• 제목/요약/키워드: voltage monitoring

검색결과 585건 처리시간 0.044초

전압 모니터링에 기반한 순간전압강하 확률적 추계 방법 (Stochastic Estimation of Voltage Sags Based on Voltage Monitoring)

  • 손정대;박창현
    • 전기학회논문지
    • /
    • 제67권10호
    • /
    • pp.1271-1277
    • /
    • 2018
  • This paper deals with a voltage sag assessment based on a voltage monitoring program. The voltage sag performance at a specific site can be evaluated by analyzing voltage monitoring data recorded for a long time period. Although an assessment based on voltage monitoring is an effective way to understand voltage sag performance at a measurement site, the statistical confidence of voltage sag frequency estimation heavily depends on the length of monitoring period and the number of recorded events. Short monitoring period and insufficient recorded data can not provide a reliable assessment result. This paper proposes a compensation assessment method by combining a computer simulation approach for in case that monitoring period and data are not enough for a valid assessment.

실시간 감시 정보를 이용한 전압안정도 제어 방안에 대한 연구 (A Study on the Voltage Stability Control Scheme using Real-time Monitoring Data)

  • 이윤환
    • 전기학회논문지P
    • /
    • 제66권4호
    • /
    • pp.206-212
    • /
    • 2017
  • In this paper, using the power system information obtained from real-time monitoring device, to analyze the voltage stability margin index and described the voltage stability control scheme for voltage stability enhancement. Based on the utilization of the voltage stability monitoring index based on local information provided by the PMU(Phasor Measurement Unit), the purpose of the plan is to control the system stably in real time. In order to apply the load control scheme, the voltage stability margin is calculated using the data acquired through the PMU installed in each load bus. If the voltage drops below a certain level, load control is performed for each. The effectiveness of the voltage stability control measures is applied to the actual KEPCO system to analyze the effectiveness.

전압안전성 온라인 감시시스템의 개발방안 (The Development Plan of Voltage Security On-Line Monitoring System)

  • 전동훈;권석기;안광원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 C
    • /
    • pp.1173-1175
    • /
    • 1998
  • This paper presented the development plan of voltage security on-line monitoring system (VSECOMs). VSECOMs consists of voltage security monitoring system and data management system. VSECOMs has the function of bus voltage watch. voltage stability analysis, and voltage security assessment. EMS data on-line acquisition, PSS/E file conversion, and overall data management. VSECOMs is designed with client/server structure. We will seek stable operation of KEPCO's power system by installation of VSECOMs in EMS of KEPCO.

  • PDF

연료전지 스택의 셀 전압 감시를 위한 장치 개발 (Development of Cell Voltage Monitoring Module for PEMFC)

  • 정재욱;김태후;박현석;전윤석;구본웅
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2006년도 추계학술대회
    • /
    • pp.376-379
    • /
    • 2006
  • In this paper, stack voltage monitoring module is developed which monitor cell voltage of the fuel cell stack and transfer it to the main controller for monitoring fault and stopping drive when the trouble is happened in the fuel cell stack. Especially, the circuit, for monitoring each cell voltage of several hundreds cells in stack, is designed and analyzed. The connector is also developed for making wire harness simple and low cost because wire harness is complicated when the cells are connect each monitoring circuit.

  • PDF

고압 회전기 고정자 권선의 절연진단을 위한 중앙 집중 감시 시스템 개발 (Development of Central Monitoring System for Insulation Diagnosis of High-Voltage Generator/Motor Stator Windings)

  • 신병철;윤대회;황돈하;김용주;주영호;김정우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.1906-1908
    • /
    • 2000
  • The central monitoring system with on-line diagnosis of high-voltage generator/motor stator insulation is developed. The system is capable of remote diagnosis and monitoring partial discharges of high-voltage generator/motor stator insulation. GOMS(Generator On-line Monitoring System) with maximum of 9 input channels can measure and analyze the status of high-voltage motor stator insulation by on-line. The measured and analysis data are brought to the central monitoring system via modem to build database. The central monitoring system can diagnose and monitor the insulation status of several high-voltage generator/motor at any time. The insulation status of those machines can be enhanced by the database on partial discharges.

  • PDF

순간전압강하 모니터링 데이터 분석 방법 (Development of a Method to Analyze Voltage Sag Monitoring Data)

  • 박창현
    • 조명전기설비학회논문지
    • /
    • 제27권4호
    • /
    • pp.16-22
    • /
    • 2013
  • This paper presents a method to analyze the voltage sag data obtained from monitoring systems. In order to establish effective countermeasures against voltage sag problems, an assessment of the system performance with respect to voltage sags is needed. Generally, the average annual sag frequency can be estimated by using the recorded voltage sag events for several years. However, the simple average value can not give the information about the errors of estimation. Such an average estimation is not useful for establishing effective solutions for voltage sag problems. Therefore, this paper proposes an effective method based on the Interval Estimation method. The estimation of voltage sag frequency is performed by using the average frequency and Poisson probability model. The proposed method can give the expected annual sag frequency and upper one-sided bound frequency.

