents the development technology of standard resistor divider for full lightning impulse voltage. The ability of high voltage bulk power equipment to withstand lighting stroke is usually evaluated by means of full lightning impulse voltage. Lightning impulse voltage test has been essential to evaluate the insulation performance of electrical power apparatus. Recently International standard (IEC 60) on high voltage measurement techniques is being revised and requests a formal traceability of high voltage measurements. Therefore, general interest for this area has grown considerably during last years, and several international intercomparisions have been completed already worldwide, i.e. Europe, Japan, America etc.. In this viewpoint, we have also investigated the standard resistor divider with shield, which satisfies the IEC recommendation.

  • PDF

배전계통 PQM 시스템 구축 및 고조파전압 분석사례 (A Case of the Distribution Power System PQMS Construction & Harmonic Voltage Analysis)

  • 박용업;이건행
    • 조명전기설비학회논문지
    • /
    • 제24권9호
    • /
    • pp.108-117
    • /
    • 2010
  • The main contents of this paper are the PQM system construction case and distribution system harmonic voltage analysis. The PQM system has constructed by KEPCO in order to investigate power quality of distribution power system for new power quality standard of KEPCO. In result, we have confirmed that voltage harmonic measurement value of the high voltage contract customer 8 households is suitable the KEPCO harmonic standard tentative plan. And the voltage harmonic value of distribution line end side is not always more high than source side by harmonic current offset effect. In the future, acquired data by season, region, load from the PQMS will be used on the resonable harmonic standard enactment in KEPCO.

66kV급 전압변성기 비교측정 장치의 현장 평가설비 구축 (Construction of On-Site Calibration Facilities of 66 kV Voltage Transformer Comparator System)

  • 정재갑;이상화;권성원;김명수
    • 전기학회논문지
    • /
    • 제56권7호
    • /
    • pp.1268-1274
    • /
    • 2007
  • A recently developed methods for the on-site calibration of the voltage transformer (VT) comparator system have been reviewed in the paper. The method utilizes the several traveling standards consisting of the VT, the non-reactive standard resistors, the wide ratio error VT, and the decade resistors. The VT is used for the absolute evaluation of a standard VT belonging to the industry. The non-reactive standard resistor and wide ratio error VT are used for the linearity check of errors in the voltage comparator of the industry. The decade resistors are used for evaluation of a VT burden of the industry.

국제 표준에 따른 저압간선 전압강하 계산시 적용 방법 고찰 (Application Method Analysis at Voltage Drop Calculations on Low Voltage Feeder by IEC Standard)

  • 김기현;이주철;최영규;김한수;이영철
    • 조명전기설비학회논문지
    • /
    • 제26권6호
    • /
    • pp.53-58
    • /
    • 2012
  • A conductor has been produced according to IEC standard and low voltage electrical facility has been installed according to IEC 60364. But because of many related and varied standards, it is difficult to apply to design and inspect for electrical equipment. We researched the necessity of design guide which is detailed and systematization from survey. For detailed design guide, we suggest application method and review items at calculations for voltage drop calculations on low voltage feeder by IEC 60364, BS 7671 standard and Consumer's Electrical Installation Guide.

전파 뇌충격전압 측정용 쉴드저항분압기의 직각파 특성에 관한 연구 (A Study on the step response characteristics in shielded resistor divider for full lightning impulse voltage)

  • 김익수;이형호;조정수;박정후
    • 대한전기학회논문지
    • /
    • 제45권2호
    • /
    • pp.283-288
    • /
    • 1996
  • This paper presents the development technology of standard shielded resistor divider for full lightning impulse voltage. The ability of large-capacity power apparatus to withstand lighting stroke is usually evaluated by means of full lightning impulse voltage. Lightning impulse voltage test has been essential to evaluate the insulation performance of electrical power apparatus. Recently international standard (IEC 60) on high voltage measurement techniques is being revised and requests a formal traceability of high voltage measurements. Therefore, general interest for this area has grown considerably during last years, and several international intercomparisons have already completed worldwide, i.e. Europe, Japan, America etc., In this viewpoint, we have also investigated the step response of the standard shielded resistor divider, which satisfies the IEC recommendation.

  • PDF

200 kV 교류 고전압 국가표준 시스템 구축 (Establishment of 200 kV AC High Voltage National Standard System)

  • 정재갑;권성원;이상화;강전홍;송양섭;김명수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1414-1415
    • /
    • 2007
  • 200 kV AC high voltage national standard system has been established with a purpose for support of heavy electrical industry. The system consists of high AC voltage source and regulating unit, the standard voltage transformer, voltage transformer comparator, and voltage transformer burden, and voltage transformer under test.

  • PDF

240 kV 고전압 변성기 국가표준 시스템 구축 (Establishment of National Standard System for 240 kV High Voltage Transformer)

  • 정재갑;권성원;이상화;강전홍;김명수;한상길;김윤형;한상옥
    • 전기학회논문지P
    • /
    • 제57권2호
    • /
    • pp.164-169
    • /
    • 2008
  • National standard system for calibrating voltage transformer(VT) up to primary voltage of 240 kV have been established in 2005. The system consists of voltage source, regulating unit, VT testing unit, standard VT, VT under test and VT burden. To verify and validate the performance for 240 kV VT calibration system, the comparison with the National Measurement Institute of Australia(NMIA) has been performed using same VTs. The comparison results of the VTs mesured at the Korea Research Institute of Stansdards and Science(KRISS) are consistent with those measured at NMIA within 0.002 % for ratio error and 0.14 min for phase displacement in the primary voltage ranges of Vp = 3300 V - 22000 V with a secondary voltage of Vs = 110 V.

0.25 μm 표준 CMOS 로직 공정을 이용한 Single Polysilicon EEPROM 셀 및 고전압소자 (Single Polysilicon EEPROM Cell and High-voltage Devices using a 0.25 μ Standard CMOS)

  • 신윤수;나기열;김영식;김영석
    • 한국전기전자재료학회논문지
    • /
    • 제19권11호
    • /
    • pp.994-999
    • /
    • 2006
  • For low-cost embedded EEPROM, in this paper, single polysilicon EEPROM and n-channel high-voltage LDMOST device are developed in a $0.25{\mu}m$ standard CMOS logic process. Using these devices developed, the EEPROM chip is fabricated. The fabricated EEPROM chip is composed of 1 Kbit single polysilicon EEPROM away and high voltage driver circuits. The program and erase characteristics of the fabricated EEPROM chip are evaluated using 'STA-EL421C'. The fabricated n-channel high-voltage LDMOST device operation voltage is over 10 V and threshold voltage window between program and erase states of the memory cell is about 2.0 V.