한정된 위치의 PMU 정보를 이용한 수도권 전압안정도 감시 알고리즘 (A Voltage Stability Monitoring Algorithm using a Few PMUs in Metropolitan Area)

  • 한상욱;이병준
    • 전기학회논문지
    • /
    • 제58권12호
    • /
    • pp.2328-2334
    • /
    • 2009
  • Through the development of phasor measurement units (PMU), various aspects of power system dynamic behavior could be monitored and diagnosed. Monitoring dynamic voltage stability becomes one of achievements we can obtain from PMUs. It is very important to select the method appropriate to the KEPCO system since there are many voltage stability indices. In the paper, we propose an advanced WAVI (Wide Area Voltage Stability) for monitoring dynamic voltage stability. It reflects the PMU installation plan of KEPCO, thus it is suitable for KEPCO system specially. The salient features of the proposed index are; i) it uses only PMU measurements without coupling with EMS data. ii) it is computationally unburden so that it can be applied to real-time situation. The proposed index is applied to the KEPCO test system and the result shows that it successfully predicts voltage instability through the comparative studies.

분전반 통합 감시 시스템 개발 (Development of the Integrated Monitoring System for Panel boards)

  • 김일권;조현경;이동준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.347_348
    • /
    • 2009
  • In this paper, we described the integrated monitoring system for low-voltage panel boards. This system consists of three parts, a panel board controller, an integrated monitoring unit and a remote PC. The panel board controller which was made of CT/PT unit, control unit and power supply is able to transmit variable parameter for monitoring and diagnosis of low voltage branch circuits. Also, the integrated monitoring unit was collected monitoring data from panel boards and displayed on the touch panel.

  • PDF

A New Method for Monitoring Local Voltage Stability using the Saddle Node Bifurcation Set in Two Dimensional Power Parameter Space

  • Nguyen, Van Thang;Nguyen, Minh Y.;Yoon, Yong Tae
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권2호
    • /
    • pp.206-214
    • /
    • 2013
  • This paper proposes a new method for monitoring local voltage stability using the saddle node bifurcation set or loadability boundary in two dimensional power parameter space. The method includes three main steps. First step is to determine the critical buses and the second step is building the static voltage stability boundary or the saddle node bifurcation set. Final step is monitoring the voltage stability through the distance from current operating point to the boundary. Critical buses are defined through the right eigenvector by direct method. The boundary of the static voltage stability region is a quadratic curve that can be obtained by the proposed method that is combining a variation of standard direct method and Thevenin equivalent model of electric power system. And finally the distance is computed through the Euclid norm of normal vector of the boundary at the closest saddle node bifurcation point. The advantage of the proposed method is that it gets the advantages of both methods, the accuracy of the direct method and simple of Thevenin Equivalent model. Thus, the proposed method holds some promises in terms of performing the real-time voltage stability monitoring of power system. Test results of New England 39 bus system are presented to show the effectiveness of the proposed method.

Pilot Bus의 정보를 이용한 효율적인 지역별 전압제어 (Effective Localized-Voltage Control Scheme using the Information from Pilot Bus)

  • 송성환;윤용태;문승일;이호철
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제55권12호
    • /
    • pp.505-513
    • /
    • 2006
  • One of the major reasons for recent blackout, like August 14, 2003 blackout in the US and Canada has been insufficient voltage/reactive power support. For the stable reactive power management, a new approach for the voltage monitoring and control structure is required in the market environment. This paper proposes the effective localized-voltage control scheme using the information from pilot buses at each zone. In this paper, the steady state voltage monitoring and control (SSVMC) is adopted and illustrated for the voltage control scheme during steady state because it is thought as the systemic algorithm to explain voltage profile phenomenon before and after contingencies. And the concept of electrical distance is applied to simultaneously achieve both clustering the voltage control zone, and selecting the pilot bus as the representative node at each control zone. Applying SSVMC based on the structure with clustering and pilot bus enables system operators to monitor and understand the system condition much more easily, to monitor and control the voltage in real-time more manageably, and to respond quickly to a disturbance. The proposed voltage control scheme has been tested on the IEEE 14-bus system with the numerical analysis to examine the system reliability and structure efficiency.